Estimation of cutting forces in band sawing (톱절삭에서의 절삭력 예측)

  • Jung, Hoon;Baek, Dae-Kyun;Ko, Tae-Jo;Kim, Hee-Sool
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.31-35
    • /
    • 1996
  • The cross section of the circular rod type workpiece to be cut in the band saw machine is variable at every moment in the sawing process. When the cutting feed rate is fixed to the constant speed, the cutting edges of the band saw teeth are also variabl eat any moment, so this causes the wear of the land saw teeth and the deterioration of the quality in the surface roughness. In this study, to work out this kind of problem basically, the mean cutting force of a tooth in the band saw was estimated by using the workpiece which was smaller than the interval of each tooth, i.e. band saw pitch, in the thickness. Then the static cutting forces were predicted by appling the mean cutting forces referred above to the mechanistic cutting force model which were analyzed through the geometric profile of a band saw tooth.

  • PDF

Purification of Band 3 from the Human Erythrocyte Membrane and its Incorporation into Liposome (사람 적혈구막 Band 3의 정제 및 Liposome으로의 도입)

  • Kim, Jae-Ryong;Kim, Jung-Hye;Lee, Ki-Yung
    • Journal of Yeungnam Medical Science
    • /
    • v.3 no.1
    • /
    • pp.41-48
    • /
    • 1986
  • Band 3, the predominent 95,000 dalton anion transport protein, is the major intrinsic glycoprotein of the human erythrocyte membrane. This anion carrier exists as a dimer and binds the cytoskeletons such as spectrin, ankyrin and actin. And the liposomes are vesicular structures which form spontaneouly upon hydration of phospholipids. These artificial lipid vesicles have been investigated as model of the biological membranes and as a mean of improving the delivery of nucleic acids, drugs, proteins and biological substances to specific target tissues and cells. In this study, we were purified Band 3 from the human erythrocyte membrane(ghost) was prepared by hemolysis of intact human erythrocyte with weak alkali-hypotonic solution. Band 6 was removed from ghost by extracting with solution of an ionic strength of 0.15. Band 3 and Band 4 were solubilized selectively by extracting Band 6-depleted ghosts with Triton X-100 under nondenaturing conditions. Band 3 was then purified from Triton X-100 extract treated with p-chloromercuribenzoate by sucrose density gradient ultracentrifugation. This purified Band 3 was incorporated into liposomes prepared by reverse-phase evaporation. Phosphatidyl L-serine and cholesterol(1 : 1 molar ratio) were dissolved in chloroform and then chloroform was removed by rotatory evaporation under reduced pressure. Band 3 solution without Triton X-100 was introduced into a mixture of lipids and diethylether. Diethylether was subsequently removed by evaporation. This purified Band 3 and its incorporation into liposomes were confirmed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis.

  • PDF

A Study on Development of Base Station System for 13.56MHz & 2.45GHz Dual-band RFID (13.56MHz & 2.45GHz Dual-band RFID Base Station System 개발에 관한 연구)

  • Lee, Tae-Yun;Kim, Woong-Sub;Choi, Moon-Seung;Han, Woon-Soo;Jho, Yong-Chul;Kwon, Dae-Woo;Lee, Chang-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.4
    • /
    • pp.161-168
    • /
    • 2009
  • Ubiquitous application is in need of high-level technology to meet various requests for ubiquitous service. In order to adopt ubiquitous technology in not only pilot projects but also regional services, many projects like u-City are implemented in and outside the country. RFID has been known as one of the important technology to provide with core benefits of Ubiquitous services. Because each band of RFID technology has merits and demerits concurrently, single-band RFID system has limitations for various RFID services. Thus, we developed dual-band RFID system enable to provide with 13.56MHz and 2.45GHz RFID service at the same time to compensate the shortage of single-band RFID system. Also we have considered the way that the firmware would control signals without collision, studied battery life and range for tag, and made hardware for dual-band RFID service.

Effects of the Nei-Guan Acupressure by Wrist Band on Postoperative Nausea and Vomiting after Middle Ear Surgery (손목밴드를 이용한 내관지압이 중이수술 후 오심과 구토에 미치는 효과)

  • Lee, Myung-Yun;Min, Hye-Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.38 no.4
    • /
    • pp.503-512
    • /
    • 2008
  • Purpose: This study was to identify the effects of Nei-Guan accupressure using a wrist band on postoperative nausea and vomiting after middle ear surgery. Methods: The study design was a nonequivalent control group non-synchronized posttest design. Forty patients were assigned into two groups of 20 patients, the wrist band group and the control group. In the wristband group, acupressure was applied with a wrist band on the P6 point at both wrists from 30 min before to 24 hr after anesthesia. Results: The 1st hypothesis 'Applied wrist band groups will have a greater reduction in the nausea & vomiting grades by INVR than the control group' was accepted (t=2.303, p=.028). The 2nd hypothesis 'The Applied wrist band groups will have a greater reduction in the occurrence of nausea & vomiting than the control group' was partly accepted. The 3rd hypothesis 'The applied wrist band group will have a greater reduction in injection of antiemetics for 24 hr. post anesthesia than the control group' was rejected. Conclusion: Acupressure on the P6 point using a wrist band is effective to alleviate nausea for middle ear surgery patients.

Fin-Line Balanced Mixer Design for Ku-band Tracking Radar Receiver (Fin-Line 구조의 Ku대역 추적레이더 수신단용 평형 믹서 설계)

  • Na, Jae-Hyun;Roh, Don-Suk;Kim, Dong-Gil
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.4
    • /
    • pp.685-694
    • /
    • 2018
  • In this paper, we designed and fabricated the frequency mixer, which is the core parts of high frequency head in Ku-band tracking radar. To overcome the problem of single-ended and single-balanced resistive structure, we designed the fine-line structure with balanced mixer, to generate IF signal without distortion in L-band, after receiving the RF signal of the Ku-band. The prototype mixer showed a Noise Figure Max of 6.823dB, Gain of 4.1598~4.676dB and Band Pass of 61MHz in 5 Ku-band samples frequency.

GISPD Analysis Using UHF Dual-Band Method (UHF이중대역법을 이용한 GISPD분석)

  • Kim, Kwang-Hwa;Yi, Sang-Hwa;Choi, Jae-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1860-1862
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the characteristics of GIS PD signals measured with ultra wide band (UWB) GIS PD detecting system in which PD signals are detected into the dual UHF band. The UWB PD detection system consists of the UWB UHF coupler, the UWB low noise amplifier (LNA) and the oscilloscope. The dual bands for PD signals are 0.5-2GHz(full band) and 1-2GHz(high band). As results, it was found that the partial discharges of each defect have their own characteristic pattern and the ratio of High band to Full band increases with gas pressure.

  • PDF

Linear Prediction of Multispectral Images Per Pel Using Classification (영역분류를 이용한 다분광 영상 데이터의 화소 단위 선형 예측 기법)

  • 조윤상;구한승;나성웅
    • Proceedings of the IEEK Conference
    • /
    • 2000.11d
    • /
    • pp.163-166
    • /
    • 2000
  • In this paper, we will present a lossy data compression method for coding multispectral images. The proposed method uses both spatial and spectra] correlation inherent in multispectral images. First, band 2 and band 6 are vector quantized. Secondly, band 4 is estimated with the quantized band 2 using the predictive coding. Errors of band 4 are encoded at a second stage based on the magnitude of the errors. Thirdly, remaining bands are calculated with the quantized band 2 and band 4. Errors of residual bands are wavelet transformed and then we apply the SPIHT coding on the transformed coefficients. We classify classes without extra information transmitting and then use linear predictor. And errors can be encoded by SPIHT coding at any target rate we are want. It is shown that this method has better performance than FPVQ. Average PSNR rises 0.645 dB at the same bit rate.

  • PDF

A study on architecture of channel estimation for multi-band OFDM UWB system (멀티밴드 OFDM UWB 시스템을 위한 채널추정 구조에 관한 연구)

  • Lee Yong-Bae;Jeong Jin-Doo;Chong Jong-Wha
    • Proceedings of the IEEK Conference
    • /
    • 2004.06a
    • /
    • pp.293-296
    • /
    • 2004
  • This paper proposes an architecture of channel estimation for multi-band OFDM UWB systems presented to IEEE 802.15.3a by Multi-band OFDM alliance(MBOA). The multi-band OFDM (MB-OFDM) systems should have channel estimation for compensation of signal distortion by multi-band channel. The moving-averaging estimation algorithm and multi-band equalization architecture for MB-OFDM UWB systems proposed in this paper was verified by the simulation. Simulation results show that MB-OFDM system with the proposed architecture have the performance improved by about 3.4 dB compared to system with no channel estimation in 0.1$\pi$ phase-rotated channel.

  • PDF

A study on the Frequency Synthesizer for Dual-Band Repeater (이중대역 중계기를 위한 주파수합성기의 설계에 관한 연구)

  • Kim, Jin-Sub;Byeon, Sang-Gi;Kang, Yong-Cheol
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.277-280
    • /
    • 2005
  • In this paper, we propose a frequency synthesizer for dualband repeater. The dual-band RF technology for applications to the wireless repeater for CDMA and WCDMA mobile communications has been developed in this paper. The dualband PLL module consisted of dual-band VCO and one PLL IC has been developed. The main technological efforts for the dual-band PLL module is to suppress the intermodulation distortion by applying the miniature ceramic filter using the slow wave characteristics. The dual-band miniature RF module including dual-band PLL module and one MCU controller is very attractive for applications to the miniature dual-band RF mobile repeaters.

  • PDF

Adaptive Hysteresis Band Current Control Independent of the Back EMFs (역기전력에 무관한 가변 히스테리시스 밴드 전류 제어)

  • Kim, Kyeong-Hwa;Cho, Kwan-Yuhl;Chung, Se-Kyo;Oh, Dong-Seong;Youn, Myung-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1172-1175
    • /
    • 1992
  • The conventional adaptive hysteresis band current control technique has disadvantages such that on-line calculation of the hysteresis band is very complex, therefore, the adaptive hysteresis band must be stored in the look-up table. In this paper, a new simplified adaptive hysteresis band current control technique with phase decoupling is presented. The adaptive band is independent of the back EMFs. Using this adaptive band and the phase decoupled current error, the modulation frequency is fixed at nearly constant and the PWM inverter has optimal switching pattern.

  • PDF