• Title/Summary/Keyword: In-Line mixer

Search Result 63, Processing Time 0.024 seconds

Numerical Analysis on Mixing Efficiency in a Micro-channel with Varied Geometry (미소 채널의 형상변화에 의한 혼합효율에 관한 수치 해석적 연구)

  • Yoon, Joon-Yong;Han, Gyu-suk;Byun, Sung-Joon
    • Applied Chemistry for Engineering
    • /
    • v.16 no.2
    • /
    • pp.275-281
    • /
    • 2005
  • In this work, Scalar Passive code in Lattice Boltzmann Method was employed to simulate mixing performance of Passive mixer in a micro-channel. It physically analyzed stream line and Pressure drop for passive mixer in a micro-channel. The flow characteristics in a micro-channel was a function of Peclet number. The results indicated that the size of static element was more effect on the mixing than the number of static element and the distance of static elements.

A D-Band Balanced Subharmonically-Pumped Resistive Mixer Based on 100-nm mHEMT Technology

  • Campos-Roca, Y.;Tessmann, A.;Massler, H.;Leuther, A.
    • ETRI Journal
    • /
    • v.33 no.5
    • /
    • pp.818-821
    • /
    • 2011
  • A D-band subharmonically-pumped resistive mixer has been designed, processed, and experimentally tested. The circuit is based on a $180^{\circ}$ power divider structure consisting of a Lange coupler followed by a ${\lambda}$/4 transmission line (at local oscillator (LO) frequency). This monolithic microwave integrated circuit (MMIC) has been realized in coplanar waveguide technology by using an InAlAs/InGaAs-based metamorphic high electron mobility transistor process with 100-nm gate length. The MMIC achieves a measured conversion loss between 12.5 dB and 16 dB in the radio frequency bandwidth from 120 GHz to 150 GHz with 4-dBm LO drive and an intermediate frequency of 100 MHz. The input 1-dB compression point and IIP3 were simulated to be 2 dBm and 13 dBm, respectively.

Design of Broad Band RF Components for Partial Discharge Monitoring System (부분방전 모니터링 시스템을 위한 광대역 RF 소자설계 연구)

  • Lee, Je-Kwang;Ko, Jae-Hyeong;Kim, Koon-Tae;Kim, Hyeong-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2286-2292
    • /
    • 2011
  • In this paper we present the design of Low Noise Amplifier(LNA), mixer and filter for RF front-end part of partial discharge monitoring system. The monitoring system of partial discharge in high voltage power machinery is used to prevent many kinds of industrial accidents, and is usually composed of three parts - sensor, RF front-end and digital microcontroller unit. In our study, LNA, mixer and filter are key components of the RF front-end. The LNA consists of common gate and common source-cascaded structure and uses the resistive feedback for broad band matching. A coupled line structure is utilized to implement the filter, of which size is reduced by the meander structure. The mixer is designed using dual gate structure for high isolation between RF and local oscillator signal.

Numerical Study on effective Mixing Chemical Liquid using Hydraulic Energy in a Water Treatment Plant (정수장내 수류에너지를 이용한 액체약품의 효율적인 혼화를 위한 수리해석)

  • Song K. S.;Oh S. Y.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.132-137
    • /
    • 2001
  • We used In-line orifice mixer for efficient chemicals mixing in water treatment. The method of using In-line orifice mixer has been already proved the improvement of water treatment efficiency. Code of computational fluid dynamics for numerical analysis was performed using FLUENT, a commercial code. As variable for exactly standardizing, a proper ratio between an outer diameter of deflector and a diameter of pipe, the distance between deflector and orifice, a determination of orifice diameter fur an optimal mixing, a distance between injection nozzle's position and cone, Numerical study has been performed for optimal standard and analyzed flow field on a basis of turbulent intensity in an orifice downstream.

  • PDF

Balanced Mixer Based on Composite Right/Left-Handed Transmission Line Leaky-Wave Antenna (CRLH 전송 선로 리키 웨이브 안테나를 이용한 평형 믹서)

  • Kim, Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.9
    • /
    • pp.985-991
    • /
    • 2008
  • This paper presents a novel balanced mixer receiver front-end design based on a metamaterial structure applicable to differential-/common-mode excitation. This metamaterial structure functions as a leaky-wave antenna and provides in-trinsic common-mode suppression. Low LO leakage and high RF to LO isolation are achieved without additional filters for LO and RF paths. The metamaterial is based on a unit-cell which under a differential-mode excitation behaves like a composite right/left-handed(CRLH) metamaterial. In contrast, the metamaterial unit-cell is below cut-off under a common-mode excitation. Experimental results are used to verify the proposed metamaterial's differential-/common-mode characteristics. The metamaterial is integrated with a balanced mixer design resulting in an operation frequency range of $1.96{\sim}2.40$ GHz with an optimum mixer conversion loss of 21.1 dB at 2,4 GHz.

129 GHz SIS MIXER RECEIVER FOR KOREAN VLBI NETWORK (한국우주전파관측망 129 GHz 초전도 믹서 수신기)

  • Lee, Jung-Won;Wang, Ming-Jye;Li, Chao-Te;Chen, Tse-Jun;Kim, Soo-Yeon;Lu, Wei-Chun;Kang, Yong-Woo;Shi, Sheng-Cai;Han, Seog-Tae
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.3
    • /
    • pp.71-80
    • /
    • 2012
  • We have developed superconducting mixer receivers for 129 GHz VLBI observation in Korean VLBI Network (KVN). The developed mixer has a radial waveguide probe with simple transmission line L-C transformer as a tuning circuit to its 5 series-connected junctions, which can have 125 - 165 GHz as the operation radio frequency (RF). For intermediate frequency (IF) signal path a high impedance quarter-wavelength line connects the probe to one end of symmetric RF chokes. The double side band (DSB) receiver noise of the mixer was about 40 K over 4 - 6 GHz IF band, whereas we achieved the uncorrected single side band (SSB) noise temperature of about 70 K and better than 10 dB image rejection ratio in 2SB configuration with 8 - 10 GHz IF band. Insert-type receiver cartridges employing the mixers have been under commission for KVN stations.

94-GHz Single Balanced Mixer (94 GHz Single-Balanced 믹서의 설계 및 제작에 관한 연구)

  • Hong, Seung-Hyun;Lee, Mun-Kyo;Lee, Sang-Jin;Baek, Tae-Jong;Han, Min;Baek, Young-Hyun;Choi, Seok-Gyu;Rhee, Jin-Koo
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.411-412
    • /
    • 2008
  • The high performance 94 GHz MMIC(Monolithic Micro-wave Integrated Circuit) single balanced mixer was designed and fabricated, using MHEMT structure based diodes and a CPW(Coplanar Waveguide) tandem coupler. A novel single-balanced structure of diode mixer is proposed in this work, where a 3-dB tandem coupler with two section of parallel-coupled line. Implemented air-bridge crossover structures achieve wide frequency operation and the fabricated mixer exhibits excellent LO-RF isolation, larger than 30 dB, in the 5 GHz bandwidth of 91-96 GHz. A good conversion loss of 7.4 dB is measured at 94 GHz. The proposed MHEMT-based diode mixer shows superior LO-RF isolation and conversion loss to those of the W-band mixers reported to date.

  • PDF

Statistical process control of dye solution stream using spectrophotometer

  • Lee, Won-Jae;Cho, Gyo-Young
    • Journal of the Korean Data and Information Science Society
    • /
    • v.21 no.6
    • /
    • pp.1289-1303
    • /
    • 2010
  • The need for statistical process control to check the performance of a process is becoming more important in chemical and pharmaceutical industries. This study illustrates the method to determine whether a process is in control and how to produce and interpret control charts. In the experiment, a stream of green dyed water and a stream of pure water were continuously mixed in the process. The concentration of the dye solution was measured before and after the mixer via a spectrophotometer. The in-line mixer provided benefits to the dye and water mixture but not for the stock dye solution. The control charts were analyzed, and the pre-mixer process was in control for both the stock and mixed solutions. The R and X-bar charts showed virtually all of the points within control limits, and there were no patterns in the X-bar charts to suggest nonrandom data. However, the post-mixer process was shown to be out of control. While the R charts showed variability within the control limits, the X-bar charts were out of control and showed a steady increase in values, suggesting that the data was nonrandom. This steady increase in dye concentration was due to discontinuous, non-steady state flow. To improve the experiment in the future, a mixer could be inserted into the stock dye tank. The mixer would ensure that the dye concentration of the stock solution is more uniform prior to entering the pre-mixer ow cell. Overall, this would create a better standard to judge the water and dye mixture data against as well.

Determination of Optimal Coagulation Condition for Coagulation-UF Water Treatment Process (응집-UF 정수공정을 위한 칠적응집조건의 결정)

  • Lee, Chul-Woo;An, Su-Kyong;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.8
    • /
    • pp.799-806
    • /
    • 2005
  • Applying coagulation process before membrane filtration showed not only reducing membrane fouling, but also improving the removal of dissolved organic materials that might otherwise not be removed by the membrane alone. Also, slow mixing didn't affect the reduction of membrane fouling, and rapid mixing using an in-line static mixer was more effective than using backmixer. In addition, only 11 percent of dissolved organic matter in raw water was the primary cause of fouling. Furthermore, tile primary foulant of UF membrane was hydrophobic substance, which can easily be removed by coagulation.

study on twist forming of elements for tube type line mixers (튜브형 line mixer용 element의 비틀음 성형에 대한 연구)

  • 김권희
    • Transactions of Materials Processing
    • /
    • v.5 no.2
    • /
    • pp.165-175
    • /
    • 1996
  • the process of strip twisting is practiced for the manufacture of some commercial parts such as elements for tube type line mixers. A thin metal strip with rectangular cross section is twisted thru an angle greater than 180。. Initial geometry is altered in to a complex one with dimen-sional changes. In practice several tryouts are necessary to obtain required dimensional accu-racies. A simple analysis model is proposed to predict the dimensional changes forming torque and axial force.

  • PDF