• Title/Summary/Keyword: In-Direct Feeding

Search Result 180, Processing Time 0.034 seconds

Reliability Modeling of Direct Current Power Feeding Systems for Green Data Center

  • Choi, Jung Yul
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.704-711
    • /
    • 2013
  • Data center is an information hub and resource for information-centric society. Since data center houses hundreds to ten thousands servers, networking and communication equipment, and supporting systems energy saving is one of the hottest issues for green data center. Among several solutions for green data center this paper introduces higher voltage direct current (DC) power feeding system. Contrary to legacy alternating current (AC) power feeding system equipped with Uninterruptible Power Supply (UPS), higher voltage DC power feeding system is reported to be a more energy efficient and reliable solution for green data center thanks to less AC/DC and DC/AC conversions. Main focus of this paper is on reliability issue for reliable and continuous operation of higher voltage DC power feeding system. We present different types of configuration of the power feeding systems according to the level of reliability. We analyze the reliability of the power feeding systems based on M/M/1/N+1/N+1 queueing model. Operation of the power feeding system in case of failure is also presented.

Factors Associated with the Method of Feeding Preterm Infants after Hospital Discharge (퇴원 후 미숙아의 수유 유형과 영향요인)

  • Han, Soo-Yeon;Chae, Sun-Mi
    • Child Health Nursing Research
    • /
    • v.24 no.2
    • /
    • pp.128-137
    • /
    • 2018
  • Purpose: To investigate factors that may affect the method of feeding among preterm infants at 4 weeks after discharge. Methods: This study included 222 mother-infant dyads born before a gestational age of 37 weeks. The feeding method and general medical characteristics of the participants were assessed at 4 weeks after discharge using a structured questionnaire. Multinomial logistic regression analysis was used to examine which factors were associated with breastfeeding at home. Results: Of the 222 infants who qualified for the study, 71 (32.9%) continued to receive breastmilk at 4 weeks post-discharge. Multinomial logistic regression analysis showed that breastfeeding at 4 weeks post-discharge was associated with higher breastfeeding self-efficacy, vaginal delivery (experience), direct breastfeeding in the neonatal intensive care unit (NICU), gestational age between 30 and 34 weeks, and breastmilk consumption in the NICU. The following factors were associated with mixed feeding at 4 weeks post-discharge: being employed, having higher breastfeeding self-efficacy, and direct breastfeeding in the NICU. Conclusion: NICU nurses should provide opportunities for direct breastfeeding during hospitalization and support breastfeeding to enhance breastfeeding self-efficacy. These factors may help to ensure the continuation of breastfeeding after discharge. Moreover, factors that affect breastfeeding should be considered when providing interventions.

Design of Dual-Band GPS Array Antenna Using In-Direct Feeding Pad (간접급전 패드를 이용한 이중 대역 GPS 배열 안테나 설계)

  • Kang, Seung-Seok;Seo, Seung-Mo;Byun, Gangil;Choo, Hosung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.5
    • /
    • pp.355-365
    • /
    • 2017
  • In this paper, we propose the design of a dual-band GPS antenna using in-direct feeding pads. The antenna consists of an upper patch for the GPS L1 band, a lower patch for the GPS L2 band, and two pads on the middle layer for feeding the two radiating patches. A hybrid chip coupler with a phase difference of $90^{\circ}$ is employed at the two feeding ports for achieving a broad circular polarization (CP) bandwidth. The proposed antenna shows bore-sight gains of 3.0 dBic(L1) and 5.1 dBic(L2), and axial ratios of 3.3 dB(L1) and 0.3 dB(L2) by measurement. The active element patterns of the fabricated array with 7 elements show bore-sight gains of -0.4 dBic (L1) and -2.4 dBic(L2), respectively. It proves that the proposed antenna structure is suitable for use in GPS array applications.

A Survey on Management of the Foodservice Industry in Seoul following the Size of Feeding Group (급식규모에 따른 산업체 급식소의 운영실태 조사)

  • 이윤경
    • Journal of the Korean Home Economics Association
    • /
    • v.33 no.2
    • /
    • pp.151-157
    • /
    • 1995
  • This is a study on types of foodservice system, the menu, role of the Dietitian, management of the facilities and utensil through the survey conducted at 105 enterprises located in Seoul industrial foodservices which were evenly divided into three groups ; large size of feeding group, medium size of feeding group, small size of feeding group. The sresults are below, 1. Most institutional foodservice was enterprise under direct management. 2. Selective menu was set for the large size of feeding group than small size of feeding group. At budget making, personal management and purchansing management, the dietition role was not important in the large size of feeding group than in the small size of feeding group. 3. Equipped rate of facilities and utensil were greater volume for the large size of feeding group.

  • PDF

DEPOSITION CHARACTERISTICS OF HIGH-THERMAL-CONDUCTIVITY STEEL IN THE DIRECT ENERGY DEPOSITION PROCESS AND ITS HARDNESS PROPERTIES AT HIGH TEMPERATURES

  • JONG-YOUN SON;GWANG-YONG SHIN;KI-YONG LEE;HI-SEAK YOON;DO-SIK SHIM
    • Archives of Metallurgy and Materials
    • /
    • v.65 no.4
    • /
    • pp.1365-1369
    • /
    • 2020
  • Direct energy deposition (DED) is a three-dimensional (3D) deposition technique that uses metallic powder; it is a multi-bead, multi-layered deposition technique. This study investigates the dependence of the defects of the 3D deposition and the process parameters of the DED technique as well as deposition characteristics and the hardness properties of the deposited material. In this study, high-thermal-conductivity steel (HTCS-150) was deposited onto a JIS SKD61 substrate. In single bead deposition experiments, the height and width of the single bead became bigger with increasing the laser power. The powder feeding rate affected only the height, which increased as the powder feeding rate rose. The scanning speed inversely affected the height, unlike the powder feeding rate. The multi-layered deposition was characterized by pores, a lack of fusion, pores formed by evaporated gas, and pores formed by non-molten metal inside the deposited material. The porosity was quantitatively measured in cross-sections of the depositions, revealing that the lack of fusion tended to increase as the laser power decreased; however, the powder feeding rate and overlap width increased. The pores formed by evaporated gas and non-molten metal tended to increase with rising the laser power and powder feeding rate; however, the overlap width decreased. Finally, measurement of the hardness of the deposited material at 25℃, 300℃, and 600℃ revealed that it had a higher hardness than the conventional annealed SKD61.

Water management for vapor-fed direct methanol fuel cells (수동급기 직접 메탄올 연료전지의 공기극 물 관리)

  • Chang, Ik-Whang;Ha, Seung-Bum;Cha, Suk-Won;Lee, Yoon-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.319-322
    • /
    • 2009
  • This paper investigated environmental effects for passive, air-breathing, and vapor-feeding direct methanol fuel cells. In these experiments, experimental parameters are temperature($30^{\circ}C$, $40^{\circ}C$ and relative humidity(25%, 50%, 75%). From these experimental results, the water contents play a key role in terms of optimal ionic conductivity at the cathode catalyst layer. In case of pure methanol feeding, the performance is inversely proportional to the relative humidity. The water generation resulting from methanol crossover maintains ionic conductivity at the cathode. On the contrary, diluted methanol solution (50wt.%) lowers methanol crossover to the cathode. In order to increase ionic conductivity, the relatively high humidity is required to the cathode catalyst layer for the water generation. The relative humidity scales with the performance.

  • PDF

Effects of environmental temperature on the performance of direct methanol fuel cell for vehicles (외부온도가 수송용 메탄올연료전지 성능에 미치는 영향)

  • Han, Chang-Hwa;Jung, Dae-Seung;Choi, Ji-Sun;Han, Sang-Hun;Lee, Joong-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.176-179
    • /
    • 2009
  • The performance of direct methanol fuel cells is affected by operating conditions such as, methanol feeding temperatures, methanol concentrations, and methanol flow rates during the operation in different environmental conditions. In this study, effects of the environmental temperature on performance of direct methanol fuel cells have been investigated in order to test a applicability of direct methanol fuel cell to the vehicle. The environmental temperature (ET) was varied from $-20^{\circ}C$ to $+30^{\circ}C$. The inside fuel cell temperature (CT) during test at various operating conditions was monitored and the performance of fuel cell was measured in the I-V polarization curve. With increasing the ET, the performance of the fuel cell was significantly improved and the CT also almost linearly increased. However, at below $0^{\circ}C$ ET, the DMFC showed very poor performance and needed to control CT or methanol feeding temperature (MFT), methanol flow rate(MFR) to obtain enough power of the vehicle.

  • PDF

Comparison of Customer Satisfaction by Operation Types of Business Foodservice in Chungbuk Province (충북지역 사업체 급식소의 운영형태에 따른 고객 만족도 비교)

  • An, Kwang-Bok;Yon, Mi-Yong;Lee, Yu-Jin;Kim, Woon-Ju
    • Journal of the Korean Society of Food Culture
    • /
    • v.24 no.6
    • /
    • pp.721-727
    • /
    • 2009
  • In this study, the current status of the business foodservice industry, evaluation of leftover food and customer satisfaction with foodservice at direct operation and consignment foodservice businesses in Chungbuk were examined. This study has managerial implications in terms of improving the quality and effectiveness of the business operation of the foodservice industry. The sample size of this study included 800 customers who use foodservices provided by 11 selected businesses including 6 direct operation and 5 consignment foodservice businesses. From these 800 customers, a total of 692 were used (direct operation foodservice (n=361) and consignment foodservice (n=331) businesses). The results were as follows; First, as for the main reasons for using the employee restaurants in types of direct operation and consignment foodservice business, 'the close location' had the high percentage. Approximately 41% of respondents were not satisfied with the foodservice in the employee restaurants. Second, leftover food from consignment foodservices was higher than that for direct operation foodservices. Third, there were significant differences in customer satisfaction with five areas of foodservice between the two types of food service businesses: food, sanitation, feeding environment, mealing process and information and service. Customer satisfaction in the direct operation foodservice was higher than that of the consignment foodservice. In terms of the satisfaction level of foodservices, mealing process was the highest, followed by sanitation, food, and information and service in the direct operation and consignment foodservice businesses. Overall, satisfaction with the business foodservice was affected by the customers' satisfaction in five areas of foodservices (e.g., food, sanitation, feeding environment, mealing process, information and service). Especially, 'food' and 'information and service' were important areas for determining overall customer satisfaction with foodservice. In addition, the overall satisfaction was negatively correlated with the quantity of leftover food in the direct operation and consignment foodservice business.

Effect of Direct Breastfeeding Program for Premature Infants in Neonatal Intensive Care Unit (신생아집중치료실 미숙아를 위한 직접모유수유 프로그램의 효과: 비동등성 대조군 전후 설계)

  • Kang, Ji Hyun;Son, Hyunmi;Byun, Shin Yun;Han, Gyumin
    • Journal of Korean Academy of Nursing
    • /
    • v.51 no.1
    • /
    • pp.119-132
    • /
    • 2021
  • Purpose: This study aimed to identify the effects of a direct breastfeeding program for premature infants in neonatal intensive care units (NICUs). Methods: This quasi-experimental study was conducted during August 2016 to April 2017. Sixty mothers of premature infants were assigned to the experimental (n = 31) or control groups (n = 29). The program was comprised of breastfeeding education and direct breastfeeding support. The experimental and control groups were provided with education and counseling on breastfeeding at the time of admission and discharge. In the experimental group, the mothers initiated oral feeding with direct breastfeeding and engaged in breastfeeding at least seven times during the NICU stay. The collected data were analyzed by the χ2-test and repeated measures ANOVA using an SPSS program. Results: The experimental group showed a higher direct breastfeeding practice rate (χ2 = 19.29, p < .001), breastfeeding continuation rate (χ2 = 3.76, p < .001), and self-efficacy (F = 25.37, p < .001) than the control group except for maternal attachment. Conclusion: The direct breastfeeding program in the NICU has significant effects on the practice and continuation rate of breastfeeding and breastfeeding self-efficacy. Therefore, this program can be applied in the NICU settings where direct breastfeeding is limited.

Comparison of Dust Exposure Levels among Farmers with and without Feeding (사료 급이 유무에 따른 돈사 작업자의 분진 노출량 비교)

  • Paik, Jong Min;Kim, Ki Youn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.2
    • /
    • pp.103-107
    • /
    • 2013
  • Objectives: The principal purpose of this study is to statistically compare dust levels among farmers with and without feeding in a nursery pig building. Methods: Total dust and respirable dust were measured by personal sampling method, and TSP and PM10 were monitored by the direct recording method in the pig building. Results: IIn the personal samples, mean exposure levels of total and respirable dust were higher among the farmers who conducted feeding compared to farmers who did not. A significant difference between farmers with feeding and farmers without feeding was found in total dust concentration(p<0.05), whereas there was no significant difference in respirable dust concentrations. In real-time monitoring of dust based on area sampling, the highest levels of total and respirable dust were detected in the feeding time periods; $4.33{\pm}2.57mg/m^3$ for TSP and $2.53{\pm}1.02mg/m^3$ for PM10, respectively. During time periods without feeding, the levels of total and respirable dust ranged from 1 to $2mg/m^3$ and from 0.5 to $1.5mg/m^3$, respectively. Conclusions: In terms of association of feeding work and air sampling location, the mean concentrations of total and respirable dust were highest in area sampling with feeding and lowest in personal sampling without feeding. However, a significant difference among groups investigated according to air sampling condition was found in total dust.