• 제목/요약/키워드: In-Ceram

검색결과 145건 처리시간 0.023초

지르코니아 코아가 전부도재관의 색조에 미치는 영향에 대한 분광측색분석 (SPECTROPHOTOMETRIC ANALYSIS OF THE INFLUENCE OF ZIRCONIA CORE ON THE COLOR OF CERAMIC)

  • 배아란;백진;우이형;김형섭;최대균
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.466-477
    • /
    • 2005
  • Statement of problem : Problem of matching the appearance of porcelain restorations with the patient's natural dentition has always been a concern to dental clinicians. Recently, demands for esthetics, even in restorations requiring strength, has brought a revolution to dentistry and increased use of zirconia. Among the various factors, shade and translucency or the core can significantly affect the overall esthetics of the restoration and should be considered when selecting an all-ceramic system. Purpose : The purpose of this study was to spectrophotometrically evaluate the influence of different zirconia systems and core thickness on the final shade of all-ceramic restorations using the CIEL$^*a^*b^*$ system. Material and Methods: Core specimens (n : 20 per group) of In-Ceram Alumina, In-Ceram Zirconia, Digident CAD/CAM Zirconia, Cercon Zirconia were fabricated 20mm in diameter. 10 specimens of each group were fabricated at core thickness of 0.5mm and 0.7mm. These core specimens were veneered with shade Al & A3 porcelain of the recommended manufacturer. CIEL$^*a^*b^*$ coordinates were recorded for each specimen with a spectrophotometer (Model CM-2600d, Minolta, Japan). Color differences were calculated using the equation ${\Delta}E^*=[({\Delta}L^*)^2+({\Delta}a^*)^2+({\Delta}b^*)^2]^{\frac{1}{2}}$. Results : 1. Specimens of core thickness 0.5mm and 0.7mm did not exhibit clinically perceived color difference. 2. Regarding shade reproducibility, In-Ceram Alumina and In-Ceram Zirconia showed significant difference within each group. 3. Cercon Zirconia group showed the highest $L^*$ value and Digident Zirconia group showed lowest $a^*$ & $b^*$ value. 4. Generally the shade difference between materials was higher in the A3 shade group than in the Al shade group. Conclusion: Within the limitations of this study, there was no color difference after increase in core thickness and every all-ceramic system has color characteristics that clinicians have to consider when selecting materials. Also, manufacturers of different porcelain systems must make every effort to achieve color reproducibility.

Rocatec system이 Zir-ceram과 간접복합수지간의 전단결합강도에 미치는 영향 (Effect of Rocatec system on Shear Bond Strength between Zir-Ceram and Sinfony Indirect Composite Resin)

  • 김동일;김부섭;정인성
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.23-29
    • /
    • 2008
  • The purpose of this study is to evaluate possibility of using indirect composite resin instead of porcelain through the measurement of shear bond strength between zirconia core and indirect composite resin under treatment of $Rocatec^{TM}$ system for improving the adhesion of indirect composite resin. 20 cylindrical zirconia core specimens were divided into 2 groups, according to zirconia surface treatment and attached materials: 1) treated with sandblast and attached with indirect composite resin, 2) treated with sandblast + $Rocatec^{TM}$ system and attached with indirect composite resin. The shear bond strength of each experimental group was measured by MTS and the changes of zirconia core surface according to surface treatments were obtained by SEM observation and measurements of surface roughness. The mean shear bond strength values are $0.55\;{\pm}\;0.11MPa$(Group SC) and $1.16\;{\pm}\;0.46MPa$(Group SRC). The mean Ra values for the surface treatments were follows: $0.39\;{\pm}\;0.13$($100{\beta}_{{\mu}m}$ sandblast) and $0.50\;{\pm}\;0.03$($100{\beta}_{{\mu}m}$ sandblast + $Rocatec^{TM}$ system). In the analysis of EDS, Si element was detected in the Group SC. The shear bond strength between zirconia core and indirect composite resin was improved significantly by using $Rocatec^{TM}$ system.

  • PDF

다양한 용액에 따른 Bulk-fill 복합레진의 색조안정성 평가 (Color Stability of Bulk-Fill Resin Composites after Immersion in Different Media)

  • 강성균;송지현
    • 대한소아치과학회지
    • /
    • 제46권4호
    • /
    • pp.353-361
    • /
    • 2019
  • 이 연구의 목적은 bulk-fill 복합레진과 전통적인 복합레진을 대상으로 다양한 용액과 시편의 두께에 따른 색조안정성의 차이를 평가하는 것이다. 전통적인 복합레진으로 Filtek™ Z250, Filtek™ Z350XT와, bulk-fill 복합레진으로 Filtek™ Bulk-fill Posterior Restorative, Tetric® N-Ceram Bulk Fill이 사용되었다. 각 복합레진 시편은 3개의 군으로 나누어 각각 증류수, 레드와인, 커피 용액에 침전시킨 뒤, 침전 1, 7, 28일에 색조 측정을 시행하여 각 시점과 초기 기준점의 CIE L*a*b*값의 색차(ΔE*)가 계산되었다. 모든 복합레진은 레드와인에서 가장 큰 색조변화가 나타났으며, 그 다음은 커피, 증류수 순서였다. Filtek™ Z350XT는 모든 용액에서 가장 큰 색조변화를 나타냈고, 다음은 Filtek™ Bulk-fill Posterior Restorative였다. 그 뒤로는 Filtek™ Z250과 Tetric® N-Ceram Bulk Fill이 유사한 수준의 색조변화를 나타냈다. Bulk-fill 복합레진에서 2 mm와 4 mm인 시편의 두께에 따른 색조변화의 차이는 나타나지 않았다.

Silorane-based 복합레진의 색안정성에 관한 연구 (COLOR STABILITY OF NEW SILORANE-BASED COMPOSITE RESIN: AN IN VITRO SPECTROPHOTOMETRIC STUDY)

  • 손유진;현홍근;김영재;김정욱;이상훈;김종철;한세현;장기택
    • 대한소아치과학회지
    • /
    • 제37권1호
    • /
    • pp.73-81
    • /
    • 2010
  • 본 연구의 목적은 silorane-based 복합레진의 색안정성을 기존의 methacrylate-based 복합레진과 비교하여 평가하는 것이다. Silorane-based 복합레진인 P90(3M ESPE, USA), methacrylate-based 복합레진인 Tetric Ceram(Ivoclar Vivadent, Liechtenstein), Z250, Z350(3M ESPE, USA)을 이용하여 시편을 제작하고, 증류수, 커피, 레드 와인, 카레 용액에 담가 1일, 3일, 7일, 14일, 21일, 28일 후 색 변화를 분광광도계로 측정하고 실험 전후의 색상차이(${\Delta}{E^*}_{ab}$)값을 산출하여 다음과 같은 결과를 얻었다. 1. 카레 용액 > 레드 와인 > 커피 > 증류수의 순으로 레진 시편의 변색이 크게 나타났다. 2. 네 가지 종류의 레진을 비교하였을 때, Z350 > Z250 > Tetric Ceram > P90의 순으로 변색이 크게 나타났다. 3. 카레 용액의 경우 네 종류의 레진 모두에서 침지 1일 이후 수용도 역치 이상(${\Delta}{E^*}_{ab}$>3.3)의 변색이 나타났다. 4. 레드 와인의 경우 Z350, Z250, Tetric Ceram에서 침지 1일 이후, P90에서는 침지 28일 이후에 수용도 역치 이상의 변색이 나타났다. 5. 커피의 경우 Z350에서 침지 1일 이후, Z250에서 침지 3일 이후, Tetric Ceram에서 침지 7일 이후에 수용도 역치 이상의 변색이 나타났으나 P90에서는 침지 28일 이후에도 수용도 역치 이상의 변색이 나타나지 않았다.

Ormocer 계열 수복재의 물성에 관한 연구 (SELECTED MECHANICAL PROPERTIES OF ORMOCER RESTORATIVE MATERIALS)

  • 이동수;정태성;김신
    • 대한소아치과학회지
    • /
    • 제29권3호
    • /
    • pp.362-370
    • /
    • 2002
  • 최근 20년간 다양한 종류의 심미 수복재가 개발되었고, 특히 지난 5년 동안에는 그 수에 있어서 극적인 증가추세를 보였다. 최근 들어, ormocer라는 새로운 종류의 광중합형 수복재료가 소개되었는데, 화학 분야에서는 이미 오래 전부터 알려져 있던 성분으로, 광학렌즈 등의 표면경화제로 이용되어 오다가 최근 치과용 수복재에 도입되었다. 'Ormocer' 란 'Organically Modified Ceramics'의 약자로 'Ormosils' (Organically Modified Silicates)로도 알려져 있다. 그러나, 이 새로운 수복재에 대한 연구는 아직 미흡한 실정이다. 본 연구에서는 서로 다른 계통의 광중합형 수복재들(Z-100, Surefil, Tetric Ceram, Dyract AP)과 ormocer(Admira)를 압축강도와 굴곡강도 측면에서 비교 평가하고, 구강내 환경과 유사한 조건에서 수분흡수가 그 물성에 미치는 영향을 평가할 목적으로 시도되어 다음과 같은 결과를 얻었다. 1. 1일 후에 측정한 Admira의 압축강도는 Surefil보다는 낮았으나, 다른 재료들과는 유의한 차이를 나타내지 않았다(p>0.05). 2. 1일 후에 측정한 Admira의 굴곡강도는 다른 4종의 재료에 비해서 낮았다(p<0.05). 2일부터는 3종의 복합레진에 비해서 낮았다(p<0.05). 3. 실험기간(30일) 중 hybrid composite resin군(Z-100, Tetric Ceram)과 packable resin(Surefil)군 간에는 압축강도와 굴곡강도에서 유의한 차이가 없었다(p>0.05). 4. 실험에 사용된 5종의 수복재 모두 압축강도와 굴곡강도가 2일까지 증가하다가 7일부터 감소하였다(p<0.05). 5. 각 재료의 시간에 따른 압축강도와 굴곡강도의 변화양상은 통계적으로 유사하였다(p>0.05).

  • PDF

Nanofilled 복합레진의 잔류응력 비교 (COMPARISON OF THE RESIDUAL STRESS OF THE NANOFILLED COMPOSITES)

  • 박정원
    • Restorative Dentistry and Endodontics
    • /
    • 제33권5호
    • /
    • pp.457-462
    • /
    • 2008
  • 중합수축이 일어난 후 복합 레진 내에는 중합수축에서 기원한 응력이 내부에 남아있을 수 있는데 이를 "잔류응력"이라 한다. 수복물에 가해지는 총힘은 외부에서 가해지는 힘과 내부에 남아있는 응력의 합으로 결정이 되며 수복물의 실패를 이해하기 위해서 이 두 가지 요소가 반드시 고려되어야 한다. 본 연구에서는 ring slitting방법을 이용하여 최근 임상에 소개된 나노충진형 복합레진간의 잔류응력을 비교하였다. 실험에 사용한 복합레진은 대조군으로 microhybrid-type인 Z250과 nanofiller를 함유한 Grandio, Filtek Supreme, Ceram-X를 이용하여 복합레진 링을 제작하고 2개의 기준점을 표시한 후 이 사이의 거리를 링 절단 전과 후에 각각 측정하여 거리 변화를 측정하였다. 거리의 변화로부터 average circumferential residual stress $({\sigma}{\theta})$를 계산하였다. 10분과 1시간 경과 후 측정한 군에서는 Filtek Supreme이 Z250이나 Ceram-X보다 높은 잔류응력을 보여 주었고, 24시간 경과한 군에서는 Filtek Supreme이 나머지 군보다 높은 잔류응력을 보여주었다. 본 실험 결과에 의하면 nanofiller를 함유한 복합레진의 잔류응력은 대조군으로 사용한 Z250보다 높거나 같은 값을 나타냈으며 거의 비슷한 기질조성을 가진 Z250과 Filtek Supreme을 비교했을 때 Filtek supreme이 모든 측정시간대에서 높은 잔류응력을 보여주었다.

지르코니아 코핑과 전장도재 간의 전단결합강도와 파절양상 비교 (A comparative study of the shear bond strength and failure mode between zirconia copings and veneering ceramics)

  • 김원영;전병욱;정인성
    • 대한치과기공학회지
    • /
    • 제37권4호
    • /
    • pp.243-250
    • /
    • 2015
  • Purpose: The aim of this study was to investigate the shear bond strength between various commercial zirconia coping and veneering ceramic, and to observe the failure mode. Methods: For each zirconia block (iJAM Emerald, LUXEN Smile block, ICE Zirkon transluzent), 10 rectangular specimens were layered with Cercon ceram kiss, IPS e.max ceram, ICE Zirkon ceramic according to recommended by the manufacturer. The shear bond strength tests of the veneering porcelain to zirconia were carried out until fracture by a universal testing machine. After the shear bond tests, failure modes were characterized visually, under a stereomicroscope, such as adhesive, cohesive, or mixed. Data were analyzed with One-way ANOVA followed by Scheffe's tests. Results: The shear bond strength ($mean{\pm}SD$) of zirconia-veneer ceramic were JC group $13.9{\pm}3.6MPa$; JE group $17.7{\pm}2.4MPa$; JI group $15.1{\pm}2.5MPa$; LC group $9.5{\pm}1.5MPa$; LE group $16.2{\pm}2.3MPa$; LI group $12.6{\pm}0.8MPa$; ZC group $16.0{\pm}2.3MPa$; ZE group $18.5{\pm}3.4MPa$; and ZI group $15.3{\pm}3.2MPa$. The One-way ANOVA showed a significant difference between groups (p<0.05). The failure mode in most experimental groups was mixed failure, except for the LC group, which showed adhesive failure, and JE group, LE group and ZE group showed cohesive failure. Conclusion: For IPS e.max ceram, the shear bond strength value was highest for all kinds of zirconia blocks. For ICE Zirkon transluzent, the shear bond strength value was highest for all kinds of veneering ceramics. Most of experimental group interfaces revealed mixed failure mode.

Effects of Microstructure on Thermoelectric Properties of $FeSi_2$

  • Park, Joon-Young;Song, Tae-Ho;Lee, Hong-Lim;Pai, Chul-Hoon
    • The Korean Journal of Ceramics
    • /
    • 제2권1호
    • /
    • pp.11-18
    • /
    • 1996
  • The variation of electrical conductively and Seebeck coefficient of FeSi2 according to the density of the specimen has been observed over the temperature range 50 to $700^{\circ}C$. A conventional pressureless sintering method with various sintering time (0, 0.5, 1, 5h) at $1190^{\circ}C$ and/or various sintering temperatures(1160, 1175, 1190, $1200^{\circ}C$) for 2 h was carried out to prepare $FeSi_2$ specimens having various densities. The relationship between the electrical conductivity and Seebeck coefficient was investigated after two steps of annealing (at $865^{\circ}C$ and then $800^{\circ}C$ for total 160h) and thermoelectric measurement. The electrical conductivity for the specimens showed a typical tendency of semiconductor, the average activation energy of which in the intrinsic region (above $300^{\circ}C$) was observed approximately as 0.452 eV, and increased slightly with density. On the other hand, the specimen of the lower density showed the higher value of Seebeck coefficient in the intrinsic region. As the temperature fell into the non-degenerate region, the highly densified specimen which had relatively little residual metal phase showed the higher value of Seeback coefficient. The power factor of all specimens showed the optimum value at $200^{\circ}C$. However, the power factor of the specimen of the lower density increased again from $400^{\circ}C$ and that of the higher dense specimen increased from $500^{\circ}C$. The power factor was more affected by Seebeck coefficient than electrical conductivity over all temperature range.

  • PDF

Repair bond strength of resin composite to bilayer dental ceramics

  • Ataol, Ayse Seda;Ergun, Gulfem
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권2호
    • /
    • pp.101-112
    • /
    • 2018
  • PURPOSE. The purpose of this study was to investigate the effect of various surface treatments (ST) on the shear bond strength of resin composite to three bilayer dental ceramics made by CAD/CAM and two veneering ceramics. MATERIALS AND METHODS. Three different bilayer dental ceramics and two different veneering ceramics were used (Group A: IPS e.max CAD+IPS e.max Ceram; Group B: IPS e.max ZirCAD+IPS e.max Ceram, Group C: Vita Suprinity+Vita VM11; Group D: IPS e.max Ceram; Group E: Vita VM11). All groups were divided into eight subgroups according to the ST. Then, all test specimens were repaired with a nano hybrid resin composite. Half of the test specimens were subjected to thermocycling procedure and the other half was stored in distilled water at $37^{\circ}C$. Shear bond strength tests for all test specimens were carried out with a universal testing machine. RESULTS. There were statistically significant differences among the tested surface treatments within the all tested fracture types (P<.005). HF etching showed higher bond strength values in Groups A, C, D, and E than the other tested ST. However, bonding durability of all the surface-treated groups were similar after thermocycling (P>.00125). CONCLUSION. This study revealed that HF etching for glass ceramics and sandblasting for zirconia ceramics were adequate for repair of all ceramic restorations. The effect of ceramic type exposed on the fracture area was not significant on the repair bond strength of resin composites to different ceramic types.

전부도재관의 변연 적합도 비교평가 (Comparative study in marginal accuracy of several all ceramic crowns)

  • 김정미;정수하
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.87-92
    • /
    • 2008
  • Purpose: In this study, we tried to compare marginal accuracy when produce ceramic crown using all ceramic materials and existent metal-ceramic system. Material and methods: All-ceramic systems were E-max (Ivoclar/Vivadent, Lichtenstein), Lava(3M, U.S.A.) and Wol-ceram(Teamziereis, Germany). Metal-ceramic system(PFG) was composed of Au-Pt alloy (Metalor, Switzerlandand) and overlying ceramic(D-sign, Ivoclar/Vivadent, Lichtenstein). We fabricated metal master die with upper diameter of 7.95mm, bottom diameter of 9.00mm, height of 5.00mm, and taper of $6^{\circ}$. All ceramic system used 0.5mm thickness ceramic coping, while metalceramic system used 0.3 thickness metal coping. By adding dentin and enamel ceramics on each coping, a crown with a proximal thickness of 1.0 mm and occlusal thickness of 2.0mm was fabricated. Pressure of 2kg was applied for 10 seconds on each crown with static load compressor. Before and after cementation, we measured the marginal gap at 4 points of each crown using optical microscope. The data was analyzed using a Student's t test and repeated-measures of analyses of variance(ANOVA) followed by a Bonferroni test. A p value<0.05 was considered significant. Results: As experiment results, marginal accuracy of wol-ceram and Lava is no good when compared with marginal accuracy of PFG. But marginal accuracy of E.max is good when compared with PFG. This result showed not significant. The marginal accuracy of E.max is good when compared with marginal accuracy of wol-ceram and Lava. Conclusion: The marginal accuracy of E.max is very good when compared with marginal accuracy of another group.

  • PDF