• 제목/요약/키워드: In-Building measurement

검색결과 1,289건 처리시간 0.025초

민간 건축현장 성과측정을 위한 감리보고서 활용성 분석 (Analysis of Supervisory Report for Performance Measurement in the Private Building Construction Sites)

  • 성유경;허윤경;이승우;유위성
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.217-218
    • /
    • 2022
  • Supervision work deals with important data necessary for the performance management on building construction sites in accordance with the Building Act. Therefore, this study attempts to use the data from supervisory reports to measure the performance of private building projects. Performance measurement is important for systematic management. However, there are only a few cases in which performance measurement is performed because it requires strenuous efforts to collect data for measurement. First, this study derived 6 performance areas and 15 indicators through a few rounds of expert group discussions. Then, we confirmed the performance indicators with high feasibility of data collection through a survey of supervision experts. It is expected that the data of supervisory reports can measure systematically performance and assist in speedy diagnosis of private building construction sites.

  • PDF

The Use of Advanced Optical Measurement Methods for the Mechanical Analysis of Shear Deficient Prestressed Concrete Members

  • Wilder, K. De;Roeck, G. De;Vandewalle, L.
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권2호
    • /
    • pp.189-203
    • /
    • 2016
  • This paper investigates on the use of advanced optical measurement methods, i.e. 3D coordinate measurement machines (3D CMM) and stereo-vision digital image correlation (3D DIC), for the mechanical analysis of shear deficient prestressed concrete members. Firstly, the experimental program is elaborated. Secondly, the working principle, experimental setup and corresponding accuracy and precision of the considered optical measurement techniques are reported. A novel way to apply synthesised strain sensor patterns for DIC is introduced. Thirdly, the experimental results are reported and an analysis is made of the structural behaviour based on the gathered experimental data. Both techniques yielded useful and complete data in comparison to traditional mechanical measurement techniques and allowed for the assessment of the mechanical behaviour of the reported test specimens. The identified structural behaviour presented in this paper can be used to optimize design procedure for shear-critical structural concrete members.

좌표측정 센서시스템을 이용한 실험용 보의 처짐 계측 (Beam deflection measurement using coordinate sensor system)

  • 노태성;임홍철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.300-301
    • /
    • 2014
  • Measurement of beam deflection is a common procedure to determine proper behavior of the structure. Either LVDT (Linear Variable Displacement Transformer) or strain gauge is usually used in experiments. A newly developed coordinate reading measurement system can be also applied for the deflection measurements. In this study, an experimental measurement was made on a laboratory size beam specimen to examine the possibility of the use of such coordinate measurement system. Results have shown the possibility of utilizing the new system for beam deflection measurement.

  • PDF

Field monitoring of wind effects on a super-tall building during typhoons

  • Zhi, Lunhai;Li, Q.S.;Wu, J.R.;Li, Z.N.
    • Wind and Structures
    • /
    • 제14권3호
    • /
    • pp.253-283
    • /
    • 2011
  • This paper presents the field measurement results of wind effects on a super-tall building (CITIC Plaza, 391 m high) located in Guangzhou. The field data such as wind speed, wind direction and acceleration responses were simultaneously and continuously recorded from the tall building by a wind and vibration monitoring system during two typhoons. The typhoon-generated wind characteristics including turbulence intensity, gust factor, peak factor, turbulence integral length scale and power spectral density of fluctuating wind speed were presented and discussed. The dynamic characteristics of the tall building were determined based on the field measurements and compared with those calculated from a 3D finite element model of the building. The measured natural frequencies of the two fundamental sway modes of the building were found to be larger than those calculated. The damping ratios of the building were evaluated by the random decrement technique, which demonstrated amplitude-dependent characteristics. The field measured acceleration responses were compared with wind tunnel test results, which were found to be consistent with the model test data. Finally, the serviceability performance of the super-tall building was assessed based on the field measurement results.

초고층건물의 기둥축소량 예측, 계측 및 보정 (Prediction, Field Measurement and Compensation of Column Shortening in Tall Building)

  • 조석희;김한수;김도균
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.143-146
    • /
    • 2003
  • Tall Buildings have been popular in recent years. Tall buildings require special consideration to design and construction due to their structural features. Column shortening is one of the important technologies to be considered in. The long-term deformations of concrete cause vertical shortening on cores and columns, trigger deformations on cladding, partitions and finishes, and damage their serviceability. This also affects structural stability by inducing unexpected stress to the structural members such as outrigger. The main objective of this paper is to re-evaluate column shortening according to revised field information and to compare the analysis results with the actual field measurement. Mok-Dong Hyperion, a 69-story apartment building which is currently under construction, was chosen for the case study.

  • PDF

겉보기 비저항 측정에서 철근과 전극배치의 상대적 영향 분석 (Analysis of the Relative Effect of Rebar and Electrode Arrangement in the Measurement of Spparent Resistivity)

  • 임영철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.317-318
    • /
    • 2021
  • The effect of reinforcing bars embedded in concrete varies depending on the position of the electrode in the electrical resistivity measurement. In this study, the apparent resistivity according to the electrode arrangement is analyzed for each measurement angle. Through this, it is intended to be used to improve the accuracy of measurement in the concrete resistivity.

  • PDF

Health Monitoring of High-rise Building with Fiber Optic Sensor (SOFO)

  • Mikami, Takao;Nishizawa, Takao
    • 국제초고층학회논문집
    • /
    • 제4권1호
    • /
    • pp.27-37
    • /
    • 2015
  • Structural health monitoring is becoming more and more important in the domain of civil engineering as a proper mean to increase and maintain the safety, especially in the land of earthquakes like Japan. In many civil structures, the deformations are the most relevant parameter to be monitored. In this context, a monitoring technology based on the use of long-gage fiber optic deformation sensor, SOFO is being applied to a 33-floors tall building in Tokyo. Sensors were installed on the $2^{nd}$ floor's steel columns of the building on May 2005 in the early stage of the construction. The installed SOFO sensors were dynamic compatible ones which enable both static and dynamic measurements. The monitoring is to be performed during the whole lifespan of the building. During the construction, static deformations of the columns had been measured on a regular basis using a reading unit for static measurement and dynamic deformation measurements were occasionally conducted using a reading unit for dynamic measurement. The building was completed on August 2006. After the completion, static and dynamic deformation measurements have been continuing. This paper describes a health monitoring technology, SOFO system which is applicable to high-rise buildings and monitoring results of a 33-floors tall building in Tokyo from May 2005 to October 2010.

37층 초고층주상복합건물 SRC기둥의 기둥축소량 현장계측 및 보정법 (Field Measurement and Compensation Method of Column Shortening for SRC Columns in 37-story Residential Building)

  • 송화철;도근영;조훈희
    • 한국건축시공학회지
    • /
    • 제5권4호
    • /
    • pp.145-152
    • /
    • 2005
  • Long-term axial shortening of the vertical elements of tail buildings results in differential movements between two elements and may lead to the additional moments of connection beam and slab elements, and other secondary effects, such as cracks of partitions or curtain walls. Accurate prediction of time-dependent column shortening is essential for tall buildings from both strength and serviceability aspects. The compensation method is different from reinforced concrete and SRC(Steel Reinforced Concrete) members. The SRC columns are usually compensated according to total differential shortening between two vertical elements. In this study, column shortenings of 37-story W building under construction are predicted and compensated. The SRC column shortenings are compared with the actual column shortening by field measurement and the column shortenings are reanalysed and recompensated.

Probabilistic characteristics of damping in buildings

  • Fang, J.Q.;Li, Q.S.;Jeary, A.P.;Liu, D.K.;Wong, C.K.
    • Wind and Structures
    • /
    • 제2권2호
    • /
    • pp.127-131
    • /
    • 1999
  • This paper describes probabilistic characteristics of damping in a tall building based on the results of full-scale measurement. It is found, through statistical analysis of the damping data, that the probability density function(PDF) of damping at the high amplitude plateau can be well represented by Normal distribution (Gaussian distribution). A stochastic damping model is proposed to estimate amplitude-dependent damping for practical application.

공정-원가 통합관리를 위한 진도관리 개선 방안 (A Study on the Improvement of Construction Progress Management for EVMS)

  • 이규현;박찬정;최인성
    • 한국건축시공학회지
    • /
    • 제2권3호
    • /
    • pp.155-162
    • /
    • 2002
  • The Ministry of Construction-Transportation released a plan about EVMS in 1993 in order to prepare measures for an efficient public construction project, and prepared an enforcement proposal concretely in June for 2000 years, and have enforce a public project by an example with a target. Therefore, accurate analysis and evaluation about field progress are required for efficient management of a building construction, and must be established building construction management system for fast action about a problem However, unified management cannot be consisting because a work progress system is different from details estimate system within a country. and There is not still a definite standard in progress measurement for an application of EVMS. A purpose of this study is to present an improvement about a problem of progress measurement for an application of EVMS. The contents of a study, inquired into a progress measurement method and a standard to use in the field of a public construction and private construction and Checks a problem and presented an improvement item necessary for and is as follows. $\circled1$ must establishes a control account and progress measurement standard. $\circled2$ must manage progress in a activity viewpoint. $\circled3$ must use an accurate CPM process management technique.