• Title/Summary/Keyword: Impulse equipment

Search Result 86, Processing Time 0.03 seconds

High Density Impulse Noise Reduction Filter Algorithm using Effective Pixels (유효 화소를 이용한 고밀도 임펄스 잡음 제거 필터 알고리즘)

  • Cheon, Bong-Won;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.10
    • /
    • pp.1320-1326
    • /
    • 2018
  • Digital video equipment is important in the 4th industrial revolution and is widely used in different fields for various purpose. Data of digital video equipment is exposed to noise due to different reasons including user environment and processing and such noise affect output and processing method. This can even cause error, resulting in decreased reliability of the equipment. In this research, it offers algorithm to effectively recover video by removing noise and impulse noise occurring during the process of channel delivery. This proposed algorithm recovers video by exploring valid pixel using directional local mask and noise determination. Then, valid pixel calculated goes through the final output calculation through comparative analysis on estimation. For comparing suggested method and algorithm, simulation is carried out. For checking the function of it, PSNR and profile are analyzed.

Electrical Breakdown Characteristics of N2 Gas under Impulse Voltages (임펄스전압에 대한 N2가스의 절연파괴특성)

  • Shin, Hee-Kyoung;Kim, Dong-Kyu;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.131-136
    • /
    • 2011
  • This paper aims to examine the possibility of using an environmentally friendly $N_2$ as an alternative gas to $SF_6$. For this purpose, we have investigated breakdown characteristics of $N_2$ under impulse voltages in a quasi-uniform electric field gap. The 1.2/50[${\mu}s$] lightning impulse voltage, switching impulse voltages and oscillatory impulse voltages were applied at the test gap. The electric field utilization factor ranges from 0.5 to 0.8. The experimental data of $SF_6$ and $N_2$ acquired in the same experimental condition are presented in parallel for comparison. As a result, the breakdown voltages in $SF_6$ and $N_2$ are linearly increased with the gas pressure, also the breakdown voltages in $N_2$ are increased with increasing the gap distance and electric field utilization factor. The positive breakdown voltages are higher than the negative breakdown voltages. The nagative basic lightning impulse withstand level of 150[kV] in $N_2$ of about 0.5[MPa] is nearly equal to that in $SF_6$ of 0.15[MPa]. It is seen from the results obtained in this work that $N_2$ can be used as an eco-friendly alternative gas to $SF_6$ in distribution power equipment.

Life Analysis of High Pressure Hydraulic Hose Assemblies by Impulse Test (충격압력을 이용한 고압용 유압호스 조립체의 수명분석)

  • Lee Y.B.;Kim H.E.;Yoo Y.C.;Park J.H.;Ko J.M.;Kwak D.H.;Lee J.K.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.1 no.1
    • /
    • pp.10-16
    • /
    • 2004
  • The failures such as leakage and burst stemmed from the repetitive motions of bending and stretching of the assembly of hydraulic hose in construction machines, agriculture machines, vehicles, and industrial heavy machines can induce big troubles. Therefore, the hydraulic hose itself eventually requires an estimation of life to operate the hydraulic system safely. In this research, we have qualitatively selected the efficient test items by the analysis of the life and potential failures of hydraulic hose. We have used more than seven of hydraulic hoses simultaneously for the research. We have applied impulse pressure and half omega flexing motions to the accelerated life testing Test results have been expressed by employing weibull plot.

  • PDF

An Analysis of the Ground Surface Potential Rise and Hazardous Voltages Caused by Impulse Currents (임펄스전류에 의한 대지표면전위상승 및 위험전압의 분석)

  • Lee, Bok-Hee;Lee, Kyu-Sun;Choi, Jong-Hyuk;Seong, Chang-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.117-123
    • /
    • 2011
  • Lightning and switching surges propagating through the grounding conductors lead to transient overvoltages, and electronic circuits in information technology systems are very susceptible to damage or malfunction from the electrical surges. Surge damages or malfunctions of electrical and electronic equipment may be caused by potential rises. To solve these problems, it is very important to evaluate the ground surface potential rises and hazardous voltages such as touch and step voltages at or near the grounding systems energized by electrical surges. In this paper, the performance of grounding systems against the surge current containing high frequency components on the basis of the actual-sized tests is presented. The ground surface potential rises and hazardous voltages depending on impulse currents for vertical or horizontal grounding electrodes are measured and analyzed. Also the touch and step voltages caused by the impulse currents are investigated. As a result, the ground surface potential rises, the touch and step voltages near the grounding electrodes are raised and the conventional grounding impedances are increased as the front time of the injected impulse currents is getting faster.

Structural Vibration Analysis of Electronic Equipment for Satellite under Launch Environments (발사환경에 대한 위성 전장품의 구조진동 해석)

  • 정일호;박태원;한상원;서종휘;김성훈
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.8
    • /
    • pp.120-128
    • /
    • 2004
  • The impulse between launch vehicle and atmosphere can generate a lot of noise and vibration during the process of launching a satellite. Structurally, the electronic equipment of a satellite consists of an aluminum case containing PCB. Each PCB has resistors and IC. Noise and vibration of the wide frequency band are transferred to the inside of fairing, subsequently creating vibration of the electronic equipment of the satellite. In this situation, random vibration can cause malfunctioning of the electronic equipment of the device. Furthermore, when the frequency of random vibration meets with natural frequency of PCB, fatigue fracture may occur in the part of solder joint. The launching environment, thus, needs to be carefully considered when designing the electronic equipment of a satellite. In general, the safety of the electronic equipment is supposed to be related to the natural frequency, shapes of mode and dynamic deflection of PCB in the electronic equipment. Structural vibration analysis of PCB and its electronic components can be performed using either FEM or vibration test. In this study, the natural frequency and dynamic deflection of PCB are measured by FEM, and the safety of the electronic components of PCB is evaluated according to the results. This study presents a unique method for finite element modeling and analysis of PCB and its electronic components. The results of FEA are verified by vibration test. The method proposed herein may be applicable to various designs ranging from the electronic equipments of a satellite to home electronics.

Characterization and Analysis of UWB Antennas in Time Domain (시간 영역에서의 초광대역 안테나 특성 해석)

  • Song Jong-Hwa;Park Young-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.3 s.106
    • /
    • pp.287-294
    • /
    • 2006
  • In the paper, characterization and analysis of UWB(Ultra Wide Band) antennas in time domain are described. The impulse propagation channel including UWB antennas is proposed for the analysis in time domain. Using the proposed propagation channel, the technique of obtaining impulse response of UWB antenna is proposed. Also, ringing, peak value of the impulse response, and the width of the impulse response are introduced as parameters for characterizing a UWB antenna in time domain. A modified UWB conical monopole antenna, a UWB TEM horn antenna, and a UWB stepped fat monopole antenna were fabricated. From the measurement of reflection coefficients, three antennas had bandwidth more than 3 GHz. The impulse responses of the antennas were measured in an anechoic chamber. The results showed that the TEM horn with highest gain has the highest peak amplitude and the stepped fat monopole antenna with narrowest bandwidth for reflection coeffcient had the widest width of the impulse response. Also, ringing in the stepped fat monopole antennas and the UWB conical monopole antenna were observed.

The Influence of Trunk Rotation Exercise and PNF Exercise on Gait in the Individuals with Malalignment Syndrome (체간 양측성 회전 운동과 PNF 운동이 부정렬 증후군을 가진 성인의 보행에 미치는 영향)

  • Choi, Jae-Won;No, Hyun-Jeung
    • PNF and Movement
    • /
    • v.9 no.4
    • /
    • pp.49-55
    • /
    • 2011
  • Purpose : The aim of this study was to identify of bilateral trunk rotation(BTR) exercise and PNF exercise on gait in the individuals with malalignment syndrome. Methods : Subjects were 32 that were divided 2 groups in 20's generation. Interventions were trunk ratation exercise and PNF exercise. We used Medex for trunk rotation exercise. BTR group received exercise for three-sets (10min/set) along with stretching exercise ten-minutes, 3 times per week. PNF group took turns the D1 pattern in upper extremity and the D1 pattern in the opposite side of lower extremity for three-sets (10min/set). The measurement were force metatarsal 1 (FM 1), impulse metatarsal 1 (IM 1), force heel lat (FHL), impulse heel lat (IHL) by using footscan (RS scan). Statistical method was repeated measurement of ANOVA and p value was 0.05. Results : BTR and PNF group were significantly different in time(FM 1, IM 1, FHL, IHL). As different of right/left, BTR and PNF exercise were significantly different in FM 1, IM 1, FHL. Conclusion : BTR exercise was good exercise for malalignment but needs expensive equipment, for example, Medex. PNF exercise doesn't need expensive equipment but good method in malalignment syndrome person for gait ability. If PNF exercise is more experiment, PNF exercise could use variety for more patients.

Electric power system effect investigation of large size digital signal accident thought in digital age (디지털시대의 대형사고의 전기적 영향 고찰)

  • Kang, Tae-Keun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.575-580
    • /
    • 2004
  • The latest equipment automatic Intelligence of digital base done large size equipment appear in succession. That run by voltage electric current(mA, mV, ${\mu}A,\;{\mu}V$) that outline is microscopic of action of accuracy large size equipment of this digital base is bulk. Have received influence that is great in river electric field by installment that use computer. Most of domestic working voltage from service entrance extra-high voltage and working voltage of commercial frequency 60Hz working voltage 220V that use our country outside 1 country in interior of 22.900V for semiconductor use computer use digital installment of appliance as well as various smalls of digital base, middle, large size that safety is these fine voltage electric current that is not enough direct admonition hundred vast damage give can. Also, already act in surge circle and impulse transient phenomena such as several thousands, myriads, strong bit error more than billions time to digital fine electronic circuit by mistake use of using electric facility system of system electric power.

  • PDF

A Study on the Shock Absorption Performance of the Safety Helmet using Coefficient of Restitution (반발계수를 이용한 안전모의 충격 흡수 성능에 관한 연구)

  • Shin, Woon-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.30-34
    • /
    • 2012
  • A safety helmet is a personal protective equipment to protect the head from falling and flying objects. A safety helmet has the maximum delivered impact force as shock absorption performance, the lower delivered impact force the better performance, which was not a controlled variety during manufacturing safety helmet. Accordingly there were some difficulties in establishing the standard for improved performance as there was not a clear controllable impact force for improved performance. In this study the shock absorption performance was intended to be found as coefficient of restitution related to impulse. As a research method, a coefficient of restitution during the absorption of shock was calculated using the impulse transferred to pharynx utilizing the safety helmet shock absorption performance testing device based on the theory of momentum and impulse. The estimated impulsive force curve was derived assuming that shock was not absorbed using the measured data. The sample was selected as tested goods of ABS material for safety certification available mainly in the market. As a result of study, the maximum delivered impact force of safety helmet made by a domestic safety certified a company was 735 N, and its coefficient of restitution proved to be 0.64. The smaller coefficient of restitution is, the lower maximum delivered impact force and the higher shock absorption performance. The coefficient of restitution can be used as a performance index of safety helmet.