• 제목/요약/키워드: Impulse equipment

검색결과 86건 처리시간 0.032초

조명기기의 임펄스내전압 성능의 분석 (Analysis of Impulse Withstand Voltage Performance of Lighting Equipment)

  • 이복희;방평호
    • 조명전기설비학회논문지
    • /
    • 제28권3호
    • /
    • pp.91-96
    • /
    • 2014
  • Modern electronic circuits are becoming more vulnerable to damage by surges, and it is required to improve the impulse withstand voltage performance of electrical and electronic equipment. This paper presents the impulse withstand voltage performance of lighting equipment connected to power lines, and the impulse withstand voltage tests for fluorescent lamp, LED lamp and halogen lamp were carried out according to the reference standards under normal service conditions. To conduct performance tests against lightning surge, a combination wave ($1.2/50{\mu}s$ voltage - $8/20{\mu}s$ current) was employed. The test surge was applied between lines or between line and ground of the specimen to be measured. The test surge was applied synchronized at the peak value of the positive and negative AC voltage waves. As a consequence, some specimens satisfied the impulse withstand voltage test criteria, but lighting equipment such as 36W fluorescent lamps, 5W and 5.5W LED lamps and 50W halogen lamp were damaged at the test voltage levels between power lines. It is needed to improve the qualities of lighting equipment to satisfy EMC immunity requirements of equipment for general lighting purposes.

유압 피팅 충격압시험기 개발 (Hydraulic fitting impulse tester development)

  • 김형의;이용범
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.917-921
    • /
    • 1991
  • Hydraulic fitting impulse tester is equipment which produce impulse pressure waveform that specified foreign standard of SAE, JIS etc. Test conditions of SAE J1453 about waveform standard indicates frequency of 35-70 cycle/min, pressure of 560 bar, oil temperature of 93 .+-.3.deg. C etc. and required cycle is a million over. In additions, Test condition operated continuously equipment. This development item adopted new pattern method such as intensifier and rotary distributor is different from already established fitting impulse tester applied servo valve and high pressure direct directional control valve. Therefore, this development item which compares already established item is good reliability, low cost of manufacture and save of electric energy. especially, Domestic small and medium enterprise uses this tester because of economical cause. We develope appropriateness tester which conforms to demand of user.

  • PDF

Impulse Breakdown Behaviors of Dry Air as an Alternative Insulation Gas for SF6

  • Li, Feng;Yoo, Yang-Woo;Kim, Dong-Kyu;Lee, Bok-Hee
    • 조명전기설비학회논문지
    • /
    • 제25권3호
    • /
    • pp.24-32
    • /
    • 2011
  • [ $SF_6$ ]gas, which has an excellent dielectric strength and interruption performance, is used in various applications such as gas insulated switchgear (GIS) in substations. However, since $SF_6$ has a high global warming potential (GWP), it is necessary to find an eco-friendly alternative insulation gas. In order to examine the possibility of using alternative insulation gases for $SF_6$ in power distribution system equipment, the dielectric strength and physical phenomena of dry air in a quasi-uniform electric field are investigated experimentally in this paper. As a result, the breakdown voltages for positive polarity are higher than those for negative polarity under impulse voltage applications. The negative 50[%] flashover voltage, $V_{50}$ of dry air under conditions above 0.4[MPa] gas pressure, is higher than 150[kV], that is the basic impulse insulation level of distribution equipment. The $V_{50}$ increases linearly with increasing the gas pressure, regardless of the waveform and polarity of the applied impulse voltages. The voltage-time curves are dependent on the rise time of the impulse voltage and gas pressure. Furthermore, streamer discharge was observed through light emission images by an ICCD camera under impulse voltage applications.

뇌임펄스전압에 대한 SF6와 dry-air의 절연특성 (Dielectric Characteristics of SF6 and Dry-Air Gases under Lightning Impulse Voltage)

  • 이봉;유양우;김동규;이복희
    • 조명전기설비학회논문지
    • /
    • 제24권8호
    • /
    • pp.142-149
    • /
    • 2010
  • 본 논문은 준평등전계에서 뇌임펄스전압에 대한 $SF_6$와 dry-air의 절연파괴 특성에 대하여 기술하였다. 준평등전계로 사용된 구-평판전극계의 전계이용률은 71[%]이다. $SF_6$는 0.1~0.2[MPa] 범위에서, dry-air는 0.2~0.6[MPa]에서 $SF_6$와 dry-air의 절연파괴전압을 임펄스전압의 극성과 가스압력에 따라 측정 분석하였다. 그 결과 뇌임펄스전압에 대한 두 가스의 절연파괴전압은 정극성이 부극성보다 높았으며, $SF_6$의 절연파괴전압이 dry-air의 절연파괴전압보다 약 2.67배정도 높았다. 본 연구결과는 뇌서지에 대하여 우수한 성능을 가지는 배전기기에서 $SF_6$의 대체가스 성능 평가에 유용한 정보가 될 것이다.

전파 뇌충격전압 측정용 표준 저항분압기의 개발 (Development of Standard Resistor Divider for Full Lightning Impulse Voltage)

  • 김익수;문인욱;김민규;김영배;김진기;이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1633-1635
    • /
    • 1994
  • This paper presents the development technology of standard resistor divider for full lightning impulse voltage. The ability of high voltage bulk power equipment to withstand lighting stroke is usually evaluated by means of full lightning impulse voltage. Lightning impulse voltage test has been essential to evaluate the insulation performance of electrical power apparatus. Recently International standard (IEC 60) on high voltage measurement techniques is being revised and requests a formal traceability of high voltage measurements. Therefore, general interest for this area has grown considerably during last years, and several international intercomparisions have been completed already worldwide, i.e. Europe, Japan, America etc.. In this viewpoint, we have also investigated the standard resistor divider with shield, which satisfies the IEC recommendation.

  • PDF

PoE(Power Over Ethernet)에서 임펄스성 서지보호 이중화 장치 설계 (Design on a Dual Impulse Surge Protector for the Power over Ethernet Devices)

  • 진종호;김영진;이영철
    • 한국전자통신학회논문지
    • /
    • 제10권8호
    • /
    • pp.927-934
    • /
    • 2015
  • 본 논문에서는 산업현장에서 자연현상에 의하여 발생하는 임펄스성 서지(surge)에 의한 PoE(Power Over Ethernet)시스템의 통신 장애를 예방하기 위하여 이중화된 임펄스성 서지 보호회로를 설계하여 PoE 통신설비의 임펄스성 서지의 대책 방안을 제안하였다. PoE에 따른 임펄스성 서지신호의 특성을 분석하기 위하여 국제표준 IEC 61000-4-5에 적합한 서지 발생장치를 개발하였으며 서지 발생장치를 PoE 데이터 전송 라인에 인가하여 설계 제작한 이중화된 PoE 전원공급 보호회로에 의하여 순차적으로 임펄스성 서지 신호가 약화됨을 확인하였다.

DMB 시스템에서 UWB 전파가 서비스에 미치는 영향에 관한 연구 (A Study of Limitation of Service Area by UWB Transmission Jamming in DMB System)

  • 김동옥
    • 정보통신설비학회논문지
    • /
    • 제4권2호
    • /
    • pp.1-8
    • /
    • 2005
  • 본 논문에서는 UWB 시스템이 근처의 단일 장비 또는 집단 장비와의 간섭영향이 DMB 서비스에 미치는 영향에 관한 연구를 하였다. 이를 위해 UWB 시스템에서 방사되는 불요 방사 레벨에 따른 신호의 간섭을 비롯한 전파 간섭 특성이 인접 대역인 2.6425GHz SDMB(Satellite Digital Multimedia Broadcasting)와, In-band 대역인 3.4125GHz 방송 중계망과 서비스에 미치는 간섭 영향의 정도를 비교 분석하였으며, 방송 중계망과 간섭 측정 장비의 변조방식은 Impulse 방식과 OFDM 방식을 사용하였다. SDMB 시스템에서 Impulse 방식은 2m 지점에서부터 간섭 영향이 발생하여 1.4m 지점에서 방송 신호 수신이 가능한 $BER=1{\times}10^4$ 이었으며, OFDM 방식은 0.8m 지점에서부터 간섭 영향을 받아 0.5m 지점에서 방송 신호 수신이 가능한 $BER=1{\times}10^4$ 이었다. 또한 Gap-Filler 중심 주파수에 대해서는 0.01m 이상 이격 시는 간섭영향이 없었다. 따라서 소출력인 UWB 시스템의 전파가 DMB 서비스에 간섭 영향 없이 시스템에 적용하기 위해서는 Impulse 방식의 UWB 시스템보다 OFDM 방식의 UWB 시스템이 간섭 영향이 적다는 것을 확인하였다.

  • PDF

방송통신 시스템에서 UWB 전파가 서비스에 미치는 영향에 관한 연구 (A Study of Limitation of Service Area by UWB Transmission Jamming in Broadcasting Communication System)

  • 박노진
    • 정보통신설비학회논문지
    • /
    • 제7권1호
    • /
    • pp.23-31
    • /
    • 2007
  • 본 논문에서는 UWB 시스템이 근처의 단일 장비 또는 집단 장비와의 간섭영향이 방송통신서비스에 미치는 영향에 관한 연구를 하였다. 이를 위해 UWB 시스템에서 방사되는 불요 방사 레벨에 따른 신호의 간섭을 비롯한 전파 간섭 특성이 인접 대역인 2.6425GHz SDMB(Satellite Digital Multimedia Broadcasting)와, In-band 대역인 3.4125GHz 방송 중계망과 서비스에 미치는 간섭영향의 정도를 비교 분석하였으며, 방송 중계망과 간섭측정 장비의 변조방식은 Impulse 방식과 OFDM 방식을 사용하였다. SDMB 시스템에서 Impulse 방식은 2m 지점에서부터 간섭 영향이 발생하여 1.4m 지점에서 방송 신호 수신이 가능한 $BER\;=\;1{\times}\;10^{-4}$ 이었으며, OFDM 방식은 0.8m 지점에서부터 간섭 영향을 받아 0.5m 지점에서 방송 신호 수신이 가능한 $BER\;=\;1{\times}\;10^{-4}$ 이었다. 또한 Gap-Filler 중심 주파수에 대해서는 0.01m 이상 이격 시는 간섭영향이 없었다. 따라서 소출력인 UWB 시스템의 전파가 방송통신서비스에 간섭 영향 없이 시스템에 적용하기 위해서는 Impulse 방식의 UWB 시스템보다 OFDM 방식의 UWB 시스템이 간섭 영향이 적다는 것을 확인하였다.

  • PDF

표적모의장치를 이용한 SAR 장비의 성능 분석 (Performance Analysis of SAR System Using Radar Target Simulation Equipment)

  • 권순구;여환용;박성민;한지훈;정창식;김기완;신현익
    • 한국전자파학회논문지
    • /
    • 제29권2호
    • /
    • pp.118-127
    • /
    • 2018
  • 본 논문에서는 합성개구레이다(Synthetic Aperture Radar: SAR) 장비의 성능 분석을 위하여 레이다 표적모의장치를 설계, 제작한 결과를 선보인다. 먼저 표적모의장치의 기능과 성능에 대해 설명하고, SAR 장비와 연동하기 위한 표적 시나리오 생성방법에 대해 설명하였다. 또한 제작된 표적모의장치를 이용하여 SAR 장비의 시간지연 값을 간단하고 정확하게 측정하고 보상하는 방법을 개발하였다. 시간지연이 보상된 SAR 장비와 표적모의장치를 이용하여 SAR 영상에서 점표적을 획득하고, IRF(Impulse Response Function) 분석을 통해 성능을 분석하였다. 그 결과, 방위방향 IRF의 PSLR(Peak to Side Lobe Ratio)은 -13.25 dB, 해상도는 0.49 m로 이론값과 매우 유사한 값을 보였다.

Elastic modulus in large concrete structures by a sequential hypothesis testing procedure applied to impulse method data

  • Antonaci, Paola;Bocca, Pietro G.;Sellone, Fabrizio
    • Structural Engineering and Mechanics
    • /
    • 제26권5호
    • /
    • pp.499-516
    • /
    • 2007
  • An experimental method denoted as Impulse Method is proposed as a cost-effective non-destructive technique for the on-site evaluation of concrete elastic modulus in existing structures: on the basis of Hertz's quasi-static theory of elastic impact and with the aid of a simple portable testing equipment, it makes it possible to collect series of local measurements of the elastic modulus in an easy way and in a very short time. A Hypothesis Testing procedure is developed in order to provide a statistical tool for processing the data collected by means of the Impulse Method and assessing the possible occurrence of significant variations in the elastic modulus without exceeding some prescribed error probabilities. It is based on a particular formulation of the renowned sequential probability ratio test and reveals to be optimal with respect to the error probabilities and the required number of observations, thus further improving the time-effectiveness of the Impulse Method. The results of an experimental investigation on different types of plain concrete prove the validity of the Impulse Method in estimating the unknown value of the elastic modulus and attest the effectiveness of the proposed Hypothesis Testing procedure in identifying significant variations in the elastic modulus.