• Title/Summary/Keyword: Impulse Wave

Search Result 239, Processing Time 0.024 seconds

A Semi-Analytic Approach for Analysis of Parametric Roll (준해석적 방법을 통한 파라메트릭 횡동요 해석)

  • Lee, Jae-Hoon;Kim, Yonghwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.3
    • /
    • pp.187-197
    • /
    • 2015
  • This study aims the development of a semi-analytic method for the parametric roll of large containerships advancing in longitudinal waves. A 1.5 Degree-of-Freedom(DOF) model is proposed to account the change of transverse stability induced by wave elevations and vertical motions (heave and pitch). By approximating the nonlinearity of restoring moment at large heel angles, the magnitude of roll amplitude is predicted as well as susceptibility check for parametric roll occurrence. In order to increase the accuracy of the prediction, the relationship between righting arm(GZ) and metacentric height(GM) is examined in the presence of incident waves, and then a new formula is proposed. Based on the linear approximation of the mean and first harmonic component of GM, the equation of parametric roll in irregular wave excitations is introduced, and the computational results of the proposed model are validated by comparing those of weakly nonlinear simulation based on an impulse-response-function method combined with strip theory. The present semi-analytic doesn’ t require heavy computational effort, so that it is very efficient particularly when numerous sea conditions for the analysis of parametric roll should be considered.

Thickness Measurement by Using Cepstrum Ultrasonic Signal Processing (켑스트럼 초음파 신호 처리를 이용한 두께 측정)

  • Choi, Young-Chul;Park, Jong-Sun;Yoon, Chan-Hoon;Choi, Heui-Joo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.4
    • /
    • pp.290-298
    • /
    • 2014
  • Ultrasonic thickness measurement is a non-destructive method to measure the local thickness of a solid element, based on the time taken for an ultrasound wave to return to the surface. When an element is very thin, it is difficult to measure thickness with the conventional ultrasonic thickness method. This is because the method measures the time delay by using the peak of a pulse, and the pulses overlap. To solve this problem, we propose a method for measuring thickness by using the power cepstrum and the minimum variance cepstrum. Because the cepstrums processing can divides the ultrasound into an impulse train and transfer function, where the period of the impulse train is the traversal time, the thickness can be measured exactly. To verify the proposed method, we performed experiments with steel and, acrylic plates of variable thickness. The conventional method is not able to estimate the thickness, because of the overlapping pulses. However, the cepstrum ultrasonic signal processing that divides a pulse into an impulse and a transfer function can measure the thickness exactly.

The Effect of Carbon Monoxide Inhalation on the Uterine Motility of the Nonpregnant Rabbit (일산화탄소흡입(一酸化炭素吸入)이 비임신(非妊娠) 토끼자궁운동(子宮運動)에 미치는 영향(影響))

  • Shin, Dong-Hoon;Kim, Ki-Kon
    • The Korean Journal of Physiology
    • /
    • v.9 no.2
    • /
    • pp.17-22
    • /
    • 1975
  • Adult nonpregnant female rabbits were subjected to the study of the effects of carbon monoxide inhalation on the uterine motility. Animals were anesthetized with intravenous injection of nembutal, 35 mg/kg, and the uteri were exposed. Polyethylene tubing which had a small hole near the blind tip was inserted in the loop and normal saline was infused at a constant rate of 1.5 ml/min. On the other end of the loop, an outlet of fluid was made. When a peristaltic wave proceeded to the hole, a rise of the pressure was ensued and it was transmitted to the pressure transducer, making an upward deflection of the recording pen on the physiograph. Carbon monoxide, 1,000 ppm in the concentration, was inhaled through a tracheal cannula for 30 minutes, following fresh air for 30 minutes. In some cases, pure oxygen was also supplemented for another 30 minutes. Uterine motility was expressed in terms of the impulse that was the time integral of the pressure and of the frequency of the peristaltic waves. The results obtained were as follows. 1. When 1,000 ppm carbon monoxide was inhaled for 30 minutes, the impulse dropped to $72{\pm}16.5%$ and the frequency to $75{\pm}22.7%$ of the values obtained before the gas administration. 2. By fresh air for 30 minutes, the impulse and the frequency restored to $77{\pm}25.7%$ and $92{\pm}21.1%$, respectively. 3. By the supplement of pure oxygen for 30 minutes, no remarkable improvement were revealed, showing $89{\pm}35.2%$ in the impulse and $91{\pm}10.8%$ in the frequency, respectively. 4. There was an appreciable discrepancy in the recovery courses of the impulse and the frequency, suggesting different mechanisms attributable to the alteration by carbon monoxide inhalation.

  • PDF

Pspice Simulation for Nonlinear Components and Surge Suppression Circuits (비선형 소자 및 서지억제회로의 Pspice 시뮬레이션)

  • Lee, Bok-Hui;Gong, Yeong-Eun;Choe, Won-Gyu;Jeon, Deok-Gyu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.8
    • /
    • pp.477-486
    • /
    • 2000
  • This paper presents Pspice modeling methods for spark gaps and ZnO varistors and describes the application for the two-stage surge suppression circuit which was composed of the nonlinear components. The simulation modelings of nonlinear components were conducted on the basis of the voltage and current curves measured by the impulse current with the time-to-crest of $1~50 \mus$ and the impulse voltage with the rate of the time-to-crest of 10, 100 and 1000 V/\mus$. The firing voltages of the spark gap increased with increasing the rate of the time-to-crest of impulse voltage and the measured data were in good agreement with the simulated data. The I-V curves of the ZnO varistor were measured by applying the impulse currents of which time-to-crests range from 1 to $50 \mus$ and peak amplitudes from 10 A to 2 kA. The simulation modeling was based on the I-V curves replotted by taking away the inductive effects of the test circuit and leads. The meximum difference between the measured and calculated data was of the order of 3%. Also the two-stage surge suppression circuit made of the spark gap and the ZnO varistor was investigated with the impulse voltage of $10/1000\mus$$mutextrm{s}$ wave shape. The overall agreement between the theoretical and experimental results seems to be acceptable. As a consequence, it was known that the proposed simulation techniques could effectively be used to design the surge suppression circuits combined with nonlinear components.

  • PDF

A Study on Integrated OWC System within Turbine Effects

  • Liu, Zhen;Hyun, Beom-Soo;Hong, Key-Yong;Lee, Young-Yeon;Jin, Ji-Yuan
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.2
    • /
    • pp.1-9
    • /
    • 2010
  • Oscillating Water Column is one of the most widely used converting systems all over the world. The operating performance is influenced by the efficiencies of the two converting stages in the OWC chamber-turbine integrated system. In order to study the effects of the pressure drop induced by the air turbine, the experiments using the impulse turbine and the orifice device are carried out in the wave simulator test rig. The numerical simulation utilizing the orifice and porous media modules is calculated and validated by the corresponding experimental data. The numerical wave tank based on the two-phase VOF model embedded with the above modules is employed to investigate the wave elevation, pressure variation inside the chamber and the air flow velocity in the duct. The effects of the air turbine on the integrated system and interaction among the wave elevation, pressure and air flow velocities variations are investigated, which demonstrates that the present numerical model are more accurate to be employed.

Study of the Weak Shock Wave Propagating inside an Engine Exhaust Muffler (엔진 배기 소음기내를 전파하는 약한 충격파에 관한 연구)

  • 이동훈;권용훈;김희동
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.7
    • /
    • pp.510-519
    • /
    • 2002
  • The present study addresses a computational work of the weak shock wave propagating inside an automobile exhaust muffler. Several different types of the silencer systems are employed to investigate the magnitude of the shock wave during propagating through them. The Initial shock wave Mach number $M_s$ is varied between 1.01 and 1.30, and a normal shock wave is given at the inlet of the silencer systems. The second order total variation diminishing scheme Is employed to solve the two dimensional, compressible, unsteady Euler equations. The present computational results are compared with the previous experimental ones available. The present computations predict the experimental results with a quite good accuracy. Of the four silencer systems applied. the most desirable silencer system to reduce the peak pressure at the exalt of the exhaust pipe is discussed from the Point of view of the engineering design of the silencer systems.

Vibration characteristics of caisson breakwater for various waves, sea levels, and foundations

  • Lee, So-Young;Huynh, Thanh-Canh;Dang, Ngoc-Loi;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • v.24 no.4
    • /
    • pp.525-539
    • /
    • 2019
  • In this study, vibration characteristics of a gravity-based caisson-foundation breakwater system are investigated for ambient and geometric parameters such as various waves, sea levels, and foundation conditions. To achieve the objective, following approaches are implemented. Firstly, operational modal analysis methods are selected to identify vibration modes from output-only dynamic responses. Secondly, a finite element model of an existing caisson-foundation breakwater system is established by using a structural analysis program, ANSYS. Thirdly, forced vibration analyses are performed on the caisson-foundation system for two types of external forces such as controlled impacts and wave-induced dynamic pressures. For the ideal impact, the wave force is converted to a triangular impulse function. For the wave flow, the wave pressure acting on the system is obtained from wave field analysis. Fourthly, vibration modes of the caisson-foundation system are identified from the forced vibration responses by combined use of the operational modal analysis methods. Finally, vibration characteristics of the caisson-foundation system are investigated under various waves, sea levels, and foundations. Relative effects of foundation conditions on vibration characteristics are distinguished from that induced by waves and sea levels.

The numerical analysis of heavy-weight impact noise for an apartment houses considering acoustic mode (Acoustic mode 를 고려한 공동주택 중량충격음 소음해석)

  • Mun, Dae-Ho;Hwang, Jae-Seung;Park, Hong-Gun;Hong, Geon-Ho;Im, Ju-Hyeuk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.394-402
    • /
    • 2009
  • To investigate the heavy-weight impact noise of apartment houses, numerical analysis was performed. The analysis acoustic pressure consider acoustic mode by finite element method. The variables considered effecting on the acoustic pressure are the Acoustic mode, acoustic damping, and the impulse load. The heavy-weight impact noise is a changeable value in the room. Since the most part of the frequency component of heavy-weight impact noise has low frequency. The noise in low frequency is related to the vibration of structure, the reflection of acoustic wave caused by wall and the standing wave called by acoustic mode. The prediction by the numerical analysis was verified with test result of the heavy weight-impact noise at apartment houses.

  • PDF

Development of an Impulse Electromagnetic Wave Generator having Rise time of Pico Second (Pico second 기립시간의 충격 전자기파 발생기의 개발)

  • Kim, Young-Bae;Lee, Hong-Sik;Jung, Sun-Shin
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.12
    • /
    • pp.597-600
    • /
    • 2006
  • When the energy of the nanoseconds high voltage pulse with hundreds picoseconds of the pulse rise time is emitted into the free space via an antenna, an ultra wide band electromagnetic wave is generated. This electromagnetic wave is expected to be used in transmitting vast amount of informations to far distance, high performance radars, post-packaging pasteurization of food, the detection of underground buried objects, searching of underground water veins or caves, the treatment of waste water or polluted gases and so forth. Additionally, this technology can be used in EMI(electromagnetic interference) evaluation of measuring instruments or printed circuit boards.

A Study on the Evaluatioin Methods for the Rear Safety Zone of Portable Guided Missile (휴대용 유도탄의 후방 안전영역 평가방법에 관한 연구)

  • Song, Kee-Hyeok;Kang, Woo-Ram;Park, Jong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.2
    • /
    • pp.63-69
    • /
    • 2015
  • Recoilless weapons, which lead strong back blast and impulse noise more than 160 dB, have been used in compliance with the regulation of the safety zone for the safe operations. However, the safety zone regulations for the newly developed weapons should be prepared since the existing guidelines do not provide any information concerning the reason for the safety zone. In this study, the outdoor launch tests were performed to collect the data such as noise, pressure and temperature of the back blast. An assessment method using data obtained from launch tests has been proposed to determine the safety zone. The safety zone has been determined with consideration for the following criteria: Impulse noise, temperature and pressure of the back blast and blast angle. As a results, new safety zones for them have been established for the recoilless weapon developed by ADD (Agency for Defense Development). We expect that this research can be used as a guideline for establishing a new safety zone regulation of similar weapon to be developed.