• Title/Summary/Keyword: Impulse Response Analysis

Search Result 330, Processing Time 0.031 seconds

Analysis of Runoff Characteristics Using Multiple Impulse Response Functions (복수의 충격응답함수를 이용한 유역의 유출특성 분석)

  • Yoo, Chul-Sang;Kim, Ha-Young;Park, Joo-Young
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.6
    • /
    • pp.571-581
    • /
    • 2010
  • This study analyzed rainfall-runoff characteristics by deriving multiple impulse responses. The concept of competing impulse responses was used for deriving multiple impulse responses. Based on this concept, each response function derived competes to be selected for simulating the runoff measured. This concept of competing linear impulse responses was applied to four basins, Jeongseon, Yeongwol, Youngchoon and Chungju Dam. One to three impulse responses have been derived and compared each other considering basin characteristics. First, in case of deriving one linear impulse response, the peak flow of the impulse response was found to be increased according to their study basins area. In case of deriving two linear impulse response, the peak flow of the first impulse response and the duration of the second impulse response were increased according to their basin size. The case of deriving three impulse response showed similar characteristics of deriving two impulse responses. However, the peak flow of third impulse response was very small and lasted quite long time. Summarizing these results considering the basin characteristics, the first impulse response seems to be related with the surface runoff, the second impulse with the surface runoff and interflow, and the third impulse response with the interflow and base flow.

A Study of Response Characteristics for the Interior Impulse Noise based on Interpreted Models (해석 모델 기반의 실내 충격소음 응답특성에 관한 연구)

  • Song, Kee-Hyeok;Chung, Sung-Hak
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.22-28
    • /
    • 2014
  • This study is compare to model-based analysis and experimental data of the response characteristic of interior impulse noise. Interior impulse noise and the pressure response characteristics of the building structure on its analysis are presented the impulse pressure acting on the rear wall 90 N-sec. The force acting on the wall $CFD^{{+}{+}}$ which are compared measurement and simulation analysis. Results of simulation and measurement data were shown. In this study, a high dimension of the degree of virtual space in the numerical space of the lesser degree in order to calculate folding method was applied. The results of this study contribute safety evaluation and model development for the interior impulse noise that affects the basic data for the interior impulse noise model validate for the physical quantity prediction.

Investigation of Influences of UWB Antennas on Impulse Radio Channel (임펄스 전파 채널에서의 초광대역 안테나 영향 연구)

  • Park Young-Jin;Song Jong-Hwa;Kim Kwan-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.12
    • /
    • pp.165-170
    • /
    • 2005
  • In this paper, influences of a ultra wideband (UWB) antenna on impulse channel measurement are investigated in time domain (TD) and frequency domain (FD) as well. Firstly, impulse response of an UWB antenna is obtained and then using the result of impulse response of the UWB antenna, influences of the antenna on impulse radio channel is analyzed. Furthermore, using the impulse response of the UWB anenna, method of impulse radio channel analysis is presented by excluding the effect of the antenna from an impulse radio channel. For verifying the theory, a modified conical monopole antenna is designed for measuring impulse radio channel and its impulse response is obtained. After that, in order to investigate the effects of the UWB antenna on an impulse radio channel, multipath environments are set up in an anechonic chamber and transmission coefficient for each multipath environment is measured with an aid of vector network analyzer. Data measured in frequency domain is transformed into those in time domain by way of signal processing. Measurement shows that such properties of the antenna as dispersion and ringing affect impulse radio channel. Moreover, using the impulse response of the antenna, impulse response of only multipath channel is obtained.

The Response to Impulse Signal on Three Phase Transformer using Vector Network Analyzer (벡터 회로망 분석기 측정을 기반으로 한 3상 변압기의 시간영역 펄스 신호에 대한 응답 분석)

  • Kim, Kwangho;Jung, Jongman;Nah, Wansoo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.79-84
    • /
    • 2015
  • Transformer is widely used element on power system and industrial area. Especially the transformers installed at power system are exposed to an environment of arbitrary changed. Thus the prediction of degradation and the analysis of response to impulse are important. To conduct those works, the electrical characteristics of system should be analyzed, effectively. But the analysis of electrical characteristic in electric machine level such as pole and pad-mounted transformer is almost no, thus commercial VNA (Vector Network Analyzer) is used to getting the response in wide frequency range. However, the output power of VNA is usually under 10mW, so verification for effectiveness of measuring electrically large component should be conducted, firstly. Next, after getting total S-parameter of transformer, predicting impulse response can be performed in time-domain with circuit simulator. In this paper, it is introduced that verification effectiveness of VNA using transfer function from SFRA (Sweep Frequency Response Analyzer), firstly. Next, total S-parameter, six by six matix form, was built using measured 2 port S-parameter from vector network analyzer. To get the response to impulse which is defined by IEC 60060-1, time-domain simulation is conducted to ADS (Advenced Design System) circuit simulator.

A study on nonlinear seismic response analysis of building considering frequency dependent soil impedance in time domain

  • Nakamura, Naohiro
    • Interaction and multiscale mechanics
    • /
    • v.2 no.1
    • /
    • pp.91-107
    • /
    • 2009
  • In order to accurately estimate the seismic behavior of buildings, it is important to consider both nonlinear characteristics of the buildings and the frequency dependency of the soil impedance. Therefore, transform methods of the soil impedance in the frequency domain to the impulse response in the time domain are needed because the nonlinear analysis can not be carried out in the frequency domain. The author has proposed practical transform methods. In this paper, seismic response analyses considering frequency dependent soil impedance in the time domain are shown. First, the formulation of the proposed transform methods is described. Then, the linear and nonlinear earthquake response analyses of a building on 2-layered soil were carried out using the transformed impulse responses. Through these analyses, the validity and efficiency of the methods were confirmed.

Leak Detection of Circular Piping Systems by Using Unit Impulse Response Function Analysis (단위 충격 응답함수를 이용한 원형관 시스템의 주출감지 연구)

  • 전오성;윤병옥;김창호
    • Journal of KSNVE
    • /
    • v.4 no.3
    • /
    • pp.337-343
    • /
    • 1994
  • A method of the leak detection from the pipe system by using accelerometer is proposed. The signal detected from accelerometer is proved experimentally to be a dispersive wave. Based on the experiments, a method using the narrow band pass filter and the unit impulse response function is analyzed. The method uses the characteristics of the unit impulse response function, that the function is available evenin the narrow band signal because, unlike the cross correlation, it is normalized by the auto spectrum. The accelerometer is quite easier to use than the hydrophone in adapting to the pipe system.

  • PDF

Analysis of the Transient Dynamic Response of Ocean Mining Pipe System Due to Impulse (임펄스 가진에 의한 근해역 통합채광시험 양광시스템의 파이프 동적 과도응답 해석)

  • Cho, Kyu-Nam;Kim, Min;Park, Yong-Chan;Yoon, Chi-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.2
    • /
    • pp.105-111
    • /
    • 2007
  • A finite element analysis scheme is proposed to assess the dynamic response due to impulse excitation of ocean mining pipe system. Transient dynamic response analysis based on the proposed scheme was carried out for various types of impulses, and the magnitude of cable tension induced by impulse was discussed by using a model of 'Segero', a special purpose ship of KT-Submarine as well as ROV carrier 'Onnuri' A qualitative, prospective guideline for the relevant marine operation is obtained.

Assessment of Dynamic Behavior of Cable System Due to Launching and Recovery of UUV (무인잠수정의 진수 인양에 따른 케이블시스템의 동적거동 평가)

  • Cho Kyu Nam;Kim Min;Song Ha Cheal
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.193-197
    • /
    • 2004
  • A finite element analysis is proposed to assess the dynamic response due to impulse excitation of UUV cable system. 'Onnuri'. a special purpose ship of KORDI. was adopted as a support vessel. and all the main dimensions and properties used in the analysis were determined by the support vessel. Transient dynamic response analysis was carried out for various types of impulses. and the magnitude of cable tension induced by impulse was discussed as results.

  • PDF

A Study On The Characteristics Of The Medium Voltage Power Distribution Line Channel By Wideband Channel Impulse Response Measurement Using PN Sequence (PN 시퀀스 방식의 광대역 임펄스 응답 측정을 통한 고압 배전선로 채널 특성 연구)

  • Oh Hui-Myoung;Choi Sung-Soo;Lee Jae-Jo;Kim Kwan-Ho;Whang Keum-Chan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.1
    • /
    • pp.56-60
    • /
    • 2005
  • In the power-line communication(PLC) systems, the power line is a wired medium. However, the power line channel has the multi-path fading characteristics like the wireless channel in the wireless communication systems because it has the signal reflection and divergence by the impedance mismatching between many branch lines and loads. So the analysis of the multi-path characteristics is very important, and it has been doing by the several measurement methods for the impulse response between the transmitter and the receiver. PN sequence method has originally been used as a wideband impulse response measurement mettled for wireless channel, but it is recently being applied to not only the wireless channel but also the wired channel like the power line channel. This method is more useful and effective for the long distance communication channel like the medium voltage power distribution line with the multi-paths[1]. In this thesis, we have measured impulse response for the medium voltage power distribution line channel by the wideband measurement method using PN sequence, analytically studied the measured data and presented the results.

Hydrodynamic Modeling for Discharge Analysis in a Dielectric Medium with the Finite Element Method under Lightning Impulse

  • Lee, Ho-Young;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.397-401
    • /
    • 2011
  • The response of lightning impulse voltage was explored in dielectric liquids employing hydrodynamic modeling with three charge carriers using the finite element method. To understand the physical behavior of discharge phenomena in dielectric liquids, the response of step voltage has been extensively studied recently using numerical techniques. That of lightning impulse voltage, however, has rarely been investigated in technical literature. Therefore, in this paper, we tested impulse response with a tip-sphere electrode which is explained in IEC standard #60897 in detail. Electric field-dependent molecular ionization is a common term for the breakdown process, so two ionization factors were tested and compared for selecting a suitable coefficient with the lightning impulse voltage. To stabilize our numerical setup, the artificial diffusion technique was adopted, and finer mesh segmentation was generated along with the axial axis. We found that the velocity from the numerical result agrees with that from the experimental result on lightning impulse breakdown testing in the literature.