• 제목/요약/키워드: Impulse Response

검색결과 971건 처리시간 0.035초

A Study on Indicial Response Characteristics of a Gas-Lubricated Spiral-Grooved proceeding Bearing

  • Yabe, H.;Kaneshiro, T.;Hirayama, T.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.101-102
    • /
    • 2002
  • Indicial response characteristics of a rotor supported by a gas-lubricated, spiral-grooved proceeding bearing are studied theoretically to develop a fundamental investigation for the bearing design with considering NRRO characteristics. The trajectory of rotor movement is calculated by applying the non-linear orbit scheme against a prescribed impulse load, then two characteristic quantities are introduced to evaluate the indicial response performance of the bearing, i.e., 'maximum deviation of rotor center' and 'integrated rotor center deviation'. The effects of some design parameters of spiral grooves to these representative quantities are studied so that 'robust' design against impulse load is discussed.

  • PDF

SIMPLE AND EFFECTIVE METHOD TO PREDICT THE OCCUPANT DYNAMIC RESPONSE UNDER SUDDEN IMPULSE LOADS

  • Elmarakbi, A.M.
    • International Journal of Automotive Technology
    • /
    • 제7권7호
    • /
    • pp.769-776
    • /
    • 2006
  • A mathematical model is developed in this paper to define the interaction between the occupant and vehicle passenger compartment and to predict the occupant dynamic response during a sudden impulse load. Two different types of occupants are considered in this study, child and adult occupants. The occupants are considered as lumped masses connected to the child seat and vehicle's body masses by means of restraint systems. In addition, the occupant restraint characteristics of seat belt and airbag are represented by stiffness and damping elements. To obtain the dynamic response of the occupant, the equations of motion of the occupants during vehicle collisions are developed and analytically solved. The occupant's acceleration and relative displacement are used as injury criteria to interpret the results. It is demonstrated from the numerical simulations that the dynamic response and injury criteria are easily captured and analyzed. It is also shown that the mathematical models are flexible, useful in optimization studies and it can be used at initial design stage.

광대역 초음파 장 응답의 해석과 집속된 Annular Array 영상 시스템 설계에의 응용 (Analysis of Broadband Ultrasonic Field Response and its Application to the Design of Focused Annular Array System)

  • 노경태;송태경;박송배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.1252-1255
    • /
    • 1987
  • In this paper an approach for the analysis of the transient field response of radially symmetric transducer due to a wideband ultrasonic pulse is presented, which is based on a development of Green's function and applies the linear system theory to obtain an analytic expression for the impulse response of an annulus with a planar or spherical geometry. For the focused annular array, the impulse responses of the indivisual annuli are convolved with the delayed excitation pulse, and then summed to obtain the resultant response of the array. This process is very effective in the study of the various focusing abilities of the annular array. For illustration, the field distribution of a five element annular array is treated in detail for several focusing system.

  • PDF

링보강 복합재료 원통셸의 과도응답 (Transient Response of Composite Cylindrical Shells with Ring Stiffeners)

  • 김영완;정강;박경조
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.883-888
    • /
    • 2001
  • The theoretical method is developed to investigate the effects of ring stiffeners on free vibration characteristics and transient response for the ring stiffened composite cylindrical shells subjected to the impulse pressure loading. In the theoretical procedure, the Love's thin shell theory combined with the discrete stiffener theory to consider the ring stiffening effect is adopted to formulate the theoretical model. The concentric or eccentric ring stiffeners are laminated with composite and have the uniform rectangular cross section. The modal analysis technique is used to develop the analytical solutions of the transient problem. The analysis is based on an expansion of the loads, displacements in the double Fourier series that satisfy the boundary conditions. The effect of stiffener's eccentricity, number, size, and position on transient response of the shells is examined. The theoretical results are verified by comparison with FEM results.

  • PDF

충격전류 측정용 shunt의 직각파 응답특성에 관한 연구 (A Study on the Step Reaponse Characteristics in Shunt for Switching Impulse current)

  • 김익수;정주영;최재구;문인욱;이덕진;신영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2132-2134
    • /
    • 2000
  • Since surge arresters are recommended to protect the electric power system from the lighting surge, the impulse current is generally used to verify this requirement at the test labotaries. Recently, the international standard(IEC 60060-2) related to the impulse current techniques revised requiring a traceability of measuring system for impulse current measurements. In this paper, a shunt for impulse current is developed satisfing the revised IEC standard and the possibility of application has been investigated using step response.

  • PDF

개폐 충격전압 측정용 쉴드 저항분압기의 직각파 특성에 관한 연구 (A Study on the Step Response Characteristics in Shielded Resistor Divider for Switching Impulse Voltage)

  • 김익수;이형호;조정수;박정후
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권12호
    • /
    • pp.777-784
    • /
    • 1999
  • Since the ultra-high voltage power apparatus are recommended to withstand switching surge generated from the electric power system, the switching impulse voltage is generally used to verify this requirement at the testing laboratories. Recently, the international standard(IEC 60060-2) related to the high voltage measurement techniques is revised requiring a traceability of measuring system for high voltage measurements. In this paper, a reference divider for switching impulse voltage is developed satisfying the revised. IEC standard and the possibility of applications has been investigated. Therefore, the characteristics of the high and low voltage side resistor and the shielding ring have been analyzed including the step response characteristics of the prototype divider. Throughout various efforts, it is confirmed that our measuring device has shown compatible characteristics as a reference divider.

  • PDF

수변전설비에서 접지시스템의 공결점의 위치에 따른 임펄스 응답특성 (Impulse Response Characteristics of the Grounding Systems with respect to the Common-Connection Position in Power Utility System)

  • 이복희;엄주홍;김성원;심판섭;이승칠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2149-2151
    • /
    • 1999
  • This paper describes the impulse response characteristics of the grounding systems in power utility system. Several regulations regarding to electric power equipments, services and managements require that the groundings of class 1 ($E_1$) and class 2 ($E_2$) must be connected at the common point in grounding systems. In addition, the grounding for arrester ($E_{LA}$), which belongs to the grounding of class 1, should be connected at the same point. However, there is no method and position of common-connection at anywhere. In this work, when the impulse current was injected through the grounding conductor for arrester, the investigations measuring and analyzing potential rises induced at the common connection point and other grounding conductors were conducted. The experiments were carried out in the conditions of the grounding conductor of 25m long and the near or remote common connection from ground electrode. The lightning impulse current was applied so as to simulate the on-set of arrester due to lightning and/or switching surges.

  • PDF

Study on the Transfer Functions for Detecting Windings Displacement of Power Transformers with Impulse Method

  • Shon, Chae-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.876-883
    • /
    • 2012
  • The paper investigates three types of transfer function methods for detecting displacements of winding in a model transformer. To acquire these transfer functions, the measuring method of input voltage, current and its response is used in impulse method. The applied impulse voltages had three rising times, which were short rising time (less than 0.6 ${\mu}s$), medium rising time (about 0.8 ${\mu}s$) and long rising time (about 1 ${\mu}s$) in front waves. Every 10 measurements of voltage and current waves were averaged from 50 measurements of voltage and current waves. These transfer functions were tested in normal, 24mm elevated and 48mm elevated windings conditions and were analyzed with correlation coefficients and spectrum deviations. In the analysis, the results depend on the types of transfer functions and the rising times of input voltages.

지수창함수를 사용한 임팩트햄머 실험에서 주파수응답함수의 왜곡과 개선책 (FRF Distortion Caused by Exponential Window Function on Impact Hammer Testing and Its Solution)

  • 안세진;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제13권5호
    • /
    • pp.334-340
    • /
    • 2003
  • Exponential window function Is widely used In impact hammer testing to reduce leakage error as well as to get a good S/N ratio. The larger its decaying rate is, the more effectively the leakage errors are reduced. But if the decay rate of the exponential window is too large, the FRF is distorted. And the modal parameters of the system can not be exactly identified by modal analysis technique. Therefore, it is a difficult problem to determine proper decay rate in impact hammer testing. In this paper, amount of the FRF distortion caused by exponential window is theoretically uncovered. A new circle fitting method is also proposed so that the modal parameters are directly extracted from impulse response spectrum distorted by the exponential-windowed impulse response data. The results by the conventional and proposed circle fitting method are compared through a numerical example.

전력설비용 접지시스템에 공결점에 따른 과도응답특성 (Transient Response characteristics Associated with the Common Connection Points in Grounding Systems for Electric Power Utilitires)

  • 이복희;이승칠;엄주홍;심판섭
    • 조명전기설비학회논문지
    • /
    • 제13권3호
    • /
    • pp.101-108
    • /
    • 1999
  • 본 논문은 임펄스전류에 대한 전력설비용 접지시스템의 과도응답특성에 대하여 기술하엿으며, 피뢰기 접지도선을 통하여 임펄스전류가 유입될 때, 공결점과 다른 접지도선에 유도되는 전위상승을 측정·분석하였다. 낙뢰서지에 의한 피뢰기의 동작을 모의하기 위하여 뇌임펄스전류를 인가하였으며, 본 실험에서 얻은 임펄스 응답특성의 실험결과는 다음과 같다. 접지전극에 유도되는 전위상승은 접지도선에 유도된 것과는 상당히 달았으며, 다른 독립접지전극에도 높은 전위유도가 발생하였다. 또한 임펄스전류에 의한 접지전극과 접지도선의 전위상승은 공결점의 위치에 따라 현저하게 변하였다. 근방공결한 경우 임펄스전류에 의한 공결점의 전위상승은 원방공결한 경우보다 낮게 나타났다. 피뢰기 접지도선의 전위상승은 근방공결한 경우가 원방공결항 것보다 높게 나타났다. 따라서 전위상승의 측면을 고려하면 근방공결하는 경우가 원방공결하는 것보다 효과적이고, 전력기기의 절연보호 측면에서는 원방공결하는 것이 보다 효과적임을 알았다.

  • PDF