• Title/Summary/Keyword: Improvement of water quality

Search Result 1,149, Processing Time 0.026 seconds

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Development of a Dose Calibration Program for Various Dosimetry Protocols in High Energy Photon Beams (고 에너지 광자선의 표준측정법에 대한 선량 교정 프로그램 개발)

  • Shin Dong Oh;Park Sung Yong;Ji Young Hoon;Lee Chang Geon;Suh Tae Suk;Kwon Soo IL;Ahn Hee Kyung;Kang Jin Oh;Hong Seong Eon
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.381-390
    • /
    • 2002
  • Purpose : To develop a dose calibration program for the IAEA TRS-277 and AAPM TG-21, based on the air kerma calibration factor (or the cavity-gas calibration factor), as well as for the IAEA TRS-398 and the AAPM TG-51, based on the absorbed dose to water calibration factor, so as to avoid the unwanted error associated with these calculation procedures. Materials and Methods : Currently, the most widely used dosimetry Protocols of high energy photon beams are the air kerma calibration factor based on the IAEA TRS-277 and the AAPM TG-21. However, this has somewhat complex formalism and limitations for the improvement of the accuracy due to uncertainties of the physical quantities. Recently, the IAEA and the AAPM published the absorbed dose to water calibration factor based, on the IAEA TRS-398 and the AAPM TG-51. The formalism and physical parameters were strictly applied to these four dose calibration programs. The tables and graphs of physical data and the information for ion chambers were numericalized for their incorporation into a database. These programs were developed user to be friendly, with the Visual $C^{++}$ language for their ease of use in a Windows environment according to the recommendation of each protocols. Results : The dose calibration programs for the high energy photon beams, developed for the four protocols, allow the input of informations about a dosimetry system, the characteristics of the beam quality, the measurement conditions and dosimetry results, to enable the minimization of any inter-user variations and errors, during the calculation procedure. Also, it was possible to compare the absorbed dose to water data of the four different protocols at a single reference points. Conclusion : Since this program expressed information in numerical and data-based forms for the physical parameter tables, graphs and of the ion chambers, the error associated with the procedures and different user could be solved. It was possible to analyze and compare the major difference for each dosimetry protocol, since the program was designed to be user friendly and to accurately calculate the correction factors and absorbed dose. It is expected that accurate dose calculations in high energy photon beams can be made by the users for selecting and performing the appropriate dosimetry protocol.

Analysis and Improvement Measures on the Status of the Installation and Operation of Facilities for Recycling Food Waste into Compost (음식물쓰레기 퇴비화시설의 설치 및 운영 현황분석 및 개선방안)

  • Ryu, Ji-Young;Kong, Kyu-Sik;Shin, Dae-Yewn;Phae, Chae-Gun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.3
    • /
    • pp.95-111
    • /
    • 2004
  • This research sought to determine the status of the installation and operation of composting facilities of domestic public resource-making facilities and come up with corresponding improvement measures. The composting facilities were the most extensively installed of related facilities with over a 0.5 ton treated volume per day. The monthly and yearly carry-in volume of food waste were found to stand at 1,101.7 tons per day and 930.9 tons per day, thus falling short of the average planned volume of 1,270.9 tons. Many composting facilities, which were installed in areas for which factory registration were not approved, did not get approvals. Composting facilities underwent operation stoppage mainly due to faulty fermentation and crushing equipment. Mainly metals contained in food waste caused faults to the crushing equipment, thus requiring a facility designing against faults and corrosion. The initial water content was found to stand at 50-60%, thus complying with the requirement. However, since the composting food waste had an appropriate mixture of sawdust, food waste, and returned compost, it should meet the initial conditions. For fermentation facilities, the duration time for fermentation was 15 days, and post-fermentation tanks required 21 days of duration time, thus establishing the minimum criteria. However, some facilities did not meet the requirements, taking more time in decomposition, thus suggesting a need to determine the duration time according to facilities. In composting food waste, microorganism-based thermal oxidizer-operated fermentation tanks should be used to ensure an economic operation. On the contrary, 14 out of 25 survey targets heated fermentation tanks in any form. These thermal facilities contain the growth of bacteria, lowering chemical reaction in composting; thus composting facilities should be basically designed to use microorganism-based thermal oxidizers in drying water. An average daily volume of food waste and supplementary materials that was injected in producing compost was 22.8 tons. This volume produced 7.3 tons of compost per day, decreasing 68%. Properties of produced compost were analyzed by its color, absence or presence of remaining decomposition heat, and smell, to assess the quality. As a result, the composting process was not properly installed nor operated in about 50% of composting facilities. Compost should be produced to be soil-friendly.

  • PDF

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2004 and 2005 - (공기조화, 냉동 분야의 최근 연구 동향 -2004년 및 2005년 학회지 논문에 대한 종합적 고찰-)

  • Choi, Yong-Don;Kang, Yong-Tae;Kim, Nae-Hyun;Kim, Man-Hoe;Park, Kyoung-Kuhn;Park, Byung-Yoon;Park, Jin-Chul;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.94-131
    • /
    • 2007
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2004 and 2005 has been done. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD and flow visualization(PIV, PTV and LDV methods) technologies were widely applied for developing facilities and their systems. (2) The research trends of the previous two yews are surveyed as groups of natural convection, forced convection, electronic cooling, heat transfer enhancement, frosting and defrosting, thermal properties, etc. New research topics introduced include natural convection heat transfer enhancement using nanofluid, supercritical cooling performance or oil miscibility of $CO_2$, enthalpy heat exchanger for heat recovery, heat transfer enhancement in a plate heat exchanger using fluid resonance. (3) The literature for the last two years($2004{\sim}2005$) is reviewed in the areas of heat pump, ice and water storage, cycle analysis and reused energy including geothermal, solar and unused energy). The research on cycle analysis and experiments for $CO_2$ was extensively carried out to replace the Ozone depleting and global warming refrigerants such as HFC and HCFC refrigerants. From the year of 2005, the Gas Engine Heat Pump(GHP) has been paid attention from the viewpoint of the gas cooling application. The heat pipe was focused on the performance improvement by the parametric analysis and the heat recovery applications. The storage systems were studied on the performance enhancement of the storage tank and cost analysis for heating and cooling applications. In the area of unused energy, the hybrid systems were extensively introduced and the life cycle cost analysis(LCCA) for the unused energy systems was also intensively carried out. (4) Recent studies of various refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and of alternative refrigerants including carbon dioxide. Efficiency of various compressors and expansion devices are also dealt with for better modeling and, in particular, performance improvement. Thermoelectric module and cooling systems are analyzed theoretically and experimentally. (5) According to the review of recent studies on ventilation systems, an appropriate ventilation systems including machenical and natural are required to satisfied the level of IAQ. Also, an recent studies on air-conditioning and absorption refrigeration systems, it has mainly focused on distribution and dehumidification of indoor air to improve the performance were carried out. (6) Based on a review of recent studies on indoor environment and building service systems, it is noticed that research issues have mainly focused on optimal thermal comfort, improvement of indoor air Quality and many innovative systems such as air-barrier type perimeter-less system with UFAC, radiant floor heating and cooling system and etc. New approaches are highlighted for improving indoor environmental condition as well as minimizing energy consumption, various activities of building control and operation strategy and energy performance analysis for economic evaluation.

A Study on the Pavement Status and Improvement Directions of the Viewing Road in Royal Tombs of Joseon Dynasty (조선 왕릉 관람로의 포장현황과 개선방향)

  • Paek, Chong-Chul;Hong, Youn-Soon
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.37 no.2
    • /
    • pp.66-73
    • /
    • 2019
  • The Royal Tomb of the Joseon Dynasty, which was listed as a UNESCO World Heritage site in 2009, is a cultural resource recognized for its 'outstanding universal value' around the world. The royal tomb of Joseon has been managed with an emphasis on the preservation of cultural assets since it was designated as a historical site in the 1970s, but it has received many visitors as a valuable historical and cultural resource and haven that connects the past and the present in today's bustling city. In order to investigate and analyze the current status of pavements in the royal palace in terms of quality and quantity, and to suggest the direction of improvement, this study conducted a complete survey of 53 royal palace viewing roads in 18 regions, and the results are as follows. First of all, problems are found in both the early Masato pavement of the creation, which was introduced with an emphasis on the preservation and protection of cultural assets, and the hardening pavement(KAP), which began to be used in the 1990s for the convenience of maintenance. In other words, the Masato pavement used to create a more environmentally friendly atmosphere of the Joseon royal tombs is showing a high percentage of use, but it lacks support for walking activities, such as the slippage of the pavement and water pooling during the rainy season or during the ice season. Also, hardening pavement introduced for convenience of maintenance, such as the movement of repair vehicles, is not functioning properly as it is damaged by physical deformation after construction. In addition, in awe zones such as parking lots, although the first image of the Joseon royal tombs is determined, the formation of the functional landscape centered on the carriageway does not harmonize with the traditional landscape, and, because of its lack of walking and environment-friendly features, there is a need for improvement, such as the experimental introduction of relevant pavement materials developed afterwards and continuous monitoring.

Grouting Improvement through Correlation Analysis of Hydrogeology and Discontinuity Factors in a Jointed Rock-Mass (절리 암반의 수리지질 및 불연속면 특성 간 상관분석을 통한 그라우팅 계획 수립의 개선 방안)

  • Kwangmin Beck;Seonggan Jang;Seongwoo Jeong;Minjune Yang
    • The Journal of Engineering Geology
    • /
    • v.34 no.2
    • /
    • pp.279-294
    • /
    • 2024
  • Large-scale civil engineering structures such as dams require a systematic approach to jointed rock-mass grouting to prevent water leakage into the foundations and to ensure safe operation. In South Korea, rock grouting design often relies on the experience of field engineers that was gained in similar projects, highlighting the need for a more systematic and reliable approach. Rock-mass grouting is affected mainly by hydrogeology and the presence of discontinuities, involving factors such as the rock quality designation (RQD), joint spacing (Js), Lugeon value (Lu), and secondary permeability index (SPI). This study, based on data from field investigations of 14 domestic sites, analyzed the correlation between hydrogeological factors (Lu and SPI), discontinuity characteristics (RQD and Js), and grout take, and systematically established a design method for rock grouting. Analysis of correlation between the variables RQD, Js, Lu, and SPI yielded Pearson correlation (r) values as follows: Lu-SPI, 0.92; RQD-Lu, -0.75; RQD-Js, 0.69; RQD-SPI, -0.65; Js-Lu, -0.47; and SPI-Js, -0.41. The grout take increases with Lu and SPI values, but there is no significant correlation between RQD and Js. The proposed approach for grouting design based on SPI values was verified through analysis and comparison with actual curtain-grouting construction, and is expected to be useful in practical applications and future studies.

Behavior Changes of Earthworm from Soils Amended with Biochar - Avoidance and Productivity - (바이오차르 토양 투입에 따른 지렁이의 행동변화 연구 - 회피 및 생산성 변화 -)

  • Kim, You Jin;Yang, Seung Hoon;Kim, Seo Yeon;Yoon, Hong Seok;Yoo, Ga Young
    • Journal of Climate Change Research
    • /
    • v.5 no.4
    • /
    • pp.277-284
    • /
    • 2014
  • Biochar application to soil is widely known to have effects of climate change mitigation and soil quality improvement. However, effects of biochar on soil ecosystem are not always positive and some biochars are reported to contain toxic materials which might influence soil ecosystem. In this context, this study aims to investigate behavioral changes of earthworms(Eisenia fetida, Eisenia andrei) in response to different application rates of biochar to artificial soil. Treatment included two types of biochars made from rice husk (RH_Char) and wastewater sludge (SL_Char) with 1% and 10% application rates, respectively. Avoidance test revealed that earthworms did not avoid SL_Char treatments at 1% and 10%, while they rather moved to the RH_Char treatments probably due to higher labile carbon content(Hot water extractable carbon) of the RH_Char. The HWC content of RH_Char was 4 times higher than that of the SL_Char. Results of reproduction test showed that the survival rates, number of juveniles and number of cocoons were not influenced by biochar application except for the treatment of SL_Char at 10% rate. In the SL_Char 10% treatment, fatality was approximately 3.3 times as high as the control and the number of cocoons was 1.3 times higher in the same treatment than the control, indicating that earthworms were under environmental stress. The possible explanation for the stress condition was related to higher Cd, Ni, Cr, and As contents in the SL_Char. Overall results imply that biochar application at low rate might not change earthworms' behavior for the short term, while the reproduction behavior might be negatively influenced under the high application rate.

Effect of κ-Carrageenan on Sperm Quality in Cryopreservation of Canine Semen (개 정액의 냉동보존 시 κ-Carrageenan이 정자 성상에 미치는 영향)

  • Kim, Eun-Ji;Talha, Nabeel A.H.;Jeon, Yu-Byeol;Yu, Il-Jeoung
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.34 no.1
    • /
    • pp.57-63
    • /
    • 2019
  • This study was conducted to find out the effect that ${\kappa}-Carrageenan$ has on the properties of dog sperm when it was added to the cryoprotectant. Extender basically was contained 1.21 g Trizma base, 0.67 g citric acid, 0.4 g glucose, 0.03 g penicillin G, 0.05 g streptomycin sulfate. Extender1 was added with 0.1%, 0.2%, 0.3%, and 0.5% carrageenan, while extender2 was supplemented with glycerol. After freezing-thawing, the motility, viability, acrosome integrity, apoptosis, and ROS (reactive oxygen specifications) of sperm were measured to analyze the effects of the supplementation of carrageenan. Total Motile (TM), Rapid Progressive Motile (RPM), Medium Progressive Motile (MPM), and Immotile were measured through the CASA system after thawing in 37 degree water. Extender with 0.2% ${\kappa}-carrageenan$ ($64.26{\pm}0.49$) was significantly higher than control ($40.24{\pm}8.27$) (p < 0.05). RPMs of extender with 0.1%, 0.2% ${\kappa}-carrageenan$ ($57.64{\pm}6.34$, $56.47{\pm}1.35$) were significantly higher than the other groups (p < 0.05). Acrosome integrity was measured by dyeing to PSA-FITC with an epifluorescence microscope. Normal acrosome ratio of extender with 0.5% ${\kappa}-carrageenan$ ($61{\pm}8.03$) was higher than the other groups (p < 0.05). Apoptosis was measured with a FACSCalibur flow cytometer using FITC (FITC Annexin V Apoptosis Detection Kit). Treated groups of ${\kappa}-carrageenan$ of 0.1% ($0.81{\pm}0.05$), 0.2% ($0.85{\pm}0.05$) were significantly higer (p < 0.05) than control. Modified SYBR/PI staining was used for determination of viability and DCF staining was used for evaluation of ROS. Viability and ROS were not significantly different from other groups. In conclusion, adding a certain concentration of carrageenan to the extender of cryopreservation, carrageenan contributes to the improvement of the sperm motility, acrosome integrity and prevention of apoptosis.

Biological Impact Prediction and Biological Basic Management by Development of Deokjin Park, Chonju City (전주시 덕진공원의 개발이용에 따른 생물학적인 영향예측과 기초관리방안)

  • Kim, Sei-Cheon;Youn, Chang-Ho;Kim, Ik-Soo
    • Journal of Environmental Impact Assessment
    • /
    • v.6 no.1
    • /
    • pp.77-92
    • /
    • 1997
  • To know of the biological basic method that can improve the environment of the organisms that inhabit at Deokjin Park. We studied the flora and the fauna in Deokjin Park on June, 1996. The study was surveyed and researched according to the items floras, phytoplanktons, insects and vertebrates. The floras are composed of eleven varieties, one forma, eighty-three species, eighty-four genera and forty-nine families. In the lake of Deokjin Park, the dominant species were Nelembo nucifera and Spirodela polyrhiza. The authors thought that those species be artificially excluded in winter for the improvement of the quality of water. The phytoplanktons were composed of forty genera, eighteen families, ten orders and six classes. Among those, Anacystis(=Microcystis) and Anabaena that make eutrophication, were distributed in the lake of Deokjin Park. The fauna of insects were composed of forty-one species, thirty families and eleven orders. The authors observed seven species of fish, two species of amphibian, three species of reptile, seven species of the bird and one species of mammal. Among those, Bull-frog and Blue-turtle as exotic species must be excluded by artificial methods for the other native organisms of the lake of Deokjin Park.

  • PDF

Environmental Capacity Assessment of Busan City (부산시 환경용량평가에 관한 연구)

  • Hwang, Kyung-Yup;Hwang, Inseong;Lee, Soon-Kyu;Jo, Seung-Wu;Oh, Kwang-Joong
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.1
    • /
    • pp.79-92
    • /
    • 2006
  • Environmental capacity assessment of Busan city was conducted to provide basis for planning on sustainable development and growth of the city. Using Onish model, assessment was carried out on amenities and service facilities for the citizens of Busan city. Ecological Footprint model was used to judge if the city exceeds the its environmental capacity and to estimate the extent of the excess if it exists. The analysis using Onish model revealed that the citizens of Busan city are generally well supported by the infrastructure and service facilities of the city. Water treatment and supply facilities have enough capabilities to support the city, whereas the relatively low rate of sanitary sewer supply (78%) suggests the need for further improvement in the wastewater area. The capacities of sanitary landfills are found sufficient enough to support the city for the next 10 years. The high value for the line length served per capita in the subway sector hints on certain inconvenience of commuters. All the air quality indicators meet the Korean and WHO standards except for $NO_2$. The ecological footprint model analysis produced EF indicators for Busan city of 3.04 ha/person and 2.54 ha/person for the years of 1993 and 2003, respectively. The decrease of the indicator from 1993 to 2003 is mainly due to the incorporation of Gijang area by Busan city in 1995, suggesting the importance of the ecologically productive area in the evaluation using this model. The analysis on the ecological deficit that is based on ecologically productive land shows that the consumption by Busan city exceeds its ecologically available production by 19,600% as of 2003. The area needed to support the consumption of Busan city in 2003 is 123 times as large as the present area of Busan city, which is substantially lower than the multiplier (742) obtained for Seoul city in 1997 but is higher than those observed for Chongju city (71 in 1999) and Ulsan city (39 in 2001).