• 제목/요약/키워드: Improved operating characteristics

검색결과 329건 처리시간 0.027초

동축-원추-방사형 전력분할/합성기의 중심부 높이에 따른 최적설계와 아이솔레이션 특성 향상 (On the Optimization of the Coaxial-Conical-Radial Type Power Divider/Combiner and the Improvement of Isolation Characteristics)

  • 최영규
    • 전기학회논문지
    • /
    • 제60권9호
    • /
    • pp.1727-1732
    • /
    • 2011
  • In order to realize a high performance(low loss, high isolation) microwave power divider/combiner, we have designed the power combiner/divider precisely in accordance with the different hight of central part. In the case of the high central part of the hight of $h_r$=10.2, a compensating part of the conical line is inserted in the conical conversion transmission line, and in the case of low central part of the hight of $h_r$=5.0, the conical conversion transmission line is remodeled into the 2-stage bend structure. In both case, the reflection characteristics are improved to 30dB over the operating frequency range of 5GHz bandwidth. A resistance is inserted between the peripheral ports so as to try to improve the isolation characteristics of the device. For the 16-divider/combiner, the isolation characteristics are improved to 10dB over the operating frequency range of 5GHz bandwidth.

5상 5kW 표면부착형 영구자석 동기발전기 특성개선 (An Improved Operating Characteristics of Surface Permanent Magnetic Synchronous Generator for 5-Phase 5kW)

  • 정형우;김민회;송현직;김동희
    • 조명전기설비학회논문지
    • /
    • 제27권9호
    • /
    • pp.53-61
    • /
    • 2013
  • This paper propose a improved operating characteristics of the 5-phase 5kW within developed the surface permanent mount synchronous generator (SPMSG) in order to make a study of a polyphase ac motors keeping hold of more advantages. The developed manufacturing motor was necessary to do improvement of voltage regulation, efficiency, operating characteristics, and so on at the rated load. There are remake a redesigned and distributed stator winding connection without changing the frames of stator and rotor core in previous established generator by a repeat tests. There are shown a amplitude and waveform of the generated electromotive force, FFT analysis of harmonics within output voltages, and reviewing a experiment results in load of resistive and 5-phase induction motor by variable generator output frequency.

5상 1.5kW 농형 유도전동기의 운전특성 (Operating Characteristics of Squirrel-Cage Induction Motor of 5-Phase 1.5kW)

  • 김민회;정형우;송현직
    • 조명전기설비학회논문지
    • /
    • 제28권5호
    • /
    • pp.52-59
    • /
    • 2014
  • This paper presents an improved operating characteristics of squirrel-cage induction motor(IM) for 5-phase 1.5kW, 220V, 60Hz in order to study a polyphase AC machinery that keep hold of advantages more than traditional three-phase a IM, such as reducing a amplitude of torque pulsation, decreasing electric noises, and increasing the reliability. The developed manufacturing motor was necessary to do improvement of speed regulation, efficiency, operating characteristics, and so on at rated load. There are remake a redesigned and distributed stator winding connection without changing the frames of stator and rotor core in previous established the motor by a repeat tests. There are shown a experiments results of no-load test, locked rotor test, operating characteristics at variable load, FFT analysis of harmonics within output voltages and current waveform, decided motor parameters.

The Design of Flux Barrier for Improvement of Demagnetization Endurance in BLDC Motor

  • Kim, Cheol-Min;Kim, Dong-Yeong;Cho, Gyu-Won;Kim, Gyu-Tak
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2181-2186
    • /
    • 2014
  • Generally, the motor inside vehicle is exposed to highly ambient temperature and large vibration according to repeatedly starting and stopping for very short time. So, in this paper, the rotor shape design was performed to improve demagnetization endurance by considering the starting current of the Brushless DC (BLDC) Motor through the Finite Element Method(FEM). As a result, the partial irreversible demagnetization was occurred by starting current at the end of Permanent Magnets of the basic model. To solve this problem, the flux barrier design was performed and the flux on the rotor core was limited. Accordingly, demagnetization endurance and operating characteristics were improved.

영구자석의 불가역 감자 현상을 고려한 BLDC 전동기의 회전자 자속 장벽 설계 (The Rotor Barrier Design of the BLDC Motor Consider that Irreversible Demagnetization of Permanent Magnets)

  • 김철민;조규원;김규탁
    • 전기학회논문지
    • /
    • 제63권1호
    • /
    • pp.48-53
    • /
    • 2014
  • Generally, the usage motor in the vehicle is exposed to highly ambient temperature and large vibration according to repeatedly starting and stopping during very short time. So, in this paper, the rotor shape design was performed to improve demagnetization endurance by considering starting current of Brushless DC Motor (BLDCM) through Finite Element Method(FEM). As a result, the end of Permanent Magnet (PM) in the basic model was occurring a partial irreversible demagnetization by starting current. To solve this problem, the installing flux barrier was limited to flux line on the core. Accordingly, demagnetization endurance and operating characteristics were improved.

Sensitivity Improvement and Operating Characteristics Analysis of the Pressure Sensitive Field Effect Transistor(PSFET) Using Highly-Oriented ZnO Piezoelectric Thin Film

  • 이정철;조병욱;김창수;남기홍;권대혁;손병기
    • 센서학회지
    • /
    • 제6권3호
    • /
    • pp.180-187
    • /
    • 1997
  • We demonstrate the improvement of sensitivity and analysis of operating characteristics of the piezoelectric pressure sensor using ZnO piezoelectric thin film and FET(field effect transistor) for sensing applied pressure and transforming the pressure into electrical signals, respectively. The sensitivity of the PSFET(pressure sensitive field effect transistor) was improved by using highly-oriented ZnO film perpendicular to the substrate surface and the operating characteristics was investigated by monitoring output voltage with time in various static pressure levels.

  • PDF

MPA 유량계 압력감지공의 위치와 유출계수 (Location of pressure sensing holes in MPA flowmeter and discharge coefficients)

  • 김기현;최성길
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.160-165
    • /
    • 2004
  • MPA (Multi-Point Averaging) flow element is a new type of differential pressure (DP) flow-sensing device that was developed by Seojin Instech to improve the operating characteristics of the conventional Averaging Pilot Tube (APT) flow elements. Operating characteristics of a flowmeter in general can be defined in terms of measurement accuracy and range. Improvement of accuracy and expanding the range of flow measurement were the two main objectives of the development. To achieve these dual objectives several upstream and downstream pressure-sensing holes were placed in MPA flow element. During the course of the development it was found that certain arrangements of the pressure-sensing holes improved measurement accuracy but did not expand operating flow range of Averaging Pilot Tubes. Development tests were performed with water between Reynolds number of 50,000 and 1,000,000 in the four-inch test line at the Alden Research Laboratory, U.S.A. Purpose of this paper is to present the relationship between the various locations of the pressure-sensing holes and the performance characteristics of MPA flow element. Furthermore, the operating characteristics of the best performing MPA are compared with those of typical orifice and APT.

  • PDF

신규원전의 설계특성 기반 정비효과성감시 프로그램 개발 (Development of Maintenance Effectiveness Monitoring Program based on Design Characteristics for New Nuclear Power Plant)

  • 염동운;현진우;송태영
    • 한국압력기기공학회 논문집
    • /
    • 제8권1호
    • /
    • pp.25-32
    • /
    • 2012
  • Korea Hydro & Nuclear Power Co. (KHNP) has developed and implemented the maintenance effectiveness monitoring (MR) programs for the operating nuclear power plants. The MR program is developed by reflecting design characteristics of the operating nuclear power plants to monitor the plant performance for improving the safety and reliability. Recently, KHNP has built a new nuclear power plant, and developed the MR program to establish the advanced maintenance system by reflecting unique design characteristics based on the OPR1000 standard model. So, the MR program developed in this study has another characteristics in comparison with the OPR1000 standard model, and we will verify the suitability of the MR program through evaluating initial performance of the plant. The safety and reliability of the new plant will be improved by developing and implementing the MR program.

SI 엔진에서 바이오에탄올 연료(E100)의 연소 및 배기특성 (Combustion and Exhaust Emission Characteristics of Bio-Ethanol Fuel(E100) in SI Engine)

  • 하성용;이창식
    • 대한기계학회논문집B
    • /
    • 제32권8호
    • /
    • pp.582-588
    • /
    • 2008
  • An experimental investigation was conducted to investigate the effect of Bio-ethanol fuel on the engine performance and exhaust emission characteristics under various engine operating conditions. To investigate the effect of bio-ethanol fuel, the commercial 1.6L SI engine equipped with 4 cylinder was tested on EC dynamometer. The engine performance including brake torque, brake specific fuel consumption, and barke specific energy consumption of bio-ethanol fuel was compared to those obtained by pure gasoline. Furthermore, the exhaust emissions were analyzed in terms of regulated exhaust emissions such as unburned hydrocarbon, oxides of nitrogen, and carbon monoxide.Result of this work shows that the effect of blending of ethanol to gasoline caused drastic decrease of emissions under various operating conditions. Also, improved engine performance such as brake torque and brake power were indicated for bio-ethanol fuel.

디젤기관에 있어서 개선 미강유 연료의 배기 배출물 특성에 관한 연구 (A Study on Characteristics of Exhaust Emissions in a Diesel Engine with Improved Rice Bran Oils as a Fuel)

  • 배명환;하정호
    • 한국자동차공학회논문집
    • /
    • 제12권4호
    • /
    • pp.12-23
    • /
    • 2004
  • The effects of improved rice bran oil on the characteristics of exhaust emissions have been experimentally examined by a single cylinder, four cycle, direct injection, water-cooled agricul-tural diesel engine operating at several loads and speeds. The experiments are conducted with light oil, rice bran oil, and improved rice bran oil as a fuel. The fuel injection timing is fixed to 22$^{\circ}$ BTDC regardless of fuel types, engine loads and speeds. To reduce the viscosity of rice bran oil, it is used with the methods of heating, methyl ester and ultrasonic system in a highly viscous rice bran oil. In this study, it is found that the brake specific fuel consumption rate of light oil is the lowest and that of improved rice bran oils is lower than that of pure rice bran oil, and NO$_{x}$ emissions of light oil are the lowest and those of pure rice bran oil are the high- est, while soot emissions of light oil are the highest and those of pure and improved rice bran oils are lower than that of light oil. However these results are not amply satisfied with the emissions regulation limit using the pure and improved rice bran oil as fuels in diesel engines.s.