• Title/Summary/Keyword: Improved loop stability

Search Result 77, Processing Time 0.026 seconds

Novel Method for Circulating Current Suppression in MMCs Based on Multiple Quasi-PR Controller

  • Qiu, Jian;Hang, Lijun;Liu, Dongliang;Geng, Shengbao;Ma, Xiaonan;Li, Zhen
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1659-1669
    • /
    • 2018
  • An improved circulating current suppression control method is proposed in this paper. In the proposed controller, an outer loop of the average capacitor voltage control model is used to balance the sub-module capacitor voltage. Meanwhile, an individual voltage balance controller and an arm voltage balance controller are also used. The DC and harmonic components of the circulating current are separated using a low pass filter. Therefore, a multiple quasi-proportional-resonant (multi-quasi-PR) controller is introduced in the inner loop to eliminate the circulating harmonic current, which mainly contains second-order harmonic but also contains other high-order harmonics. In addition, the parameters of the multi-quasi-PR controller are designed in the discrete domain and an analysis of the stability characteristic is given in this paper. In addition, a simulation model of a three-phase MMC system is built in order to confirm the correctness and superiority of the proposed controller. Finally, experiment results are presented and compared. These results illustrate that the improved control method has good performance in suppressing circulating harmonic current and in balancing the capacitor voltage.

Stability Analysis of FCHEV Energy System Using Frequency Decoupling Control Method

  • Dai, Peng;Sun, Weinan;Xie, Houqing;Lv, Yan;Han, Zhonghui
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.490-500
    • /
    • 2017
  • Fuel cell (FC) is a promising power supply in electric vehicles (EV); however, it has poor dynamic performance and short service life. To address these shortcomings, a super capacitor (SC) is adopted as an auxiliary power supply. In this study, the frequency decoupling control method is used in electric vehicle energy system. High-frequency and low-frequency demand power is provided by SC and FC, respectively, which makes full use of two power supplies. Simultaneously, the energy system still has rapidity and reliability. The distributed power system (DPS) of EV requires DC-DC converters to achieve the desired voltage. The stability of cascaded converters must be assessed. Impedance-based methods are effective in the stability analysis of DPS. In this study, closed-loop impedances of interleaved half-bridge DC-DC converter and phase-shifted full-bridge DC-DC converter based on the frequency decoupling control method are derived. The closed-loop impedance of an inverter for permanent magnet synchronous motor based on space vector modulation control method is also derived. An improved Middlebrook criterion is used to assess and adjust the stability of the energy system. A theoretical analysis and simulation test are provided to demonstrate the feasibility of the energy management system and the control method.

Improved Deadbeat Current Controller with a Repetitive-Control-Based Observer for PWM Rectifiers

  • Gao, Jilei;Zheng, Trillion Q.;Lin, Fei
    • Journal of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.64-73
    • /
    • 2011
  • The stability of PWM rectifiers with a deadbeat current controller is seriously influenced by computation time delays and low-pass filters inserted into the current-sampling circuit. Predictive current control is often adopted to solve this problem. However, grid current predictive precision is affected by many factors such as grid voltage estimated errors, plant model mismatches, dead time and so on. In addition, the predictive current error aggravates the grid current distortion. To improve the grid current predictive precision, an improved deadbeat current controller with a repetitive-control-based observer to predict the grid current is proposed in this paper. The design principle of the proposed observer is given and its stability is discussed. The predictive performance of the observer is also analyzed in the frequency domain. It is shown that the grid predictive error can be decreased with the proposed method in the related bode diagrams. Experimental results show that the proposed method can minimize the current predictive error, improve the current loop robustness and reduce the grid current THD of PWM rectifiers.

PD controller design for Micro Gyroscope and Its Performance Test (마이크로 자이로스코프를 위한 PD 제어기 설계 및 성능시험)

  • Sung, Woon-Tahk;Song, Jin-Woo;Lee, Jang-Gyu;Kang, Tae-Sam
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.47-56
    • /
    • 2005
  • This paper presents a performance improvement result with the aid of closed feedback controller loop to a micro gyroscope. The dynamic model of a micro gyroscope is derived and a conventional proportional and derivative controller is designed via frequency domain analysis. The proposed control loop is implemented using several analog devices and applied to the SNU-Bosch MEMS gyroscope to check its performance improvement in real environment. The experiments demonstrated the performance improvement with the proposed feedback control loop. The bandwidth, linearity, and bias stability are improved to 78 Hz, 0.504 %, and 0.043 deg/sec, respectively, from 35 Hz, 2.07 %, and 0.066 deg/sec of open loop system.

Model updation using multiple parameters influencing servoelastic response of a flexible aircraft

  • Srinivasan, Prabha;Joshi, Ashok
    • Advances in aircraft and spacecraft science
    • /
    • v.4 no.2
    • /
    • pp.185-202
    • /
    • 2017
  • In a flexible airvehicle, an assessment of the structural coupling levels through analysis and experiments provides structural data for the design of notch filters which are generally utilized in the flight control system to attenuate the flexible response pickup. This is necessitated as during flight, closed loop control actuation driven with flexible response inputs could lead to stability and performance related problems. In the present work, critical parameters influencing servoelastic response have been identified. A sensitivity study has been carried out to assess the extent of influence of each parameter. A multi-parameter tuning approach has been implemented to achieve an enhanced analytical model for improved predictions of aircraft servoelastic response. To illustrate the model updation approach, initial and improved test analysis correlation of lateral servoelastic responses for a generic flexible airvehicle are presented.

Anti-shock Controller Design for Optical Disk Drive Systems with a Nonlinear Controller (광디스크 드라이브 시스템을 위한 비선형 Anti-shock 제어기 설계)

  • Baek Jong-Shik;Chung Chung Choo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.9
    • /
    • pp.741-749
    • /
    • 2005
  • This paper presents a nonlinear controller design for optical disk drive systems to improve anti-shock performance. The nonlinear anti-shock controller is added parallel to the original linear servo control loop. In the previous work, a dead-zone nonlinear element is used for the nonlinear controller and a PID control method is used for the linear controller. Although this parallel structure of the controller improves anti-shock performance, it has a narrow stability bound. In this paper, the dead-zone with saturation nonlinear element is proposed for the nonlinear controller. Since this nonlinear element improves stability margin, we can use higher slope gain of dead-zone than that of nonlinear controller using dead-zone only. In the linear controller design, it is shown that the lead-lag control has an improved stability margin over PID control. Numerical simulation results and experimental results show that the proposed method can get better performance to the external shock than previously proposed methods.

Design and Implementation of a 40 Gb/s Clock Recovery Module Using a Phase-Locked Loop with the Clock-Hold Function (클락 유지 기능을 가지는 위상 고정 루프를 사용한 40 Gb/s 클락 복원 모듈 설계 및 구현)

  • Park Hyun;Woo Dong-Sik;Kim Jin-Jung;Lim Sang-Kyu;Kim Kang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.2 s.105
    • /
    • pp.171-177
    • /
    • 2006
  • A low-cost, high-performance 40 Gb/s clock recovery module using a phase-locked loop(PLL) for a 40 Gb/s optical receiver with the clock-hold function has been designed and implemented. It consists of a clock extractor circuit, an RF mixer and a frequency discriminator for phase/frequency detection, a VC-DRO, a phase shifter, and a clock-hold circuit. The extracted 40 GHz clock is synchronized with a stable 10 GHz VC-DRO. The clock stability and jitter characteristics of the implemented PLL-based clock recovery module are significantly improved as compared with those of the conventional open-loop type clock recovery module with a DR filter. The measured peak-to-peak RMS jitter is about 230 fs. When an input signal is dropped, the 40 GHz clock is maintained continuously by the hold circuit.

Tuning PID Controllers for Unstable Systems with Dead Time based on Dual-Input Describing Function(DIDF) Method (DIDF를 적용한 PID 제어기의 파라미터 설정법 - 불감시간을 가지는 불안정한 시스템의 경우)

  • Choe, YeonWook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.509-518
    • /
    • 2014
  • Though various techniques have been studied as a way of adjusting parameters of PID controllers, no perfect method of determining parameters is available to date. Especially the deign of PID controller for unstable processes with dead time(UPWDT) is even more difficult due to various reasons. Generally the existing design procedures for UPWDT involve deriving formulas to meet gain and phase margin specifications, or using inner loop to stabilize UPWDT before applying PID controller. In this paper, the dual-input describing function(DIDF) method is proposed, by which the performance and robustness of the closed-loop system can be improved. The method is based on moving the critical point (-1+j0) of Nyquist stability to a new position arbitrarily selected on the complex plane. This can be done by determining appropriate coefficients of the DIDF. As a result, we can easily determine parameters of PID-type controller by using existing conventional tuning methods for stable or unstable systems. Simulation results are included to show the effectiveness of the proposed method.

The Minimization of Generator Output Variations by Impulse Chamber Pressure Control during Turbine Valve Test (터빈 밸브시험 중 충동실 압력제어에 의한 발전기 출력변동 최소화)

  • Choi, In-Kyu;Kim, Jong-An;Park, Doo-Yong;Woo, Joo-Hee;Shin, Jae-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.152-159
    • /
    • 2010
  • This paper describes the actual application of a feedback control loop as a means for minimizing turbine impulse chamber pressure variation during the turbine steam valve tests at a 1,000 MW nuclear power plant. The chamber pressure control loop was implemented in the new digital control system which was installed as a replacement for the old analog type control system. There has been about 40MW of the generator output change during the steam valve tests, especially the high pressure governing valve tests, because the old control system had not the impulse chamber pressure control so the operators had to compensate steam flow drop manually. The process of each valve test consists of a closing process and an reopening process and the operators can make sure that the valves are in their sound conditions by checking the valves movement. The control algorithm described in this paper contributed to keep the change in megawatt only to 6MW during the steam valve tests. Thereby, the disturbance to reactor control was reduced, and the overall plant control system's stability was greatly improved as well.

A Study on High Performance Controller Design of Elastic Maniplator (탄성매니퓰레이터의 고성능 제어기 설계에 관한 연구)

  • Lee, Ji-U;Han, Seong-Hyeon;Lee, Man-Hyeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.3
    • /
    • pp.73-82
    • /
    • 1992
  • An industrial robot, installed real manufacturing processes an element of the system autmation, can be considered as an uncertain system due to dynamic uncertainties in inertial parameters and varying payloads. Most difficuties in controlling a robot manipulator are caused by the fact that the dynamic equations describing the motions of the manipulator are inherently nonlinear and heavily coupled effects between joints and associated links. Existing robot conrol systems have constant predefined gains and do not cover the complex dynamic interactions between manipulator joints. As a result, the manipulator is severly limited in range of application, speed of operation and variation of payload. The proposed controller is operated by adjusting its gains based on the response of the manipulator in such a way that the manipulator closely matches the reference model trajectories defined by the desinger. The proposed manipulator studied has two loops, an inner loop of model reference adaptive controller and an outer loop of state feedback controller with integral action to guarantee the stability of the adaptive scheme. This adaptation algorithm is based on the hyperstailiy approach with an improved Lyapunov function. The coupling among joints and the nonlinearity in the dynamic equation are explicitly considered. The designed manipulator controller shows good tracking performance in practical working environment, various load variations and parameter uncertainties.

  • PDF