• Title/Summary/Keyword: Impression surface

Search Result 117, Processing Time 0.021 seconds

Accuracy of dies fabricated by various three dimensional printing systems: a comparative study (다양한 삼차원 프린팅 시스템으로 제작된 다이의 정확도 비교)

  • Baek, Ju Won;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.242-253
    • /
    • 2020
  • Purpose: The aim of this study was to compare the accuracy of dies fabricated using 3D printing system to conventional method and to evaluate overall volumetric changes by arranging the superimposed surfaces. Materials and Methods: A mandibular right first molar from a dental model was prepared, scanned and fabricated with composites of polyetherketoneketone (PEKK). Master dies were classified into 4 groups. For the conventional method, the impression was taken with polyvinylsiloxane and the impression was poured with Type IV dental stone. For the 3D printing, the standard die was scanned and converted into models using three different 3D printers. Each of four methods was used to make 10 specimens. Scanned files were superimposed with the standard die by using 3D surface matching software. For statistical analysis, Kruskal-Wallis test and Mann-Whitney U test were done (P < 0.05). Results: Compared to the standard model, the volumetric changes of dies fabricated by each method were significantly different except the models fabricated by conventional method and 3D printer of Stereolithography (P < 0.05). The conventional dies showed the lowest volumetric change than 3D printed dies (P < 0.05). 3D printed dies fabricated by Stereolithography showed the lowest volumetric change among the different 3D printers (P < 0.05). Conclusion: The conventional dies were more accurate than 3D printed dies, though 3D printed dies were within clinically acceptable range. Thus, 3D printed dies can be used for fabricating restorations.

Comparative study on quality of scanned images from varying materials and surface conditions of standardized model for dental scanner evaluation (치과용 스캐너 평가를 위한 국제표준모델의 재료 및 표면 상태에 따른 스캔 영상 결과물 비교 연구)

  • Park, Ju-Hee;Seol, Jeong-Hwan;Lee, Jun Jae;Lee, Seung-Pyo;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.104-115
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the image acquisition ability of intraoral scanners by analyzing the comprehensiveness of scanned images from standardized model, and to identify problems of the model. Materials and Methods: Cast models and 3D-printed models were prepared according to international standards set by ISO12836 and ANSI/ADA no. 132, which were then scanned by model scanner and two different intraoral scanners (TRIOS3 and CS3500). The image acquisition performance of the scanners was classified into three grades, and the study was repeated with varying surface conditions of the models. Results: Model scanner produced the most accurate images in all models. Meanwhile, CS3500 showed good image reproducibility for angled structures and TRIOS3 showed good image reproducibility for rounded structures. As for model ingredients, improved plaster model best reproduced scan images regardless of the type of scanner used. When limited to 3D-printed model, powdered surface condition resulted in higher image quality. Conclusion: When scanning structures beyond FOV (field of view) in standardized models (following ISO12836 and ANSI/ADA 132), lack of reference points to help distinguish different faces confuses the scanning and matching process, resulting in inaccurate display of images. These results imply the need to develop a new standard model not confined to simple pattern repetition and symmetric structure.

THE EFFECT OF DENTURE CLEANSERS ON SOFT LINING MATERIALS (의치 세정제가 탄성 의치상 이장재에 미치는 효과에 관한 연구)

  • Jang, Bok-Sook;Kim, Chang-Whe;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.219-235
    • /
    • 1993
  • To determine the compatibilities of soft liming materials with denture cleansers by measuring the flexibility and elasticity and investigating the surface changes, 4 self-curing acrylic resin soft lining materials and 1 heat-curing silicone soft lining material were evaluated. 3mm thick x 20mm diameter discs of soft lining materials were individually bonded to a hard acrylic resin base as per manufacturers’instructions. Using an Instron universal testing machine, a static stress of $2kg/cm^2$ was applied for 30secs., the strain in compression was measured, giving an indication of the material’s flexibility. Elastic recovery was measured at 10secs. After removal of stress. Surface changes were investigated with Stereomicroscope. Then the specimens were immersed in 4alkaline peroxide denture cleansers and water as control group, tests were carried out at 1 day, 2 days, 7 days, 14 days and 30 days. The results were as follows : 1. Alkaline peroxide denture cleansers caused considerable porosity on the surface of selfcuring acrylic resin soft lining materials, and the most affected by the cleansers were Viscogel, Coe-Soft, Coe-Comfort, Lynal, in that order. 2. There was significant difference in flexibility between each soft lining material except for Coe-Comfort and Visco-gel, and every soft lining material was significant difference in elasticity. Especially Molloplast-B and Lynal were less flexible and more elastic than other soft lining materials(p<0.05). 3. The denture cleansers increased the flexibility and elasticity of the soft lining materials compared with control group(p<0.05), and Denalan, Polident, Kleenite, Efferdent affected the soft lining materials in that order. 4. There was significant difference in flexibility between each denture cleanser except for Denalan and Polident(p<0.05). Though Denalan and Polident, Denalan and Kleenite did not show significant difference in elasticity, other denture cleansers showed significant difference among each other(p<0.05). 5. Clinically Coe-Comfort, Coe-Soft and Visco-gel were incompatible with alkaline peroxide denture cleansers, and Lynal would be used within only 2 weeks. But Molloplast-B was compatible with alkaline peroxide denture cleansers.

  • PDF

A Study Practice of Infection Control for Dental Office and Dental Hygienist and Bacterial Contamination of Dental Office Surface (치과 의료기관 및 치과위생사의 감염관리 실천도와 진료실내의 표면 세균오염도에 대한 연구)

  • Yun, Kyoung-Ok;Bae, Sung-Suk;Choi, Young-Suk
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.5
    • /
    • pp.511-519
    • /
    • 2019
  • The purpose of this study was to investigate the status of infection control in dental office and the degree of infection control practice of dental hygienists. A self-reported questionnaire was answered by 193 dental hygienists working in dental hospitals or dental clinics in Gyeonggi and Incheon areas. The number of bacteria was measured sample of surface dental unit chair shoulder backrests and light handles from 19 dental hospitals and 28 dental clinics. It was responded that impression or occlusion bodies were routinely disinfected in 52.6% of the dental hospitals and dental prosthesis were routinely disinfected in 46.4% in dental clinics. The dental hospital and clinics disinfect the surface each 26.3%, 25% after the patient treatment. The dental hospital and clinic were detected bacteria $5.02^*10\^3CFU/mL$, $1^*10\^4CFU/mL$, from dental unit chair backrest, respectively and $8.32^*10\^3CFU/mL$, $4.26^*10\^4CFU/mL$ from light handles, respectively. At the conclusion of this investigation, it can be kept from infection source in dental office is to make the right selection and use of the personal protective equipments and to improve the practice level by regular and active education. The same infection control practice should be done by institutionalizing and mandating infection control practice.

Complete denture fabricated by Jiro Abe's method for edentulous patient with severe alveolar ridge resorption: a case report (심한 치조제 흡수를 보이는 무치악 환자에서 Jiro Abe법에 의한 완전틀니 제작 증례)

  • Jun, Daejeon;Yang, Dong-Hun;Vang, Mongsook;Yang, Hongso;Park, Sangwon;Yun, Kwidug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.338-345
    • /
    • 2014
  • Fabrication of complete denture by Jiro Abe's method was introduced that enhance the retention and stability of denture by sealing around the denture border with mucous membrane to make negative pressure at the inner surface of denture base when swallowing or occlusion. In this case, taking impression and fabricating complete denture by the Jiro Abe's method for an edentulous patient with severe mandibular alveolar bone resorption allowed us to obtain clinically enhance stability of denture and improve satisfaction of patient.

Identification of Morphological Appearance of Fine Seed Herbs Using Stereoscope (Report I) - Celosiae Semen, Celoisae Cristatae Semen, Cuscutae Semen, Perillae Semen (Stereoscope를 이용한 미세종자류 한약재 외부형태 감별연구(제1보(報)) - 청상자(靑葙子) 계관자(鷄冠子) 토사자(菟絲子) 자소자(紫蘇子))

  • Ji, Chang-Yoon;Kim, Tae-Ju;Lee, Seung-Ho;Kim, Young-Sik;Lee, Guem-San;Kim, Jung-Hoon;Choi, Goya;Ju, Young-Sung
    • The Journal of Korean Medicine
    • /
    • v.34 no.3
    • /
    • pp.1-12
    • /
    • 2013
  • Objectives: This was study about identifying fine seed herbs that are highly mixed together: Celosiae Semen, Celoisae Cristatae Semen, Cuscutae Semen, Perillae Semen. Methods: In non-distinctive herbs through sensory test, we can find accurate discriminative points by using a stereoscope. As a result, a new discriminative key was completed. Results: We identified a comparison of herbs which are mixed up in distribution. 1) In the case of Celosiae Semen and Celoisae Cristatae Semen, Celoisae Cristatae Semen which is mixed up is bigger and more glossy and especially have the sunk umbilicus. 2) In the case of Cuscutae Semen and Perillae Semen, Perillae Semen is discriminated by characteristic morado netting surface and impression of fruit stalk in the single-ended. 3) In the case of Cuscutae Semen which is distributed in three species, we discriminated by beak shape, location of umbilicus and vomiting thread shape or not when put in water. (1) Cuscuta chinensis has a weak beaky shape, an umbilicus in center and is vomiting thread shape when put in water. (2) C. australis has very weak beaky shape, an umbilicus beneath and is vomiting thread shape when put in water. (3) C. japonica has clear beaky shape, an umbilicus beneath and is not vomiting thread shape when put in water. Conclusions: A stereoscope can be effectively used for identifying fine seed herbs hardly distinguishable by sensory tests.

Effect of two-phase fabrication method for the optimum fit of light-polymerized record bases

  • Huh, Jung-Bo;Kang, Min-Goo;Shin, Sang-Wan;Ryu, Jae-Jun
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.3
    • /
    • pp.102-105
    • /
    • 2010
  • PURPOSE. The aims of this study were to suggest a method of fabrication of the record base using a light-polymerized resin by applying the two-phase fabrication method for the improvement of the fit of the record base and to compare the degree of fit according to the separation site. MATERIALS AND METHODS. In the edentulous cast of maxilla, four test groups were considered. In the first, second, third, and fourth test groups (n = 12 in each group) the separation was done at 0, 5, 10, and 15 mm, respectively below the alveolar crest along the palatal plane. For the control group, the record base was made without separating the two sections. The light-body silicone material was injected into the fitting surface of the record base. It was then placed onto the cast and finger pressure was applied to stabilize it in a seated position followed by immediate placement onto the universal test device. Finally, the mass of the impression material was measured after it was removed. ANOVA was performed using the SAS program. For the post-hoc test, the Wilcoxon Rank-Sum test and the Tukey-Kramer HSD test were performed ($\alpha$ = 0.05). RESULTS. The control group and Group 3, 4 showed significant differences. The Group 3 and 4 showed significantly smaller inside gaps than the control group which was not made with the two-phase fabrication method. CONCLUSION. The two-stage polymerized technique can improve the fit of the denture base particularly when the separation was made at 10 to 15 mm from the alveolar crest.

A Study on the 'Transparency' of Office Lobbies (오피스 로비 공간에 나타난 '투명성'의 표현에 관한 연구)

  • Lee, Hyo-Chang;Ha, Mi-Kyoung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.113-118
    • /
    • 2006
  • The lobby is the space that contributes the most to conveying the first impression of an enterprise or company that is occupying a building, and enhances the quality of the urban or business environment around an office building. Transparency is the biggest change in architecture since the modern age began, and it is the most important element of the lobby expression methods. Therefore this study was an attempt to understand the expression method of transparency which is expressed in the lobby space of office buildings, and used documentary survey and field survey to analyze it. In the examination of the theoretical background of transparency to make a specific study purpose, and based on an on-the-spot probe document, an attempt was made to grasp the expression method of Visual Transparency and Phenomenal Transparency. The data collected during this investigation was studied and a correlation coefficient. A summary of the findings of this study is as follows: 1) Transparent materials does not appear often in floors. But Phenomenal Transparency material is used in the floor. 2) During the survey it was discovered that Visual Transparency was often used in the walls of each investigated building. Phenomenal Transparency materials are found less in walls than in the floors of lobbies. 3) The expression methods that appeared the most in ceilings among the Visual Transparent expression methods. In the case of Phenomenal Transparency, the highest distribution is seen in ceilings. 4) The result of the analyzation of the correlation coefficient of Visual Transparency and Phenomenal Transparency is as follows: Expression method: There is more than one expression method of transparency, 'Open Sight', 'Light Material' and 'Surface Material' methods were introduced in case of the introduction of 'Transparent Material' among Visual Transparency in office building lobby space planning. If the 'Superimposed Space' method is introduced, then the 'Ambiguous Border' or 'Dual Sight' methods are introduced.

  • PDF

SPACIAL POEM: A New Type of Experimental Visual Interaction in 3D Virtual Environment

  • Choi, Jin-Young
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02b
    • /
    • pp.405-410
    • /
    • 2008
  • There is always a rhythm in our language and speech. As soon as we speech out, even just simple words and voice we make are edited as various emotions and information. Through this process we succeed or fail in our communication, and it becomes a fun communication or a monotonous delivery. Even with the same music, impression of the play can be different according to each musician' s emotion and their understanding. We 'play' our language in the same way as that. However, I think, people are used to the variety, which is, in fact, the variation of a set format covered with hollow variety. People might have been living loosing or limiting their own creative way to express themselves by that hollow variety. SPACIAL POEM started from this point. This is a new type of 'real-time visual interaction' expressing our own creative narrative as real-time visual by playing a musical instrument which is an emotional human behavior. Producing many kinds of sound by playing musical instruments is the same behavior with which we express our emotions through. There are sensors on each hole on the surface of the musical instrument. When you play it, sensors recognize that you have covered the holes. All sensors are connected to a keyboard, which means your playing behavior becomes a typing action on the keyboard. And I programmed the visual of your words to spread out in a virtual 3D space when you play the musical instrument. The behavior when you blow the instrument, to make sounds, changes into the energy that makes you walk ahead continuously in a virtual space. I used a microphone sensor for this. After all by playing musical instrument, we get back the emotion we forgot so far, and my voice is expressed with my own visual language in virtual space.

  • PDF

Complete denture rehabilitation of fully edentulous patient with severe bone resorption and class II jaw relation using piezography (심한 골 흡수와 2급 악간관계를 보이는 완전 무치악 환자의 Piezography를 이용한 총의치 수복)

  • Kwon, Wooil;Song, Young-Gyun;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.445-450
    • /
    • 2016
  • Piezography, prosthetic space recorded by pronunciation, can be used as a reference for arrangement of artificial teeth and polishing surface of a denture. In this case, a 67 year old female patient was presented for new dentures. Old dentures had class II relationship and poor retention. For fabrication of stable dentures, using piezography and lingualized occlusion was planned. After taking impressions with conventional method, conventional denture bases with wax rim were fabricated. Then, additional mandibular denture base was fabricated for piezography. With fast setting silicon impression material, piezography was recorded by using six pronunciations, 'si', 'so', 'me', 'te', 'de', and 'mu'. According to the piezographic space, mandibular artificial teeth were arranged and modified for lingualized occlusion. As a result, the patient was satisfied with new dentures functionally and esthetically.