• Title/Summary/Keyword: Impression surface

Search Result 117, Processing Time 0.032 seconds

Comparative evaluation of marginal and internal fit of three-unit Co-Cr frameworks fabricated by metal milling and direct metal laser sintering methods (금속 밀링과 직접 금속 레이저 소결 방식으로 제작한 3본 코발트-크롬 구조물의 변연 및 내부 적합도 비교 평가)

  • Ahn, Jae-Seok;Lee, Jung-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.81-89
    • /
    • 2020
  • Purpose: This in vitro study was conducted to evaluate the marginal and internal fit of three-unit Co-Cr frameworks fabricated by computer-aided metal milling and direct metal laser sintering(DMLS) systems in comparison to conventional casting method. Methods: Three-unit Co-Cr frameworks were fabricated by conventional wax up with casting(CWC), computer-aided metal milling(MM) and direct metal laser sintering(DMLS)(n=10 each). The marginal and internal fit of specimens were examined using a light-body silicone impression material. The thickness of light-body silicone was measured at eight reference points each, divided in the mesio distal and bucco lingual directions. All measurements were conducted by a stereomicroscope. Digital photos were taken at 150× magnification and then analyzed using a measurement software. The Kruskal-Wallis test and Bonferroni correction were used for analyzing the results. Results: The mean(SD) is ㎛ for fabrication methods, the mean marginal fit were recorded respectively, DMLS 39(27), followed by CWC 63(38), MM 220(128). and the mean internal fit CWC 95(47), DMLS 116(49), MM 210(152). In addition, the largest gap was found in the occlusal surface area among the internal measurement areas of all groups. Conclusion: As a result, the direct metal laser sintering method showed better marginal and internal fit than the metal milling method. The marginal and internal fit were statistically different according to the three fabrication methods(p<0.001). Except the MM group, the marginal fit of the CWC and DMLS groups was below the clinical standard of 120 ㎛. Based on the results of this study, it can be applied to clinical use in the future.

A Human Case Infected by the Larva of Terranova type A in Korea (Terrunoua type A 유촉에 의한 인체감염 1예)

  • 서병설;채종일이순형홍성함
    • Parasites, Hosts and Diseases
    • /
    • v.22 no.2
    • /
    • pp.248-252
    • /
    • 1984
  • A human case infected with Terranova type A larva was found in Korea. The patient was a 23-year old soldier of the Korean Army and the chief complaint was acute abdominal pain. The pain was chiefly at right lower quadrant. Appendectomy was performed under the clinical impression of acute appendicitis. However, during the surgery, a nematode larva was found moving on the serosal surface of terminal ileum. The worm was 25.76mm long and O. 66mm -wide, and had the intestinal cecum reaching to anterior one-third level of ventriculus and a mucron at posterior end. Therefore, it was diagnosed as Terranova type A larva. This is the first human case of Terranova type A larva infection in Korea.

  • PDF

Evaluation of the marginal and internal fit of a single crown fabricated based on a three-dimensional printed model

  • Jang, Yeon;Sim, Ji-Young;Park, Jong-Kyoung;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.367-373
    • /
    • 2018
  • PURPOSE. To evaluate the fit of a crown produced based on a 3D printed model and to investigate its clinical applicability. MATERIALS AND METHODS. A master die was fabricated with epoxy. Stone dies were fabricated from conventional impressions (Conventional stone die group: CS, n=10). Digital virtual dies were fabricated by making digital impressions (Digital Virtual die group: VD, n=10). 3D data obtained from the digital impression was used to fabricate 3D printed models (DLP die group: DD, n=10, PolyJet die group: PD, n=10). A total of 40 crowns were fabricated with a milling machine, based on CS, VD, DD and PD. The inner surface of all crowns was superimposed with the master die files by the "Best-fit alignment" method using the analysis software. One-way and 2-way ANOVA were performed to identify significant differences among the groups and areas and their interactive effects (${\alpha}=.05$). Tukey's HSD was used for post-hoc analysis. RESULTS. One-way ANOVA results revealed a significantly higher RMS value in the 3D printed models (DD and PD) than in the CS and DV. The RMS values of PD were the largest among the four groups. Statistically significant differences among groups (P<.001) and between areas (P<.001) were further revealed by 2-way ANOVA. CONCLUSION. Although the fit of crowns fabricated based on the 3D printed models (DD and PD) was inferior to that of crowns prepared with CS and DV, the values of all four groups were within the clinically acceptable range (<$120{\mu}m$).

A Case of Oncocytic Lipoadenoma Arising in the Submandibular Gland (악하선에 발생한 호산성 지방선종 1례)

  • Lee, Bum Sang;Lee, Jong Kyu;Jang, Soo Kyung;Seo, Kang Hyun;Kim, Jin Hwan;Bang, Heejin;Lee, Dong Jin
    • Korean Journal of Head & Neck Oncology
    • /
    • v.35 no.2
    • /
    • pp.35-38
    • /
    • 2019
  • Oncocytic lipoadenoma is a rare salivary gland tumor composed of adipose tissue and oncocytic epithelial cells in varied proportions. We report a case of an oncocytic lipoadenoma of the submandibular gland, which presented as a submandibular gland mass. The patient was a 65-year-old woman with a right submandibular mass measuring 2 × 2 × 1.6 cm. As a sonographic evaluation and computed tomograph scan gave us the impression of benign submandibular gland tumor such as pleomorphic adenoma, we resected the right side submandibular gland. Grossly, the tumor was well circumscribed with yellow to brown cut surface. Microscopically, the tumor was surrounded by a thin, fibrous capsule and composed of oncocytic epithelial cells admixed with mature adipose tissue. Final diagnosis was an oncocytic lipoadenoma. We discussed here radiologic and pathologic finding of this rare salivary gland tumor.

Changes in pre-osteoblast cells associated with non-precious metal cores with dental implants: Pilot test (치과용 임플란트 적용 비귀금속 코어와 관련된 전조골세포의 변화)

  • Park, Jung-Hyun;Kang, Seen-Young;Kim, Jong-Woo;Kim, Jang-Ju;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.40 no.2
    • /
    • pp.63-69
    • /
    • 2018
  • Purpose: The purpose of this study is to investigate the non-precious metal core materials used in the dental laboratory to fabricate the implant superstructure by CAD / CAM method. And to observe and compare the morphology and distribution of the osteoblasts in relation to implant osseointegration. Methods: In this study, the mandibular right first molar tooth model was selected as an international standard to produce a single core. Using this model, the impression was made with the silicone rubber, the tooth model was scanned, and a single core was designed and 5-axis milling was performed. The materials used were Cobalt-Chromium and Nickel-Chromium, and the cores for dental implant top structures were fabricated according to the procedures of the dental labs. After the fabrication, the marginal area of the core was separated and cell culture experiment was performed. The osteoblast cells used MC3T3-E1, which is currently widely used. For morphological analysis of osteoblasts, cells were posttreated and observed using CLSM (Confocal Laser Scanning Microscope) and compared. Results: The cell adhesion behavior of the specimen surface measured by CLSM was uniformly distributed in specimen A (Cobalt-Chromium) than in specimen B (Nickel-Chromium). The distribution and changes of the cells were different in the two specimens. Conclusion : It is possible to confirm that specimen A (Cobalt-Chromium) is suitable for the living body through adhesion and proliferation of osteoblasts related to implant osseointegration in the non-precious metal superstructure used after implantation. It is considered that it is preferable to use Co-Cr when fabricating the superstructure.

COMPARISON OF FRACTURE STRENGTH BETWEEN HYBRID-CERAMIC CROWN AND METAL-CERAMIC CROWN (Hybrid-Ceramic Crown과 금속 도재관의 파절강도 비교)

  • Ku Chul-Whoi;Yang Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.14-24
    • /
    • 2001
  • The purpose of this study was to compare the fracture strengths and the fracture patterns of several hybrid-ceramic crowns and metal-ceramic crown. Ten crowns were constructed for each group according to the manufacturer's instruction. Removable template of silicone rubber impression material was used for standardization of each crowns. Each crown was cemented on a metal die with hybrid glass ionomer cement. All crowns cemented were stored in distilled water, $36^{\circ}C$ for 24 hours prior to loading in an universal testing machine. The load was directed at 130 degrees the long axis of metal die. The fracture strengths were measured and the fracture patterns were observed. The following results were obtained from this study 1. The mean fracture strengths of $Artglass^{(R)}$, $Sculpture^{(R)}$ and $Targis^{(R)}$ were $57.5{\pm}9.5Kgf,\;62.7{\pm}12.2Kgf$ and $60.2{\pm}10.1Kgf$ respectively. There was no significant difference among each hybrid ceramic crown group. 2. The toad required to fracture hybrid-ceramic crowns was significantly smaller than metal-ceramic crowns($131.7{\pm}22.0Kgf$). 3. In the metal-ceramic crowns, labial porcelain detached partially from porcelain-metal junction of proximal side by load. 4. Hybrid-ceramic crowns showed a simple fracture pattern that fracture line began at the loading area and extended through proximal surface, perpendicular to the margin. The crown was separated into two parts of labial side and lingual side. Above results revealed that three kinds of the hybrid-ceramic crowns used in this study must have careful application in clinical use since the strength of hybrid-ceramic crown was lower(about 1/2) than that of metal-ceramic crown.

  • PDF

Geometric Features Detection of 3D Teeth Models using Approximate Curvatures (근사 곡률을 이용한 3차원 치아 모델의 기하학적 특징 검출)

  • Jang, Jin-Ho;Yoo, Kwan-Hee
    • The KIPS Transactions:PartA
    • /
    • v.10A no.2
    • /
    • pp.149-156
    • /
    • 2003
  • In the latest medical world, the attempt of reconstructing anatomical human body system using computer graphics technology awakes people's interests. Actually, this trial has been made in dentistry too. There are a lot of practicable technology fields using computer graphics in dentistry For example, 3D visualization and measurement of dental data, detection of implant location, surface reconstruction for restoring artificial teeth in prostheses and relocation of teeth in orthodontics can be applied. In this paper, we propose methods for definitely detecting the geometric features of teeth such as cusp, ridge, fissure and pit, which have been used as most important characteristics in dental applications. The proposed methods are based on the approximate curvatures that are measured on a 3D tooth model made by scanning an impression. We also give examples of the geometric features detected by using the proposed methods. Comparing to other traditional methods visually, the methods are very useful in detecting more accurate geometric features.

A Case of Aberrant Cervical Thymus in a One-year-old Boy (소아의 이소성 경부흉선 1예)

  • Lee, Seong-Cheol;Yang, Seok-Jin;Kim, Woo-Ki
    • Advances in pediatric surgery
    • /
    • v.2 no.1
    • /
    • pp.64-67
    • /
    • 1996
  • Aberrant migration of thymic tissue occurs as an ectopic thymus in the mediastinum, base of skull, tracheal bifurcation, and cervical region. A recent review of the literature by Nowak et al. showed over 70 reported cases of aberrant thymus or thymic cyst in patients who presented with primary neck masses. Authors experienced a case of ectopic cervical thymus and reviewed the literature. A one-year-old boy with left neck swelling which had been noticed since one month of age visited out patient clinic. Ultrasonography showed a well-defined cystic mass containing homogeneous, low-echogenic content locating in the lateral aspect of the left carotid sheath. Operation was performed under the impression of branchial cleft cyst. At surgery, a multiseptated, well-encapsulated, brownish and doughy mass which was extending into the vicinity of the carotid bifurcation with sland stalk-like portion ending between the hypoglossal nerve and external carotid artery was excised completely. The cut-surface showed homogenous solid mass, and on frozen section the tissue revealed a normal thymic histology. Postoperative ultrasonography showed bilateral thymus in the superior mediastinum. The patient has no immunologic problem and is doing well now.

  • PDF

Acquired Dermoid Cysts within Subcutaneous Scar Tissue (피하 흉터 조직에서 발견된 후천성 유피낭종)

  • Kim, Hyoung Jin;Burm, Jin Sik;Pyon, Jai Kyong;Kim, Yang Woo
    • Archives of Plastic Surgery
    • /
    • v.34 no.4
    • /
    • pp.508-511
    • /
    • 2007
  • Purpose: Dermoid cysts are almost always caused by congenital events. The most widely accepted pathogenesis is that the cysts are dysembryogenetic lesions that arise from ectodermic elements entrapped during the midline fusion. We report a rare case of dermoid cyst, which occurred not congenitally but newly in the subcutaneous scar tissue secondary to trauma. Methods: A 26-year-old man had a deep submental laceration caused by a car accident and got a primary wound closure 16 months ago. There were 18 cm-long submental hypertrophic scar and newly developed palpable masses inside the subcutaneous layer at the center of the scar. Initial impression was an epidermal cyst or a thyroglossal duct cyst. Ultrasonographic finding showed two cystic masses inside the scars at the submental area, but impressed dermoid cysts. The cystic masses were completely removed with W-plasty and histological examination were followed. Results: The histological diagnosis was dermoid cysts which were mainly composed of keratotic squamous epithelium in their inner surface linings and numerous skin appendages such as sebaceous glands, sweat glands, and hair follicles in their cystic lumens histopathologically. During the follow-up period of 25 months, there was no recurrence of any subcutaneous mass in the site of scar. Conclusion: We report a very unusual case of dermoid cysts developed by an acquired cause, considering that the accidental inclusion of deep skin elements caused by a trauma can be a critical origin of dermoid cysts.

3D quantitative analysis and SEM qualitative analysis of natural antagonist enamel opposing CAD-CAM monolithic zirconia or lithium disilicate tooth-supported crowns versus enamel opposing natural enamel

  • Piyarat Woraganjanaboon;Chuchai Anunmana
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.1
    • /
    • pp.12-24
    • /
    • 2024
  • PURPOSE. This study aimed to evaluate the maximum vertical wear, volume wear, and surface characteristic of antagonist enamel, opposing monolithic zirconia or lithium disilicate crowns. MATERIALS AND METHODS. The study comprised 24 participants (n = 12), who were randomly allocated to receive either a 5 mol% Y-TZP or a lithium disilicate crown in positions which would oppose the natural first molar tooth. The contralateral first molar along with its antagonist was considered as the enamel opposing natural enamel control. Data collection was performed using an intraoral scanner and polyvinylsiloxane impression. The means of the maximum vertical loss and the volume loss at the occlusal contact areas of the crowns and the various natural antagonists were measured by 3D comparison software. A scanning electron microscope was subsequently used to assess the wear characteristics. RESULTS. The one-year results from 22 participants (n = 11) indicated no significant differences when comparing the zirconia crown's antagonist enamel (40.28 ± 9.11 ㎛, 0.04 ± 0.02 mm3) and the natural enamel wear (38.91 ± 7.09 ㎛, 0.04 ± 0.02 mm3) (P > .05). Also, there is no significant differences between lithium disilicate crown's antagonist enamel (47.81 ± 9.41 ㎛, 0.04 ± 0.02 mm3) and the natural enamel wear (39.11 ± 7.90 ㎛, 0.04 ± 0.02 mm3) (P > .05). CONCLUSION. While some studies suggested that monolithic zirconia caused less wear on opposing enamel than lithium disilicate, this study found similar wear levels to enamel for both materials compared to natural teeth.