• Title/Summary/Keyword: Impression materials

Search Result 310, Processing Time 0.025 seconds

A STUDY ON DIMENSIONAL STABILITY OF THE RUBBER IMPRESSION MATERIALS FOLLOWING IMMERSION WITH CHEMICAL DISINFECTANTS (수종의 화학소독제에 침적시킨 고무인상체의 크기안정성에 관한 연구)

  • Kim, Hyung-Sik;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.249-259
    • /
    • 1989
  • Dental impression materials often become contaminated with patients' saliva and blood which creates the potential for cross-infection. It was the purpose of this study to investigate the effects of disinfection of three different rubber impression materials with four different disinfecting solutions. Polysulfide, vinyl polysiloxane and polyether impression materials were mixed according to the manufacturer's directions and samples were formed on a stainless steel model. On removal from the standard model, impressions were immersed in a disinfectant (acid-potentiated glutaraldehyde, phenollic compound, chlorine compound, iodophor) at room tempera tures for ten minutes. After disinfection, the distance between reference points(linear dimension) was measured using the non-contact automatic cordinate measuring projector(MZ-1, Nikon). Through statistical analyses on the data from this study,. the following conclusions were obtained. 1. Polysulfide, vinyl polysiloxane impressions were disinfected without dimensional change.(p>0.05) 2. Polyether impressions which were immersed in acid-potentiated glutaraldehyde were statistically different from control group.(p<0.05) But the amount of shrinkage(0.04%) would not be clinically significant. 3. By immersion of polysulfide, vinyl polysiloxane, polyether impressions in Banicide, Biocide, Multicide plus, sodium hypochlorite for ten minutes, clinically accurate impressions were obtained without dimensional change.

  • PDF

THE EFFECT OF IMMERSION DISINFECTION ON THE DIMENSIONAL STABILITY OF RUBBER IMPRESSION MATERIALS (침적 소독이 고무 인상재의 크기 안정성에 미치는 영향)

  • Min, Geun-Nam;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.3
    • /
    • pp.496-505
    • /
    • 1998
  • The purpose of this study was to evalute the effect of immersion disinfection on the dimensional stability of rubber impression materials. The metallic master model was made in order to simulate the intraoral arch form. Impressions were made from four impression materials (Exaflex, Extrude, Reprosil, Impregum-F) and immersed in three disinfectant solutions (Wydex, Vi-Pon, Potadine). Casts from the impressions were measured according to the interpreparation distance. The A-B and The B-D abutment distance were compared with the control group and disinfected groups. The results were as follows; 1. The measurements of the stone cast increased relative to the master model and there was a significant difference (P<0.05). 2. The relative dimensional change of the stone cast as compared with master model ranged from 0.10% to 0.56% in the A-B distance and ranged from 0.04% to 0.27% in the B-D distance. 3. The dimensional change of the disinfected groups as compared with the control group was significantly different in the three impression materials except for Impregum-F (P<0.05). 4. The relative dimensional change of the disinfected groups compared with the control group ranged from 0% to 0.20% in the A-B distance and ranged from -0.09% to 0.11% in the B-D distance. These results suggest that immersion disinfection of rubber impression materials by chemical disinfectants causes very small dimensional change and the change is clinically acceptable for prothesis fabrication

  • PDF

신개발 국산 부가중합 실리콘 인상재의 젖음성과 기포발생에 관한 비교 연구

  • 조리라;정경호;김경남
    • The Journal of the Korean dental association
    • /
    • v.41 no.1 s.404
    • /
    • pp.35-41
    • /
    • 2003
  • Wettability of addition silicone impression material is very important property for making an accurate restoration. This study examined theimpression quality in clinical condition and the wettability of impression material. Three commercially available addition silicone impression material (Imprint; 3M, USA, Examix; GC, Japan, Perfect; Handae, Korea) were studied. A total of 90 putty/wash impressions of semi-dried premolars and wet molar teeth were examined for void production in impression body. The percentae of the sulcus reproduction ability of each material was calculated from the sulcus depths of cross-sectioned casts from the impressions with stereomicroscope. Three impression materials were used to produce die stone casts from vcid entrapment die. Voids in the stone casts were counted with the stereomicroscpe. From the experiment, the following results were obtained: 1. In direct observation, Imprint showed greatest numbers of void in impression body (P<.001).However, correlations were not found between sulcus reproduction and void production. 2. Sulcus reproduction ability of additional silicone impression material was diminished in order of Imprint, Examix, Perfect. The significant difference was found between Imprint and other material (P<.001). 3. In void entrapment laboratory test, void productions was diminished in order of Examix, Imprint, Perfect. All voids in casts were less in delayed poured cast than immediately poured cast. 4. Especially, the stone pouring time of Perfect impression material should be delayed.

  • PDF

Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique

  • Pastoret, Marie-Helene;Krastl, Gabriel;Buhler, Julia;Weiger, Roland;Zitzmann, Nicola Ursula
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.287-293
    • /
    • 2017
  • PURPOSE. To compare the dimensional accuracy of three impression techniques- a separating foil impression, a custom tray impression, and a stock tray impression. MATERIALS AND METHODS. A machined mandibular complete-arch metal model with special modifications served as a master cast. Three different impression techniques (n = 6 in each group) were performed with addition-cured silicon materials: i) putty-wash technique with a prefabricated metal tray (MET) using putty and regular body, ii) single-phase impression with custom tray (CUS) using regular body material, and iii) two-stage technique with stock metal tray (SEP) using putty with a separating foil and regular body material. All impressions were poured with epoxy resin. Six different distances (four intra-abutment and two inter-abutment distances) were gauged on the metal master model and on the casts with a microscope in combination with calibrated measuring software. The differences of the evaluated distances between the reference and the three test groups were calculated and expressed as mean (${\pm}SD$). Additionally, the 95% confidence intervals were calculated and significant differences between the experimental groups were assumed when confidence intervals did not overlap. RESULTS. Dimensional changes compared to reference values varied between -74.01 and $32.57{\mu}m$ (MET), -78.86 and 30.84 (CUS), and between -92.20 and 30.98 (SEP). For the intra-abutment distances, no significant differences among the experimental groups were detected. CUS showed a significantly higher dimensional accuracy for the inter-abutment distances with -0.02 and -0.08 percentage deviation compared to MET and SEP. CONCLUSION. The separation foil technique is a simple alternative to the custom tray technique for single tooth restorations, while limitations may exist for extended restorations with multiple abutment teeth.

A STUDY ON THE CONTACT ANGLE AND WETTABILITY OF THE DENTAL STONES (수종 치과용 석고의 접촉각 및 젖음성에 관한 비교 연구)

  • Cho Lee-Ra;Chung Kyung-Ho;Kim Kyoung-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.1
    • /
    • pp.61-70
    • /
    • 2003
  • The purpose of this study was to investigate the contact angles and wettability of conventional dental stones and improved dental stones and newly developed dental stones on several impression materials. Materials included in this study were several dental stones and newly developed dental stone ; 2 type III stones (Snow Rock, New Diastone), 6 type IV stones(Crystal Rock, Vel Mix, Fuji Rock, Tuff Rock, Resin Rock and newly developed dental stone) and 1 type V stone (Die Keen). Contact angles on the impression materials were measured with contact angle measuring device. Ten specimens for each material, total 180 specimens were made on void entrapment model. The two impression materials (Handae, GC) were used to produce 9 groups of die stone casts form void entrapment model. Voids in the stone casts were counted under a stereoscopic microscope. The grad for the reproduction ability of each materials on the void entrapment model was calculated from the casts by one examiner. From the experiment, the following results were obtained : 1. The newly developed stones showed smallest contact angle. Type III dental stone had larger contact angles than type IV and V stones. Contact angle was much affected by the impression materials. 2. Resin containing die materials such as Tuff Rock and Resin Rock had smallest void number than any other groups. 3. In comparing reproduction parameters, Tuff Rock and Resin Rock presented superior results, while Vel Mix showed lowest reproduction ability.

Synergy Effect of Chlorhexidine and Essential Oils on Antimicrobial Activity in Dental Impression Materials (치과용 인상재에서의 클로르헥시딘과 에센셜 오일의 항균성능에 대한 상승효과)

  • Lee, Kwang-Rae
    • Korean Chemical Engineering Research
    • /
    • v.56 no.2
    • /
    • pp.240-244
    • /
    • 2018
  • There is growing concern about cross infection among the patients to patients, patients to staffs, and tools to patients in healthcare facilities, especially in dentistry. In this study, the most widely used dental impression materials were prepared and the synergy effect of Chlorhexidine and essential oil on antimicrobial activity was examined in the impression materials. Chlorhexidine concentration of 0.1 wt% and 0.5 wt% showed no antimicrobial activity on Escherichia coli (E. coli) and Candida albicans. At 1.0 wt% Chlorhexidine, 0% of E. coli and 34.7% of Candida albicans were survived. Bergamot (Essential oil) concentration of 0.5 wt% and 1.0 wt% showed no antimicrobial activity on E. coli. At 2.0 wt% Bergamot oil, 71.9% of E. coli were survived. Tea tree oil (Essential oil) of 0.5 wt% showed no antimicrobial activity on E. coli. At 1.0 wt% Tea tree oil, 11.2% of E. coli was survived. At 2.0 wt% Tea tree oil, no E. coli was survived. However, no E. coli was survived at the concentration of 0.8 wt% Bergamot with 0.3 wt% Chlorhexidine. At the concentration of 0.8 wt% Tea Tree oil with 0.3 wt% Chlorhexidine, 1.3% of E. coli were survived. The experimental results showed that the synergy effects between Chlorhexidine and essential oils on antimicrobial activity were prominent.

A Study on Mosaic Pattern in Modern Costume (현대복식에 나타난 모자이크풍 패턴에 관한 연구)

  • 남윤숙;김복희
    • Journal of the Korean Society of Costume
    • /
    • v.51 no.2
    • /
    • pp.43-52
    • /
    • 2001
  • The purpose of this research is to study the aesthetic character of a mosaic which is expressed in the Modern Costume. The methods of the research were by literature and it was mainly done with reference to master's theses, doctor's theses, separate volumes, periodicals, domestic and overseas fashion magazines and internet on the subject. The result of the research appears as rhythm, exoticism, abstraction, mystery, recreation by disintegration. First, rhythm appears in a sense of free rhythm with the method of arranging motives and the kinds of materials varying. Second, exoticism gives impression with such motives as Oriental designs, African designs and the geometric designs of nature occupying the surface. Third, abstraction displays motives such as unrealistic fashion. Fourth, mystery gives a cyber-related impression with the help of such scientific materials as fluorescent plastics, metal and glass. Fifth, recreation pelves an aesthetic impression by reorganizing the costume with the disintegration and transformation of Industrial materials such as plastics, metal and glass, etc. based on their unique colors and quality.

  • PDF

Comparative study on properties of commercial polyvinyl siloxane impression materials (시판 폴리비닐실록산 인상재의 물성에 관한 비교연구)

  • Kang, Jae-Kyoung
    • Journal of Korean society of Dental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.171-180
    • /
    • 2001
  • The purpose of this study was to compared with the properties of commercial polyvinyl siloxane impression materials on the Korean product and the other country one. The materials used in this study were 5 hydrophilic polvinyly siloxane impression materials of light body automixing type (Perfect-F, Handae Chemical, Korea; Examix, GC, Japan; Contrast, VOCO, Germany; Express, 3M, U.S.A; Extrude, Kerr, U.S.A.). Specimens of each impression material were fabricated from a mold with dimensions identical to that specified in ASTM D624-91 and were subjected to tensile lode at 500 mm/min until failure for tear strength. Properties of consistency, strain in compression, recovery from deformation, detail reproduction and linear dimensional change were tested according to the testing methods of the ISO specification no.4823(1992). From this study, the follow ing results were obtained 1. The tear strength values were high ET(3.4kN/m), EP(3.4kN/m), PF(3.0kN/m), CT(3.0kN/m), but the lowest was EM(2.2kN/m)(p<0.05). 2. In the consistency, CT(47 mm) had the highest value, followed by PF(42.1 mm), ET(41.2 mm), and EM(39.6 mm), EP(39.2 mm)(p<0.05). It means more flow that the consistency value is high. 3. The strain in compression values were high followed by EM(5.8%), PF(52%), CT(4.6%), ET(4.1%), EP(2.9%)(p<0.05). 4. In the recovery from deformation, ET(99.95%) and PF(99.90%) had the highest value, followed by EP(99.75%), EM(99.74%) without statistical signification, CT(99.64%) had the lowest value(p<0.05). 5. Detail reproduction reappeared to line $20{\mu}m$ all products. 6. The linear dimensional change was a little shrinked all products. and there were not statistical signification (p>0.05). All products were satisfied the ISO specification.

  • PDF