• Title/Summary/Keyword: Impression material

Search Result 202, Processing Time 0.02 seconds

THE EFFORT OF VARIOUS MIXING METHODS ON DYNAMIC VISCOELASTICITY OF A TEMPORARY SOFT LINING MATERIAL; COE-COMFORT

  • Ryu Hyun-Ju;Bae Hanna-Eun-Kyong;Shim June-Sung;Lee Seok-Hyung;Moon Hong-Suk;Chung Mun-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.641-646
    • /
    • 2004
  • Statement of Problem. Temporary soft relining materials are used in a diverse clinical situations such as tissue conditioner, relining material, functional impression by varying its viscoelasticity. However, reproduction of consistent viscoelasticity has been not possible. Materials and methods. Considering setting mechanism of this material, this study has measured the effect of varying amount of void in dynamic viscoelasticity of soft relining material, with three different mixing methods. In each methods 10 specimens were made and subjected to dynamic viscoelastic test which were measured at specific times over period of 72 hours. Results. The analysis of the result shown that there was no statistically significant differences between different mixing methods. Conclusion. Different mixing methods had no effect over control of viscoelasticity of soft lining material. Further research is recommended for under similar oral environmental condition.

ADHESIVE PROPERTY OF POLYSULFIDE IMPRESS10N MATERIAL ON THE TRAY RESIN AND BORDER HOLDING MATERIALS (타액오염이 트레이 레진 및 변연 형성재와 Polysulfide 인상재의 접착력에 미치는 영향)

  • Kim, Yong-Hak;Yang, Hong-Seo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.650-658
    • /
    • 2000
  • This study was investigated to compare the bond strength of polysulfide adhesive between tray resin and border molding materials and to evaluate the effect of saliva contamination on them. We made the 135 resin tray secimens with a dimension of $1{\times}1{\times}1cm$ and divided them into 3 groups by the materials 1) Quicky group, 2) Compound group, and 3) Impregum group Each group was subdivided by saliva contimination. Group S1 : applied adhesive without saliva contamination Group S2 : applied adhesive after drying 15seconds after saliva contamination Group S3 : applied adhesive no after saliva contamination. Tensile tests were performed with a Universal Load testing machine. Results showed Impregum group significantly higher bond strength than Quicky group, but there was no significant difference in adhesive bond strength between Compound group and Quicky group in experimental group by materials In experimental group by saliva contamination, S1 group is significantly higher bond strength than S2 group and S2 group is significantly higher bond strength than S3 group in Quicky group and S1, S2 group is significantly higher bond strength than S3 group in Compound group and Impregum group. Impression compound and Impregum F which are usually used as an individual tray border mold-ing material can be said to be satisfied in adhesive bond strength to polysulfide impression materials. After try-in and clinical adjustment are performed, a custom tray should be properly rinsed and air dried before tray adhesive was placed.

  • PDF

A Study on the Physical Properties of Addition Silicone Impression Materials (부가중합형실리콘인상재의 물리적 특성에 대한 연구)

  • Kim, Soo-Hwa
    • Journal of dental hygiene science
    • /
    • v.6 no.4
    • /
    • pp.231-235
    • /
    • 2006
  • This study evaluated the properties of polyvinylsiloxane impression materials: Strain-in-compression, Elastic recovery, Consistency, and Wettability. Four polyvinylsiloxane impression materials(Examixfine, GC, Japan; Aquasilultra, Dentsply, USA; Extrude, Kerr, USA; Perfect-F, Handae, Korea) were used in this study. The measured data were analyzed with SPSSWIN 12.0 program. The results were as follows : 1. The strain-in-compression values showed that Extrude had the lowest value, 4.86% and Examixfine had the highest value, 6.78%. Significant difference between Examixfine and Perfect-F was not found but the other groups had significant differences(p = 0.000). 2. In the elastic recovery test, Extrude had the highest, 99.83% and Perfect-F had the lowest, 96.54%. There is no significant difference between Examixfine and Aquasilultra. The other impression material groups showed significant differences(p = 0.000). 3. The measurement of consistency results that the diameter of Examixfine was the largest, 45.12mm and one of Perfect-F was the smallest, 40.28 mm. No differences were shown between Examixfine and Aquasilultra and between Extrude and Perfect-F(p = 0.001). 4. Aquasilultra had a better hydrophilicity($47.85^{\circ}$) than other materials. Perfect-F had a larger contact angle($94.89^{\circ}$) and was hydrophobic. There were significant differences between groups(p = 0.000). 5. As for correlation among the test types, contact angle correlated with strain-in-compression, elstic recovery and consistency. The strain-in-compression had correlation to contact angle and elastic recovery. The elastic recovery correlated with contact angle and strain-in-compression. And the consistency had correlation to contact angle.

  • PDF

THREE-DIMENSIONAL ANALYSIS OF THE NORMAL DENTITION AND EDENTULOUS MAXILLA OF KOREANS (한국인의 상악 유치악 치열 및 무치악 치조제에 관한 삼차원적 연구)

  • Kim Hyeong-Seop;Shin Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.191-203
    • /
    • 2005
  • Statement of problem. In Korea, the preliminary impression trays for dental and edentulous maxillae are manufactured on the base of the statistical value of Westerners. There had been less study on the dental and edentulous arches of Koreans. Purpose. The purpose of this study was to evaluate an average dental cast, preliminary impression trays, three-dimensional relation of dental and edentulous maxilla of Koreans Material and methods. The subjects for this study were 173 dental casts of maxilla (dental: 52, edentulous : 146) with ages $18\{\sim}60$ years old. Each of the master casts was measured 69 measuring points on the dental cast or maxilla, and 46 measuring points on the edentulous cast of maxilla with three-dimensional digital measuring machine. Each measuring points were analysed and were overlapped, that three dimensional dental graphic manufactured by CAD/CAM system. Results. 1. A standard of distribution to alveolar bone were width between left and right buccal border lines of the standard 3/4 line. The mean value of dental and edentulous casts were 67.27mm, 63.49mm respectively. 2. Morphological classification of dental casts were divided into three groups or V-shape, O-shape, U-shape, that proportion of distribution were 17%, 16%, 67%, respectively. Dimensional classification of the dental casts were divided into five groups of less than 63mm, 63 up to 65mm, 65 up to 67mm. 67 up to 69mm, more than 69mm, respectively. 3. Morphological classification of edentulous casts were divided into three groups or V-shape, O-shape, U-shape, that proportion of distribution were 18%, 17%, 65%, respectively Dimensional classification of the edentulous casts were divided into five groups of less than 57mm, 57 up to 61mm, 61 up to 65mm, 65 up to 69mm, more than 69mm, respectively. 4. Mean dental and edentulous cast of maxilla were overlapped, the proportion of bone resorption to alveolar bone is higher than that of palatal bone, its difference were higher anterior 2/4 area than posterior 3/4 area. Conclusion. It obtains information of preliminary impression trays for dental and edentulous maxilla of Koreans.

Changes of the surface roughness depending on immersion time and powder/liquid ratio of various tissue conditioners (수종의 조직 양화재의 침수시간과 분액비에 따른 표면 거칠기의 변화)

  • Kim, Kyung-Soo;Moon, Hong-Suk;Shim, June-Sung;Jung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.108-118
    • /
    • 2009
  • Statement of problem: Volume stability, microstructure reproducibility and fluidity along with compatibility with dental stone must be in consideration in order to use tissue conditioner as a material for functional impression. There are few studies concerning the influence of time factor in oral condition on surface roughness of the stone and optimal retention period in the oral cavity considering such changes in surface roughness. Purpose: The purpose of this study was to find out the influence of various kinds of tissue conditioner, its powder/liquid ratio and immersion time on surface roughness of the stone. Material and methods: Materials used in this study were the three kinds of tissue conditioners(Coe-Comfort, Visco-Gel, Soft-Liner) and were grouped into three: group R-mixed with standard powder/liquid ratio that was recommended by the manufacturers, group M-mixed with 20% more powder, group L-mixed with 20% less powder. Specimens were made with the size of 20 mm diameter and 2 mm width. Each tissue conditioner specimens were subdivided into 5 groups according to the immersion time(0 hour, 1 day, 3 days, 5 days, 7 days), completely immersed into artificial saliva and were stored under $37^{\circ}C$. Specimens of which the given immersion time elapsed were taken out and were poured with improved stone, making the stone specimens. Surface roughness of the stone specimens was measured by a profilometer. Results: Within the limitation of this study, the following results were drawn. 1. Major influencing factor on surface roughness of the stone model made from tissue conditioner was the retention period(contribution ratio($\rho$)=62.86%, P<.05) of the tissue conditioner in oral cavity to make functional impression. 2. In case of Coe-Comfort, higher mean surface roughness value of the stone model with statistical significance was observed compared to that of Soft-Liner and Visco-Gel as immersion time changes(P<.05). 3. In case of group L(less), higher mean surface roughness value of the stone model with statistical significance was observed compared to that of R(recommended) and M(more) group as immersion time changes(P<.05). Conclusion: We may conclude that as the retention period of time in oral cavity influences surface roughness of the stone model the most and as the kind of tissue conditioner and its P/L ratio may influence also, clinician should well understand the optimal retention period in oral cavity and choose the right tissue conditioner for the functional impression, thus making the functional impression with tissue conditioner usefully.

A Study on the Preference of Design Components of Shop Facade (숍 파사드 디자인 구성요소에 대한 선호도 연구)

  • Yeo, Mi;Oh, Sun Ae
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.2
    • /
    • pp.171-179
    • /
    • 2015
  • The aim of this study is to figure out the preference features on design components of shop facade on the basis of the questionnaire survey on short-term memory and sensory memory of human right after an image experiment. As for a preceding research, this study examined the design features of facade into tangible elements and intangible elements, and also classified them into physical, aesthetical, marketing and symbolic components in detail. And, it extracted 5 representative elements in preceding studies including shape, material, pattern, color and sign, which is the standard of a questionnaire survey and preference analysis. The subjects of the experiment were 30 men and women who were over 20 years old majoring interior design. They were exposed to 20 images with 10 seconds respectively through a video, and were asked to respond the questionnaire promptly. The findings of preference analysis of design components of facade including shape, material, pattern, color and sign are as follows. Firstly, shape was the most interesting and attracting component, and designs applied with shape of objects such as 'web', 'drawer', 'wheel' and 'button' obtained high preference. Secondly, as for material, block, steel, exposed concrete board attracted higher preference as memorable materials than other materials. Material was affected by shape, pattern and color. Thirdly, pattern was the most lasting element. Designed pattern had higher preference than simple pattern. Fourthly, as for color, red and green with strong stimulation and attention attained priority having long lasting memory. Fifthly, when visiting a shop, sign out of 5 elements of shape, material, pattern, color and sign drew attention the most. As for the preference of location of sign, 'center top' was the most noticeable. The findings of this study could be utilized for facade design, and also could be used for commercialization considering highly preferred components, and top preference aspects of such elements. advised that to give an impression to customers is important to make a successful design for sales marketing, which, in turn, would lead customers to revisit the shop.

Pontic site development and soft tissue transfer of the esthetic area: a case report (심미적 부위에서 가공치 하방 잔존치조제의 형성 및 연조직 복제 모형을 이용한 고정성 보철물 수복증례)

  • Kim, Hak-Cheon;Noh, Kwantae;Kwon, Kung-Rock;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.323-331
    • /
    • 2013
  • Soft tissue collapse around prepared teeth and pontic is inevitable after removal of the provisional restoration during the impression taking procedures. When inserting gingival retraction cord, soft tissue is displaced to an undesired contour. Viscosity of impression material also causes gingival displacement. Therefore, the consideration to transfer the prosthetically contoured soft tissue to master cast is required, especially in the esthetic area. In this report, the methods to maintain the soft tissue contour and transfer to the mastercast will be introduced. Harmonious contour of the soft tissue can be achieved with provisional restoration and be transferred to the master cast with two different techniques mentioned in this case report.

The Characteristics of Exhaust Gas in Diesel Engine by Corana Discharge-EGR System (코로나 방전-EGR 조합시스템에 의한 디젤기관의 배기 가스 특성)

  • Park, Jae-Yoon;Jung, Jang-Gun;Kim, Jong-Suk;Ha, Hyun-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.39-44
    • /
    • 2005
  • A great part of flint fuel is Hydrogen and carbon's combination, they should be generated steam and carbon gas when combine with oxygen for perfect combustion in the inside of engine but, the pollutive material are discharged, even though perfect combustion condition especially $NO_x$ and Smoke. they are really harmful for health. In this paper was shown the result of discharging gas' reduction quality. which used combination of corona discharge using the high voltage source of common frequency with EGR. $NO_x$ is increased in entire load erea in proportion to increasing of EGR rate and impression voltage. Smoke is increased slowly under 75[%] in load rate but it is increased rapidly in entire load erea and the reduction rate of Smoke is increased in proportion to increasing of impression voltage.

The relationship of maxillary canines to the facial anatomical landmarks in a group of Thai people

  • Sinavarat, Potchaman;Anunmana, Chuchai;Hossain, Sharafat
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.369-373
    • /
    • 2013
  • PURPOSE. The objective was to evaluate canine positions, intercanine tip width (ICTW) and width of distal surface of canine (WDC), related to facial landmarks including interalar width (IAW), intercommissural width (ICoW), and distance between left and right projection lines drawn from inner canthus of eyes to alae of the nose (DPICa) in a group of Thai. MATERIALS AND METHODS. One hundred Thai subjects aged 18-35 years were selected. IAW and ICoW were measured on subject's face using digital vernier caliper. Irreversible hydrocolloid impression of the upper arch was taken, and a cast was poured with dental stone. Silicone impression material was used to take imprint of the incisal edge of upper six anterior teeth. DPICa was obtained from the subject's face using custom-made measuring equipment and marked on the silicone incisal imprint. The marks were then transferred from the imprint to the stone cast and measured with digital caliper. The ICTW and WDC were also measured on the stone cast. Pearson's correlation was used to determine the correlation. RESULTS. The results revealed that the correlation between ICTW-ICoW was 0.429 and ICTW-DPICa was 0.573. The correlation between WDC-ICoW was 0.426 and WDC-DPICa was 0.547. However, IAW did not show any correlation with ICTW or WDC (P>.05). CONCLUSION. The correlation between canine position and facial landmarks was found. ICTW and WDC had relationship with ICoW and DPICa. DPICa showed stronger correlation with the position of maxillary canine than that of ICoW.

DIMENSIONAL CHANGE AND FLEXURAL STRENGTH IN COMPLETE DENTURES FABRICATED BY INJECTION MOLDING AND CONVENTIONAL COMPRESSION PROCESSING (의치상용 레진의 전입 방법에 따른 중합체적변화와 굴곡강도에 관한 연구)

  • Choi Hoon-Dal;Kwon Kung-Rock;Kim Hyeong-Seob;Choi Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.478-486
    • /
    • 2005
  • Statement of problem : Fracture and dimensional change of an acrylic resin denture are a rather common occurrence. Purpose : The purpose of this study was to compare differences in dimensional changes and flexural strength of separate maxillary complete dentures after immediate deflasking by injection molding and conventional compression processing. Material and method: To evaluate dimensional stability, the maxillary dentures were fabricated by using different materials and methods. Lucitone 199(Dentsply Trubyte. york, pennsylvania, USA) and Vertex(Dentimex, zeist, Netherlands) were used as materials. Compression and injection packing methods were used as processing methods. The impression surface of the dentures was measured by 3D Scann-ing System(PERCEPTRON USA) and overlapped original impression surface of the master cast. To evaluate flexural strength, resin specimens were made according to the different materials, powder/liquid ratio and processing methods. Flexural strength of the complete resin specimens (64mm$\times$10mm$\times$3.3mm) were measured by INSTRON 4467. (INSTRON, England) The data was analyzed by ANOVA, t-test and Tukey test. (p<.05 level of significance) Result: The results were as follows 1. There was no significant differences between master model and denture base for each group in overall dimensional changes. 2. Palatal area was more stable than flange or alveolar area in dimensional stability. but. there was no significant differences among each area. 3. Materials and power/liquid ratio had an effect on flexural strength. (P<.05) Especially materials was most effective. (P<.05) 4. Lucitone 199(powder/liquid ratio followed by manufacturer's direction) showed higher flexural strength than Vertex. Conclusion : Dimensional stability or flexural strength are affected by materials rather than packing techniques.