• Title/Summary/Keyword: Implementation Status

Search Result 1,179, Processing Time 0.036 seconds

A Study on Analysis of the Implementation Status and the Advancement of Computerized Maintenance Management System (CMMS) in Korean Companies (한국기업의 설비관리정보시스템(CMMS) 구현실태 분석과 고도화에 관한 연구)

  • Ku, Sung Tae;Kim, Chang Eun
    • Journal of Korean Society for Quality Management
    • /
    • v.41 no.4
    • /
    • pp.693-708
    • /
    • 2013
  • Purpose: This study is to develop an evaluation model for analysis of CMMS Implementation status and provide CMMS advancement methods to maximize implementation effect through the evaluation model. Methods: After extracting common modules from CMMS packages and establishing evaluation standard for each module, then the evaluation standard is applied to 33 Korean companies for evaluating their own current implementation status. Results: Preventive maintenance and analysis information modules were considered the most vulnerable in Korean companies which have introduced CMMS packages. And the reason why preventive maintenance is vulnerable is that there is poor build-up of their own preventive maintenance standards. Conclusion: Korean companies which will introduce CMMS need to make preventive maintenance standards, and data of the materials and the equipment to improve the effectiveness in advance.

Research on Environmental Design Implementation in Taiwan's Manufacturers Certified by ISO 14001

  • Chung, Yi-Chan;Tsai, Chih-Hung
    • International Journal of Quality Innovation
    • /
    • v.7 no.1
    • /
    • pp.177-194
    • /
    • 2006
  • This research investigates the status of environmental design implementation in Taiwan's industries (Certified by ISO 14001) by employing questionnaire survey. The correlation between the degree of environmental design implementation in Taiwan's industries and the relevant entrepreneurial characteristics are examined. Twenty-six environmental design principles in four phases: design, manufacturing, sales and transportation, and disposal are used to define and assess the current status of environmental design. The data analysis methods applied to this research includes descriptive statistics, T-test, Chi-square test, and single-factor analysis of variance (ANOVA). It is evident that 21 out of the 26 environmental design principles are frequently and consistently employed by the manufacturers in Taiwan. The results indicate that environmental design implementation is becoming mature in Taiwan's industries.

Survey of Hospital Information Systems and e-Hospital Strategy of Large-sized Hospitals (국내 대형 병원 정보화 현황 조사 및 e-Hospital 전략)

  • Kim, Dong-Su;Park, Ha-Yeong
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2004.05a
    • /
    • pp.552-555
    • /
    • 2004
  • IT investments of hospitals are growing exponentially and various information systems such as OCS (Order Communication System), EMR (Electronic Medical Record), PACS (Picture Archiving and Communication System), ERP (Enterprise Resource Planning) have been implemented at a number of hospitals in Korea. We have surveyed and analyzed the current status of hospital information systems of major hospitals in Korea, and proposed an information strategy for e-Hospital implementation. Firstly, implementation status of major subsystems of HIS such as OCS, PACS, and EMR has been surveyed and types of IT personnel management have been examined. Based on the field survey result, an information strategy for e-Hospital implementation has been proposed, that can be referenced by hospitals to build their own information strategy. We expect that the study result can contribute to understanding the present status and issues of HIS and information strategy planning of hospitals.

  • PDF

Implementation Status and Related Factors of Health Promoting Schools among Elementary, Middle and High Schools: Based on the WHO Guidelines (초등학교와 중.고등학교 건강증진학교 수행 현황과 관련 요인: WHO 건강증진학교 지표를 중심으로)

  • Lee, Eun-Young;Park, Kyung-Ok;Shin, Young-Jeon;Choi, Bo-Youl
    • Korean Journal of Health Education and Promotion
    • /
    • v.29 no.1
    • /
    • pp.109-120
    • /
    • 2012
  • Objectives: The objectives of this study were to assess the implementation status of Health Promoting Schools (HPS) among elementary, middle and high schools and to identify characteristics of the schools that affect the implementation of HPS. Methods: A total of 703 teachers (male 32.2%, females 67.8%) from 70 elementary, middle and high schools in Seoul and Gyeonggi participated in the survey. A 60-item self-evaluation questionnaire was used to assess implementation status of HPS. Results: Implementation of HPS in elementary schools were more favorable than middle and high schools after controling for participants' characteristics, such as age, gender, and their duties at school (<0.001). Being a private school was associated with higher score on implementation of HPS in both elementary (${\beta}$=0.170) and middle/high schools (${\beta}$=0.275). However, being located in rural areas (${\beta}$=-0.409) and having larger number of students (${\beta}$=-0.521) were associated with lower score on implementation of HPS in middle/high schools. Conclusions: Middle and high schools, especially large public and/or rural schools, were less favorable in implementing HPS. Therefore, supporting those schools are necessary and developing evaluation and monitoring system for HPS implementation will contribute to promote students' health.

A study on the implementation of a CATV status monitoring system using HDLC protocol (HDLC 프로토콜을 채용한 CATV 망감시 시스템 구현에 관한 연구)

  • 김내진;김진태;박인갑
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.10
    • /
    • pp.10-20
    • /
    • 1994
  • This paper presents a CATV SMS (Status Monitoring System) using HDLC (High Level Data Link Contorl) protocol and the system implementation.The system specifications were derived from the analysis of technical status and requirement of the domestic CATV industry. For the interoperability with a global network management system in the future, HDLC protocol was adopted in the system. The system performance was improved by using the communication controller chip and the large data buffer. For reducting the communication problems induced by accumulated noise in up-stream data channels, the system was designed that the different communication channel can be assigned to each proper mass of terminal. The operating software was designed with menu driven user interface and have various functions for the convenience of users. The test result of the implemented system at the experimental network showed good performance and suitability for a coaxial CATV Status Monitoring System.

  • PDF

Implementation of Status Monitoring System based on RFID in Electric Power Equipment (발전설비장치에서 RFID기반 상태관리시스템 구현)

  • Han, Gun-Hee;Hong, Jin-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2379-2383
    • /
    • 2009
  • In this paper, it is reviewed implementation of information system base on RFID for management of power equipment, and the managed status items are input/out of resource, purchasing and ordering, drawing management, equipment specification, handling of operator, received order, stock control, production results, system management, and so on. the proposed paper is designed and implemented based on RFID status management system to support monitoring services of diagnosis the failure status monitoring.

Design and Implementation of A Dynamic API Platform for Interworking Across Heterogeneous Platforms (이기종 플랫폼간 상호연동을 위한 동적 API 플랫폼의 설계 및 구현)

  • Ryu, Minwoo;Cha, Si-Ho
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.17 no.2
    • /
    • pp.29-35
    • /
    • 2021
  • Recently, with the widespread use of the Internet of Things (IoT), the service structure has been studied to interact with various service domains. A common way to interact with other service domains is to develop the APIs needed to interact on the platform. However, to use a common method, we consider many costs and resources as APIs can increase while adding connections from other service domains. To address this issue, we propose the design and implementation of a dynamic API platform. The proposed platform can dynamically create APIs when requesting service applications, depending on the target service domain. To demonstrate the feasibility of the proposed platform, we develop a COVID-19 weekly infection status, regional infection status, and vaccination status service using dynamic APIs from the Public Data Portal using the proposed dynamic API platform and Node-RED.

The Study on Relation between Implementation of Six Sigma Quality Management and Financial Performance using Propensity Score Matching (식스 시그마 품질경영활동이 기업의 재무적 성과지표에 미치는 영향연구: 경향점수매칭을 이용하여)

  • Park, Byounghwa;Park, Taeyoung;Park, Minjae
    • Journal of Korean Society for Quality Management
    • /
    • v.44 no.2
    • /
    • pp.341-356
    • /
    • 2016
  • Purpose: The purpose of this paper is to study whether the adoption of Six Sigma quality management by a firm positively affects its financial performance. The correlation between the duration of Six Sigma implementation period and the financial status of the firm is investigated as well. Methods: We conduct the analysis using data from Manufacturing Industry Productivity Panel Survey 2013 provided by Korea Productivity Center and Ministry of Trade, Industry and Energy. Propensity score matching is used to reduce sample selection bias of observational study. Furthermore, we use multiple linear regression in order to study the relationship between the implementation of Six Sigma quality management and financial performance. The return on assets and ratio of net income to net sales are considered as dependent variable and implementation of Six Sigma as independent variable. Results: The indication of this analysis is that implementation of Six Sigma quality management does not significantly enhance financial status. The firms that adopted Six Sigma quality management were categorized into three groups according to the implementation period. Comparison of each group with the firms that do not adopt Six Sigma quality management does not show statistically significant enhancement of financial status. Conclusion: In conclusion, both adoption and duration of six sigma quality management do not affect financial performance significantly.

Current Status of Internal Dosimetry Methods and Radiological Regulations in Korea, Ukraine and European Community

  • Lee, Tae-Young;Lee, Jong-Il;Berkovski, Vladimir
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.1
    • /
    • pp.65-73
    • /
    • 2003
  • The paper discusses results of recent international intercomparison exercises on internal dose assessments, status of up to date internal dosimetry methods and the radiological legislation developed and implemented in Korea, European Union and Ukraine. The system of radiation protection in Korea is based on the Korean Atomic Energy Regulatory Enforcement on Safety Standards (Ministry Notice No. 2001-2). The notice is based on the recommendations in ICRP Publication 60 (1990) and IAEA Basic Safety Standards (1996). But the full implementation of the notice by the end of the year 2002 is not required because of the socio-economic situation and inexperience in internal radiation dosimetry Regulatory framework for internal radiation dosimetry is under development toward the full implementation of the notice from January 1, 2003. The system of radiation protection in Ukraine is based on the National radiation protection regulatory code NRBU-97. The code was developed and adopted in 1998 and replaced the Regulations of Former Soviet Union. The document is based on the ICRP Publication 60, Euratom Directive 96/29 and IAEA Basic Safety Standards (1996). The transitional period of 5 years (effected till January 2003) is established for implementation of all requirements of this new regulation. The system of radiation protection in the European Community is based on the Council Directive 96/29/Euratom, adopted in 1996 and enforced from 13 May 2000. Directive 96/29/Euratom has the status of the European law.

The Effect of Occupational Safety and Health Education on Occupational Accidents (산업안전보건교육이 산업재해발생에 미치는 영향에 관한 연구)

  • Jang, Konghwa;Ha, Kwonchul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.1
    • /
    • pp.90-98
    • /
    • 2016
  • Objectives: The aim of this study is to analyze the status of implementation of occupational safety and health education and evaluate the relation between the implementation of education and occupational accidents. Methods: This study used data on occupational safety and health education from the 2012 Current Status of Occupational Safety and Health survey by the Korea Occupational Safety and Health Agency. The sample is 7,010 persons working in relation to occupational safety and health in industry. An ANOVA test is used to analyze the status of and need for education. Poisson regression is used to evaluate the relation between education and occupational accidents. Results: The rate of implementation of education is 53.3% for periodic education on workers holding office positions, 68.3% for periodic education for workers not holding office positions, 60.3% for periodic education for persons holding managerial and supervisory positions, 65.5% for education provided upon hiring, 50.5% for education provided upon changes in work activities and 37.2% for special education. In the Poisson regression, these data strongly suggest that the probability of occupational accidents occurring with education implemented is much lower than without the implementation of any kind of safety and health education. Conclusions: It is clear that implementation of education has a positive effect on reducing occupational accidents, although its application in domestic industry is insufficient. Thus, it is concluded that education on occupational safety and health should be strengthened for the prevention of occupational accidents.