• Title/Summary/Keyword: Implementation Phase

Search Result 1,238, Processing Time 0.031 seconds

Static VAR Compensator-based Feedback Control Implementation for Self-Excited Induction Generator Terminal Voltage Regulation Driven by Variable-Speed Prime Mover

  • Ahmed, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제4권2호
    • /
    • pp.65-76
    • /
    • 2004
  • In this paper, the steady-state analysis of the three-phase self-excited induction generator (SEIG) driven by a variable-speed prime mover (VSPM) such as a wind turbine is presented. The steady-state torque-speed characteristics of the VSPM are considered with the three-phase SEIG equivalent circuit for evaluating the operating performances due to the inductive load variations. Furthermore, a PI closed-loop feedback voltage regulation scheme based on the static VAR compensator (SVC) for the three-phase SEIG driven by the VSPM is designed and considered for the wind power generation conditioner. The simulation and experimental results prove the practical effectiveness of the additional SVC with the PI controller-based feedback loop in terms of fast response and high performances.

역률과 전류 리플을 개선한 인터리브 AC/DC 컨버터에 관한 연구 (A Study of Interleaved AC/DC Converter to Improved Power Factor and Current Ripple)

  • 서상화;김용;권순도;배진용;엄태민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.152-155
    • /
    • 2009
  • In high power application, PFC(Power Factor Correction) pre-regulators are generally required. PFC pre-regulators could achieve unity power factor, reduce line input current harmonics and utilize full line power. Interleaving PFC converters could reduce input ripple current, output capacitor ripple current and inductor size. With this closed loop interleaving method, both two phase converters are working at the boundary between continuous and discontinuous mode and accurate 180 degree phase shift is achieved. Implementation of this strategy could be easily integrated to the control chip. Finally, experimental results of a two-phase interleaved boost PFC are presented to verify the discussed features.

  • PDF

빠른 응답 특성을 가지는 Average Current Mode Control 설계 기법 연구 (Average Current Mode Control Technique Having Fast Response)

  • 박해찬;김일송
    • 전력전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.231-239
    • /
    • 2017
  • A novel current control technique with fast response and application in an unbalanced system is proposed in this paper. Contrary to the conventional PI and dead-beat current control techniques, the proposed method is adopted to the valley current mode control (VCMC) and average current mode control (ACMC) methods to overcome the phase delay caused by conventional methods. The advantages of the proposed system are simplicity of structure and ease of implementation. The VCMC and ACMC methods are established and applied to the buck converter, boost converter, three-phase PWM converter, and three-phase inverter. The control performances of the proposed systems are shown by computer simulations and verified by experimental results.

빅 데이터 분석 기반의 스마트 농업 생산 전 단계를 위한 서비스 (Smart Farming Preliminary production phase service based on Big data Analysis)

  • 김동일;정희창
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 춘계학술대회
    • /
    • pp.194-196
    • /
    • 2021
  • 본 논문에서는 스마트농업의 생산 전 단계에서 생산 계획을 세워야 하는 농업 생산자와 유통사업자들에게 농업 정보 데이터를 제공하고 빅 데이터 분석에서 요구되는 다량의 데이터를 처리하고 분석할 수 있는 형태로 변환시켜 분석에 적용하는 스마트 농업 생산 전 서비스 모델을 제시한다. 수집된 데이터들을 저장 및 추출하기 위한 농업 정보 베이스의 구축 그리고 농업생산자와 유통사업자의 질의에 대응하여 적절한 자문을 수행할 수 있게 해주는 상호 소통 수단에 대한 기준 구조도 제시하였다.

  • PDF

Implementation of Space Vector Two-Arm Modulation for Independent Motor Control Drive Fed by a Five-Leg Inverter

  • Talib, Md Hairul Nizam;Ibrahim, Zulkifilie;Rahim, Nasrudin Abd.;Abu Hasim, Ahmad Shukri
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.115-124
    • /
    • 2014
  • This paper presents the implementation of two-arm modulation (TAM) technique for the independent control of a two-induction motor drive fed by a five-leg inverter (FLI). A carrier-based space vector pulse width modulation technique for TAM is proposed to generate switching signals for FLI. Two independent three-phase space vector modulators are utilized to control two motors. The motor drive system applies two separate indirect field-oriented control methods. The stationary voltage outputs from the vector control are synthesized in the three-phase space vector modulator to generate switching signals for FLI. The performance of the independent control of the motors and the voltage utilization factor are likewise analyzed. Simulation and experimental results verify the effectiveness of the proposed method for the independent control of the two-motor drive system. The proposed technique is successfully validated by dSPACE DS1103 experimental work.

웹 어플리케이션의 복잡도 예측에 관한 연구 (A Study of Estimation for Web Application Complexity)

  • 오성균;김미진
    • 한국컴퓨터정보학회논문지
    • /
    • 제9권3호
    • /
    • pp.27-34
    • /
    • 2004
  • 개발 패러다임이 점차 복잡한 웹 환경으로 전환되면서 복잡도에 대한 연구가 다시 활발해지고 있으나 아직 웹 어플리케이션의 구조나 복잡도 측정 매트릭에 정립된 이론이 부족한 실정이다. 또한 전통적 복잡도를 측정하는 프로그램 규모(LOC)나 순환복잡도 매트릭은 구현 후에나 알 수 있어 소프트웨어 개발주기 초기의 분석 및 설계 단계에는 큰 도움을 주지 못하고 있다. 본 연구에서는 실무에서 사용되는 6개 웹 프로젝트에 복잡도 인디케이터를 적용하여 결함 가능성이 높은 어플리케이션을 추출한다 추출한 61개의 프로그램을 대상으로 복잡도와 클래스 수 및 메소드 수에 대한 선형적 상관관계를 제안함으로써 웹어플리케이션의 복잡도를 구현 전에 미리 예측 가능하도록 하여 개발 프로세스의 인적 자원 관리나 비용 예측에 기여하고자 한다.

  • PDF

An Improved Stationary Frame-based Digital Current Control Scheme for a PM Synchronous Motor

  • Kim Kyeong-Hwa;Youn Myung-Joong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.174-178
    • /
    • 2001
  • An improved stationary frame-based digital current control technique for a permanent magnet (PM) synchronous motor is presented. Generally, the stationary frame current controller is known to provide the advantage of a simple implementation. However, there are some unavoidable limitations such as a steady-state error and a phase delay in the steady-state. On the other hand, in the synchronous frame current regulator, the regulated currents are dc quantities and a zero steady-state error can be obtained through the integral control. However, the need to transform the signals between the stationary and synchronous frames makes the implementation of a synchronous frame regulator complex. Although the PI controller in the stationary frame gives a steady-state error and a phase delay, the control performance can be greatly improved by employing the exact decoupling control inputs for the back EMF, resulting in an ideal steady-state control characteristics irrespective of an operating condition as in the synchronous PI decoupling controller. However, its steady-state response may be degraded due to the inexact cancellation inputs under the parameter variations. To improve the control performance in the stationary frame, the disturbance is estimated using the time delay control. The proposed scheme is implemented on a PM synchronous motor using DSP TMS320C31 and the effectiveness is verified through the comparative simulations and experiments.

  • PDF

영향도에 기초한 의사결정유형분석 구현을 위한 신경망 응용 (Applied Neural Net to Implementation of Influence Diagram Model Based Decision Class Analysis)

  • 박경삼;김재경;윤형재
    • Asia pacific journal of information systems
    • /
    • 제7권1호
    • /
    • pp.99-111
    • /
    • 1997
  • This paper presents an application of an artificial neural net to the implementation of decision class analysis (DCA), together with the generation of a decision model influence diagram. The diagram is well-known as a good tool for knowledge representation of complex decision problems. Generating influence diagram model is known to in practice require much time and effort, and the resulting model can be generally applicable to only a specific decision problem. In order to reduce the burden of modeling decision problems, the concept of DCA is introduced. DCA treats a set of decision problems having some degree of similarityz as a single unit. We propose a method utilizing a feedforward neural net with supervised learning rule to develop DCA based on influence diagram, which method consists of two phases: Phase l is to search for relevant chance and value nodes of an individual influence diagram from given decision and specific situations and Phase II elicits arcs among the nodes in the diagram. We also examine the results of neural net simulation with an example of a class of decision problems.

  • PDF

개회로 FOG의 폐회로 신호처리기의 구현 (Implementation of a closed-loop signal processor for the open-loop FOG)

  • 김도익;예윤해
    • 한국광학회지
    • /
    • 제8권5호
    • /
    • pp.426-430
    • /
    • 1997
  • 개회로 구성 광섬유 자이로스코프(FOG)를 위한 폐회로 신호처리의 가능성을 밝히기 위한 신호처리기를 제작하였다. 이 신호처리기는 종래의 위상추적 신호처리 방식을 전디지털로 구현한 것으로서 광검출기의 출력단에서 곧바로 디지털로 변환하여 신호처리함으로써 잡음에 강한 FOG용 신호처리기로 동작할 수 있다. 또 이 신호처리기는 위상편이량 $2\pi$ 범위에서 최대 36비트의 분해능력을 가져 가장 분해능이 높은 신호처리기가 될 가능성이 있으며, 크기가 $2\pi$ 이상인 위상편이량도 측정할 수 있다. 제작된 신호처리기를 전 광섬유 FOG에 적용한 결과 적분시간이 1초일 때 위상차 분해능은 $3\mu$rad(회전율 0.74deg/hr에 해당)로서 지구의 자전속도를 충분히 확인할 수 있는 정도였다.

  • PDF

An Improved Stationary Frame-based Digital Current Control Scheme for a PM Synchronous Motor

  • Kim, Kyeong-Hwa;Young, Myung-Joong
    • Journal of Power Electronics
    • /
    • 제1권2호
    • /
    • pp.88-98
    • /
    • 2001
  • An improved stationary frame-based digital current control technique for a permanent magnet(PM) synchronous motor is presented. Generally, the stationary frame current controller is known to provide the advantage of a simple implementation. However, there are some unavoidable limitations such as a steady-state error and a phase delay in the steady-state. On the other hand, in the synchronous frame current regulator the regulated currents are dc quantities and a zero steady-state error can be obtained through the integral control. However, the need to transform the signals between the stationary and synchronous frames makes the implementation of a synchronous frame regulator complex. Although the PI controller in the stationary frame gives a steady-state error and a phase delay, the control performance can be greatly improved by employing the exact decoupling control inputs for the back EMF., resulting in an ideal steady-state control characteristics irrespective of an operating condition as in the synchronous PI decoupling controller. However, its steady-state response may be degraded due to the inexact cancellation inputs under the parameter variations. To improve the control performance in the stationary frame, the disturbance is estimated using the time delay control. The proposed scheme is implemented on a PM synchronous motor using DSP TMS320C31 and the effectiveness is verified through the comparative simulations and experiments.

  • PDF