• Title/Summary/Keyword: Implantation alignment

Search Result 9, Processing Time 0.022 seconds

Wear and Implantation Tilt Measurements using X-ray and CAD (X-ray영상과 CAD를 이용한 인공고관절의 마모 및 식립각 측정법)

  • Lee, Jong Min;Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.107-114
    • /
    • 2018
  • Long-term complications such as loosening, wear, osteolytic lesion and granulomatous reaction by foreign bodies can occur, after total hip arthroplasty. The implantation alignment effects dislocation and wear, according to its amount and direction. Wear particles in total hip arthroplasty brings about biochemical complications such as osteolysis or send wear. In this sense, it is important to regularly check wear and alignment of total hip replacement. Because the wear in followup of 10 years may remain in a small amount, like a 1 or 2 mm generally, somewhat precise measurement tool has to be established. The wear and alignment measurement softwares commercially available currently lack in project saving or reproducibility. This study suggests a reliable method for the measurement using an X-ray image and a CAD software. The proposed method can be executed only if having a CAD software under most of current general clinical radiographical environment. The proposed was revealed through tests for the method to have accuracy of 0.06 mm with precision of 0.05 mm for wear measurement, and precision of 0.27 degrees for tilt measurement.

Total Knee Arthroplasty (슬관절 전 치환 성형술)

  • Lee, Dong-Chul;Sohn, Wook-Jin
    • Journal of Yeungnam Medical Science
    • /
    • v.21 no.1
    • /
    • pp.1-11
    • /
    • 2004
  • Total knee arthroplasty has become a common procedure for treatment of severe osteoarthritis, rheumatoid arthritis and post-traumatic arthritis. In the past, failure of total knee arthroplasty was commonly attributable to aseptic loosening, often associated with component malalignment, soft tissue imbalance. With improved surgical instrumentation and soft tissue balancing techiniques, failure secondary to mechanical loosening has been minimal. But surgeons are still dissatisfied with implant malalignment. Correct tibiofemoral alignment seems to be particularly important since it is generally agreed that axial deviation and imprecise implantation may lead to loosening of the implant component. Navigation systems and robotic techniques could potentially solve problems of imprecision in traditional total knee arthroplasty. It is expected that the success rate and longevity of total knee arthroplasty will be improved during the twenty first century.

  • PDF

Self-Aligned Offset Poly-Si TFT using Photoresist reflow process (Photoresist reflow 공정을 이용한 자기정합 오프셋 poly-Si TFT)

  • Yoo, Juhn-Suk;Park, Cheol-Min;Min, Byung-Hyuk;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1582-1584
    • /
    • 1996
  • The polycrystalline silicon thin film transistors (poly-Si TFT) are the most promising candidate for active matrix liquid crystal displays (AMLCD) for their high mobilities and current driving capabilities. The leakage current of the poly-Si TFT is much higher than that of the amorphous-Si TFT, thus larger storage capacitance is required which reduces the aperture ratio fur the pixel. The offset gated poly-Si TFTs have been widely investigated in order to reduce the leakage current. The conventional method for fabricating an offset device may require additional mask and photolithography process step, which is inapplicable for self-aligned source/drain ion implantation and rather cost inefficient. Due to mis-alignment, offset devices show asymmetric transfer characteristics as the source and drain are switched. We have proposed and fabricated a new offset poly-Si TFT by applying photoresist reflow process. The new method does not require an additional mask step and self-aligned ion implantation is applied, thus precise offset length can be defined and source/drain symmetric transfer characteristics are achieved.

  • PDF

Self-aligned Offset Gated Poly-Si TFTs by Employing a Photo Resistor Reflow Process (Photo Resistor Reflow 방법을 이용한 오프셋 마스크를 이용하지 않는 새로운 자기 정합 폴리 실리콘 박막 트랜지스터)

  • Park, Cheol-Min;Min, Byung-Hyuk;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1085-1087
    • /
    • 1995
  • A large leakage current may be one of the critical issues for poly-silicon thin film transistors(poly-Si TFTs) for LCD applications. In order to reduce the leakage current of poly-Si TFTs, several offset gated structures have been reported. However, those devices, where the offset length in the source region is not same as that in the drain region, exhibit the asymmetric electrical performances such as the threshold voltage shift and the variation of the subthreshold slope. The different offset length is caused by the additional mask step for the conventional offset structures. Also the self-aligned implantation may not be applicable due to the mis-alignment problem. In this paper, we propose a new fabrication method for poly-Si TFTs with a self-aligned offset gated structure by employing a photo resistor reflow process. Compared with the conventional poly-Si TFTs, the device is consist of two gate electrodes, of which one is the entitled main gate where the gate bias is employed and the other is the entitled subgate which is separate from both sides of the main gate. The poly-Si channel layer below the offset oxide is protected from the injected ion impurities for the source/drain implantation and acts as an offset region of the proposed device. The key feature of our new device is the offset lesion due to the offset oxide. Our experimental results show that the offset region, due to the photo resistor reflow process, has been successfully obtained in order to fabricate the offset gated poly-Si TFTs. The advantages of the proposed device are that the offset length in the source region is the same as that in the drain region because of the self-aligned implantation and the proposed device does not require any additional mask process step.

  • PDF

Maxillary protraction using customized mini-plates for anchorage in an adolescent girl with skeletal Class III malocclusion

  • Liang, Shuran;Xie, Xianju;Wang, Fan;Chang, Qiao;Wang, Hongmei;Bai, Yuxing
    • The korean journal of orthodontics
    • /
    • v.50 no.5
    • /
    • pp.346-355
    • /
    • 2020
  • The treatment of skeletal Class III malocclusion in adolescents is challenging. Maxillary protraction, particularly that using bone anchorage, has been proven to be an effective method for the stimulation of maxillary growth. However, the conventional procedure, which involves the surgical implantation of mini-plates, is traumatic and associated with a high risk. Three-dimensional (3D) digital technology offers the possibility of individualized treatment. Customized mini-plates can be designed according to the shape of the maxillary surface and the positions of the roots on cone-beam computed tomography scans; this reduces both the surgical risk and patient trauma. Here we report a case involving a 12-year-old adolescent girl with skeletal Class III malocclusion and midface deficiency that was treated in two phases. In phase 1, rapid maxillary expansion and protraction were performed using 3D-printed mini-plates for anchorage. The mini-plates exhibited better adaptation to the bone contour, and titanium screw implantation was safer because of the customized design. The orthopedic force applied to each mini-plate was approximately 400-500 g, and the plates remained stable during the maxillary protraction process, which exhibited efficacious orthopedic effects and significantly improved the facial profile and esthetics. In phase 2, fixed appliances were used for alignment and leveling of the maxillary and mandibular dentitions. The complete two-phase treatment lasted for 24 months. After 48 months of retention, the treatment outcomes remained stable.

Rotational Stability of AcrySof Toric Intraocular Lens Over Time: Influence of Capsulorhexis Contraction

  • Kim, Joong Hee;Cho, Kyong Jin
    • Medical Lasers
    • /
    • v.9 no.1
    • /
    • pp.44-50
    • /
    • 2020
  • Background and Objectives To evaluate the rotational stability of AcrySof toric intraocular lenses (IOL) by considering lapse of postoperative time and influence of capsulorhexis contraction. Materials and Methods A prospective, masked, single center study was conducted on 19 patients who had undergone microcoaxial cataract surgery and AcrySof toric IOL implantation. Slit-lamp retroillumination photographs of anterior segments were obtained from all patients after 1 week, 1 month and 3 months post-surgery. The degree of alteration of the postoperative IOL axis alignment and the amount of anterior capsular shrinkage were analyzed using Adobe Photoshop software. Results The mean degree of toric IOL axis misalignment was 2.18 (±20.2) degrees at 3 months follow-up. Quadrant analysis of the capsulorhexis aperture area at 1 week and 1 month post-operative, showed counterclockwise IOL rotation when the capsule contraction was dominant in the haptic part as well as clockwise rotation when dominant in the non-haptic part (p = 0.015). Conclusion The direction and degree of AcrySof toric IOL rotation differed throughout the follow-up period. Since most misalignments were found on the first post-operative day, physicians should try to minimize peri-operative risk factors that influence IOL rotation. There was also a correlation between the part of anterior capsule contraction and the direction of IOL rotation.

Enhancement of 1,3-Dihydroxyacetone Production from Gluconobacter oxydans by Combined Mutagenesis

  • Lin, Xi;Liu, Sha;Xie, Guangrong;Chen, Jing;Li, Penghua;Chen, Jianhua
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.11
    • /
    • pp.1908-1917
    • /
    • 2016
  • Wild strain L-6 was subjected to combined mutagenesis, including UV irradiation, atmospheric and room temperature plasma, and ion beam implantation, to increase the yield of 1,3-dihydroxyacetone (DHA). With application of a high-throughput screening method, mutant Gluconobacter oxydans I-2-239 with a DHA productivity of 103.5 g/l in flask-shake fermentation was finally obtained with the starting glycerol concentration of 120 g/l, which was 115.7% higher than the wild strain. The cultivation time also decreased from 54 h to 36 h. Compared with the wild strain, a dramatic increase in enzyme activity was observed for the mutant strain, although the increase in biomass was limited. DNA and amino acid sequence alignment revealed 11 nucleotide substitutions and 10 amino acid substitutions between the sldAB of strains L-6 and I-2-239. Simulation of the 3-D structure and prediction of active site residues and PQQ binding site residues suggested that these mutations were mainly related to PQQ binding, which was speculated to be favorable for the catalyzing capacity of glycerol dehydrogenase. RT-qPCR assay indicated that the transcription levels of sldA and sldB in the mutant strain were respectively 4.8-fold and 5.4-fold higher than that in the wild strain, suggesting another possible reason for the increased DHA productivity of the mutant strain.

Patient-specific Guides Using 3-dimensional Reconstruction Provide Accuracy and Reproducibility in Reverse Total Shoulder Arthroplasty

  • Yoon, Jong Pil;Kim, Dong Hyun;Jung, Jae Wook;Lee, Chang-Hwa;Min, Seunggi;Lee, Hyun Joo;Kim, Hee-June
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.1
    • /
    • pp.16-23
    • /
    • 2019
  • Background: We aimed to evaluate whether the use of our novel patient-specific guide (PSG) with 3-dimensional reconstruction in reverse total shoulder arthroplasty (RTSA) would allow accurate and reliable implantation of the glenoid and humeral components. Methods: 20 fresh-frozen cadaveric shoulders were used. The PSG group (n=10) and conventional group (n=10) was evaluated the accuracy and reproducibility of implant positioning between before and after surgery on the computed tomography image. Results: The superoinferior and anteroposterior offset in the glenoid component were $0.42{\pm}0.07$, $0.50{\pm}0.08$ in the conventional group and $0.45{\pm}0.03$, $0.46{\pm}0.02$ in the PSG group. The inclination and version angles were $-1.93^{\circ}{\pm}4.31^{\circ}$, $2.27^{\circ}{\pm}5.91^{\circ}$ and $0.46^{\circ}{\pm}0.02^{\circ}$, $3.38^{\circ}{\pm}2.79^{\circ}$. The standard deviation showed a smaller difference in the PSG group. The anteroposterior and lateromedial humeral canal center offset in the humeral component were $0.45{\pm}0.12$, $0.48{\pm}0.15$ in the conventional group and $0.46{\pm}0.59$ (p=0.794), $0.46{\pm}0.06$ (p=0.702) in the PSG group. The PSG showed significantly better humeral stem alignment. Conclusions: The use of PSGs with 3-dimensional reconstruction reduces variabilities in glenoid and humerus component positions and prevents extreme positioning errors in RTSA.

Verification of X-sight Lung Tracking System in the CyberKnife (사이버나이프에서 폐종양 추적 시스템의 정확도 분석)

  • Huh, Hyun-Do;Choi, Sang-Hyoun;Kim, Woo-Chul;Kim, Hun-Jeong;Kim, Seong-Hoon;Cho, Sam-Ju;Min, Chul-Ki;Cho, Kwang-Hwan;Lee, Sang-Hoon;Choi, Jin-Ho;Lim, Sang-Wook;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.174-179
    • /
    • 2009
  • To track moving tumor in real time, CyberKnife system imports a technique of the synchrony respiratory tracking system. The fiducial marker which are detectable in X-ray images were demand in CyberKnife Robotic radiosurgery system. It issued as reference markers to locate and track tumor location during patient alignment and treatment delivery. Fiducial marker implantation is an invasive surgical operation that carries a relatively high risk of pneumothorax. Most recently, it was developed a direct lung tumor registration method that does not require the use of fiducials. The purpose of this study is to measure the accuracy of target applying X-sight lung tracking using the Gafchromic film in dynamic moving thorax phantom. The X-sight Lung Tracking quality assurance motion phantom simulates simple respiratory motion of a lung tumor and provides Gafchromic dosimetry film-based test capability at locations inside the phantom corresponding to a typical lung tumor. The total average error for the X-sight Lung Tracking System with a moving target was $0.85{\pm}0.22$ mm. The results were considered reliable and applicable for lung tumor treatment in CyberKnife radiosurgery system. Clinically, breathing patterns of patients may vary during radiation therapy. Therefore, additional studies with a set real patient data are necessary to evaluate the target accuracy for the X-sight Lung Tracking system.

  • PDF