• 제목/요약/키워드: Implantable microphone

검색결과 11건 처리시간 0.028초

피부에 의한 이득 감쇠를 줄이기 위한 FEA 시뮬레이션 기반의 이식형 마이크로폰 설계 및 구현 (Design and Fabrication of an Implantable Microphone for Reduction of Skin Damping Effect through FEA Simulation)

  • 한지훈;김민우;김동욱;성기웅;조성목;박일용;조진호
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권1호
    • /
    • pp.59-65
    • /
    • 2008
  • Nowadays, implantable hearing aids have been developed to solve the problems of conventional hearing aids. In case of fully implantable hearing aids, an implantable microphone is necessary to receive sound signal beneath the skin. Normally, an implantable microphone has poor frequency response characteristics in high frequency bands of acoustic signal due to the high frequency attenuation effect of skin after implantation to human body. In this paper, the implantable microphone is designed to reduce the high frequency attenuation effect of a skin by putting its resonance frequency at the attenuated range through a finite element analysis (FEA) simulation. The designed implantable microphone through the simulated results has been fabricated by manufacturing process using bio-compatible materials. By the several in-vitro experiments with pig skin, it has been verified that the designed implantable microphone has a resonance frequency around the starting part of the attenuated range and reduces the attenuation effect.

고막이식형 마이크로폰을 위한 이식형 인공중이 적응 피드백 제거기 구현 (An Adaptive Feedback Canceller for Fully Implantable Hearing Device Using Tympanic Membrane Installed Microphone)

  • 김태윤;김명남;조진호
    • 한국멀티미디어학회논문지
    • /
    • 제19권2호
    • /
    • pp.189-199
    • /
    • 2016
  • Many implantable hearing aids are being developed as alternatives to conventional hearing aids which has inconveniences for use and social stigma that make hearing-impaired people avoid to wear it. Particularly, the fully-implantable middle ear hearing devices (F-IMEHD) are being actively studied for mixed or sensorineural hearing impaired people. In development of F-IMEHD, the most difficult problem is improving the performance of implantable microphone. Recently, Cho et al. have studied the tympanic membrane installed microphone which has better sensitivity and is easier to operate on patient than the microphone implanted under the skin. But, it may cause howling problem due to the feedback signal via oval window and ossicle chain from the transducer on round window in the middle ear cavity, therefore, a feedback canceller is necessary. In this paper, we designed NLMS (normalized least mean square) adaptive feedback canceller for F-IMEHD with tympanic membrane installed microphone and a transducer implemented at round window, and computer simulation was performed to verify its operation. The designed adaptive feedback canceller has a delay filter, a 64 point FIR fixed filter and a 8-tap adaptive FIR filter. Computer simulation of the feedback path is modeled by using the data obtained through human cadaver experiment.

골전도를 통한 생체신호가 이식형 마이크로폰에 미치는 영향 및 고찰 (Study and Effects of Bone Conducted Signal on the Implantable Microphone)

  • 우승탁;정의성;김명남;조진호
    • 재활복지공학회논문지
    • /
    • 제4권1호
    • /
    • pp.29-34
    • /
    • 2010
  • 완전 이식형 보청기는 기존 보청기가 가지고 있는 여러 문제점들을 해결하기 위해 연구 개발되고 있다. 이러한 완전이식형 보청기에 사용되는 이식형 마이크로폰은 일반적으로 측두부의 피부아래 이식된다. 그런데 이식된 마이크로폰의 특성은 음식을 먹거나 치아의 마찰, 생체동잡음에 의해 영향을 받을 수 있다. 본 논문에서는 이식된 마이크로폰에 골전도를 통해 전달된 생체잡음신호가 미치는 영향을 조사하기 위하여, 사람의 측두부 및 피부의 특성이 유사한 물리모델을 제작하여, 이식된 마이크로폰의 감도측정실험을 수행하였다. 1 kHz의 순음신호를 이식된 마이크로폰에 인가하고, 동시에 여러 주파수대의 정현파진동을 인공뼈에 인가하여 측정되었다. 그 결과 마이크로폰의 출력은 골전도를 통한 신호의 영향을 받아 왜곡될 수 있으며, 그 영향은 주파수대역에 따라 달라짐을 확인하였다.

Design of Implantable Microphone for Artificial Middle Ear System

  • Kim Min-Kyu;Lim Hyung-Gyu;Yoon Young-Ho;Lee Jyung-Hyun;Park Il-Yong;Song Byung-Seop;Kim Myoung-Nam;Cho Jin-Ho
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권3호
    • /
    • pp.139-144
    • /
    • 2005
  • An implantable microphone that can be utilized as part of a totally implantable hearing aid is designed and implemented. The proposed microphone is implanted in the center of the pinna, and designed to ensure the speech frequency range and the appropriate sensitivity. The characteristics of the proposed microphone are evaluated using a finite element analysis (FEA). The microphone is composed of a small electric condenser microphone, titanium case 6.2mm in diameter and 3mm high, and $10{\mu}m$ SUS316L vibrating membrane in contact with hypodermic tissue to maintain the sensitivity of the microphone. The microphone components are all made of biocompatible materials, then the assembled microphone is hermetically sealed using a polymer and ceramic. Experiments with the fabricated microphone confirm an operational bandwidth of up to 5kHz without any decline of sensitivity in 6mm of hypodermic tissue.

완전 이식형 인공중이용 마이크로폰의 위치 결정을 위한 물리적 귀 모델의 구현 (Implementation a Physical Ear Model for Determinating Location of the Microphone of Fully Implantable Middle Ear Hearing Device)

  • 김동욱;성기웅;임형규;김민우;정의성;이장우;이명원;이정현;김명남;조진호
    • 재활복지공학회논문지
    • /
    • 제2권1호
    • /
    • pp.27-33
    • /
    • 2009
  • 일반적으로, 완전 이식형 인공중이의 이식형 마이크로폰은 측두골 부근에 이식되어진다. 이 경우, 마이크로폰의 진동막이 외부 충격이나 생체 노이즈의 영향 받을 수 있으며 이런 문제를 해결하기 위하여 이식용 마이크로폰을 외이도 내에 이식하는 방법을 고려할 수 있다. 그러나 이소골에 이식된 진동 트랜스듀서에 의해서 고막으로부터 외이도 방향으로 음향 반향이 발생할 가능성이 있다. 본 논문에서는 사람의 귀와 유사한 특성을 가지는 귀 모델을 제작하여 프로브 마이크로폰의 위치를 변경해가며 외이도의 음향 반향을 측정하였고 실험결과를 통하여 외이도 내에서의 마이크로폰의 이식 위치를 추정해 보았다. 분석 결과 외이도에 마이크로폰을 이식할 경우 고막에서 멀어질수록 반향 신호가 감소함을 확인할 수는 있었으나, 반향 신호를 완전히 제거할 수 없기 때문에 외이도에 마이크로폰을 이식하기에는 부적합한 것으로 예상된다.

  • PDF

저작운동으로 인한 진동 잡음 신호의 경감을 위한 측두골 이식형 마이크로폰의 설계 (The Design of Temporal Bone Type Implantable Microphone for Reduction of the Vibrational Noise due to Masticatory Movement)

  • 우승탁;정의성;임형규;이윤정;성기웅;이정현;조진호
    • 센서학회지
    • /
    • 제21권2호
    • /
    • pp.144-150
    • /
    • 2012
  • A microphone for fully implantable hearing device was generally implanted under the skin of the temporal bone. So, the implanted microphone's characteristics can be affected by the accompanying noise due to masticatory movement. In this paper, the implantable microphone with 2-channels structure was designed for reduction of the generated noise signal by masticatory movement. And an experimental model for generation of the noise by masticatory movement was developed with considering the characteristics of human temporal bone and skin. Using the model, the speech signal by a speaker and the artificial noise by a vibrator were supplied simultaneously into the experimental model, the electrical signals were measured at the proposed microphone. The collected signals were processed using a general adaptive filter with least mean square(LMS) algorithm. To confirm performance of the proposed methods, the correlation coefficient and the signal to noise ratio(SNR) before and after the signal processing were calculated. Finally, the results were compared each other.

이식형 마이크로폰과 진동체를 갖는 인공중이의 이득 보상을 위한 주파수 특성 고찰 (Study on frequency response of implantable microphone and vibrating transducer for the gain compensation of implantable middle ear hearing aid)

  • 정의성;성기웅;임형규;이장우;김동욱;이정현;김명남;조진호
    • 센서학회지
    • /
    • 제19권5호
    • /
    • pp.361-368
    • /
    • 2010
  • ACROSS device, which is composed of an implantable microphone, a signal processor, and a vibrating transducer, is a fullyimplantable middle ear hearing device(F-IMEHD) for the recovery of patients with hearing loss. And since a microphone is implanted under skin and tissue at the temporal bones, the amplitude of the sound wave is attenuated by absorption and scattering. And the vibrating transducer attached to the ossicular chain caused also the different displacement from characteristic of the stapes. For the gain control of auditory signals, most of implantable hearing devices with the digital audio signal processor still apply to fitting rules of conventional hearing aid without regard to the effect of the implanted microphone and the vibrating transducer. So it should be taken into account the effect of the implantable microphone and the vibrating transducer to use the conventional audio fitting rule. The aim of this study was to measure gain characteristics caused by the implanted microphone and the vibrating transducer attached to the ossicle chains for the gain compensation of ACROSS device. Differential floating mass transducers (DFMT) of ACROSS device were clipped on four cadaver temporal bones. And after placing the DFMT on them, displacements of the ossicle chain with the DFMT operated by 1 $mA_{peak}$ current was measured using laser Doppler vibrometer. And the sensitivity of microphones under the sampled pig skin and the skin of 3 rat back were measured by stimulus of pure tones in frequency from 0.1 to 8.9 kHz. And we confirmed that the microphone implanted under skin showed poorer frequency response in the acoustic high-frequency band than it in the low- to mid- frequency band, and the resonant frequency of the stapes vibration was changed by attaching the DFMT on the incus, the displacement of the DFMT driven with 1 $mA_{rms}$ was higher by the amount of about 20 dB than that of cadaver's stapes driven by the sound presssure of 94 dB SPL in resonance frequency range.

완전 이식형 인공중이용 적합 소프트웨어의 구현 (Implementation of Fitting Software for Fully Implantable Middle Ear Hearing Device)

  • 이장우;정의성;임형규;이정현;성기웅;김명남;조진호
    • 재활복지공학회논문지
    • /
    • 제3권1호
    • /
    • pp.21-25
    • /
    • 2009
  • 일반적으로 완전 이식형 인공중이는 이식형 마이크로폰과 진동 트랜스듀서를 포함한 모든 구성 요소가 측두골 부근 피부 아래에 이식되는 보청기이다. 마이크로폰과 트랜스듀서의 경우 이식 전과 후의 동작 주파수 특성 등이 달라진다. 이러한 특성변화와 이식 대상자의 청력특성에 알맞은 보청기 동작을 수행하기 위해 적합과정을 수행하게 된다. 일반 공기전도형 보청기나 부분 이식형 보청기의 경우 적합을 위한 전선 연결부가 존재하나 완전이식형의 경우에는 몸속에 모두 이식됨으로 이러한 전선의 연결이 어려우며 이에 따라 기존 보청기의 적합 프로그램을 적용하는 하드웨어를 이용한 적합이 어렵다. 본 논문에서는 완전 이식형 인공중이를 위한 무선 적합 하드웨어에 적용 가능한 적합 소프트웨어를 설계 및 구현하였다. 구현한 적합 소프트웨어는 마이크로폰과 트랜스듀서의 특성과 난청자의 청력도를 반영하여 적절한 청력 보상치를 산출할 수 있다.

  • PDF

무선 충전 가능한 블루투스 방식의 체내 음향신호 전송용 이식형 바이오 텔레메트리 시스템 구현 (Implementation of Implantable Bluetooth Bio-telemetry System for Transmitting Acoustic Signals in the Body with Wireless Recharging Function)

  • 이상준;김명남;이정현;임형규;조진호
    • 한국멀티미디어학회논문지
    • /
    • 제18권5호
    • /
    • pp.652-662
    • /
    • 2015
  • It is necessary to develop small, implantable bio-telemetry systems which can measure and transmit patients' bio-signals from internal body to external receiver. When measuring bio-signals, like electrical bio-signals, acoustic bio-signal measurement has also a big clinical usefulness. But, sound signal has larger frequency bandwidth than any other bio-signals. When considering these issues, a wireless telemetry system which has rapid data transmission rate proportional to wide frequency bandwidth is necessary to be developed. The bluetooth module is used to overcome the data rate limitation caused by the large frequency bandwidth. In this paper, a novel multimedia bluetooth biotelemetry system was developed which consists of transmitter module located in the body and receiver device located outside of the body. The transmitter consists of microphone, bluetooth, and wireless charging device. And the receiver consists of bluetooth and codec system. The sound inside the skin is captured by microphone and sent to receiver by bluetooth while charging. The wireless charging system constantly supplies the electric power to the system. To verify the performance of the developed system, an in vitro experiment has been performed. The results show that the proposed biotelemetry system has ability to acquire the sound signals under the skin.

이식형 양심실 보조 장치에 사용된 기계식 판막의 음향 스펙트럼 특성 (Spectral Properties of the Sound From the Mechanical Valve Employed in an Implantable Biventricular Assist Device)

  • 최민주;이서우;이혁수;민병구
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권5호
    • /
    • pp.439-448
    • /
    • 2001
  • 이식형 양심실 보조 장치 (Biventricular Assist Device, BVAD)에서 판막이 닫힐 때 나는 소리의 특성과 판막의 물리적인 상태의 상관성을 고찰하였다. 본 연구에서 Bj rk Shiley Convexo Concave tilting disk 판막을 사용했으며, 모의 순환계와 양의 체내에서 동작하는 BVAD 에서 판막음을 측정하였다. 모의 순환계에서는 정상 판막. 기계적으로 손상된 판막. 모의 혈전이 형성된 판막의 3가지를 고려하였다. 양에 이식된 BVAD의 경우, 이식 후 1일부터 5일 동안 규칙적인 간격으로 판막음을 측정하였다. 측정된 신호의 스펙트럼 특성은 Multiple Signal Classification (MUSIC)을 이용하여 추정하였다. MUSIC의 최적 차수는 Bayesian Information Criterion (BIC)을 이용하여 계산하였다. 실험 결과, 판막의 기계적인 손상은 판막 폐쇄음의 주파수 스펙트럼 구조를 변화시키고 있으며, 혈전의 형성은 판막음 스펙트럼의 기본 구조는 유지하지만 피크 주파수와 에너지의 크기를 변화시키는 것으로 관찰되었다. 최대 에너지를 가지는 MSP (maximum spectral peak)는 정상 판막에서는 2 kHz에 위치하고 있으나 모의 혈전을 부탁한 판막에서는 3 kHz로 이동하였다. 손상된 판막은 7 kHz 부근에서 강한 피크 보이고 있다 실험 동물 내에서 판막에 혈전이 형성되어감에 따라 판막음은 저주파 성분 (〈 2kHz)이 상대적으로 크게 감소하였고, Ist 2nd. 3rd MSP 주파수는 약간씩 상승하였다. 또한 혈전이 형성되어 감에 따라 반복해서 측정된 판막음의 1st, 2nd. 3rd MSP 주파수의 변화 정도 및 BIC 차수는 감소하는 것으로 나타났다

  • PDF