• 제목/요약/키워드: Implantable Device

검색결과 99건 처리시간 0.031초

마약길항제의 방출 제어형 제제 (제1보) : 생체분해성 polyphosphazenes의 합성과 나록손 이식제제의 제조 및 용출특성 (Controlled Release Dosage Form of Narcotic Antagonist(I): Synthesis of Biodegradable Polyphosphazenes and Preparation and Release Characteristics of Naloxone Implant)

  • 박주애;이승진;김형국;김길수
    • Journal of Pharmaceutical Investigation
    • /
    • 제25권2호
    • /
    • pp.109-116
    • /
    • 1995
  • For the administration of narcotic antagonist with short half-life and low patient compliance, the sustained release system using biodegradable matrix is effective. Polyphosphazenes are of considerable interest as biodegradable matrix systems for controlled release of drugs. In this study, biodegradable polyphosphazenes available for the sustained release implantable device were synthesized, and their application was examined. Poly[dichlorophosphazene] was synthesized by solution polymerization method and confirmed with IR spectrum. Poly[bis(ethyl glycinate) phosphazene] and poly[ (diethyl glutamate)-co-(ethyl glycinate)phosphazene] were then produced by substitution of amino acid alkyl esters for chloride side groups. Using these polymers, the implantable devices of 1 mm thickness and $10{\times}10\;mm$ size containing naloxone hydrochloride were prepared and their release and degradation profiles were measured. In the case of poly[bis(ethyl glycinate)phosphazene] with swelling characteristics, degradation rate was slower than the release rate, showing that the release rate is partly dependent on the swelling rate. In contrast, the degradation rate of polyl[(diethyl glutamate)-co-(ethyl glycinate)phosphazene] matrix was identical with release rate of naloxone hydrochloride. On the basis of these results, it is expected that these polymers can be applied to sustained release implantable systems delivering narcotic antagonist.

  • PDF

인체 삽입형 인공와우를 위한 무선 통신 시스템 (Wireless Communication Systems for Human Implantable Artificial Cochlea)

  • 한성민;신재섭;조재욱;장종문;최홍수;최지웅
    • 한국통신학회논문지
    • /
    • 제38C권12호
    • /
    • pp.1150-1158
    • /
    • 2013
  • 인공와우는 와우의 물리적 또는 기능적 손상으로 유발된 청각장애를 가지고 있는 환자에게 청각기능을 회복하는 매우 효과적인 수단으로 알려져 있다. 하지만 현재까지 상용화된 인공와우 제품은 크기, 전력소모와 같은 측면에서 휴대성이 불편하여 아직 많은 한계점을 가지고 있다. 이러한 단점을 해결하기 위한 새로운 방식의 인체 삽입형 인공와우 개발이 요구되고 있다. 본 논문에서는 최근 연구 개발 중인 인체 삽입형 인공와우를 구성하는 센서부, 자극부, 무선통신부 등의 설계와 본 시스템에 탑재되는 통신시스템의 특징 및 시뮬레이션을 통한 평가결과 등을 기술하였다.

암 환자 통증 조절을 위한 이식형 약물 주입 펌프 개발 (Development of an Implantable Drug Infusion Pump for Pain Control in Cancer Patients)

  • 백두진;박준우;홍소영;이철한;김광기;조영호;김대현
    • 한국유체기계학회 논문집
    • /
    • 제12권3호
    • /
    • pp.31-37
    • /
    • 2009
  • This paper presents a implantable intrathecal drug infusion pump for pain control in cancer patients. This device consists of micropump module, drug reservoir module and control module. The micropump module using cam-follower mechanism composed of small-sized four cams and four followers. Each followers is driven by a cam and liquid is discharged by a sequential reciprocal motion of the followers. The advantage of this structure is that it allows the pump to be clean and valveless. The drug reservoir module composed of drug chamber, gas chamber and diaphragm. The control module composed of battery, wireless communication unit and controller. To design a small-sized, low power pump some analysis were performed to determine the design parameters. To verify the feasibility of the experiment, a prototype was manufactured and its operating characteristics were investigated. Experimental results were in accordance with the expected results obtained from analysis.

유헬스케어의 무선환경에 적합한 WiMAX 보안 측정 및 분석 (Measuring and Analyzing WiMAX Security adopt to Wireless Environment of U-Healthcare)

  • 정윤수
    • 디지털융복합연구
    • /
    • 제11권3호
    • /
    • pp.279-284
    • /
    • 2013
  • IT 기술에 의료기술이 접목되면서 유헬스케어 서비스에 적용한 체내삽입장치는 환자의 민감한 생체정보를 제3자에게 쉽게 유출되어 환자의 프라이버시 침해되지 않도록 무선 액세스 네트워크 구간에 높은 데이터율과 이동성을 지원하는 강한 보안이 필요하다. 본 논문에서는 이동성을 가지는 환자가 체내삽입장치내 환자의 생체정보를 무선 액세스 네트워크 구간에서 제3자에게 불법적으로 노출되지 않도록 무선 액세스 네트워크에 WiMAX 네트워크을 구축하여 이동 환자의 생체정보가 안전하게 송 수신될 수 있도록 테스트 베드를 구축하여 WiMAX 네트워크의 보안 성능 측정 및 평가를 수행한다. 특히, 본 논문에서는 WiMAX 보안 compliance, WiMAX MAC 상의 IPSec, MAC 계층에서 ECDH 수행 등에서 데이터 보안, MAC 제어 메시지 보안, 핸드오버 연결 지연, 프레임 손실 및 대역폭 등을 비교평가한다.

일회용 의료기기에 적용을 위한 ISO 14971:2019 분석과 Periodic Safety Update Report 작성 방법 - Medical Device Regulation 2017/745 요구사항 중심으로 (ISO14971:2019 Detailed Analysis and Periodic Safety Update Report Establishment Method for the Single Use Medical Device - Focusing on Medical Device Regulation 2017/745 requirements)

  • 박상민;류규하
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권1호
    • /
    • pp.1-10
    • /
    • 2023
  • With the announcement of MEDICAL DEVICE REGULATION 2017/745 (MDR) on April 5 2017, medical device manufacturers shall apply ISO 14971:2019 (3rd) revised in December 2019. However, there is not much related information and guidance available to medical device manufacturers, especially single use medical device. Risk management process basically follow 5 steps which are Risk Analysis, Risk Evaluation, Risk Control, Evaluation of overall residual risk and post-production activities. The purpose of this study is to provide a guidance of from risk analysis with Failure Mode and Effects Analysis (FMEA) table to overall residual risk evaluation for the single use medical device and to reflect it in a Periodic Safety Update Reports (PSUR) to satisfy with MDR requirements with single use medical device which are widely used and manufactured FDA class 2 or CE class IIb as examples. For this study, single use medical device manufacturer can adopt ISO 14971:2019 in accordance with MDR requirements and it can be extended to the PSUR. But there are still limitations to adopt to the all-single use medical device especially high class, private device and implantable device. So, Competent Authority (CA) shall publish more guidance for the single use medical device.

Sequential Quadratic Programming 방법을 이용한 인공중이용 플로팅 매스 트랜스듀서의 집중 모델 파라미터 추정 (Lumped Model Parameter Estimation of Floating Mass Transducers based on Sequential Quadratic Programming Method for IMEHDs)

  • 박일용
    • 재활복지공학회논문지
    • /
    • 제5권1호
    • /
    • pp.59-64
    • /
    • 2011
  • 인공 중이 (IMEHD, implantable middle ear hearing device)용 플로팅 매스 트랜스듀서는 제작 과정상에서 발생하는 구조적 오차 및 제작 결합시의 문제점들로 인해 설계 시 의도와 다른 진동 특성을 가질 수 있게 되고, 이렇게 제작된 진동 트랜스듀서는 향후 실제 환자에게 이식되었을 때의 진동체 진동 성능을 예측하기 어려운 문제점이 있다. 본 연구에서는 제작된 플로팅 매스형 트랜스듀서에 대해 설계값과의 비교 평가 및 향후 컴퓨터 모델화된 청각 중이 집중 소자 모델에 적용이 가능하도록 기 제작된 진동체의 집중 소자 모델 파라미터들을 추정할 수 있는 방법을 제안하였으며, 제안된 방법을 LabVIEW 기반의 그래픽 유저 인터페이스 소프트웨어로 구현하였다. 제안된 방법은 실제 제작된 플로팅 매스형 진동체의 진동 변위 및 위상 데이터를 이용하여 해당 진동체의 집중 모델 파라미터들을 순차적 이차 프로그래밍 (SQP, sequential quadratic programming) 방법으로 추정하는 방식이다. 구현된 방법을 이용하여 측정 데이터에 가해지는 잡음의 양에 따른 플로팅 매스형 진동 트랜스듀서의 집중 모델 파라미터 추정 시의 발생 오차 변화를 컴퓨터 시뮬레이션을 통해 조사하여 본 방법의 파라미터 추정 정확도를 확인하였다. 또한, 실제로 제작한 인공중이용 진동 트랜스듀서에 대해 측정된 진동 변위 및 위상 데이터를 이용하여 진동체의 집중 모델 파라미터들을 추정하였으며, 기존 설계값들과 비교를 통해 제안된 방법의 유용성을 평가하였다.

생체 이식형 의료기기의 패키징을 위한 완전 밀폐 방법에 관한 연구 (A Study on the Hermetic Method for Packaging of Implantable Medical Device)

  • 박재순;김성일;김응보;강영환;조성환;정연호
    • 한국전기전자재료학회논문지
    • /
    • 제30권7호
    • /
    • pp.407-412
    • /
    • 2017
  • This paper introduces a biocompatible packaging system for implantable medical device having a hermetic sealing, such that a perfect physical and chemical isolation between electronic medical system and human body (including tissue, body fluids, etc.) is obtained. The hermetic packaging includes an electronic MEMS pressure sensor, power charging system, and bluetooth communication system to wirelessly measure variation of capacitance. The packaging was acquired by Quartz direct bonding and $CO_2$ laser welding, with a size of width $ 6cm{\times}length\;10cm{\times}lheight\;3cm$. Hermetic sealing of the packaged system was tested by changing the pressure in a hermetic chamber using a precision pressure controller, from atmospheric to 900 mmHg. We found that the packaged system retained the same count or capacitance values with sensor 1 - 25,500, sensor 2 - 26,000, and sensor 3 - 20,800, at atmospheric as well as 900 mmHg pressure for 5 hours. This result shows that the packaging method has perfect hermetic sealing in any environment of the human body pressure.

상태정보에 따른 체내삽입형 장치를 부착한 유-헬스케어 환자의 프라이버시 보호 프로토콜 (U-Healthcare user's privacy protection protocol with Implantable medical Device of State Information)

  • 정윤수;이상호
    • 한국통신학회논문지
    • /
    • 제37권4C호
    • /
    • pp.297-306
    • /
    • 2012
  • 최근 유헬스케어 시스템은 IT 기술과 의료서비스가 접목되면서 사용 범위가 점점 넓어지고 있다. 그러나 유헬스케어 시스템 중 체내삽입형 장치를 사용하는 환자의 경우, 환자의 프라이버시 예방과 안전한 접근 제어에 대한 대비책이 마련되어 있지 않아 그에 따른 프라이버시 보호 문제가 대두되고 있다. 본 논문에서는 체내삽입형 장치를 사용한 환자의 프라이버시를 보장하기 위해서 환자 정보를 가상화한 후 환자의 상태값과 수행값을 동기화함으로써 제3자의 불법적 접근을 예방할 수 있는 환자 프라이버시 보호 프로토콜을 제안한다. 제안된 프라이버시 보호 프로토콜은 사전에 관리 서버에 등록된 병원(의사, 간호사, 약국 등)의 권한정보에 따라 체내삽입형 장치를 부착한 환자의 개인정보의 열람범위를 제한하여 병원관계자의 불법적 업무 수행을 예방한다. 특히, 체내삽입형 장치와 게이트웨이 역할을 하는 가상장치는 접근 허가가 승인된 환자 정보 이외에 허가받지 않은 정보에 대해서 제 3자가 쉽게 접근하지 못하도록 환자의 상태값과 수행값을 동기화함으로써 환자의 프라이버시 관리의 효율성을 향상시키고 있다.

초소형 수동형 유체 압력 조정기 제작 및 실험 (Fabrication and Test of a Micro Passive Liquid Pressure Regulator)

  • 이기정;임인호;심우영;양상식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1482-1483
    • /
    • 2008
  • This report describes the design, fabrication and experimental results of an implantable micro pressure regulator. It consists of three silicon substrates, a glass substrate, and a PDMS layer. Silicon and glass substrates are fabricated by using bulk micro machining and sandblasting. The PDMS layer is used as a intermediate layer for Si-Si and Si-glass bonding processes. This micro regulator is a key component of the portable drug delivery systems for low power consumption. The device has some advantages, such as a passive type device, no power consumption, and simple structure.

  • PDF

다공성 폴리우레탄으로 피막된 Reservoir형 약물 조절 방출 시스템 (Controlled Release of Drugs from Reservoir Type Devices Coated with Porous Polyurethane Membranes)

  • 김길수;이승진
    • Journal of Pharmaceutical Investigation
    • /
    • 제23권4호
    • /
    • pp.207-211
    • /
    • 1993
  • Reservoir type devices were designed for long-term implantable drug delivery system. The reservoir type device was prepared with the polymethacrylic acid gel coated with polyurethane membrane. Release controlling agent (RCA) were employed to control drug release from devices via generation of micropores in the membranes. The polyurethane membrane functioned as a rate controlling barrier. The drug release pattern of hydrogel demonstrated zero order kinetics. The release rate of drugs could be regulated by varying hydrophobicity/hydrophilicity and content of the RCA, as well as the thickness of the polyurethane membrane. The release of drugs from this system was governed by pore mechanism via simple diffusion and osmotic pressure.

  • PDF