• Title/Summary/Keyword: Implantable

Search Result 310, Processing Time 0.033 seconds

A Simulation Study of Artificial Cochlea Based on Artificial Basilar Membrane for Improving the Performance of Frequency Separation (인공기저막 기반 인공와우의 주파수 분리 성능향상을 위한 인공기저막 전산모사)

  • Kim, Tae-In;Chang, Seong-Min;Song, Won-Joon;Bae, Sung-Jae;Kim, Wan-Doo;Cho, Maeng-Hyo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.4
    • /
    • pp.457-463
    • /
    • 2012
  • The basilar membrane (BM), one of organs of cochlea, has the specific positions of the maximum amplitude at each of related frequencies. This phenomenon is due to the geometry of BM. In this study, as the part of the research for the development of fully implantable artificial cochlea which is based on polymer membrane, parametric studies are performed to suggest the desirable artificial basilar membrane model which can detect wider range of frequency separation. The vibro-acoustic characteristics of the artificial basilar membrane are predicted through finite element analysis using commercial software Abaqus. Simulation results are verified by comparing with experimental results. Various geometric shapes of the BM and residual stress effects on the BM are investigated through the parametric study to enable a wider detectable frequency separation range.

Role of Reactive Oxygen Species in the Adipogenesis of Adipose-derived Stem Cells (지방유래줄기세포의 지방분화과정에서 활성산소가 미치는 영향)

  • Chang, Hak;Min, Kyung-Hee;Park, Young-In;Kim, Yo-Han;Minn, Kyung-Won
    • Archives of Plastic Surgery
    • /
    • v.38 no.2
    • /
    • pp.131-134
    • /
    • 2011
  • Purpose: Stem cells continue to receive research attention in the clinical fields, and adipose-derived stem cells (ADSCs) have been shown to be a good source raw material. Many plastic surgeons are researching the ADSC adipogenesis with a view of conducting clinical trials, and many attempts have been made to identify the factors that promote the adipogenesis of ADSCs, but comparatively few correlation studies have been undertaken to explore the relation between reactive oxygen species (ROS) and the ADSC adipogenesis. We undertook this study is to investigate the effects of ROS on ADSC adipogenesis. Methods: ADSCs were isolated and cultured from abdominal adipose tissue, and cultured in different media; 1) DMEM(control), 2) adipogenesis induction culture medium, 3) adipogenesis induction culture medium with ROS ($20{\mu}M/50{\mu}M\;H_2O_2$), 4) adipogenesis induction culture medium containing ROS ($20{\mu}M/50{\mu}M\;H_2O_2$) and antioxidant ($10{\mu}M/20{\mu}M$ Deferoxamine). We compared adipogenesis in these different media by taking absorbance measurements after Oil-Red O staining every 5 days. Results: After culturing for 20 days, significant differences were observed between these various culture groups. Absorbance results showed significantly more adipogenesis had occurred in media containing adipogenesis induction culture medium and $H_2O_2$ (in a $H_2O_2$ dose-dependently manner) than in media containing adipogenesis induction culture medium and no $H_2O_2$ (p<0.001). Furthermore, in media containing adipogenesis induction culture medium, $H_2O_2$, and antioxidant, absorbance results were significantly lower than in adipogenesis induction culture medium and $H_2O_2$ (p<0.001). Conclusion: These findings suggest that ROS promote the adipogenesis of ADSCs. We suggests that ROS could be used in the adipose tissue engineering to improve fat cell differentiation and implantable fat tissue organization.

A New Method for Enhancement of Right-Left Pump Output Balance in the Totally Implantable Artificial Heart (완전이식형 인공심장의 좌,우 심박출량 균형의 개선에 관한 연구)

  • Choe, Won-U;Kim, Hui-Chan;Kim, Won-Gon;No, Jun-Ryang;Kim, In-Yeong;Min, Byeong-Gu
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.385-391
    • /
    • 1998
  • A new balancing method of atrial pressures balancing for the moving actuator total artificial heart(TAH) without an extra compliance chamber was developed. The asymmetric operation of the pendulous moving actuator have made it possible to compensate the left and right pump output difference by utilizing the interventricular air space as an internal compliance chamber in a pump housing. Furthermore, the balancing performance between left and right pump outputs is increased through the improvement of the flexibility of part of the polyurethane housing. However, the increase of the flexibility of the pump housing causes a little loss of the cardiac output due to the reduction of active filling property. In this paper., a good condition between the balance and pump output performance is evaluated by adjusting the air volume in the interventricular space through a series of in vitro experiments. This new pump was implanted in a sheep weighting 63kg, and it survived for 3 days and the average cardiac output during postoperative days was about 4.2 L/mim with the atrial pressures under 15 mmHg.

  • PDF

Characteristics of BCNU-loaded PLGA Wafers (BCNU를 함유한 생분해성 PLGA 웨이퍼의 특성분석)

  • 안태군;강희정;이진수;성하수;정제교
    • Polymer(Korea)
    • /
    • v.26 no.5
    • /
    • pp.691-700
    • /
    • 2002
  • Interstitial therapy using biodegradable polymeric device loaded with anticancer agent can deliver the drug to the tumor site at high concentration, resulting in an increase of therapeutic efficacy. 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU, carmustine) is most commonly used as chemotherapeutic agent for brain tumors. The design of implantable device is regarded as an important factor lot the efficient delivery of antitumor agent to targeting site. In order to control the release profile of drug, the release pattern of BCNU with the changes of various dimension and additives was investigated. The PLGA wafers containing 3.85, 10, 20 and 30% of BCNU were prepared in various shape (diameter of 3, 5 and 10 mm, thickness of 0.5, 1 and 2 mm) by direct compression method. In vitro drug release profile of BCNU-loaded PLGA wafers could be controlled by changing the dimension of wafers such as initial drug content, weight, diameter, thickness, volume and surface area of wafers, as well as PLGA molecular weight and additives. Drug release from BCNU-loaded PLGA wafers was facilitated with an increase of BCNU-loading amount or presence of poly(N-vinylpyrrolidone)(PVP) or sodium chloride (NaCl). The effects of various geometric factors and additives on the BCNU release pattern were confirmed by the investigation of mass loss and morphology of BCNU-loaded PLGA wafers.

Respiratory Assist by Use of Electrical Diaphragmatic Pacing (전기자극에 의한 횡격막 조율을 이용한 호흡보조장치)

  • 오중환;김은기;서재정;박일환;김부연;이상헌;이종국;이영희
    • Journal of Chest Surgery
    • /
    • v.34 no.6
    • /
    • pp.441-446
    • /
    • 2001
  • Background: Electrical breathing pacing has many advantages over mechanical ventilation. However, clinically permanent diaphragmatic pacing has been applied to limited patients and few temporary pacing has been reported. Our purpose is to investigate the feasibility of temporary electrical diaphragm pacing in explothoracotomy canine cases. Methods: Five dogs were studied under the general anesthesia. Left 5th intercostal space was opened. Self designed temporary pacing leads were placed around the left phrenic nerve and connected to the myostimulator. Chest wall was closed after tube insertion with underwater drainage. Millar catheter was introduced to the aorta and right atrium. Swan-Ganz catheter was introduced to the pulmonary artery. When the self respiration was shallow with deep anesthesia, hemodynamic and tidal volume were measured with the stimulator on. Results: Tidal volume increased from 143.3$\pm$51.3 ml to 272.3$\pm$87.4 ml(p=0.004). Right atrial diastolic pressure decreased from 0.7$\pm$4.0 mmHg to -10.5$\pm$4.7 mmHg(p=0.005). Pulmonary arterial diastolic pressure decreased from 6.1+2.5 mmHg to 1.2$\pm$4.8 mmHg(p<0.001). The height of water level in chest tube to show intrathoracic pressure change was from 10.3$\pm$6.7cmH$_{2}$O to 20.0$\pm$5.3 cmH$_{2}$O. Conclusion: Temporary electrical diaphragmatic pacing is a simple method to assist respiration in explothoracotomy canine cases. Self designed pacing lead is implantable and removable. Negative pressure ventilation has favorable effects on the circulatory system. Therefore, clinical application of temporary breathing pacing is feasible in thoracotomy patients to assist cardiorespiratory function.

  • PDF

Study on the Piezoelectric Energy Harvesting Technology for the Energy Conversion of Vibration in Automobiles (자동차 진동 에너지 변환을 위한 압전 에너지 하베스팅에 관한 연구)

  • Lee, Hyeon Yeong;Kim, Kwangwon;Ye, Jiwon;Woo, Suhyeon;Lee, Geon;Lee, Seungah;Jeong, Seong Rok;Jeong, Seon Hye;Kim, Ho Seong;Nam, Ga Hyeon;Jo, Yun Yeong;Choi, Han Seung;Ryu, Jungho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.6
    • /
    • pp.495-504
    • /
    • 2021
  • Energy Harvesting is a technology that can convert wasted energy such as vibration, heat, light, electromagnetic energy, etc. into usable electrical energy. Among them, vibration-based piezoelectric energy harvesting (PEH) has high energy conversion efficiency with a small volume; thus, it is expected to be used in various autonomous powering devices, such as implantable medical devices, wearable devices, and energy harvesting from road or automobiles. In this study, wasted vibration energy in an automobile is converted into electrical energy by high-power piezoelectric materials, and the generated electrical energy is found to be an auxiliary power source for the operation of wireless sensor nodes, LEDs, etc. inside an automobile. In order to properly install the PEH in an automobile, vibration characteristics includes frequency and amplitude at several positions in the automobile is monitored initially and the cantilever structured PEH was designed accordingly. The harvesting properties of fabricated PEH is characterized and installed into the engine part of the automobile, where the vibration amplitude is stable and strong. The feasibility of PEH is confirmed by operating electric components (LEDs) that can be used in practice.

The effect of plasma treatment to improve adhesion strength of parylene-C coated medical grade SUS304 (Parylene-C 코팅된 의료용 SUS304 소재의 결합력 향상을 위한 플라즈마 처리 효과)

  • Kim, Dong-Guk;Song, Tae-Ha;Jeong, Yong-Hoon;Kang, Kwan-Su;Yoon, Deok-kyu;Kim, Min-Uk;Woo, Young-Jae;Seo, Yo-Han;Kim, Kyung-Ah;Roh, Ji-hyoung
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.6
    • /
    • pp.390-397
    • /
    • 2022
  • Parylene-C which was mainly used for industries such as electronics, machinery and semiconductors has recently been in the spotlight in the medical field due to its properties such as corrosion resistance and biocompatibility. In this study we intend to derive a plan to improve the bonding strength of Parylene-C coating with the SUS304 base material for medical use which can be applied to various medical fields such as needles, micro needles and in vitro diagnostic device sensors. Through plasma pretreatment the bonding strength between Parylene-C and metal materials was improved. It was confirmed that the coated surface was hydrophobic by measuring the contact angle and the improvement of the surface roughness of the sample manufactured through CNC machining was confirmed by measuring the surface roughness with SEM. Through the above results, it is thought that it will be effective in increasing usability and reducing pain in patients by minimizing friction when inserting medical devices and in contact with skin. In addition it can be applied to various application fields such as human implantable stents and catheters, and is expected to improve the performance and lifespan of medical parts.

Impact of a Multidisciplinary Team Approach on Extracorporeal Circulatory Life Support-Bridged Heart Transplantation

  • Lee, Jae Jun;Kim, Young Su;Chung, Suryeun;Jeong, Dong Seop;Yang, Ji-Hyuk;Sung, Kiick;Kim, Wook Sung;Jun, Tae-Gook;Cho, Yang Hyun
    • Journal of Chest Surgery
    • /
    • v.54 no.2
    • /
    • pp.99-105
    • /
    • 2021
  • Background: The number of heart transplantations (HTx) is increasing annually. Due to advances in medical and surgical support, the outcomes of HTx are also improving. Extracorporeal circulatory life support (ECLS) provides patients with decompensated heart failure a chance to undergo HTx. A medical approach involving collaboration among experienced experts in different fields should improve the outcomes and prognosis of ECLS-bridged HTx. Methods: From December 2003 to December 2018, 1,465 patients received ECLS at Samsung Medical Center. We excluded patients who had not undergone HTx or underwent repeated transplantations. Patients younger than 18 years were excluded. We also excluded patients who received an implantable durable left ventricular assist device before HTx. In total, 91 patients were included in this study. A multidisciplinary team approach began in March 2013 at our hospital. We divided the patients into 2 groups depending on whether they were treated before or after implementation of the team approach. Results: The 30-day mortality rate was significantly higher in the pre-ECLS team group than in the post-ECLS team group (n=5, 18.5% vs. n=2, 3.1%; p=0.023). The 1-year survival rate was better in the post-ECLS team group than in the pre-ECLS team group (n=57, 89.1% vs. n=19, 70.4%; p=0.023). Conclusion: We found that implementing a multidisciplinary team approach improved the outcomes of ECLS-bridged HTx. Team-based care should be adapted at HTx centers that perform high-risk HTx.

Feasibility of the Threshold-Based Quantification of Myocardial Fibrosis on Cardiac CT as a Prognostic Marker in Nonischemic Dilated Cardiomyopathy

  • Na Young Kim;Dong Jin Im;Yoo Jin Hong;Byoung Wook Choi;Seok-Min Kang;Jong-Chan Youn;Hye-Jeong Lee
    • Korean Journal of Radiology
    • /
    • v.25 no.6
    • /
    • pp.540-549
    • /
    • 2024
  • Objective: This study investigated the feasibility and prognostic relevance of threshold-based quantification of myocardial delayed enhancement (MDE) on CT in patients with nonischemic dilated cardiomyopathy (NIDCM). Materials and Methods: Forty-three patients with NIDCM (59.3 ± 17.1 years; 21 male) were included in the study and underwent cardiac CT and MRI. MDE was quantified manually and with a threshold-based quantification method using cutoffs of 2, 3, and 4 standard deviations (SDs) on three sets of CT images (100 kVp, 120 kVp, and 70 keV). Interobserver agreement in MDE quantification was assessed using the intraclass correlation coefficient (ICC). Agreement between CT and MRI was evaluated using the Bland-Altman method and the concordance correlation coefficient (CCC). Patients were followed up for the subsequent occurrence of the primary composite outcome, including cardiac death, heart transplantation, heart failure hospitalization, or appropriate use of an implantable cardioverter-defibrillator. The Kaplan-Meier method was used to estimate event-free survival according to MDE levels. Results: Late gadolinium enhancement (LGE) was observed in 29 patients (67%, 29/43), and the mean LGE found with the 5-SD threshold was 4.1% ± 3.6%. The 4-SD threshold on 70-keV CT showed excellent interobserver agreement (ICC = 0.810) and the highest concordance with MRI (CCC = 0.803). This method also yielded the smallest bias with the narrowest range of 95% limits of agreement compared to MRI (bias, -0.119%; 95% limits of agreement, -4.216% to 3.978%). During a median follow-up of 1625 days (interquartile range, 712-1430 days), 10 patients (23%, 10/43) experienced the primary composite outcome. Event-free survival significantly differed between risk subgroups divided by the optimal MDE cutoff of 4.3% (log-rank P = 0.005). Conclusion: The 4-SD threshold on 70-keV monochromatic CT yielded results comparable to those of MRI for quantifying MDE as a marker of myocardial fibrosis, which showed prognostic value in patients with NIDCM.

Human Lung Cancer Cell Xenografts Implanted under the Capsule of Kidney, Spleen and Liver (폐암 세포주를 사용한 신, 비장 및 간 피막하 분식법의 비교)

  • 김수현;김종인;이해영;조봉균;박성달;김송명
    • Journal of Chest Surgery
    • /
    • v.36 no.10
    • /
    • pp.711-720
    • /
    • 2003
  • Bakground : Complete resection by the surgery has been selected as the treatment of choice in lung cancer patients, but in cases of recurrence after excision or inoperable cases, the importance of anticancer chemotherapy has been emphasized. If one can select a set of the sensitive chemotherapeutic agents before anticancer chemotherapy, it will give more favourable results. Subrenal capsular assay has been recognized as a useful in-vivo chemosensitivity test of thoracic and abdominal tumors and it can be done in a short time for a rapid interpretation of tumor responsiveness to anticancer chemotherapeutic drugs. It has been reported that various kinds of cancer cells can be implantable to the kidney, but so far there is no comparative study of xenogeneic cell implantation on liver, spleen and kidney. The author implanted the human lung cancer cells under the capsule of S.D rat's liver, spleen and kidney respectively and compared the pattern of growth and histology. Material and Method: After incubation of human lung cancer cell line (SW-900 G IV) in RPMI 1640 (Leibovitz L-15 medium) culture media, 3${\times}$3${\times}$3 mm size fibrin clots which contain 108 cancer cells were made. Thereafter the fibrin clots were implanted at subcapsule area of liver, spleen and kidney of S.D. female rat. For immune suppression, cyclosporin-A (80 mg/Kg) was injected subcutaneously daily from post-implantation first day to sixth day. The body weight was measured at pre and post implantation periods. The growth pattern and the size of tumor mass were observed and the pathologic examination and serum tumor marker tests were performed. Result: Body weight increased in both of control and experimental groups. Serum Cyfra 21-1 was not detected. Serum levels of CEA and NSE revealed no significant change. The SCC-Ag increased significantly in implanted group. The growth rate of human lung cancer cells which was implanted on spleen was higher than on liver or kidney. The surface area, thickness, and volume of tumor mass were predominant at spleen. The success rates of implantation were 80% on kidney, 76.7% on spleen and 43.3% on liver. Pathologic examination of implanted tumors showed characteristic findings according to different organs. Tumors that were implanted on kidney grew in a round shape, small and regular pattern. In the spleen, tumors grew well and microscopic neovascularization and tumor thrombi were also found, but the growth pattern was irregular representing frequent daughter mass. Human lung cancer cells that were implanted in the liver, invaded to the liver parenchyme, and had low success rate of implantation. Microscopically, coagulation necrosis and myxoid fibrous lesion were observed. Conclusion: The success rate of implantation was highest in the kidney. And the mass revealed regular growth that could be measured easily. The SCC-Ag was presented earlier than CEA or Cyfra21-1. The Cyfra21-1 was not detected at early time after implantation. The best model for tumor implantation experiment for chemosensitivity test was subrenal capsular analysis than liver and spleen and the useful serum tumor marker in early period of implantation was the SCC-Ag.