• 제목/요약/키워드: Implant-supported fixed-prosthesis

검색결과 136건 처리시간 0.02초

A STRAIN GAUGE ANALYSIS OF IMPLANT-SUPPORTED CANTILEVERED FIXED PROSTHESIS UNDER DISTAL STATIC LOAD

  • Sohn, Byoung-Sup;Heo, Seong-Joo;Chang, Ik-Tae;Koak, Jai-Young;Kim, Seong-Kyun
    • 대한치과보철학회지
    • /
    • 제45권6호
    • /
    • pp.717-723
    • /
    • 2007
  • Statement of problem. Unreasonable distal cantilevered implant-supported prosthesis can mask functional problems of reconstruction temporarily, but it can cause serious strain and stress around its supported implant and surrounding alveolar bone. Purpose. The purpose of this study was to evaluate strain of implants supporting distal cantilevered fixed prosthesis with two different cantilevered length under distal cantilevered static load. Material and methods. A partially edentulous mandibular test model was fabricated with auto-polymerizing resin (POLYUROCK; Metalor technologies, Stuttgart, Swiss) and artificial denture teeth (Endura; Shofu inc., Kyoto, Japan). Two implants-supported 5-unit screw-retained cantilevered fixed prosthesis was made using standard methods with Type III gold alloy (Harmony C&B55; Ivoclar-vivadent, Liechtenstein, Germany) for superstructure and reinforced hard resin (Tescera; Ivoclar-vivadent, Liechtenstein, Germany) for occlusal material. Two strain gauges (KFG-1-120-C1-11L1M2R; KYOWA electronic instruments, Tokyo, Japan) were then attached to the mesial and the distal surface of each standard abutment with adhesive (M-bond 200; Tokuyama, Tokyo, Japan). Total four strain gauges were attached to test model and connected to dynamic signal conditioning strain amplifier (CTA1000; Curiotech inc., Paju, Korea). The stepped $20{\sim}100$ N in 25 N increments, cantilevered static load 8mm apart (Group I) or 16mm apart (Group II), were applied using digital push-pull gauge (Push-Pull Scale & Digital Force Gauge, Axis inc., Seoul, Korea). Each step was performed ten times and every strain signal was monitored and recorded. Results. In case of Group I, the strain values were surveyed by $80.7{\sim}353.8{\mu}m$ in Ch1, $7.5{\sim}47.9{\mu}m/m$ in Ch2, $45.7{\sim}278.6{\mu}m/m$ in Ch3 and $-212.2{\sim}718.7{\mu}m/m$ in Ch4 depending on increasing cantilevered static load. On the other hand, the strain values of Group II were surveyed by $149.9{\sim}612.8{\mu}m/m$ in Ch1, $26.0{\sim}168.5{\mu}m/m$ in Ch2, $114.3{\sim}632.3{\mu}m/m$ in Ch3, and $-323.2{\sim}-894.7{\mu}m/m$ in Ch4. Conclusion. A comparative statistical analysis using paired sample t-test about Group I Vs Group II under distal cantilevered load shows that there are statistical significant differences for all 4 channels (P<0.05).

상악의 임플란트 고정성 보철물과 후방연장 국소의치를 이용하여 수복한 10년 경과 관찰 증례 (Maxillary implant-supported fixed prosthesis engaged by distal-extension removable partial denture for 10 years: a case report)

  • 류리;박연희;오원석;이정진;박주미
    • 구강회복응용과학지
    • /
    • 제36권2호
    • /
    • pp.121-127
    • /
    • 2020
  • 상악 무치악 환자에서 치료 방법을 결정하는데 있어 생역학적 고려사항과 함께 전치부 치아에 대한 환자의 심미적 요구도 고려될 수 있다. 이 증례 보고는 전치부의 임플란트 고정성 보철물과 구치부의 후방 연장 가철성 국소의치로 구강 기능이 회복된 상악 무치악 환자의 10년 동안 임상 결과를 기술하고 있다. 상악 전방에 임플란트 고정성 보철물로 4개의 임플란트를 연결고정 하였으며 후방에 가공선 유지장치를 가진 가철성 국소의치가 장착되었다. 하악 무치악은 임플란트 피개의치로 수복되었다. 경과 관찰 기간 동안 고정성 보철물의 인공치아와 전장 레진의 변색, 사고로 인한 보철물 파절 이외에 임플란트 및 국소의치 관련된 기계적, 기계적 생물학적 주요 합병증은 관찰되지 않았다.

상하악 완전 무치악 환자에서 임시 보철물 스캔을 이용한 일체형 임플란트 지지 고정성 보철물 수복 증례 (Fabrication of definitive complete-arch implant-supported fixed prosthesis in upper and lower completely edentulous patient using temporary prosthesis scan: a case report)

  • 정승미;손현락;최강덕;최병호
    • 대한치과보철학회지
    • /
    • 제62권3호
    • /
    • pp.243-252
    • /
    • 2024
  • 상하악 완전 무치악 환자에서 임플란트 지지 고정성 최종 보철물을 제작할 때 환자의 수직 고경, 악간관계, 구강내에 식립된 임플란트와 임플란트에 연결된 지대주, 그리고 잇몸 형태에 관한 정확한 정보의 체득이 중요하다. 본 증례에서는 임시 보철물을 통해서 이러한 정보들을 채득하여 최종 보철물을 제작하였다. 임시 보철물을 구강 밖에서 스캔하여 스캔의 효율성을 높였고, 스캔 때 임시 보철물의 양측 후방 부위를 연결하는 스캔지그를 사용하여 스캔의 정밀도를 향상시켰다. 본 증례에서는 이와 같은 디지털 기술을 활용하여 심미적, 기능적으로 만족할 만한 임상적 결과를 얻었기에 이를 보고하는 바이다.

레이저 적층 제조 기술을 이용한 상악 무치악 환자의 임플란트 고정성 보철 수복 증례 (Implant-supported prosthetic rehabilitation for the edentulous maxilla using the additive manufacturing technology: A case report)

  • 김희경
    • 대한치과보철학회지
    • /
    • 제56권2호
    • /
    • pp.173-178
    • /
    • 2018
  • 직접식 금속 레이저 소결 방식 시스템은 기공 오차 및 주조 결함 없이 제작 비용 및 제조 시간 단축을 장점으로 전악 임플란트 지지 고정성 보철물 제작에 유용하다. 본 증례에서는 직접식 금속 레이저 소결 방식과 치과용 캐드캠으로 제작된 단일구조 지르코니아 크라운을 사용하여 무치악 상악에서 임플란트 지지 고정성 치과 보철물의 성공적인 결과를 보고하고 임상적 의의를 평가하였다. 51세의 건강한 중년 여성이 상악 전 치아의 동요도를 주소로 서울대학교 치과병원에 내원하였다. 모든 상악 치아 발치 후 직접식 금속 레이저 소결 기술 및 캐드캠 단일구조 지르코니아 크라운을 사용하여 코발트-크롬 프레임을 포함하는 임플란트 지지 고정성 치과 보철물을 제작하였다. 최종 수복물 장착 6개월 후, 기계적 및 생물학적 합병증은 발견되지 않았고 보철물은 기능 및 심미적으로 만족스러운 결과를 보였다. 직접식 금속 레이저 소결 시스템을 이용하여 추가적인 기공 작업 없이 임플란트 지지 고정성 보철물을 제작하여 제조 시간을 단축하고 신뢰할 수 있는 정확도와 적합성을 얻었다.

상악 전부 무치악 환자에서 CAD/CAM 시스템으로 제작되는 Pd-Ag 합금을 이용한 고정성 임플란트 전악 수복 증례 (Maxillary cement retained implant supported fixed prosthesis using the millingable Pd-Ag alloy generated by CAD/CAM system: clinical report after two years in service)

  • 이준식;한세진;최유성
    • 구강회복응용과학지
    • /
    • 제30권1호
    • /
    • pp.71-80
    • /
    • 2014
  • 골흡수가 심한 환자에서 임플란트를 이용한 전악 수복의 경우 치은과 치아의 외형을 심미적이면서도 기능적으로 회복하기 위해서는 보철물 제작에 있어 신중을 기해야 한다. 이러한 전악 수복 증례에서 CAD/CAM 시스템이 높은 정확성을 가지는 보철물 제작을 가능하게 함으로써 사용이 증가하고 있다. 최근에 임상에서 티타늄이나 지르코니아의 단점을 보완하면서 높은 생체적합성을 가지고 CAD/CAM 시스템으로 제작할 수 있는 팔라듐-은(Pd-Ag) 합금이 개발되어 사용되고 있다. 본 증례에서는 상악 전부 무치악 환자에서 임플란트를 식립하고 도재의 chipping이나 파절의 위험을 감소시키기 위해 Pd-Ag 합금을 이용해 제작된 임플란트 고정성 보철물로 수복한 환자에 대해 보고하고자 한다.

부분 무치악의 고정성 임플랜트 보철의 저위교합에 관한 3차원 유한요소법적 연구 (3-DIMENSIONAL FINITE ELEMENT ANALYSIS ON THE INFRAOCCLUSION OF FIXED IMPLANT PROSTHESIS FOR PARTIAL EDENTULISM)

  • 김인섭;최충국;정재헌
    • 대한치과보철학회지
    • /
    • 제34권3호
    • /
    • pp.632-649
    • /
    • 1996
  • The purpose of this study was to examine, by the method of 3-dimentional finite element analysis. how infraocclusion affected the stress distribution in surrounding bone and osseointegrated prosthesis. The 3-dimentional finite element mandibular models were made, in which the first and second molars were removed and the two osseointegrated implants were placed in the first and second molar sites and implant supported fixed prostheses were constructed. Analysis of equivalent stress and displacement induced by strong occlusion or infraocclusion was performed under vertical or inclined distributed loads. The results were as follows; 1. Under vertical load of 50N or 500N, the model in which infraocclusion had not been allowed showed greater stress on implants and the supporting bone than on natural teeth. 2. In the model in which infraocclusion of $30{\mu}m$ had been allowed, implant-prosthesis on the molars had no contact with opposing teeth under vertical load of 50N, However with the same allowed infraocclusion and the model under vertical load of 500N, implant prosthesis on the second molar had contact with opposing teeth, and stress distribution occured properly on natural teeth and implants. 3. Under $45^{\circ}$ inclined load, the model in which infraocclusion had not been allowed showed greater stress on implants and the supporting bone than on natural teeth. There was greater stress in the case of $45^{\circ}$ inclined load than in the case of vertical load. 4. Under $45^{\circ}$ inclined load of 50N or 500N, the model in which infraocclusion of $30{\mu}m$, had been allowed showed no occlusal contact on the implants and occlusal contact on the natural teeth. 5. In partially edentulous cases with implant supported prosthesis, we can prevent excessive load on implants by allowing infraocclusion.

  • PDF

밀링 및 3D 프린팅 방법으로 제작된 임플란트 보철물을 이용한 심한 우식 환자의 완전 구강 회복 증례 (Full mouth rehabilitation of patient with severe dental caries with implant fixed prosthesis fabricated with milling and 3D printing method: A case report)

  • 김태윤;이준석;홍성진;김형섭;권긍록
    • 대한치과보철학회지
    • /
    • 제57권3호
    • /
    • pp.288-295
    • /
    • 2019
  • 임플란트 지지 보철물의 'passive fit'은 보철물의 장기적인 성공과 합병증의 최소화에 핵심적인 요소이다. 그리고 이 요소는 보철물의 제작과정에 의해 대부분 결정된다. 전통적인 주조 방식은 금속의 수축 변형이 발생하여 광범위한 임플란트 보철물에 적용하는데 제한이 있었다. 그러나 Computer-aided design/Computer-aided manufacture (CAD/CAM) 밀링 방식과 3D 프린팅 방식을 사용하면 이러한 한계점을 극복할 수 있다. 본 증례는 광범위한 임플란트 보철물을 사용한 완전 구강 회복 증례이다. 가철성 임시 보철물을 제작하여 심미와 기증을 평가하고 임플란트 식립을 위한 가이드로 사용하였다. 임플란트 식립 후, 임플란트 고정성 임시 보철물이 장착되었다. 추가적인 평가와 조정 후, 최종 보철물이 CAD를 사용하여 설계되었고, CAM을 사용하여 제작되었다. 전치부 임플란트의 나사 유지형 상부구조물은 밀링되어 제작되었고, 전치부 및 구치부 금속도재관의 금속구조물은 3D 프린팅되어 제작되었다. 보철물은 양호한 적합도를 보였고 술자와 환자 모두 증례의 최종 결과에 심미적, 기능적으로 만족하였다.

Finite element analysis in static and dynamic behaviors of dental prosthesis

  • Djebbar, N.;Serier, B.;Bouiadjra, B. Bachir
    • Structural Engineering and Mechanics
    • /
    • 제55권1호
    • /
    • pp.65-78
    • /
    • 2015
  • In recent years, implants have gained growing importance in all areas of medicine. The success of the treatment depends on many factors affecting the bone-implant, implant-abutment and abutment-prosthesis interfaces. In this paper, static and dynamic behaviors of the dental prosthesis are investigated. Three-dimensional finite element models of dental prosthesis were constructed. Dynamic loads in 5 sec applied on occlusal surface. Therefore, FEA was selected for use in this study to examine the effect of the static and dynamic loads on the stress distribution for an implant-supported fixed partial denture and supporting bone tissue.

임플란트 지지 나사-시멘트 유지형 보철물에서 보철물-지대주 제거 후 변연부 연마의 효과: 증례보고 (Burnishing effect on marginal misfit of implant-supported screw-and-cement retained prostheses: A case report)

  • 김미주;이두형
    • 대한치과보철학회지
    • /
    • 제58권3호
    • /
    • pp.239-243
    • /
    • 2020
  • 고정성 보철물의 변연 적합도가 낮은 경우 치태침착, 치주질환, 치아과민, 보철물 구성요소 파절, 시멘트 상실 등의 생물학적, 기계적 합병증이 발생할 가능성이 증가할 수 있다. 이러한 합병증은 보철물의 장기간의 성공과 생존에 영향을 미친다. 본 증례는 임플란트 지지 나사-시멘트 유지형 보철물에서 보철물 장착 시 보철물-지대주를 제거하고 변연부를 연마하여 변연간극을 최소화할 수 있는 임상과정을 보여준다. 그리고 변연 간극을 연마 전과 후에 측정하여 비교 관찰하였다. 본 기술은 변연 적합도를 높여 보철물의 수명 연장에 기여할 수 있다.

Comparative evaluation of peri-implant stress distribution in implant protected occlusion and cuspally loaded occlusion on a 3 unit implant supported fixed partial denture: A 3D finite element analysis study

  • Acharya, Paramba Hitendrabhai;Patel, Vilas Valjibhai;Duseja, Sareen Subhash;Chauhan, Vishal Rajendrabhai
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권2호
    • /
    • pp.79-88
    • /
    • 2021
  • Purpose. To assess peri-implant stress distribution using finite element analysis in implant supported fixed partial denture with occlusal schemes of cuspally loaded occlusion and implant protected occlusion. Materials and methods. A 3-D finite element model of mandible with D2 bone with partially edentulism with unilateral distal extension was made. Two Ti alloy identical implants with 4.2 mm diameter and 10 mm length were placed in the mandibular second premolar and the mandibular second molar region and prosthesis was given with the mandibular first molar pontic. Vertical load of 100 N and and oblique load of 70 N was applied on occlusal surface of prosthesis. Group 1 was cuspally loaded occlusion with total 8 contact points and Group 2 was implant protected occlusion with 3 contact points. Results. In Group 1 for vertical load, maximum stress was generated over implant having 14.3552 Mpa. While for oblique load, overall stress generated was 28.0732 Mpa. In Group 2 for vertical load, maximum stress was generated over crown and overall stress was 16.7682 Mpa. But for oblique load, crown stress and overall stress was maximum 22.7561 Mpa. When Group 1 is compared to Group 2, harmful oblique load caused maximum overall stress 28.0732 Mpa in Group 1. Conclusion. In Group 1, vertical load generated high implant stress, and oblique load generated high overall stresses, cortical stresses and crown stresses compared to vertical load. In Group 2, oblique load generated more overall stresses, cortical stresses, and crown stresses compared to vertical load. Implant protected occlusion generated lesser harmful oblique implant, crown, bone and overall stresses compared to cuspally loaded occlusion.