• 제목/요약/키워드: Implant-abutment

검색결과 504건 처리시간 0.022초

임플란트 고정체의 나사산 형태와 하중조건에 따른 응력분석 (Finite Element Stress Analysis of the Implant Fixture According to the Thread Configuration and the Loading Condition)

  • 안옥주;정제옥;김창현;강동완
    • 구강회복응용과학지
    • /
    • 제21권2호
    • /
    • pp.153-167
    • /
    • 2005
  • The purpose of this study was to compare the v-shape thread with the square shape thread of fixture in the view of stress distribution pattern using finite element stress analysis. The finite element model was designed with the parallel placement of two standard fixtures(4.0 mm diameter ${\times}$ 11.5 mm length) on the region of mandibular 1st and 2nd molars. Three dimensional finite element model was created with the components of the implant and surrounding bone. This study simulated loads of 200 N at the central fossa in a axial direction (load A), 200 N at the buccal offset load that is 2 mm apart from central fossa in a axial direction (load B), 200 N at the buccal offset load that was 4 mm apart from central fossa in a axial direction (load C). These forces of load A',B',C' were applied to a $15^{\circ}$ inward oblique direction at that same site with 200 N. Von Mises stress values were recorded and compared in the supporting bone, fixture, and abutment screw. The following results have been made based on this study : 1. The highest stress concentration occurred at the cervical region of the implant fixture. 2. Von Mises stress value of off-site region was higher than that of central fossa region. 3. Square shape thread type showed more even stress distribution in the vertical and oblique force than V-shape thread type. 4. Stress distribution was the most effective in the case of buccal offset load (2, 4 mm distance from central fossa) in the square shape thread type. 5. V-shape thread type revealed higher von Mises stress value than square shape thread type in all environmental condition. The results from numerical analyses concluded that square shape thread type had the lower destructive stress and more stress distribution between the fixture and bone interface than V-shape thread type. Therefore, square shape thread type was regarded as optimal thread configuration in biomechanical concepts.

3본 나사 유지형 임플란트 보철물의 고정 방식에 따른 임플란트 고정체 치경부에 발생하는 변형율 비교분석 (Analysis of implant strain value exerted using different screw tightening protocols in screw-retained 3-unit prostheses)

  • 김상범;이두형;이청희
    • 대한치과보철학회지
    • /
    • 제58권4호
    • /
    • pp.321-327
    • /
    • 2020
  • 목적: 본 연구의 목적은 3본 나사 유지형 임플란트 보철물의 나사 고정 방식에 따른 치경부에 발생하는 변형율을 측정하고 비교하기 위함이다. 재료 및 방법: 2가지 종류의 임플란트(외부연결방식, 내부연결방식)를 각각 2개씩 4개 임플란트 고정체 경부에 스트레인 게이지를 부착한 후, 각 종류의 아크릴릭 레진 모형 2개를 제작하였다. CAD-CAM을 이용하여 hex 및 nonhex 지대주를 제작하였고,(EH, ENH, IH& INH 군) 나사-시멘트 유지보철 개념으로 보철물을 비귀금속으로 제작하였다. 각 지대주를 10 Ncm 토크로 고정한 후, 보철물을 합착하였다. 나사를 3가지의 다른 방법으로 30 Ncm까지 고정한 다음, 5분 후 변형율을 측정한 후 평균비교 및 군간 상호작용을 평가하였다 (α = .05). 결과: 외부연결방식 군은 내부연결방식 군에 비하여 유의하게 낮은 변형율을 나타냈으며, EH군이 ENH군보다 유의하게 낮은 변형율을 나타내었으나 (P < .05), 나사 고정 방법에 따른 차이는 없었다 (P > .05). IH군이 INH군에 비하여 유의하게 높은 변형율을 나타내었으며 IH군에서만 나사 고정 방법에 따라서도 차이가 있었다 (P < .05). 결론: 나사 유지형 임플란트 보철물에서는 외부연결방식인 경우에는 큰 영향이 없으나, 내부연결방식에서는 보다 큰 변형율이 발생하고 나사 고정 방법도 영향을 주는 것으로 나타났다.

Effect of laser-dimpled titanium surfaces on attachment of epithelial-like cells and fibroblasts

  • Lee, Dong-Woon;Kim, Jae-Gu;Kim, Meyoung-Kon;Ansari, Sahar;Moshaverinia, Alireza;Choi, Seong-Ho;Ryu, Jae-Jun
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권2호
    • /
    • pp.138-145
    • /
    • 2015
  • PURPOSE. The objective of this study was to conduct an in vitro comparative evaluation of polished and laser-dimpled titanium (Ti) surfaces to determine whether either surface has an advantage in promoting the attachment of epithelial-like cells and fibroblast to Ti. MATERIALS AND METHODS. Forty-eight coin-shaped samples of commercially pure, grade 4 Ti plates were used in this study. These discs were cleaned to a surface roughness (Ra: roughness centerline average) of 180 nm by polishing and were divided into three groups: SM (n=16) had no dimples and served as the control, SM15 (n=16) had $5-{\mu}m$ dimples at $10-{\mu}m$ intervals, and SM30 (n=16) had $5-{\mu}m$ dimples at $25-{\mu}m$ intervals in a $2{\times}4mm^2$ area at the center of the disc. Human gingival squamous cell carcinoma cells (YD-38) and human lung fibroblasts (MRC-5) were cultured and used in cell proliferation assays, adhesion assays, immunofluorescent staining of adhesion proteins, and morphological analysis by SEM. The data were analyzed statistically to determine the significance of differences. RESULTS. The adhesion strength of epithelial cells was higher on Ti surfaces with $5-{\mu}m$ laser dimples than on polished Ti surfaces, while the adhesion of fibroblasts was not significantly changed by laser treatment of implant surfaces. However, epithelial cells and fibroblasts around the laser dimples appeared larger and showed increased expression of adhesion proteins. CONCLUSION. These findings demonstrate that laser dimpling may contribute to improving the peri-implant soft tissue barrier. This study provided helpful information for developing the transmucosal surface of the abutment.

디지털 안궁이전과 가상교합기를 이용하여 하악의 운동을 고려한 구치부 수복 증례 (Posterior rehabilitation considering mandibular movement with digital facebow transfer and virtual articulator: A case report)

  • 김민범;권호범;임영준;김명주
    • 대한치과보철학회지
    • /
    • 제60권4호
    • /
    • pp.431-441
    • /
    • 2022
  • 디지털 안궁이전 장치로 하악의 운동로를 기록하고 캐드 소프트웨어(CAD software) 상에 반영할 수 있는데 이를 고려한 보철 수복은 치료 결과를 향상시킨다. 본 증례는 상하악 대구치가 소실된 환자에서 디지털 기술을 활용하여 임플란트를 식립 및 보철 수복한 증례이다. 구내 스캔 후 디지털 진단 왁스업을 토대로 임플란트 수술용 가이드를 제작한 뒤 임플란트 식립했다. 6개월의 충분한 골유착 후, 맞춤형 지대주와 첫번째 임시 보철물을 장착하였다. 2개월 후 지대주 수준에서 구강 스캔 및 디지털 안궁이전 장치로 가상 교합기 상마운팅하고 하악 운동을 기록했다. 하악의 움직임을 고려하여 두번째 임시 보철물을 제작, 장착 후 안정된 교합 상태에서 더블 스캔 과정으로 복제하여 지르코니아 최종 보철물을 디자인하고 장착했다.

구치부 상실로 인해 교합 평면이 기울어진 환자에서 임플란트를 이용한 구강 회복 증례 (Oral rehabilitation of a patient with collapsed occlusal plane resulting from loss of posterior teeth)

  • 한진우;장재승;표세욱;김선재
    • 대한치과보철학회지
    • /
    • 제62권2호
    • /
    • pp.165-173
    • /
    • 2024
  • 상실 부위를 수복하는 경우 정출된 치아에 대한 치료는 반드시 필요하다. 특히 치아 상실이 구치부에서 발생하여 구치부 지지의 상실이 지속되면 하악의 점진적인 위치를 이동시키면서 교합의 변화를 유발하기도 한다. 본 임상 증례는 상악 좌측 구치부 및 하악 우측 제1대구치 상실이 장기간 지속됨에 따라 대합치가 정출되고 교합평면이 무너진 환자에서 임플란트를 이용하는 고정성 보철물로 구치부 지지를 회복하고자 하였다. 정출된 부위의 교합평면을 수정하기 위해, 상실 부위의 진단 왁스업을 레진으로 복제하여 이를 상악에 장착한 후 교합면을 삭제하였다. 또한 임플란트 식립을 위해 디지털 기술을 활용한 임플란트 식립 가이드를 제작하였다. 임플란트의 식립으로 구치부의 지지가 회복된 이후에 진단 납형을 반영한 임시 수복물을 통해 충분한 시간동안 안정적인 교합 상태를 관찰하였고, 이후 임시 수복물의 형태를 복제한 단일 결정 지르코니아 보철물을 환자에게 장착함으로써 기능적, 심미적으로 만족스러운 결과를 얻었기에 이를 보고하는 바이다.

하악 무치악에서 즉시하중과 지연하중간 임플랜트의 안정성 변화 (STABILITY CHANGES OF IMMEDIATELY LOADED AND DELAYED LOADED IMPLANTS IN EDENTULOUS MANDIBLE)

  • 정혜은;김대곤;박찬진;조리라;이양진
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.250-262
    • /
    • 2007
  • Statement of problem: It was reported high success rate of implant-supported fixed prostheses using with $5{\sim}6$ implants on anterior mandible. Recently, immediate loading protocol was focused to overcome disadvantages of classic 2-stage delayed loading protocol. Purpose: This clinical study was to evaluate stability changes with time of immediately loaded and delayed loaded implants in edentulous mandible and to compare stability changes with time according to implantation sites. Materials and methods: Five or six implants were placed on anterior mandible depending on the arch shape. The immediately loading group was consisted of 8 patients received their prostheses within $24{\sim}48$ hours after implantation. The delayed loading group was consisted of 8 patients received their definitive prostheses following classical prosthetic procedures after a healing period of 3 months. All patients were recalled every 6 months for check-up. The evaluations of radiographic examination, ISQ value measurement and recording of complication were done. To evaluate marginal bone level, intraoral periapical radiographs were taken with long cone paralleling technique. At every evaluation recall, all prostheses were removed and ISQ values were measured with OsstellTM on individual implants. Results: 1. None of implants was failed. All implants showed stable marginal bone levels and ISQ values. 2. Marginal bone level changes with time showed statistically significant difference between immediately loading group and delayed loading group (P<0.001). 3. ISQ value changes with time did not show statistically significant difference between immediately loading group and delayed loading group (P=0.079). ISQ value decreased with time in both groups, however, all implants showed stable ISQ value at 30 months-recall evaluation. 4. Marginal bone level changes with time did not show statistically significant differences among implantation sites (P=0.604). 5. ISQ value changes with time showed statistically significant differences among implantation sites (P=0.047). ISQ values of most posterior implants decreased with time comparing to other implants. Conclusion: Although the marginal bone level of the terminal abutment didn't different with the other implants, ISQ value of the terminal abutment was lower than that of the other implants. Therefore, further clinical evaluation would be needed in this point of view.

두 종의 치과용 캐드 소프트웨어에 대한 반복학습의 효과 (Effect of repeated learning for two dental CAD software programs)

  • 손큰바다;이완선;이규복
    • 구강회복응용과학지
    • /
    • 제33권2호
    • /
    • pp.88-96
    • /
    • 2017
  • 목적: 치과 임플란트 캐드 소프트웨어를 이용하여 맞춤형 지대주 디자인 시에 소요되는 시간과 반복학습의 관계를 평가하는 것이다. 연구 재료 및 방법: 맞춤형 지대주 디자인은 3DS 캐드 소프트웨어와 EXO 캐드 소프트웨어를 사용하여 지정된 4개의 단계 순으로 시행되었고, 단계별로 3회 반복 측정하였다. 반복학습에 의한 학습효과는 학습곡선으로 나타냈고, 반복학습에 따른 디자인 시에 소요되는 총 시간과 단계별 소요되는 시간의 감소가 유의한지는 Friedman 검정과 사후검증(Wilcoxon signed rank test)으로 평가하였다. 디자인 시간과 군간의 차이는 반복 측정 이 요인 분석으로 평가하였다. 통계 분석은 SPSS 통계 소프트웨어를 사용하여 수행하였다(P < 0.05). 결과: 맞춤형 지대주 디자인의 반복학습은 횟수와 단계에 따라 유의한 차이를 나타냈다(P < 0.001). 디자인 시간에 따른 차이는 유의한 것으로 나타났으며(P < 0.001), 캐드 소프트웨어 간의 차이도 유의한 것으로 나타났다(P = 0.006). 결론: 캐드 소프트웨어의 반복학습은 디자인 시간을 단축하였고 디자인 평균시간은 3DS 캐드가 EXO 캐드에 비하여 더 적게 소요되었으나, 학습효과에 따른 학습률은 EXO 캐드가 3DS 캐드보다 좋은 결과를 보였다.

치과 임플란트에서 기성 지대주와 맞춤형 지대주의 응력분석 및 피로파절에 관한 연구 (Stress Analysis and Fatigue Failure of Prefabricated and Customized Abutments of Dental Implants)

  • 김희은;조인호
    • 구강회복응용과학지
    • /
    • 제29권3호
    • /
    • pp.209-223
    • /
    • 2013
  • 하악 제 1대구치에 티타늄과 지르코니아 소재의 기성 지대주와 맞춤형 지대주를 이용해 지르코니아 크라운으로 수복한 경우를 3차원 유한요소법을 통해 응력 분포를 분석해 보고, 피로 파절 강도 및 파절 형태를 고찰해 보았다. 정상교합자의 CT scan을 재구성한 하악골 모형상에 제 1대구치 임플란트 지지 지르코니아 크라운으로 수복한 6가지 유한요소 모형을 제작하고, 협측 교두 중앙에 수직과 30도 각도로 100 N의 하중을 가하는 조건으로 응력분포를 분석하였다. 현재 임상적으로 사용되고 있는 4가지 지대주를 이용하여, 군당 10개의 시편을 제작하고, ISO 14801에 따라 피로파절 실험을 실시하였다. 지대주나 고정체의 재질에 따른 응력분포의 차이는 없었고 형태에 따른 응력크기의 차이만 보였다. 맞춤형 지대주 군이 전반적으로 낮은 크라운 응력을 나타내었으며, 지대주 일체형 지르코니아 임플란트는 계면 골조직의 응력이 가장 낮게 나타났다. 피로수명의 평균값은 7군이 가장 높았고, 1군, 2군, 3군의 순서로 낮게 나타났으며(P<0.05), 기성 지대주 군은 피로수명의 편차가 적게 나타났다. 구치부의 임플란트 수복 시에는 맞춤형 지대주의 사용이 상부 보철물의 파절저항성 향상에 유리하며, 심미적 요구도가 높은 경우에는 고정체와의 접합부를 티타늄으로 제작한 지르코니아 맞춤형 지대주의 사용을 고려해 볼 만 하다.

Evaluation of effect of galvanic corrosion between nickel-chromium metal and titanium on ion release and cell toxicity

  • Lee, Jung-Jin;Song, Kwang-Yeob;Ahn, Seung-Geun;Choi, Jung-Yun;Seo, Jae-Min;Park, Ju-Mi
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권2호
    • /
    • pp.172-177
    • /
    • 2015
  • PURPOSE. The purpose of this study was to evaluate cell toxicity due to ion release caused by galvanic corrosion as a result of contact between base metal and titanium. MATERIALS AND METHODS. It was hypothesized that Nickel (Ni)-Chromium (Cr) alloys with different compositions possess different corrosion resistances when contacted with titanium abutment, and therefore in this study, specimens ($10{\times}10{\times}1.5mm$) were fabricated using commercial pure titanium and 3 different types of Ni-Cr alloys (T3, Tilite, Bella bond plus) commonly used for metal ceramic restorations. The specimens were divided into 6 groups according to the composition of Ni-Cr alloy and contact with titanium. The experimental groups were in direct contact with titanium and the control groups were not. After the samples were immersed in the culture medium - Dulbecco's modified Eagle's medium[DMEM] for 48 hours, the released metal ions were detected using inductively coupled plasma mass spectrometer (ICP-MS) and analyzed by the Kruskal-Wallis and Mann-Whitney test (P<.05). Mouse L-929 fibroblast cells were used for cell toxicity evaluation. The cell toxicity of specimens was measured by the 3-{4,5-dimethylthiazol-2yl}-2,5-diphenyltetrazolium bromide (MTT) test. Results of MTT assay were statistically analyzed by the two-way ANOVA test (P<.05). Post-hoc multiple comparisons were conducted using Tukey's tests. RESULTS. The amount of metal ions released by galvanic corrosion due to contact between the base metal alloy and titanium was increased in all of the specimens. In the cytotoxicity test, the two-way ANOVA showed a significant effect of the alloy type and galvanic corrosion for cytotoxicity (P<.001). The relative cell growth rate (RGR) was decreased further on the groups in contact with titanium (P<.05). CONCLUSION. The release of metal ions was increased by galvanic corrosion due to contact between base metal and titanium, and it can cause adverse effects on the tissue around the implant by inducing cytotoxicity.

임플란트의 collar design이 변연골과 연조직에 미치는 영향 (Effects of implant collar design on marginal bone and soft tissue)

  • 유현상;강선녀;정창모;윤미정;허중보;전영찬
    • 대한치과보철학회지
    • /
    • 제50권1호
    • /
    • pp.21-28
    • /
    • 2012
  • 연구 목적: 임플란트 경부가 잘 설계된 경우 양호한 연조직 반응을 통해 변연골을 보존하는데 도움이 된다. 본 실험에서는 연, 경조직 경계부에 가장 가까이 위치하는 임플란트의 collar design이 변연골 변화와 연조직 반응에 미치는 영향을 동물실험을 통해 알아보고자 하였다. 연구 재료 및 방법: 2마리의 건강한 Beagle dog에 임플란트 collar design만 다른 두 종류의 임플란트(Neobiotech Co. Seoul, Korea)를 식립하였다. Collar에 bevel 을 부여한 군(Bevel군)과 "S"자 형태를 부여한 군(Bioseal 군)으로 나누어 마리 당 7개, 군당 7개, 총 14개의 임플란트를 무작위로 식립한 후 Healing abutment를 즉시 체결하였다. 디지털 표준구내 방사선사진을 이용해 4주 간격으로 총 12주간 근원심 변연골 변화를 관찰하였고, 12주에 희생하여 조직학적 분석을 통해 협설 변연골 흡수 및 임플란트 주변 연조직 반응을 평가하였다. Mann-Whitney test를 통해 동일한 방사선 사진 촬영 시점에서 근원심 변연골 변화량 및 조직계측치를 군 간 비교하였고, Kruskal-Wallis test를 통해 방사선 사진상 근원심 변연골 변화량이 시간에 따른 차이가 있는지 군 내 분석 한 후 Duncan test를 통해 사후 검증하였다(${\alpha}=.05$). 결과: 방사선학적 분석 결과 각 촬영 시점에서 두 군간 근원심 변연골 변화량의 차이를 보이지 않았다(P>.05). 군내에서 시간에 따른 근원심 변연골의 흡수량을 분석한 결과 Bevel 군에서는 시간에 따른 차이를 보이지 않았으나 (P>.05), Bioseal 군에서는 시간에 따른 차이를 보였으며, 4주및 8주와 비교했을 때 12주에서 변연골의 증가를 보였다(P<.05). 조직학적 분석 결과 협설측 변연골 흡수량에서 두 군간 차이를 보이지 않았으나 (P>.05), Bevel 군에 비해 Bioseal 군에서 더 견고한 결합조직부착을 관찰할 수 있었으며, 생물학적 폭경의 값은 두 집단 간 차이를 보이지 않은 반면에 (P>.05), 접합상피부착은 Bevel 군에서 유의하게 길었고, 결합조직부착은 Bioseal 군에서 더 길게 나타났다(P<.05). 결론: Bevel 군에 비해 Bioseal 군에서 결합조직부착은 길게 형성된 반면에 접합상피부착은 더 짧게 나타났으며, 생물학적 폭경과 초기 변연골 흡수에는 차이가 없음을 알 수 있었다. 연조직 반응의 차이가 실제 기능하중 하에서 변연골 변화에 미치는 영향에 대해서 향후 연구가 필요할 것으로 생각된다.