• Title/Summary/Keyword: Implant type

Search Result 802, Processing Time 0.022 seconds

A method of contouring occlusal surface for reduction of implant overload (Implant overload 감소를 위한 교합면 형성 방법)

  • Lee, Byung-Woo;Park, Chan-Jin;Cho, Lee-Ra;Yi, Yang-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.2
    • /
    • pp.105-108
    • /
    • 2003
  • After stage-two surgery, the highest incidence of failure has been attributed to implant overload. However, the biomechanical factors cited inthe literature that contribute to implant overload, such as bone type, cuspal inclination, horizontal offset, maxillary compared to mandibular arch, the inclusion of natural teeth within the prosthesis, and occlusal harmony are superimposed on physiologic variations. Following two cases, including reduction of cuspal inclination and usage of modified incisal pin, showed a method of contouring occlusal surface for reduction of unpreditable implant overload.

A 15-year clinical retrospective study of Br${\aa}$nemark implants (Br${\aa}$nemark 임플란트의 15년 임상적 후향 연구)

  • Park, Hyo-Jin;Cho, Young-Ye;Kim, Jong-Eun;Choi, Yong-Geun;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.61-66
    • /
    • 2012
  • Purpose: This study was to compare the cumulative survival rate (CSR) of Br${\aa}$nemark machined surface implants and TiUnite$^{TM}$ imlants and to analyze association between risk factors and the CSR of the implants. Materials and methods: A retrospective study design was used to collect long-term follow-up clinical data from dental records of 156 patients treated with 541 Br${\aa}$nemark machined and TiUnite$^{TM}$ implants at Korea University Guro hospital in South Korea from 1993 through 2008. Machined implant and TiUnite$^{TM}$ implant were compared by CSR. Exposure variables such as gender, systemic disease, location, implant length, diameter, prosthesis type, opposing occlusion type, date of implant placement, type of edentulous space, abutment type, existence of splinting with natural teeth, and existence of cantilever were collected. Life table analysis was undertaken to examine the CSR. Cox regression method was conducted to assess the association between potential risk factors and overall CSR (${\alpha}$=.05). Results: Patient ages ranged from 16 to 75 years old (mean age, 51 years old). Implants were more frequently placed in men than women (94 men versus 63 women). Since 1993, 264 Br${\aa}$nemark machined implants were inserted in 79 patients and since 2001, 277 TiUnite$^{TM}$ implants were inserted in 77 patients. A total survival rate of 86.07% was observed in Br${\aa}$nemark and Nobel Biocare TiUnite$^{TM}$ during 15 years. A survival rate of machined implant during 15 years was 82.89% and that of TiUnite$^{TM}$ implant during 5 years was 98.74%. The implant CSR revealed lower rates association with several risk factors such as, systemic disease, other accompanied surgery, implant location, and Kennedy classification. Conclusion: Clinical performance of Br${\aa}$nemark machined and TiUnite$^{TM}$ implant demonstrated a high level of predictability. In this study, TiUnite$^{TM}$ implant was more successful than machined implant. The implant CSR was associated with several risk factors.

The effect of implant system with reverse beveled platform design on marginal bone stress distribution (임플란트 경부의 역사면 디자인이 변연골 응력분포에 미치는 영향)

  • Cha, Ji-Young;Cho, Jin-Hyun;Jo, Kwang-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.266-272
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the effects of the surface morphology of the implant neck on marginal bone stress measured by using finite element analysis in six implant models. Materials and methods: The submerged type rescue implant system (Dentis co., Daegu, Korea) was selected as an experimental model. The implants were divided into six groups whose implant necks were differently designed in terms of height (h, 0.4 and 1.0 mm) and width (platform width, w = 3.34 + 2b [b, 0.2, 0.3 and 0.4 mm]). Finite element models of implant/bone complex were created using an axisymmetric scheme. A load of 100 N was applied to the central node on the top of crown in parallel with the implant axis. The maximum compression stress was calculated and compared. Results: Stress concentration commonly observed around dental implants did not occur in the marginal bone around all six test implant models. Marginal bone stress varied according to the implant neck bevel which had different width and height. The stress was affected more markedly by the difference in height than in width. Conclusion: This result indicates that the implant neck bevel may play an important role in improving stress distribution in the marginal bone area.

Factors associated with the survival and marginal bone loss of dental implants: a 5-year retrospective study (임플란트의 생존과 변연골 소실에 영향을 미치는 인자들)

  • Song, Eul-Rak;Lee, Jae-Kwan;Um, Heung-Sik;Park, Se-Hwan;Chang, Beom-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.280-292
    • /
    • 2016
  • Purpose: The purpose of this study was to compare the long-term survival rate and peri-implant marginal bone loss related to multiple risk factors including the clinician's experience. Materials and Methods: Four hundred twenty implants in 146 patients, who had involved a supportive periodontal therapy program every 3 to 6 months and had follow up data for at least 5 years, were selected as the study group. Peri-implant marginal bone loss, data of demographic, implant and surgical characteristics were collected from peri-apical radiographs and chart review. Implant survival was regarded as the remaining with radiographic marginal bone level in excess of 50% of the fixture length for any reason. Results: The cumulative survival rate after 5 years of loading was 94.9%. In binary logistic regression analysis, smoking status (P = 0.033) and presence of spontaneous cover screw exposure (P < 0.001) were significantly related to 5-year survival of implants. In stepwise multiple regression analysis, smoking status (P < 0.001), type of abutment connection (P < 0.001) and implant surface (P = 0.033) were significantly related to peri-implant marginal bone level. And the year of resident was not statistically related to 5-year implant survival in simple logistic regression analysis (P = 0.171). Conclusion: Smoking status, spontaneous cover screw exposure, type of abutment connection and implant surface might influence the implant success. There was no significant correlation between the year of resident and implant failure.

Three Dimensional Comparative Study On The Accuracy Of Impression Technique Using New Impression Coping (새로운 인상용 코핑을 이용한 임플란트 인상법의 정확성에 대한 3차원적 비교 연구)

  • Kim, Se-Ra;Kim, In-Soo;Park, Sung-Jae;Lee, Byung-Ok;Ko, Sok-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.323-337
    • /
    • 2010
  • The objective of this study was to examine the availability of the new impression coping by comparing with conventional coping in implant pick-up impression technique. Five implant fixtures were installed on #14, 21, 23, 25, 27 in acrylic resin model. That model with 5 fixtures was standard model, which was divided 3 groups; using new flag type impression coping, conventional impression coping splinted with self-curing resin, conventional impression coping without splinting. We made metal circular cones for calculation 3-dimensional coordinates by attaching to implant fixtures or analogs. Three-dimensional relationships of each model were calculated. Data was analyzed by multiple ANOVA and Bonferroni. The accuracy of impression between using new flag type impression coping and conventional impression coping did not show differences in 3 - dimensional analysis.Within limitations of this study, the new flag type impression coping is available in implant pick-up impression technique.

THE EFFECT OF SUPPORTING BONE DESIGNED BY STRESS BREAKER TYPE IMPLANT DENTURE IN EXPERIMENTAL ANIMAL (Implant denture 에서 Stress breaker type가 주위골조직에 미치는 영향)

  • Suh, Chang-Hwan
    • The Journal of the Korean dental association
    • /
    • v.15 no.8
    • /
    • pp.623-626
    • /
    • 1977
  • The author made two implant blades of gold alloy metal, and applied CEKA attachment to one blade. These two blades were implanted at the sockets resulting from removal of both 3rd premolar of experimental dog. Simple crown and tooth supporting denture was constructed on the implanted blades the author observed above mentioned procedures for 8 weeks. The obtained results were as follows; 1) There is no remarkable necrosis of supporting alveolar bone on both sides So, metal reaction was favourable. 2) Masticatory force which is loaded on each tooth was not effective on the alveolar bone.

  • PDF

Treatment of flat foot with Kalix implant - case report - (Kalix implant를 이용한 편평족의 치료 - 증례보고 -)

  • Lee, Kyung-Tai;Young, Ki-Won;Bae, Sang-Won;Tak, Sang-Bo;Lee, Seung-Hwan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.6 no.2
    • /
    • pp.238-241
    • /
    • 2002
  • There are two types of flat foot, the one is congenital type and the other is acquired type. The treatments of flat foot are various and conservative treatment is general, except such as congenital talus. But, operative method is needed for treatment of failure of conservative method, severe deformity in X-ray, with tenderness in a juvenile period. We reported using Kalix implant for flat foot with pain and severe deformity.

  • PDF

A Digitally Designed All-on-4 Restoration with Screwmentable Concept

  • Park, Koungjin;Han, Jung-Suk;Lee, Jae-Hyun
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.84-91
    • /
    • 2022
  • An all-on-4 restoration allows edentulous patients to use a fixed prosthesis with a minimum number of implants. These implant-supported fixed complete dentures have traditionally been fabricated as screw-retained or cement-retained prostheses. However, it is difficult to passively fit the long-span full-arch prosthesis using the screw-retained type restoration, and predictable retrievability is not obtained with the cement-retained type. This case report describes a prosthesis fabricated using a combination of the two retention types. The screwmentable method allows the implant-supported fixed complete denture to achieve a passive fit at the connection with retrievability. In addition, a framework with an optimized size was designed by using digital dental technology.

AN ANALYSIS OF STRESS DISTRIBUTION AROUND THE IMPLANT ACCORDING TO THE BONE QUALITY AND BITE FORCE: FINITE ELEMENT METHOD (저작압이 임프란트 주위골 내 응력분포에 미치는 영향에 관한 연구)

  • Hyun Ki-Bong;Lee Sun-Hyung;Chang Ik-Tae;Yang Jae-Ho;Shin Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.4
    • /
    • pp.391-409
    • /
    • 2001
  • Since the early study about the osseointegration, lots of researches have been performed to increase the success rate and the stress around the implant in the jaw bone has been considered as one of the causes of failure. The purpose of this study was to examine the relationship between the implant failure and the stress by analysing the influence of different bone quality and bite force of some foods on the stress distribution around the implant, and to estimate the treatment result according to the bone quality and dietary pattern of patients. Bone quality was divided in 4 groups and models were drawn with the assumption that thread type implant(Nobel Biocare AB, Goteborg, Sweden) of 3.75mm diameter, 13mm length was installed to the bones. Various bite forces were applied to the occlusal surface of superstructure and the stress distributed around the implant were analysed with finite element analysis program. The results were as follows ; 1. The stress was changed proportionally to the bite forces of foods at all measuring points in all load cases. 2. The stress at the marginal bone was higher than that of the other measuring points in all load cases, and it was decreased at the first thread area. 3. The stress at the marginal bone was highest in type IV bone in all load cases. Especially it was twice those of other bone types at the bucco-lingual marginal bone and 50% higher at the mesio-distal marginal bone. 4. The stress at the bucco-lingual sides of the bone around the apical portions of implant showed little differences among the bone types, while type IV bone showed lower stress concentration than the other bone types in the mesio-distal sides. 5. Under the buccal oblique load ($15^{\circ}$ ), the stress at the lingual marginal bone was higher than that of buccal marginal bone, and the difference between the two points was almost same regardless of bone types.

  • PDF

A STUDY OF THE ANTI-ROTATING INNER POST SCREW SYSTEM AS A MEANS OF PREVENTING ABUTMENT SCREW LOOSENING (회전 방지용 Post Screw 시스템의 임플랜트 지대나사풀림 방지효과에 관한 연구)

  • Kim Jong-Hui;Lim Ju-Hwan;Cho In-Ho;Lee Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.5
    • /
    • pp.671-683
    • /
    • 2005
  • Statement of problem: The most commonly reported problem associated with dental implant restoration is the loosening of the screws. Purpose: This study compared the efficacy of an implant system incorporating an anti-rotational locking sleeve(Anti-Rotating Inner Post Screw System(ARIPS-system)) with other, traditional implant systems as a means of minimizing vibration loosening. Materials and methods: Three implant systems were examined; the conventional external hex type, the ARIPS-system, and the internal taper type implant system 30 specimens(10 samples per group)were fabricated and each abutment screw was secured to the implant future with 32Ncm of torque force and loosening torque was measured using a Torque Gauge. The procedure was repeated 3 times, recording initial loosening torque each time. The re-tightened abutment screw was subjected to a cyclic load having a maximum forte of 200N and minimum of 20N at 2Hz over a period of 12,600 cycles. after which the loosening torque was measured. Measured values were calaulated for statistical analysis. Analysis of measured value was performed by 3 methods: (i) as a percentage average of the initial 3 loosening-torque values(initial loosening value) to the tightening torque of 32Ncm, (ii) as a percentage of the loosening torque value after a load of 200N(experimental value) to the initial loosening value, and (iii) as a percentage of the experimental value to the 32Ncm of tightening torque. The analyses shows the amount of initial loosening at the screw, loosening by repetitive load and the the final loosening value. Results: The results of this study were as follows (1) Percentage of initial loosening value to tightening-torque was increased in order of external hex, ARIPS-system and internal taper and all values between each groups showed statistical significance (p<0.05). (2) Percentage of experimental value to initial loosening value was increased in order of external hex, ARIPS-system and internal taper. Value of internal taper showed significant difference with those of external hex and ARIPS-system (p<0.05). (3) Percentage of experimental value to tightening torque was increased in order of external hex, ARIPS-system and internal taper and all values between each groups showed statistical significance (p<0.05). Conclusion: The results of the analysis of the final loosening level value, which are closely correlated to clinical use, show that the ARIPS-system can be a useful means of minimizing abutment screw loosening when compared to the external hex type system. Although further clinical studies need to be made, the ARIPS-system should be considered to maximize the long-term success of the implant prosthesis.