• Title/Summary/Keyword: Implant surgical guide

Search Result 71, Processing Time 0.025 seconds

Satisfaction of patients with implants placed using the implant surgical guide (임플란트 수술용 가이드를 이용하여 임플란트를 식립한 환자의 만족도)

  • Jae-Ra, Lee
    • Journal of Korean Dental Hygiene Science
    • /
    • v.5 no.2
    • /
    • pp.53-60
    • /
    • 2022
  • Background: This study was aimed at improving the satisfaction of patients with implants placed using an implant surgical guide by analyzing patient satisfaction with the implant procedure carried out using the guide . Methods: We extracted convenient samples from patients with implants who had visited dental hospitals and clinics in Mokpo from March 2 to June 30, 2022. We used 228 copies of the self-report survey for analyses. Results: All items of implant satisfaction were positively correlated with the use of an implant surgical guide. Conclusions:The results of this study showed that implant satisfaction can be increased with the use of implant surgical guides.

Patient satisfaction survey for implant surgical guides in some areas of Jeollanam-do (전남 일부 지역 임플란트 수술용 가이드 이용 환자 만족도 조사)

  • Yoon, So-Ra;Choi, Choong-Ho
    • Journal of Korean society of Dental Hygiene
    • /
    • v.22 no.4
    • /
    • pp.281-287
    • /
    • 2022
  • Objectives: This study, investigated the satisfaction of patients who received the procedure using an implant guide to identify factors affecting satisfaction in dental hospitals and clinics in Jeollanam-do. Methods: From December 2021 to February 2022, questionnaires randomly were collected from 128 patients aged 20 to 90 years visiting dental hospitals and clinics using surgical guides in some areas of Jeollanam-do. Results: There was a negative correlation between the overall satisfaction average and Visual Analog Scale (VAS) pain level (r=-0.414, p<0.001), and a negative correlation between VAS pain level and VAS satisfaction (r=-0.273, p<0.05), As subjective pain decreased, subjective satisfaction increased, and as subjective pain increased, the overall satisfaction average also decreased, showing an inverse correlation. Factors affecting satisfaction with the guide for implant surgery were whether you would like to recommend it to people around you (β=0.556), whether you would like to explain the guide (β=0.194), and whether you thought it was good to receive the guide (β=0.199). Conclusions: Therefore, in order to increase the satisfaction of the implant surgical guide procedure, it is considered important to perform a sufficient explanation of the implant surgical guide before the procedure.

Comparison of accuracy between free-hand and surgical guide implant placement among experienced and non-experienced dental implant practitioners: an in vitro study

  • Dler Raouf Hama;Bayad Jaza Mahmood
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.5
    • /
    • pp.388-401
    • /
    • 2023
  • Purpose: This study investigated the accuracy of free-hand implant surgery performed by an experienced operator compared to static guided implant surgery performed by an inexperienced operator on an anterior maxillary dental model arch. Methods: A maxillary dental model with missing teeth (No. 11, 22, and 23) was used for this in vitro study. An intraoral scan was performed on the model, with the resulting digital impression exported as a stereolithography file. Next, a cone-beam computed tomography (CBCT) scan was performed, with the resulting image exported as a Digital Imaging and Communications in Medicine file. Both files were imported into the RealGUIDE 5.0 dental implant planning software. Active Bio implants were selected to place into the model. A single stereolithographic 3-dimensional surgical guide was printed for all cases. Ten clinicians, divided into 2 groups, placed a total of 60 implants in 20 acrylic resin maxillary models. Due to the small sample size, the Mann-Whitney test was used to analyze mean values in the 2 groups. Statistical analyses were performed using SAS version 9.4. Results: The accuracy of implant placement using a surgical guide was significantly higher than that of free-hand implantation. The mean difference between the planned and actual implant positions at the apex was 0.68 mm for the experienced group using the free-hand technique and 0.14 mm for the non-experienced group using the surgical guide technique (P=0.019). At the top of the implant, the mean difference was 1.04 mm for the experienced group using the free-hand technique and 0.52 mm for the non-experienced group using the surgical guide technique (P=0.044). Conclusions: The data from this study will provide valuable insights for future studies, since in vitro studies should be conducted extensively in advance of retrospective or prospective studies to avoid burdening patients unnecessarily.

Reliability of a chairside CAD-CAM surgical guide for dental implant surgery on the anterior maxilla: An in vitro study

  • Phyo Ei Ei Htay;Richard Leesungbok;Suk Won Lee;Yu-Jin Jee;Kyung Lhi Kang;Sung Ok Hong
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.5
    • /
    • pp.259-270
    • /
    • 2023
  • PURPOSE. This study evaluated the reliability of the chair-side CAD-CAM surgical guide (CSG) in the anterior maxilla by comparing its accuracy with the laboratory 3D-printed surgical guide (3DSG) and manual surgical guide (MSG) concerning different levels of dentists' surgical experience. MATERIALS AND METHODS. Ten surgical guides of each type (MSG, 3DSG, and CSG) were fabricated on a control study model with missing right and left central incisors. Sixty implants were placed in 30 study models by two dentists (one inexperienced and one experienced) using three different types of surgical guides. Horizontal deviations at shoulder and at apex, vertical, and angular deviations were measured after superimposing the planned and placed implant positions in the software. Kruskal-Wallis and Mann-Whitney U tests were used to compare the accuracy of three types of surgical guides in each dentist group and the accuracy of each surgical guide between two dentists (α = .05). RESULTS. There were no significant differences in any deviations between CSG and 3DSG, apart from angular deviation, for both dentists' groups. Moreover, both CSG and 3DSG showed no significant differences in accuracy between the two dentists (P > .05). In contrast, MSG demonstrated significant differences from CSG and 3DSG and a significant difference in accuracy between the two dentists (P < .05). CONCLUSION. CSG provides superior accuracy to MSG in implant placement in the maxillary anterior region and is comparable to 3DSG at different levels of surgical experience, while offering the benefits of shorter manufacturing time and reduced patient visits.

Rational treatment planning for implant treatment of the edentulous patients (완전무치악환자의 전악 임플란트 치료 계획 수립을 위한 체계적인 접근법)

  • Jeong-In Bae
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.32 no.2
    • /
    • pp.54-68
    • /
    • 2023
  • Treatment planning of edentulous patient with digital method is materialized by designing the surgical guide. When designing the surgical guide, we first implement the shape of the final prosthesis in the virtual space and then materialize the implantation plan based on this. However, it is challenging to make surgical guides for edentulous patients as their lack of both the reference for the arrangement of teeth and interocclusal relationship makes it hard to envision the shape of the final prosthesis. If there exists good partial or complete dentures or residual teeth, its teeth arrangement can be used as a reference for the virtual final prosthesis and the subsequent surgical guide. If such a reference is absent or unsatisfactory, a process of manufacturing a complete denture for diagnostic purposes and verifying it on patient's mouth is necessary and use it as a new reference for the virtual final prosthesis. But even if a surgical guide is produced through the reference from the thorough reflection of the virtual final prosthesis, when we use it in the surgical field, the intraoral condition of the patient may make the implants deviated from planned in the surgical guide. In the worst case, if the positioning of the surgical guide on the mouth is incorrect, it can lead to a catastrophic error that displaces all the implant, in which case the guided surgery would be much worse than the non-guided one. In this article, we will discuss how to obtain references of tooth arrangements in a timely manner and align or register them into a unified coordinate system in digital space, and also introduce how to transfer such an implantation plan from the virtual world into the patient's mouth of real world with minimum error. And lastly, I would like to express my opinion on the establishment of a rational and systematic protocol of guided surgery of the edentulous patients.

A 10-year follow-up study on clinical outcomes of dental implant rehabilitation using surgical guide

  • Haoyun Li;Mi Young Eo;Kezia Rachellea Mustakim;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.50 no.2
    • /
    • pp.70-79
    • /
    • 2024
  • Objectives: The surgical guide is a static computer-assisted device used for implant surgery planning and guidance. By taking an impression and referring to the patients' three-dimensional computed tomography scan of the desired implant site, a surgical guide can be created. During surgery, the surgical guide aids in achieving the designed implant placement position and direction. We examined and evaluated the long-term clinical outcomes of implant surgery using surgical guides. Materials and Methods: This study investigated a total of 15 patients with 32 implants that were placed using surgical guides from 2009 to 2011 with a mean follow-up period extended beyond 10 years. Patient demographics and implant survival rates were recorded. We analyzed marginal bone loss (MBL) by assessing the radiographs acquired at installation, three months after installation, and one month, one, two, and five years after prosthesis delivery. Results: The mean patient age was 57.33 years at implant placement. Of the 32 implants, five implants were placed in the anterior region and 27 implants were in the posterior region. Six implants failed and three of them were replaced, resulting in an 81.25% survival rate. The mean follow-up period was 10 years and nine months. Mean MBL compared to post-installation was significantly higher than at three months after installation, and one month, one, two, and five years after prosthesis delivery. Mean MBL at three months after installation, and one month, one year, and two years were significantly higher compared to the previous visit (P<0.05). However, MBL at five years after prosthesis delivery did not differ significantly compared to at two years. Conclusion: In this study, implant rehabilitation assisted by surgical guides exhibited favorable survival rates. With the limitation of the sample amount in this study, further research and more samples are required to evaluate the long-term clinical effectiveness of surgical guides.

Thermal changes during implant site preparation with a digital surgical guide and slot design drill: an ex vivo study using a bovine rib model

  • Choi, Yoon-Sil;Oh, Jae-Woon;Lee, Young;Lee, Dong-Woon
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.5
    • /
    • pp.411-421
    • /
    • 2022
  • Purpose: In this study, we aimed to evaluate the degree of heat generation when a novel drill design with an irrigation slot was used with metal sleeve-free (MF) and metal sleeve-incorporated (MI) surgical guides in an environment similar to that of the actual oral cavity. Methods: A typodont with a missing mandibular right first molar and 21 bovine rib blocks were used. Three-dimensional-printed MF and MI surgical guides, designed for the placement of internal tapered implant fixtures, were used with slot and non-slot drills. The following groups were compared: group 1, MI surgical guide with slot drill; group 2, MI surgical guide with a non-slot drill; and group 3, MF surgical guide with a slot drill. A constant-temperature water bath at 36℃ was used. The drilling was performed in 6 stages, and the initial, highest, and lowest temperatures of the cortical bone were measured at each stage using a non-contact infrared thermometer. Results: There were no temperature increases above the initial temperature in any drilling procedure. The only significant difference between the non-slot and slot groups was observed with the use of the first drill in the MI group, with a higher temperature in the non-slot group (P=0.012). When the heat generation during the first and the second drilling was compared in the non-slot group, the heat generation during the first drilling was significantly higher (P<0.001), and there was no significant difference in heat generation between the drills in the slot group. Conclusions: Within the limitations of this study, implant-site preparation with the surgical guide showed no critical increase in the temperature of the cortical bone, regardless of whether there was a slot in the drill. In particular, the slotted drill had a cooling effect during the initial drilling.

An analysis on satisfaction level of clinicians on implant surgical guidance system based on computed tomography (컴퓨터 단층 촬영을 기반으로 한 임플란트 가이드 시스템에 대한 임상가의 만족도 분석)

  • Hong, Min-ho;Jin, Ming-Xu;Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.3
    • /
    • pp.178-185
    • /
    • 2015
  • Purpose: The purpose of this study was to conduct a comparative assessment on the satisfaction level for the two interfaces of surgical guide system (SimPlant and R2GATE), the design and convenience of manufactured surgical guides and the importance of using the surgical guides thereof by means of survey. Materials and Methods: Hereupon, they simulated the implant surgical process by mounting the two manufactured systems of surgical guide on a dental mold, respectively. The study subjects were instructed to complete the questionnaire as to the satisfaction level upon completion of the simulated surgery. This study summarized the data of each question after collecting the completed questionnaires. Then, this study analyzed the summarized data by utilizing statistical program SPSS 20.0 (IBM). Results: R2GATE had a higher value of the satisfaction level on the design and convenience of manufactures surgical guides. R2GATE group ($7.33{\pm}1.26$) was found to have a higher value in terms of the overall satisfaction level compared to SimPlant group ($6.67{\pm}1.26$) (${\alpha}$ = 0.05). Conclusion: The user satisfaction level on the surgical guide manufactured for R2GATE system was to such an extent as it can be widely used in clinical environment. Moreover, the surgical guide manufactured as R2GATE system can guide both the length and direction of a drill simultaneously. As a result, it is highly recommended for those beginners who do not have a lot of experience in implant placement.

3D Simulation of Dental Implant Surgery Using Surgical Guide Stents (식립 보조도구를 이용한 3D 치아 임플란트 시술 시뮬레이션)

  • Park, Hyung-Wook;Kim, Myong-Soo;Park, Hyung-Jun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.3
    • /
    • pp.216-226
    • /
    • 2011
  • Surgeon dentists usually rely on their experiential judgments from patients' oral plaster casts and medical images to determine the positional and directional information of implant fixtures and to perform drilling tasks during dental implant surgical operations. This approach, however, may cause some errors and deteriorate the quality of dental implants. Computer-aided methods have been introduced as supportive tools to alleviate the shortcomings of the conventional approach. In this paper, we present an approach of 3D dental implant simulation which can provide the realistic and immersive experience of dental implant information. The dental implant information is primarily composed of several kinds of 3D mesh models obtained as follows. Firstly, we construct 3D mesh models of jawbones, teeth and nerve curves from the patient's dental images using software $Mimics^{TM}$. Secondly, we construct 3D mesh models of gingival regions from the patient's oral impression using a reverse engineering technique. Thirdly, we select suitable types of implant fixtures from fixture database and determine the positions and directions of the fixtures by using the 3D mesh models and the dental images with software $Simplant^{TM}$. Fourthly, from the geometric and/or directional information of the jawbones, the gingival regions, the teeth and the fixtures, we construct the 3D models of surgical guide stents which are crucial to perform the drilling operations with ease and accuracy. In the application phase, the dental implant information is combined with the tangible interface device to accomplish 3D dental implant simulation. The user can see and touch the 3D models related with dental implant surgery. Furthermore, the user can experience drilling paths to make holes where fixtures are implanted. A preliminary user study shows that the presented approach can be used to provide dental students with good educational contents. With future work, we expect that it can be utilized for clinical studies of dental implant surgery.

The use of surgical guide stent for implant placement (임플란트 식립을 위한 수술 가이드의 사용)

  • Lee, Ji-Yeon;Yoon, Ji-Young;Oh, Namsik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.366-375
    • /
    • 2014
  • Surgical guide not only provide diagnosis and treatment plan, but even location and direction of implantation. Surgical guide could be divided into non-limited design, partially limited design, and completely limited design. Partially limited design is easily manufactured and inexpensive but less accuracy, compared to completely limited design. From this approach, partially limited design may be particularly effective in patients who present with a single missing tooth or partially edentulous teeth. Completely limited design is anatomically accuracy, esthetical and functional, optimized treatment for prosthetic and biomechanical perspective, and also minimizes discomfort for post-treatment. The purpose of this study is to review previous studies of various surgical guides and applying in clinic.