• Title/Summary/Keyword: Implant placement

Search Result 644, Processing Time 0.024 seconds

Non-submerged type implant stability analysis during initial healing period by resonance frequency analysis (Resonance frequency analysis를 이용한 non-submerged type 임플란트의 초기 안정성 분석)

  • Kim, Deug-Han;Pang, Eun-Kyoung;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.3
    • /
    • pp.339-348
    • /
    • 2009
  • Purpose: The purpose of the present study was to analyze the implant stability quotient(ISQ) values for Korean non-submerged type implant and determine the factors that affect implant stability. Methods: A total of 49 Korean non-submerged type implants were installed in 24 patients, and their stability was measured by resonance frequency analysis(RFA) at the time of surgery, and 1, 2, 3, 4, 8, 12 weeks postoperatively. The data for implant site, age, sex, implant length and diameter, graft performing, bone type, and insertion torque were analyzed. Results: The lowest mean stability measurement was at 3 weeks. There was significant difference between implant placement and 12 weeks. There was significant difference between implant placement and 12 weeks in diameters of 4.1 mm and 4.8 mm. Also, there were significant differences between diameters of 4.1 mm and 4.8 mm at implant placement and 12 weeks after surgery. This result suggests that the factor related to implant diameter may affect the level of implant stability. No statistically significant relationship was found between the resonance frequency analysis and the variables of maxilla/mandible, sex, anterior/posterior, implant length, age of patient, graft performing, bone type, insertion torque during initial healing period. Conclusions: These findings suggest that the factor related to implant diameter may affect the variance of implant stability, and ISQ value of implant was stable enough for proved stability level during initial healing period.

Simultaneous implant placement with sinus augmentation using a modified lateral approach in the pneumatized posterior maxilla: A Case Report (함기화된 상악 구치부에서 변형 측방 접근법을 이용한 상악동 거상술과 임플란트 동시식립에 대한 증례보고)

  • Sun, Yoo-Kyung;Cha, Jae-Kook;Lee, Jung-Seok;Jung, Ui-Won
    • The Journal of the Korean dental association
    • /
    • v.56 no.3
    • /
    • pp.142-150
    • /
    • 2018
  • In the posterior maxillary area, due to resorption of the ridge after extraction and pneumatization of the maxillary sinus, the height of the alveolar ridge may not be sufficient for placement of implants. To solve this problem, sinus augmentation using both crestal and lateral approaches have been widely used. Jung et al. (2010) introduced the modified lateral approach technique, which is a simplified technique that combines the advantages of crestal and lateral approaches. The purpose of this case report is to report two cases in the posterior maxilla in which simultaneous implant placement with maxillary sinus augmentation has been performed using the modified lateral approach technique. In two female patients, 67 and 74 years old, respectively, simultaneous implant placement was performed using the modified lateral approach technique on the left maxillary second premolar and the first molar. In both patients, the residual bone height on the distal side of the maxillary second premolar was measured to be approximately 5 mm, and the residual bone height of the first molar was measured to be 2-3 mm. After flap elevation, osteotomy of the lateral window was performed in the form of a mesiodistally extended slot above the sinus floor and the Schneiderian membrane was elevated. Sequenced drilling was performed while protecting the membrane with a periosteal elevator. Bone graft and implant placement was performed after preparation of the implant site. Sufficient primary stability was achieved for each implant and sinus membrane was not perforated. After four and five months respectively, implant second surgery was performed. Clinically, the implants were observed to be stable. Implants and surrounding peri-implant mucosa were well maintained after prosthodontic treatment. In conclusion, the modified lateral approach could be a predictable and efficient technique for implant placement in the atrophied posterior maxilla.

  • PDF

Functional Endoscopic Sinus Surgery for a Patient with Maxillary Sinusitis Occurring after Implant Placement

  • You, Jae-Seek;Kim, Su-Gwan;Oh, Ji-Su;Jeong, Gyeong-Dal;Mah, Deuk-Hyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.5
    • /
    • pp.331-336
    • /
    • 2013
  • Maxillary sinus membrane elevation and bone graft have been performed routinely in alveolar bone with insufficient residual bone height. There are a number of causes for development of maxillary sinusitis after these procedures. When maxillary sinusitis is caused by sinus membrane elevation, bone graft, and implant placement, various treatment such as medication, incision and drainage (I&D), implant removal, and the Caldwell-Luc procedure can be considered. Removal of an implant or the Caldwell-Luc procedure can be harmful if inflammation is not present in the oral cavity and survival of grafted bone and implant osseointegration can be expected despite the presence of maxillary sinusitis. In this case, functional endoscopic sinus surgery, which was often used in the otorhinolaryngology department, was performed without removal of the implant for a patient with maxillary sinusitis after one month following implant placement. Thus, we report on this case with a review of the literature.

Alterations of the soft tissue dimensions around implant-supported singletooth replacements in the maxillary anterior region - A retrospective longitudinal study - (상악 전치부 임플란트지지 수복금관의 주변 연조직 제원 변화에 관한 누년적 연구)

  • Chang, Moon-taek
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.3
    • /
    • pp.507-517
    • /
    • 1998
  • This study was performed to investigate the soft tissue changes around single implant-supported crowns during followup periods. Twenty patients(31 implants) whose single missing tooth in the maxillary anterior region had been replaced with an single implant-supported crown were recruited for the study. Crown length, soft tissue level and papilla height at the single implant-supported crowns were measured at follow-up examination and calculated from the slides taken at time of crown placement. as well Papilla index was scored from the slides taken at the time of crown placement and follow-up examination. A very little amount of recession occurred and the soft tissue level moved more apically and the papilla height increased significantly (p<0.01). Especially, both mesial and distal papilla index at single implant-supported crowns increased significantly during follow-up periods (p<0.001). When the two slides taken at the time of crown placement and follow-up were compared simultaneously, except one site, papillae size increased at all sites. From the results of the study, the interdental papillae at the single implant-supported crowns seemed to regenerate significantly and their crown margins were stable during follow-up periods. Hence it is indicated that various surgical interventions at on early stage to enhance soft tissue esthetics arourd single implants may be unnecessary.

  • PDF

A HISTOMORPHOMETRIC STUDY OF BONE FORMATION AROUND IMPLANTS PLACED AFTER VERTICAL ALVEOLAR DISTRACTION IN THE DOG MEDEL (치조골신장 부위에 식립된 임프란트 주위의 골형성에 관한 연구)

  • Park, Jong-Oh;Rhu, Dong-Mok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.4
    • /
    • pp.312-321
    • /
    • 2007
  • Purpose: Distraction osteogenesis has been applied to the maxillofacial implantology and good experimental and clinical results have been reported. However, histologic studies of implants placement on distraction osteogenesis of atrophic alveolar ridges are scarce. In this study, we compare the bone formation between in the transport part and in the distraction part by histomorphometric analysis. Materials & methods: Three adult beagle dogs were served as experimental subjects. The 2 premolars and 1st molar were extracted on the Lt. side of mandible in each beagle dog. After one month later, osteotomy was performed and distraction device was adapted. Distraction was performed with gradual incremental separation of two bone pieces at a rate of 1.0mm per day for 5 days. During consolidation phase, new bone was formed in the distraction zone between the separated bone pieces. 5 weeks after distraction phase, 3 implants were placed in each beagle dog. The implants were inserted through transport part and distraction part and inferior basal bone. The animals were sacrificed at 2 weeks, 4 weeks, and 12 weeks after implant placement. BIC and BA of implants on distraction part and transport part were measured histomorphometrically. Results: BIC, BA increased after implant placement as time goes by passes and new bone formation was slightly higher in transport part than in distraction part at 2 weeks, 4 weeks after implant placement. At 12 weeks after implant placement, BIC, BA of were 74%, 61% in transport part and 77%, 59% in distraction part, therefore there were no difference in BIC and BA between transport part and distraction part at 12 weeks after implant placement.

Stress analysis according to the different angulation of the implant fixture (임플란트 고정체의 매식 경사에 따른 응력분석)

  • Lee, Tae-Yup;Kang, Dong-Wan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.4
    • /
    • pp.321-329
    • /
    • 2002
  • Bending moments results from offset overloading of dental implant, which may cause stress concentrations to exceed the physiological capacity of cortical bone and lead to various kinds of mechanical failures. The purpose of this study was to compare the distributing pattern of stress on the finite element models with the different angulated placement of dental implant in mandibular posterior missing areas. The three kinds of finite element model, were designed according to 3 main configurations: Model 1(parallel typed placement of 2 fixtures), Model 2(15. distal angulated placement of one fixture on second molar area), Model 3(15. mesial angulated placement of one fixture on second molar area). The cemented crowns for mandibular first and second molars were made on the two fixtures (4mm 11.5). Three-dimensional finite element models by two fixtures were constructed with the components of the implant and surrounding bone. A 200N vertical static load were applied to the center of central fossa and the point 2mm apart from the center of central fossa on each model. The preprocessing, solving and postprocessing procedures were done by using FEM analysis software NISA/DISPLAY IV Version 10.0((Engineering Mechanics Research Corporation, USA). Von Mises stresses were evaluated and compared in the supporting bone, fixtures, and abutment. The results were as following : (1) Under the point loading at the central fossa, the direction of angulated fixture affected the stress pattern of implants. (2) Under the offset loading, the position of loading affected more on the stress concentration of implants compare to the angulated direction of implants. The results had a tendency to increase the stress on the supporting bone, fixture and screw under the offset loads when the placement angulation of implant fixture is placed toward mesial or distal direction. In designing of the occlusal scheme for angulated placement, placing the occlusal contacts axially during chewing appears to have advantages in a biomechanical viewpoint.

Bone-added osteotome sinus floor elevation with simultaneous placement of non-submerged sand blasted with large grit and acid etched implants: a 5-year radiographic evaluation

  • Jung, Jee-Hee;Choi, Seong-Ho;Cho, Kyoo-Sung;Kim, Chang-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.2
    • /
    • pp.69-75
    • /
    • 2010
  • Purpose: Implant survival rates using a bone-added osteotome sinus floor elevation (BAOSFE) procedure with simultaneous placement of a non-submerged sand blasted with large grit and acid etched (SLA) implant are well documented at sites where native bone height is less than 5 mm. This study evaluated the clinical results of non-submerged SLA Straumann implants placed at the time of the BAOSFE procedure at sites where native bone height was less than 4 mm. Changes in graft height after the BAOSFE procedure were also assessed using radiographs for 5 years after the implant procedure. Methods: The BAOSFE procedure was performed on 4 patients with atrophic posterior maxillas with simultaneous placement of 7 non-submerged SLA implants. At least 7 standardized radiographs were obtained from each patient as follows: before surgery, immediately after implant placement, 6 months after surgery, every year for the next 3 years, and after more than 5 years had passed. Clinical and radiographic examinations were performed at every visit. Radiographic changes in graft height were calculated with respect to the implant's known length and the original sinus height. Results : All implants were stable functionally, as well as clinically and radiographically, during the follow-up. Most of the radiographic reduction in the grafted bone height occurred in the first 2 years; reduction after 2 years was slight. Conclusions: The simultaneous placement of non-submerged SLA implants using the BAOSFE procedure is a feasible treatment option for patients with severe atrophic posterior maxillas. However, the grafted bone height is reduced during the healing period, and patients must be selected with care.

Use of Acellular Biologic Matrix Envelope for Cardiac Implantable Electronic Device Placement to Correct Migration into Submuscular Breast Implant Pocket

  • Peyton Terry;Kenneth Bilchick;Chris A. Campbell
    • Archives of Plastic Surgery
    • /
    • v.50 no.2
    • /
    • pp.156-159
    • /
    • 2023
  • Breast implants whether used for cosmetic or reconstructive purposes can be placed in pockets either above or below the pectoralis major muscle, depending on clinical circumstances such as subcutaneous tissue volume, history of radiation, and patient preference. Likewise, cardiac implantable electronic devices (CIEDs) can be placed above or below the pectoralis major muscle. When a patient has both devices, knowledge of the pocket location is important for procedural planning and for durability of device placement and performance. Here, we report a patient who previously failed subcutaneous CIED placement due to incision manipulation with prior threatened device exposure requiring plane change to subpectoral pocket. Her course was complicated by submuscular migration of the CIED into her breast implant periprosthetic pocket. With subcutaneous plane change being inadvisable due to patient noncompliance, soft tissue support of subpectoral CIED placement with an acellular biologic matrix (ABM) was performed. Similar to soft tissue support used for breast implants, submuscular CIED neo-pocket creation with ABM was performed with durable CIED device positioning confirmed at 9 months postprocedure.

Factors Affecting Survival of Maxillary Sinus Augmented Implants (상악동 거상술을 동반한 임플란트의 생존율에 관한 기여인자)

  • In, Yeon-Soo;Park, Young-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.3
    • /
    • pp.241-248
    • /
    • 2011
  • Purpose: The aim of this study was to present the clinical results of maxillary sinus augmentation implants and to evaluate the effects of various factors on the implant survival rate. Methods: In a total of 112 patients, 293 implants after sinus augmentation were performed. The total survival rate and the influence of the following factors on implant survival were evaluated; patient characteristics (sex, age, smoking, general disease), graft material, implant surface, implant installation stage, site of implant placement, length and width of implant, closure method for osseous window, residual alveolar bone height. Results: 1. Age ranged from 16 to 70 yr, with a mean of 45.7 yr. 2. Cumulative survival rate for the 293 implants with the maxillary sinus augmentation procedure was 94.9%. 3. Simultaneous implant installation was performed in 122 patients and delayed implant installation was performed in 117 implants. The average healing period after sinus elevation was 7.3 months for delayed implant installation and this procedure had a significantly higher survival rate. 4. There were no significant differences in sex, age, smoking, general disease, site of implant placement, length and width of implant, residual alveolar bone height and the survival rate. 5. RBM (Resorbable Blasting Media) implant surface and allograft groups had significantly lower survival rates. Conclusion: These data suggest that maxillary sinus augmentation may give more predictable results for autogenous bone grafts and delayed implant placement.

Ridge Augmentation Using Vascularized Interpositional Periosteal- Connective Tissue (VIP-CT) in Conjunction with Anterior Implant Placement in Maxilla : Report of Three Cases (상악 전치부의 임플란트 식립과 관련하여 혈관개재골막결합조직판막술을 이용한 치조제증대술: 3가지 증례보고)

  • Kim, Yun-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.2
    • /
    • pp.207-214
    • /
    • 2008
  • Purpose: The aim of augmentation of the alveolar ridge is to restore absorbed alveolar ridges for future implant site or esthetic prosthodontic restoration. The present clinical report describes the anterior maxillary augmentation cases using a soft tissue rotated palatal flap, and considers various problems of before and after surgery. Method: First & second patients were treated by vascularized interpositional periosteal-connective tissue(VIP-CT) flap for horizontal soft tissue augmentation. Especially second patient was progressed with bone grafting at the same time. Third patient was treated by the same flap with bone graft and implant placement in single tooth missing premaxillary area. Result: The obtained horizontal augmentation width measured $0.5{\sim}2.7\;mm$. Conclusion: This technique constitutes a viable approach for augmentation the anterior sector of alveolar ridge with the placement of dental implants. But it needs correct diagnosis preparation and careful surgery skill.