• Title/Summary/Keyword: Implant fracture

Search Result 307, Processing Time 0.023 seconds

Fracture resistance of implant- supported monolithic crowns cemented to zirconia hybrid-abutments: zirconia-based crowns vs. lithium disilicate crowns

  • Elshiyab, Shareen H;Nawafleh, Noor;Ochsner, Andreas;George, Roy
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2018
  • PURPOSE. The aim of this in vitro study was to investigate the fracture resistance under chewing simulation of implant-supported posterior restorations (crowns cemented to hybrid-abutments) made of different all-ceramic materials. MATERIALS AND METHODS. Monolithic zirconia (MZr) and monolithic lithium disilicate (MLD) crowns for mandibular first molar were fabricated using computer-aided design/computer-aided manufacturing technology and then cemented to zirconia hybrid-abutments (Ti-based). Each group was divided into two subgroups (n=10): (A) control group, crowns were subjected to single load to fracture; (B) test group, crowns underwent chewing simulation using multiple loads for 1.2 million cycles at 1.2 Hz with simultaneous thermocycling between $5^{\circ}C$ and $55^{\circ}C$. Data was statistically analyzed with one-way ANOVA and a Post-Hoc test. RESULTS. All tested crowns survived chewing simulation resulting in 100% survival rate. However, wear facets were observed on all the crowns at the occlusal contact point. Fracture load of monolithic lithium disilicate crowns was statistically significantly lower than that of monolithic zirconia crowns. Also, fracture load was significantly reduced in both of the all-ceramic materials after exposure to chewing simulation and thermocycling. Crowns of all test groups exhibited cohesive fracture within the monolithic crown structure only, and no abutment fractures or screw loosening were observed. CONCLUSION. When supported by implants, monolithic zirconia restorations cemented to hybrid abutments withstand masticatory forces. Also, fatigue loading accompanied by simultaneous thermocycling significantly reduces the strength of both of the all-ceramic materials. Moreover, further research is needed to define potentials, limits, and long-term serviceability of the materials and hybrid abutments.

Correction of Persistent Enophthalmos after Surgical Repair of Blow Out Fracture Using Orbital Decompression Technique of Contralateral Eye (안와골파열골절 정복술 후 지속되는 안구함몰 환자에서 정상측 안구의 안구 감압술의 치험례)

  • Lee, Jun-Ho;Park, Won-Yong;Nam, Hyun-Jae;Kim, Yong-Ha
    • Archives of Craniofacial Surgery
    • /
    • v.9 no.2
    • /
    • pp.101-104
    • /
    • 2008
  • Purpose: Diplopia and cosmetically unacceptable enophthalmos are the major complications of blow out fracture. Prolapse of orbital tissue into the sinuses, enlarged orbital volume, atrophy of orbital fat and loss of support of orbital walls play a role in the pathogenesis of enophthalmos. To correct post-traumatic enophthalmos, freeing of incarcerated orbital contents combined with reduction of bony orbital volume and reconstruction of suspensory support of globe is necessary. But remained enophthalmos after surgical treatment is difficult to correct completely. In this case, the authors performed implant insertion for affected orbit and endoscopic orbital decompression for unaffected orbit for correction of late enophthalmos. Method: We reviewed a girl patient with right inferomedial orbital wall blow out fracture, right zygoma fracture treated at our hospital for correction of enophthalmos. An 18-year-old female had sustained posttraumatic enopthalmos. Two surgical management was performed for correction blow out fracture at the other hospital. But residual diplopia, enophthalmos, cheek drooping were found. And then she transferred to our hospital. She had severe enophthalmos(5 mm) also had diplopia and extraocular muscle limitation. We performed operation for correction of enophthalmos. After operation, she showed minimal improvement of diplopia and enophthalmos(3 mm). The authors make plan for operation for correction enophthalmos due to cosmetical improvement. Implant insertion was performed for affected orbit. For unaffected orbit, nasoendoscopic medial orbital wall decompression was proceeded. Result: Correction of enophthalmos was found after operation and was maintained for nine years follow-up. Patient expressed satisfaction for the result. Conclusion: To correct persistant enophthalmos, we could have satisfactory result with orbital wall reconstruction on affected eye and decompression on unaffected eye.

Implementation of curved type a metallic plate system at the Bone contact (골 접촉 곡선형 금속 고정 시스템 구현)

  • Kim, Jeong-Lae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.5
    • /
    • pp.285-292
    • /
    • 2007
  • This study was developed the metallic plate for fixation in the femur fracture for the orthopedic region and rigid fixation with plates has a firm place in fracture treatment. Most plates can be used for rigid as well as biological and dynamical fracture fixation. The device's designation and sizing has a specific with bending structural stiffness and strength, known meaning that is reliable regardless of the plate by the short type and long type. Short plate have a wrapping of femur and long plate have to preserve a pole of femur. The bending strength of the curved metallic long plate has to evaluate a 11,000N and The bending strength of the curved metallic short plate has to evaluate a 6,525N. The tensile stress through to press a plate is $1573N/m^2\;and\;1539N/m^2$. The device can be used to support Revision case of Hip Implant and to use a case of Hip screw compression of Hip Neck Fracture.

  • PDF

A retrospective study of the long-term survival of RESTORE® dental implants with resorbable blast media surface

  • Keun-Soo Ryoo;Pil-Jong Kim;Sungtae Kim;Young-Dan Cho;Young Ku
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.6
    • /
    • pp.444-452
    • /
    • 2023
  • Purpose: The aim of this study was to retrospectively evaluate the survival and failure rates of RESTORE® implants over a follow-up period of 10-15 years at a university dental hospital and to investigate the factors affecting the survival rate of these dental implants. Methods: A total of 247 RESTORE® dental implants with a resorbable blast media (RBM) surface inserted in 86 patients between March 2006 and April 2011 at the Department of Periodontology of Seoul National University Dental Hospital were included. Patients with follow-up periods of less than 10 years were excluded, and data analysis was conducted based on dental records and radiographs. Results: Over a 10- to 15-year period, the cumulative survival rate of the implants was 92.5%. Seventeen implants (6.88%) were explanted due to implant fracture (n=10, 4.05%), peri-implantitis (n=6, 2.43%), and screw fracture (n=1, 0.4%). The results of univariate regression analysis using a Cox proportional hazards model demonstrated that implants placed in male patients (hazard ratio [HR], 4.542; 95% confidence interval [CI], 1.305-15.807; P=0.017) and implants that supported removable prostheses (HR, 15.498; 95% CI, 3.105-77.357; P=0.001) showed statistically significant associations with implant failure. Conclusions: Within the limitations of this retrospective study, the RESTORE® dental implant with an RBM surface has a favorable survival rate with stable clinical outcomes.

Rapid Prototyping and Reverse Engineering Application for Orthopedic Surgery Planning

  • Ahn Dong-Gyu;Lee Jun-Young;Yang Dong-Yol
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.19-28
    • /
    • 2006
  • This paper describes rapid prototyping (RP) and reverse engineering (RE) application for orthopedic surgery planning to improve the efficiency and accuracy of the orthopedic surgery. Using the symmetrical characteristics of the human body, CAD data of undamaged bone of the injured area are generated from a mirror transformation of undamaged bone data for the uninjured area. The physical model before the injury is manufactured from Poly jet RP process. The surgical plan, including the selection of the proper implant, pre-forming of the implant and decision of fixation positions, etc., is determined by a physical simulation using the physical model. In order to examine the applicability and efficiency of the surgical planning technology, two case studies, such as a distal tibia comminuted fracture and an iliac wing fracture of pelvis, are carried out. From the results of the examination, it has been shown that the RP and RE can be applied to orthopedic surgical planning and can be an efficient surgical tool.

Fracture behavior modeling of a 3D crack emanated from bony inclusion in the cement PMMA of total hip replacement

  • Mohamed, Cherfi;Abderahmane, Sahli;Benbarek, Smail
    • Structural Engineering and Mechanics
    • /
    • v.66 no.1
    • /
    • pp.37-43
    • /
    • 2018
  • In orthopedic surgery and in particular in total hip arthroplasty, the implant fixation is carried out using a surgical cement called polymethylmethacrylat (PMMA). This cement has to insure a good adhesion between implant and bone and a good load distribution to the bone. By its fragile nature, the cement can easily break when it is subjected to a high stress gradient by presenting a craze zone in the vicinity of inclusion. The focus of this study is to analyze the effect of inclusion in some zone of cement in which the loading condition can lead to the crack opening leading to their propagation and consequently the aseptic loosening of the THR. In this study, the fracture behavior of the bone cement including a strange body (bone remain) from which the onset of a crack is supposed. The effect of loading condition, the geometry, the presence of both crack and inclusion on the stress distribution and the fracture behavior of the cement. Results show that the highest stresses are located around the sharp tip of bony inclusion. Most critical cracks are located in the middle of the cement mantle when they are subjected to one leg standing state loading during walking.

Investigation into the Development of Technology for Orthopeadic Surgery Utilizing Reverse Engineering and Rapid Prototyping Technology (역공학과 쾌속조형공정을 이용한 정형외과수술기법 개발에 관한 연구)

  • 안동규;이준영;양동열;한길영
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.6
    • /
    • pp.188-196
    • /
    • 2004
  • The objective of this paper is to propose a new technology of the orthopaedic surgery using the combination of reverse engineering (RE) based on CT data and rapid prototyping (RP). The proposed technology utilizes symmetrical characteristics of the human body and capability of the combination of RE and RP, which rapidly manufactures three-dimensional parts from CT data. The original .stl data of injured extents are generated from the mirror transformation of .stl file fur uninjured extents. The physical shape before injuring is manufactured from RP using the original .stl data. Subsequently, pre-operative planning, such as a selection of proper implants, preforming of the implant, a decision of fixation locations and an insert position for the implant, an estimation of the invasive size, and pre-education of operators are performed using the physical shape. In order to examine the applicability and the efficiency of the proposed surgical technology, various case studies, such as a distal tibia commented fracture, a proximal tibia plateau fracture and an iliac wing fracture of pelvis, are carried out. From the results of case studies, it has been shown that the proposed technology is an effective surgical tool of the orthopaedic surgery reducing the operational time, the operational cost, the radiation exposure of the patient and operators, and morbidity. In addition, the proposed technology could improve the accuracy of operation and the speed of rehabilitation.

FIT OF FIXTURE/ABUTMENT/SCREW INTERFACES OF INTERNAL CONNECTION IMPLANT SYSTEM

  • Kim, Jin-Sup;Kim, Hee-Jung;Chung, Chae-Heon;Baek, Dae-Hwa
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.338-351
    • /
    • 2005
  • Statement of problem. Accurate fit between the implant components is important because the misfit of the implant components results in frequent screw loosening, irreversible screw fracture, plaque accumulation, poor soft tissue reaction, and destruction of osseointegration. Purpose. This study is to evaluate the machining accuracy and consistency of the implant fixture/ abutment/screw interfaces of the internal connection system by using a Stereoscopic Zoom microscope and FE-SEM(field emission scanning electron microscope) Materials and methods. The implant systems selected in this study were internal connection type implants from AVANA(Osstem^{\circledR}), Bioplant(Cowell-Medi^{\circledR}), Dio(DIO^{\circledR}), Neoplant(Neobiotech 􀋓), Implantium(Dentium􀋓)systems. Each group was acquired 2 fixtures at random. Two piece type abutment and one piece type abutment for use with each implant system were acquired. Screw were respectively used to hold a two piece type abutment to a implant fixture. The implant fixtures were perpendiculary mounted in acrylic resin block. Each two piece abutment was secured to the implant fixture by screw and one piece abutment also secured to the implant fixture. Abutment/fixture assembly were mounted in liquid unsaturated polyester. All samples were cross-sectioned with grinder-polisher unit. Finally all specimens were analysed the fit between implant fixture/abutment/screw interfaces Results and conclusions. 1. Implant fixture/abutment/screw connection interfaces of internal connection systems made in Korea were in good condition. 2. The results of the above study showed that materials and mechanical properties and quality of milling differed depending on their manufacturing companies.

A study on the fatigue fracture characteristics of TMCP high tensile strength steel welds (TMCP 고장력강 용접부의 피로파양 특성에 관한 연구)

  • 김영식;노재충;한명수;김윤해
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.47-54
    • /
    • 1988
  • TMCP steel manufactured by controlled rolling followed by accelerated cooling process is known to have extra-ordinary mechanical properties such as tensile strength and toughness. However, there is much uncertainty about the fatigue fracture characteristics of this steel. In this paper, the fatigue fracture behaviour of the TMCP steel in base metal and weldment were inspected through the Dynamic Implant test method. Those results were quantitavely compared with those of the ordinary normalized steel of same strength level. Moreover, the effect of the diffusible hydrogen included in the welded part on the fatigue fracture behaviour were made clear. As the experimental results, the fatigue fracture characteristics of the TMCP steel in case of base metal proved out to be superior to that of the normalized steel. However, the TMCP steel weldment including the diffusible hydrogen appeared to have inferior fatigue characteristics compared with the same conditioned normalized steel weldment.

  • PDF