• Title/Summary/Keyword: Implant Treatment

Search Result 1,627, Processing Time 0.037 seconds

Single implant restoration with esthetic prosthodontic treatment in maxillary anterior tooth: A case report (상악 전치부 단일 임플란트의 심미 보철 수복 증례)

  • Kang, Hyeon;Seo, Nu-Ri;Park, Sang-Won;Lim, Hyun-Pil;Yun, Kwi-Dug;Yang, Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.354-359
    • /
    • 2018
  • In a single implant restoration of maxillary anterior teeth, it is difficult to accomplish an aesthetic restoration of the implant prosthesis in the case of gingival recession and bone defect problems. To maintain aesthetic stability in the long term, it is important to place the implant in the ideal position as well as the recovery of the soft tissue and harmony with the prosthesis. Not only ideal implant position but also the harmony with surrounding soft tissues are important to fabricate aesthetic implant prosthesis for these cases. for these cases, a 47- years -old male with lowered level of osseous crest and gingival recession on maxillary anterior tooth was treated with guided bone regeneration and gingival recontouring.

Efficacy of Spinal Implant Removal after Thoracolumbar Junction Fusion

  • Kim, Seok-Won;Ju, Chang-Il;Kim, Chong-Gue;Lee, Seung-Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.43 no.3
    • /
    • pp.139-142
    • /
    • 2008
  • Objective: The purpose of this study was to evaluate the efficacy of spinal implant removal and to determine the possible mechanisms of pain relief. Methods: Fourteen patient~with an average of 42 years (from 22 to 67 years) were retrospectively evaluated. All patients had posterior spinal instrumentation and fusion, who later developed recurrent back pain or persistent back pain despite a solid fusion mass. Patients' clinical charts, operative notes, and preoperative x-rays were evaluated. Relief of pain was evaluated by the Visual Analog Scale (VAS) pain change after implant removal. Clinical outcome using VAS and modified MacNab's criteria was assessed on before implant removal, 1 month after implant removal and at the last clinical follow-up. Radiological analysis of sagittal alignment was also assessed. Results: Average follow-up period was 18 months (from 12 to 25 months). There were 4 patients who had persistent back pain at the surgical site and 10 patients who had recurrent back pain. The median time after the first fusion operation and the recurrence of pain was 6.5 months (from 3 to 13 months). All patients except one had palpation pain at operative site. The mean blood loss was less than 100ml and there were no major complications. The mean pain score before screw removal and at final follow up was 6.4 and 2.9, respectively (p<0.005). Thirteen of the 14 patients were graded as excellent and good according to modified MacNab's criteria. Overall 5.9 degrees of sagittal correction loss was observed at final follow up, but was not statistically significant. Conclusion: For the patients with persistent or recurrent back pain after spinal instrumentation, removal of the spinal implant may be safe and an efficient procedure for carefully selected patients who have palpation pain and are unresponsive to conservative treatment.

Evaluation of Bone Uptake on Tc-99m-MDP in Immediate and Delayed Dental Implants (즉시형과 지연형 치아 임플란트에서 Tc-99m-MDP의 Bone Uptake 평가)

  • 김중현;김명환;이원국;이재영;강성수;최석화
    • Journal of Veterinary Clinics
    • /
    • v.20 no.2
    • /
    • pp.207-211
    • /
    • 2003
  • This investigation aimed to determine the relative merit of osseointegration in immediate and delayed implantation in the dog mandible using radiography and bone scintigraphy. five adult mongrel dogs with a mean weight of 8.5 kg were used in this investigation. During the entire study period. all dogs were fed with a soft commercial diet and water ad libitum to minimize functional loading of the implant. Twenty titanium alloy systems 4 mm in diameter and 10 mm in length blasted with calcium phosphate were prepared for insertion. The second and third left mandibular premolars in each dog were extracted for the delayed implant insertion. Twelve weeks later, the second and third right mandibular premolars were extracted for the immediate implant insertion. Before the delayed and immediate implantation procedures and 0, 4, 8, and 12 weeks after the insertions, radiography and bone scintigraphy were conducted. Bone scans were obtained using a large field of view gamma camera equipped with a collimator about 3 hours after intravenous injection of Tc-99m-MDP to the dogs. All the dogs were evaluated weekly for inflammation, necrosis, and other of the bone or sort tissue. Significant macroscopic lesions were not detected. Radioisotope scintigraphy with Tc-99m-MDP hat proved to be a reliable method for measuring increased bone activity at specific skeleton tissue sites. In conclusion, osseointegration in peri-implant bone did not differ significantly between the immediate and delayed implant procedures during the experimental period. The immediate implant may be an alternative treatment of implant insertion in animals.

THE HISTOLOGIC STUDY OF THE GRAFTED hBMP-I FOR IMMEDIATE IMPLANT FIXATION (발치 후 즉시 임플란트 식립시 이식된 hBMP-I의 조직학적 고찰)

  • Lee, Eun-Young;Kim, Kyoung-Won;Choi, Hee-Won;Um, In-Woong;Chung, Ho-Yong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.4
    • /
    • pp.316-322
    • /
    • 2004
  • A low molecular weight component named bone morphogenetic protein(BMP) chemically isolated from the organic matrix of bone, induce postfetal connective tissue cells surrounding small blood vessels to differentiate into cartilage and bone. The end product of BMP is a spherical ossicle of lamella bone filled with red bone marrow for the functional loading. This is a important point that the graft material is embedded the defect site during the implant surgery. Because present knowledge of the relationship between BMP and bone regeneration arises mainly from studies of induced bone formation in heterotopic sites, it would be helpful to determine whether BMP plays any part in the process of bone healing. The BMPs have been shown to play crucial roles in normal skeletal development as well as bone healing and are able to activate transcription of genes involved in cellular migration, proliferation, and differentiation. The delivery of BMP on matrices has been efficacious in the treatment of defect bone in implant surgery. The purpose of the histologic study was to evaluate the effect of DLB(demineralized lyophilized bone) coated with purified human BMP(hBMP-I) in immediate implant surgery with bony defect to obtain the functional structure of implant asap. The ability of a graft of hBMP-I to accelerate bony defect repair provides a rationale for its use in immediate implant surgery that have large bone defect in edentulous area.

A Study on the heat generation during implant abutment preparation (임플란트 지대주 삭제시의 발생열에 관한 연구)

  • Lee, Ho-Jin;Song, Kwang-Yeob;Jang, Tae-Yeob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.1
    • /
    • pp.27-33
    • /
    • 2003
  • Excessive heat generation at the implant-bone interface may cause irreversible bone damage and loss of osseointegration. The effect of heat generation in vitro at the implant surface caused by abutment reduction with high-speed dental turbine was examined. Titanium-alloy abutments connected to a titanium alloy screw-implant embedded in an acrylic-resin block in a $37^{\circ}C$ water bath were prepared. Temperature changes were recorded via embedded thermocouples at the cervix and apex of the implant surface. Analysis of variance for repeated measures was used to compare seven treatment groups. Fifty seconds of continuous cutting with air and water coolant caused a mean temperature increase of $1.24^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Similar intermittent cutting caused increase of $2.50^{\circ}C$ at apex and $1.64^{\circ}C$ at cervix. But, continuous cutting with air coolant caused a mean temperature increase of $6.47^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Similar intermittent cutting caused increase of $6.47^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Preparation of implant abutment does not lead to detrimental effect on peri-implant tissues provided that adequate cooling. However, without water cooling, extreme overheating could be provoked, reaching the critical temperature that would lead to irreversible bone damage within only a few seconds.

Comparison of implant component fractures in external and internal type: A 12-year retrospective study

  • Yi, Yuseung;Koak, Jai-Young;Kim, Seong-Kyun;Lee, Shin-Jae;Heo, Seong-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.155-162
    • /
    • 2018
  • PURPOSE. The aim of this study was to compare the fracture of implant component behavior of external and internal type of implants to suggest directions for successful implant treatment. MATERIALS AND METHODS. Data were collected from the clinical records of all patients who received WARANTEC implants at Seoul National University Dental Hospital from February 2002 to January 2014 for 12 years. Total number of implants was 1,289 and an average of 3.2 implants was installed per patient. Information about abutment connection type, implant locations, platform sizes was collected with presence of implant component fractures and their managements. SPSS statistics software (version 24.0, IBM) was used for the statistical analysis. RESULTS. Overall fracture was significantly more frequent in internal type. The most frequently fractured component was abutment in internal type implants, and screw fracture occurred most frequently in external type. Analyzing by fractured components, screw fracture was the most frequent in the maxillary anterior region and the most abutment fracture occurred in the maxillary posterior region and screw fractures occurred more frequently in NP (narrow platform) and abutment fractures occurred more frequently in RP (regular platform). CONCLUSION. In external type, screw fracture occurred most frequently, especially in the maxillary anterior region, and in internal type, abutment fracture occurred frequently in the posterior region. placement of an external type implant rather than an internal type is recommended for the posterior region where abutment fractures frequently occur.

Two-short implant supported single molar restoration in atrophic posterior maxilla : a clinical study (위축된 상악구치부에서 두 개의 짧은 임플란트 지지형 단일치관의 임상연구)

  • Song, Ho-Yong;Heo, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of the Korean dental association
    • /
    • v.53 no.9
    • /
    • pp.628-643
    • /
    • 2015
  • Purpose: The aim of this retrospective study was to compare marginal bone loss and survival rates of double short implants(multiple implant) which had been installed and restored in severely atrophic maxillary molar site without a grafting procedure. Material and Method: The subjects were patients (90 patients, 180 implants) who had been installed double short implants in severely atrophic maxillary single molar site without bone augmentation procedure from 2006 to 2014 in dental clinic in Chuncheon city. Following data were collected from dental records and radiographic panoramic views: patient's age, gender, smoking status, implant site, timing of implant installation, residual ridge height. The correlation between those factors and survival rate and marginal bone loss were analyzed. Statistical analysis was performed using Chi-square test, Student's t- test and ANOVA. Result: Eleven implants in 6 patients failed and the cumulative survival rate was 93.9%. No significant differences were found in relation to the following factors: patient's age, gender, implant site, timing of implant installation (P> .05). There were significant differences in smoking status and residual ridge height(P< .05). The average follow-up time was $45{\pm}14.7months$. The mean marginal bone loss of survived 169 implants was $0.08{\pm}0.59mm$. Conclusion: Despite the short term outcomes, the survival rate of double short implants was comparable to normal length implants. This study demonstrated that placement of double short implants without the use of bone grafting procedure for severely atrophic posterior maxilla is a simple and predictable treatment procedure.

Characteristics of contact and distance osteogenesis around modified implant surfaces in rabbit tibiae

  • Choi, Jung-Yoo;Sim, Jae-Hyuk;Yeo, In-Sung Luke
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.3
    • /
    • pp.182-192
    • /
    • 2017
  • Purpose: Contact and distance osteogenesis occur around all endosseous dental implants. However, the mechanisms underlying these processes have not been fully elucidated. We hypothesized that these processes occur independently of each other. To test this, we used titanium (Ti) tubes to physically separate contact and distance osteogenesis, thus allowing contact osteogenesis to be measured in the absence of possible triggers from distance osteogenesis. Methods: Sandblasted and acid-etched (SLA) and modified SLA (modSLA) implants were used. Both types had been sandblasted with large grit and then etched with acid. The modSLA implants then underwent additional treatment to increase hydrophilicity. The implants were implanted into rabbit tibiae, and half were implanted within Ti tubes. The bone-to-implant contact (BIC) ratio was calculated for each implant. Immunohistochemical analyses of bone morphogenetic protein (BMP)-2 expression and new bone formation (Masson trichrome stain) were performed. Results: The implants outside of Ti tubes were associated with good bone formation along the implant surface. Implantation within a Ti tube significantly reduced the BIC ratio (P<0.001). Compared with the modSLA implants, the SLA implants were associated with significantly higher BIC ratios, regardless of the presence or absence of Ti tubes (P=0.043). In the absence of Ti tubes, the bone adjacent to the implant had areas of new bone formation that expressed BMP-2 at high levels. Conclusions: This study disproved the null hypothesis and suggested that contact osteogenesis is initiated by signals from the old bone that undergoes distance osteogenesis after drilling. This signal may be BMP-2.

Comparison of Resorbable and Nonresorbable Membrane for Guided Bone Regeneration in Implant Dehiscence Defects (매식체 주위 열개형 골 결손부의 골 재생시 흡수성 막과 비흡수성 막의 비교)

  • Kwon, Tae-Hoon;Chung, Chin-Hyung;Yim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.323-335
    • /
    • 2000
  • The purpose of this study was to examine the frequency of dehiscence bone defect on peri-implant and to compare the difference between resorbable membrane and nonresorbable membrane in bone regeneration on peri-implant. Amomg the patients, 22 patientswho have recieved an implant surgery at the department of Periodontics in Dankook University Dental Hospital showed implant exposure due to the dehiscence defect and 27 implants of these 22 patients were the target of the treatment. $Gore-Tex^{(R)}$ and $Bio-mesh^{(R)}$ were applied to the patients and treated them with antibiotics for five days both preoperatively and postoperatively. Reentry period was 26 weeks on average in maxilla and 14 weeks on average in mandible. The results were as follows : 1. Dehiscence bone defect frequently appeared in premolar in mandible and anterior teeth in maxilla respectively. 2. Among 27 cases, 2 membrane exposures were observed and in these two cases, regenerated area was decreased. 3. In non-resorbable membrane, bone surface area $9.25{\pm}4.84$ preoperatively and significantly increased to $11.48{\pm}7.52$ postoperatively.(P<0.05) 4. In resorbable membrane, bone surface area was $14.80{\pm}8.25$ preoperatively and meaningfully widened to $17.61{\pm}10.67$ postoperatively.(P<0.05) 5 . The increase of bone surface area in non-resorbable membrane was $2.23{\pm}3.38$ and the increase of bone surface area in resorbable membrane was $2.80{\pm}3.00$ ;therefore, there was no significant difference between these two membranes(P<0.05). This study implies that the surgical method using DFDB and membrane on peri-implant bone defect is effective in bone regeneration regardless the kind of the membrane, and a similar result was shown when a resorbable membrane was used.

  • PDF

Soft tissue reactions around implant-supported single-tooth replacements in the maxillary anterior region (상악 전치부 단일 임플란트 지지 수복금관의 주변 연조직반응의 단면적 연구)

  • Chang, Moon-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.2
    • /
    • pp.321-337
    • /
    • 1998
  • The aims of this study were firstly to investigate soft tissue reactions around single implant-supported crowns and secondly to compare soft tissue dimensions and conditions of the crowns in relation to interdental papillae, and lastly to investigate patients'esthetic satisfaction with their single implant-supported crowns according to the interdental papillae presence/absence. Twenty-nine patients (41 implants) whose single missing tooth in the maxillary anterior region had been replaced by single implant-supported crown participated for the study and various variables of soft tissue conditions, dimensions and crown dimensions were measured around the single implant-supported crowns at clinical examination and from study models and slides. The results showed that the soft tissue conditions around the single implantsupported crowns were similar to those around implants used for partially or totolly edentulous patients. Except for the high frequency of bleeding on probing, all other parameters revealed healthy conditions. The buccal sites of the crown had a shallow pocket comparing with other sites. At all sites of the crown, similar status of little inflammation was found. Mesial sites and central-incisor positioned implantsupported crowns had lower contact point position than distal sites and lateral-incisor positioned crowns, respectively. Mucositis index, probing depth and contact point position were significantly correlated with papillae index(p < 0.05). More inflammation and lower contact point position were found at the implant-supported crown with no interdental space than that with interdental space. Patients showed high esthetic satisfaction regardless of interdental space presence. The result indicated that, despite of their submucosal crown margins, single implantsupported crowns have soft tissue conditions as good as other implants used for the treatment of the different types of edentulism and a clinician can manipulate interdental papilla height by modifying crown shapes within the limits of not violating total esthetics.

  • PDF