• Title/Summary/Keyword: Implant Patient

Search Result 994, Processing Time 0.022 seconds

Single-port robot-assisted prosthetic breast reconstruction with the da Vinci SP Surgical System: first clinical report

  • Joo, Oh Young;Song, Seung Yong;Park, Hyung Seok;Roh, Tai Suk
    • Archives of Plastic Surgery
    • /
    • v.48 no.2
    • /
    • pp.194-198
    • /
    • 2021
  • Robot-assisted nipple-sparing mastectomy with immediate reconstruction is currently performed in an attempt to seek smaller and indistinct incisions. Robotic surgery system has been evolving under the concept of minimal invasive technique which is a recent trend in surgery. One of the latest version is the da Vinci SP Surgical System (Intuitive Surgical). In this report, we will share our experiences. Two patients underwent robot-assisted nipple-sparing mastectomy, each followed by immediate robot-assisted expander insertion and prepectoral direct-to-implant breast reconstruction, respectively. There was no open conversion or major postoperative complication. One patient experienced mild infection, which was resolved by intravenous antibiotic treatment. Simple docking process, multi-joint instruments, and thirdarm functionality are among the new surgical system's advantages. The present cases suggest that robot-assisted nipple-sparing mastectomy with immediate reconstruction using the da Vinci SP Surgical System is feasible and safe. The promising features and potential application of da Vinci SP in breast reconstruction need further study.

Implications of 3-Dimensional Printed Spinal Implants on the Outcomes in Spine Surgery

  • Fiani, Brian;Newhouse, Alexander;Cathel, Alessandra;Sarhadi, Kasra;Soula, Marisol
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.4
    • /
    • pp.495-504
    • /
    • 2021
  • Three-dimensional printing (3DP) applications possess substantial versatility within surgical applications, such as complex reconstructive surgeries and for the use of surgical resection guides. The capability of constructing an implant from a series of radiographic images to provide personalized anatomical fit is what makes 3D printed implants most appealing to surgeons. Our objective is to describe the process of integration of 3DP implants into the operating room for spinal surgery, summarize the outcomes of using 3DP implants in spinal surgery, and discuss the limitations and safety concerns during pre-operative consideration. 3DP allows for customized, light weight, and geometrically complex functional implants in spinal surgery in cases of decompression, tumor, and fusion. However, there are limitations such as the cost of the technology which is prohibitive to many hospitals. The novelty of this approach implies that the quantity of longitudinal studies is limited and our understanding of how the human body responds long term to these implants is still unclear. Although it has given surgeons the ability to improve outcomes, surgical strategies, and patient recovery, there is a need for prospective studies to follow the safety and efficacy of the usage of 3D printed implants in spine surgery.

Dental infection control in clinical practice institutions experienced by dental hygiene students in the COVID-19 situation (코로나바이러스감염증-19 상황에서 임상실습 중 치위생(학)과 학생의 감염관리 인식과 치과의료기관의 감염관리 수행정도)

  • Son, Jung-hui;Jeong, Seo-young
    • Journal of Korean Academy of Dental Administration
    • /
    • v.9 no.1
    • /
    • pp.25-31
    • /
    • 2021
  • The aim of this study was to investigate the level of dental infection control experienced by dental hygiene students in clinical practice institutions to identify problems and improve infection control in dental institutions. This study conducted online surveys targeting 269 dental hygiene students from universities that conducted clinical practice to determine the students' level of awareness regarding dental infection control in dental institutions and the reality of infection control in dental institutions. The results showed that dental hygiene students recognized the need for infection control and education about infection control at a high level. However, only 47% of the students were accurately informed about COVID-19. Basic instruments, periodontal instruments, and implant surgical instruments were sterilized after use for each patient, mostly by the institution, but 3-way syringe tips, preservation instruments and prosthetic instruments were more frequently reused without sterilization immediately after use. For dental infection control to be practiced at dental institutions, it is necessary to establish a systematic and safe infection control system, including infection control education, designation of infection managers, and provision of infection control guidelines.

The humeral suspension technique: a novel operation for deltoid paralysis

  • de Joode, Stijn GCJ;Walbeehm, Ralf;Schotanus, Martijn GM;van Nie, Ferry A;van Rhijn, Lodewijk W;Samijo, Steven K
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.3
    • /
    • pp.240-243
    • /
    • 2022
  • Isolated deltoid paralysis is a rare pathology that can occur after axillary nerve injury due to shoulder trauma or infection. This condition leads to loss of deltoid function that can cause glenohumeral instability and inferior subluxation, resulting in rotator cuff muscle fatigue and pain. To establish dynamic glenohumeral stability, a novel technique was invented. Humeral suspension is achieved using a double button implant with non-resorbable high strength cords between the acromion and humeral head. This novel technique was used in two patients with isolated deltoid paralysis due to axillary nerve injury. The results indicate that the humeral suspension technique is a method that supports centralizing the humeral head and simultaneously dynamically stabilizes the glenohumeral joint. This approach yielded high patient satisfaction and reduced pain. Glenohumeral alignment was improved and remained intact 5 years postoperative. The humeral suspension technique is a promising surgical method for subluxated glenohumeral joint instability due to isolated deltoid paralysis.

Maxillo-mandibular Defect Reconstruction with Bilateral Free Fibula Flaps with Dental Implant Placement and Immediate Loading: A Case Report of the Three-team Approach

  • Nazarian, David;Dikarev, Aleksei;Mokhirev, Mikhail;Zakharov, Georgy;Fedosov, Alexander;Potapov, Maksim;Chernenkiy, Mikhail;Vasilev, Yuriy;Kyalov, Grigoriy;Chausheva, Saniyat;Khachatryan, Arbak;Tevosyan, Artur;Arakelyan, Gevorg
    • Archives of Plastic Surgery
    • /
    • v.49 no.5
    • /
    • pp.652-655
    • /
    • 2022
  • Patients with advanced malignant tumors, including both jaws, is a challenging task for a head and neck surgeon. Current treatment landscape demonstrates good functional, anatomical, and aesthetic results in patients who could previously receive only palliative care. The extensive tissue defects resulting from oncological resections in the head and neck region require immediate reconstruction due to the exposure of vital structures and their contact with the external environment. A patient was operated using a three-team multidisciplinary approach involving simultaneous work of three specialized teams of maxillofacial and reconstructive microsurgeons, as well as an implantologist and a prosthodontist. This approach allowed simultaneous tumor resection with subsequent reconstruction of the intraoperative defect involving bilateral harvesting of two revascularized free fibular osteomusculocutaneous flaps with dental implantation and simultaneous rehabilitation of dentition with crowns.

Total Ankle Arthroplasty Management and Rehabilitation (족관절 인공관절 치환술 후 관리 및 재활)

  • Lee, Kwang-Bok
    • Journal of Korean Foot and Ankle Society
    • /
    • v.26 no.3
    • /
    • pp.118-122
    • /
    • 2022
  • Although total ankle arthroplasty (TAA) has increased considerably in the past ten years, reflecting improvements in implant design and survivorship, the clinical outcomes have been less satisfactory than total hip or total knee arthroplasties. Several issues under debate include postoperative management and rehabilitation in TAA. Especially, there is no consensus or evidence for the most appropriate postoperative management and rehabilitation for patients undergoing TAA. This study was therefore undertaken to suggest appropriate postoperative management and rehabilitation in TAA, after reviewing published articles and focusing on the following topics: prehabilitation, hospital stay, immobilization type and duration, weight-bearing management, pharmacological treatment, and adopted rehabilitation protocols. In previous studies, the postoperative management and rehabilitation proposed depended on the surgeon's preference, the patient's characteristics, and the associated surgical procedures performed after TAA. Nonetheless, our research indicates the best approach is to include a prehabilitation program, immobilization in the early postoperative stage (2~4 weeks), range of motion exercise with partial weight-bearing ambulation, followed by full weight-bearing ambulation after six weeks. Further studies are required to develop a standardized rehabilitation protocol and improve the overall quality of care after TAA.

Single-Port Transaxillary Robot-Assisted Latissimus Dorsi Muscle Flap Reconstruction for Poland Syndrome: Concomitant Application of Robotic System to Contralateral Augmentation Mammoplasty

  • Hwang, Yong-Jae;Chung, Jae-Ho;Lee, Hyung-Chul;Park, Seung-Ha;Yoon, Eul-Sik
    • Archives of Plastic Surgery
    • /
    • v.49 no.3
    • /
    • pp.373-377
    • /
    • 2022
  • Currently, robot-assisted latissimus dorsi muscle flap (RLDF) surgery is used in treating patients with Poland syndrome and for breast reconstruction. However, conventional RLDF surgery has several inherent issues. We resolved the existing problems of the conventional system by introducing the da Vinci single-port system in patients with Poland syndrome. Overall, three patients underwent RLDF surgery using the da Vinci single-port system with gas insufflation. In the female patient, after performing RLDF with silicone implant, augmentation mammoplasty was also performed on the contralateral side. Both surgeries were performed as single-port robotic-assisted surgery through the transaxillary approach. The mean operating time was 449 (335-480) minutes; 8.67 (4-14) minutes were required for docking and 59 (52-67) minutes for robotic dissection and LD harvesting. No patients had perioperative complication and postoperative problems related to gas inflation. The single-port robot-assisted surgical system overcomes the drawbacks of previous robotic surgery in patients with Poland syndrome, significantly shortens the procedure time of robotic surgery, has superior cosmetic outcomes in a surgical scar, and improves the operator's convenience. Furthermore, concurrent application to another surgery demonstrates the possibility in the broad application of the robotic single-port surgical system.

An Image-to-Image Translation GAN Model for Dental Prothesis Design (치아 보철물 디자인을 위한 이미지 대 이미지 변환 GAN 모델)

  • Tae-Min Kim;Jae-Gon Kim
    • Journal of Information Technology Services
    • /
    • v.22 no.5
    • /
    • pp.87-98
    • /
    • 2023
  • Traditionally, tooth restoration has been carried out by replicating teeth using plaster-based materials. However, recent technological advances have simplified the production process through the introduction of computer-aided design(CAD) systems. Nevertheless, dental restoration varies among individuals, and the skill level of dental technicians significantly influences the accuracy of the manufacturing process. To address this challenge, this paper proposes an approach to designing personalized tooth restorations using Generative Adversarial Network(GAN), a widely adopted technique in computer vision. The primary objective of this model is to create customized dental prosthesis for each patient by utilizing 3D data of the specific teeth to be treated and their corresponding opposite tooth. To achieve this, the 3D dental data is converted into a depth map format and used as input data for the GAN model. The proposed model leverages the network architecture of Pixel2Style2Pixel, which has demonstrated superior performance compared to existing models for image conversion and dental prosthesis generation. Furthermore, this approach holds promising potential for future advancements in dental and implant production.

Removable implant-supported partial denture using milled bar with Locator® attachments in a cleft lip & palate patient: A clinical report (구순구개열 환자에서 Locator® 유지장치가 장착된 milled titanium bar를 이용한 가철성 임플란트 피개 국소의치의 보철수복증례)

  • Yang, Sang-Hyun;Kim, Kyoung-A;Kim, Ja-Yeong;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.207-214
    • /
    • 2015
  • Due to the limitations of conventional removable partial denture prostheses to treat a cleft lip & palate patient who shows scar tissue on upper lip, excessive absorption of the maxillary residual alveolar ridge, and class III malocclusion with narrow palate and undergrowth of the maxilla, 4 implants were placed on the maxillary edentulous region and a maxillary removable implant-supported partial denture was planned using a CAD/CAM milled titanium bar. Unlike metal or gold casting technique which has shrinkage after the molding, CAD/CAM milled titanium bar is highly-precise, economical and lightweight. In practice, however, it is very hard to obtain accurate friction-fit from the milled bar and reduction in retention can occur due to repetitive insertion and removal of the denture. Various auxiliary retention systems (e.g. $ERA^{(R)}$, $CEKA^{(R)}$, magnetics, $Locator^{(R)}$ attachment), in order to deal with these problems, can be used to obtain additional retention, cost-effectiveness and ease of replacement. Out of diverse auxiliary attachments, $Locator^{(R)}$ has characteristics that are dual retentive, minimal in vertical height and convenient of attachment replacement. Drill and tapping method is simple and the replacement of the metal female part of $Locator^{(R)}$ attachment is convenient. In this case, the $Locator^{(R)}$ attachment is connected to the milled titanium bar fabricated by CAD/CAM, using the drill and tapping technique. Afterward, screw holes were formed and 3 $Locator^{(R)}$ attachments were secured with 20 Ncm holding force for additional retention. Following this procedure, satisfactory results were obtained in terms of aesthetic facial form, masticatory function and denture retention, and I hereby report this case.

The Long-term Clinical Result of St. Jude Mechanical Valve Replacement (St. Jude 기계판막 치환술의 장기 임상성적)

  • 배윤숙;정성철;김우식;정승혁;유환국;이정호;김병열
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.321-328
    • /
    • 2003
  • Background: The St. Jude Medical prosthesis is one of the popularly used artificial prosthesis, therefore the National Medical Center reports the long-term clinical results of patients who underwent prosthetic valve replacement with St. Jude medical valve for 18 years. Material and Method: Between January, 1984 and June, 2002, a series of 163 consecutive patients who had Implanted St. Jude prosthesis at the National Medical Center were reviewed. Mean age was 42.9$\pm$15.1 years and male to female ratio was 69:94. The operative procedure comprised of 87 MVR, 30 AVR, 45 DVR, and 1 TVR. The reoperative procedure comprised of 21 MVR, 2 AVR, and 14 DVR. Follow-up rate was 96.9%, and cumulative follow-up was 823.8 patient-years. Result: Early mortality rate was 7.9% (13 patients), late mortality rate was 8.7% (13 patients) and late mortality due to valve related complication was 47% (7 patients). Actual survival rate at 10 and 18 years were 91.7$\pm$2.1% and 91.0$\pm$1.9%. Linearized Incidence was as follows: thromboembolism, 1.09%/ patient-year; anticoagulant related hemorrhage, 0.36%/patient-year; valve thrombosis, 0.24%/patient-year; paravalvular leakage, 0.12%/patient-year; and prosthetic bacterial endocarditis, 0.12%/patient-year linearized incidence of over all valve related complication was 1.94%/patient-year. Freedom from valve related complication at 10 and 18 years were 89.1$\pm$3.3% and 88.4$\pm$3.9%. Freedom from valve related death at 10 and 18 years were 95.1$\pm$1.2% and 95.1$\pm$1.0%. Valve related complication was related the age of patient, especially anticoagulant related hemorrhage was more common in patients over 60 years of age. Valve related complication, death were higher in DVR than AVR or MVR, and valve related death was higher in reoperation. There was no relationship between valve related complication or death and implant valve of size. Conclusion: The long-term clinical results of patients implanted with St. Jude Mechanical prosthesis was quite satisfactory with a low incidence of valve related complication and mortality.