• Title/Summary/Keyword: Implant Patient

Search Result 990, Processing Time 0.027 seconds

Metastasis of renal cell carcinoma around suture anchor implants

  • Baek, Samuel;Shin, Myung Ho;Kim, Tae Min;Oh, Kyung-Soo;Lee, Dong Ryun;Chung, Seok Won
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.2
    • /
    • pp.110-113
    • /
    • 2021
  • We present an unusual case of bone metastases from renal cell carcinoma around orthopedic implants in a 78-year-old female with osteolytic, expansile, highly vascularized, malignant infiltration around suture anchors in the proximal humerus. The patient had undergone arthroscopic rotator cuff repair using suture anchor implants 6 years previously. After diagnosis of bone metastasis, she was successfully treated with metastasectomy and internal fixation using a plate and screws, with cement augmentation. This report is the first to document metastases around a suture anchor in a bone and suggests the vulnerability of suture anchor implants to tumor metastasis.

Incidental finding of metastatic malignancy involving the sphenoid sinus on a cone-beam computed tomographic scan: A case report

  • Amintavakoli, Niloufar
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.87-90
    • /
    • 2021
  • The increased use of cone-beam computed tomographic (CBCT) scans has made it increasingly necessary to evaluate incidental findings on CBCT scans. This report describes the case of a 66-year-old female patient who presented to the Department of Oral and Maxillofacial Pathology, Radiology and Medicine at the College of Dentistry of the author's institution and underwent a CBCT scan for maxillary alveolar process implant planning. Upon evaluation of the CBCT scan, a radiopaque (soft tissue attenuation) mass in the left superior aspect of the nasal cavity and left locule of the sphenoid sinus with opacification of the left locule of the sphenoid sinus was incidentally noted. These radiographic findings were suggestive of a space-occupying mass with a high possibility of malignancy. A further medical evaluation confirmed renal cell cancer metastasis to the sphenoid sinus. This study shows the significance of reviewing the entire CBCT scan for incidental findings.

Immediate Loading of Narrow Diameter Implants at the Mandibular Incisor Area Using Full Digital Flow: A Case Report

  • Ahn, Ji Ho;Lim, Young-Jun;Baek, Yeon-Wha;Lee, Jungwon
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.92-99
    • /
    • 2022
  • This case report describes the immediate loading of narrow diameter implants in the mandibular incisor area using full-digital flow. The 3-dimensional position of the implants was planned using digital software, and the corresponding surgical template was fabricated. The implants were inserted immediately after extraction and on the same day, the interim abutment and bridge were placed. At 8 weeks after surgery, the stability of the implants was measured and a digital impression was made using a scan body. Customized titanium abutments and a cement-type full zirconia bridge were delivered. At 36 weeks' follow-up, no clinical or radiographic complications were detected, and the patient was satisfied with the results.

Multidisciplinary Treatment of Persistent Nontuberculous Mycobacterial Spinal Hardware Infection with a Pedicled Superior Gluteal Artery Perforator Flap

  • Tuano, Krystle R.;Yang, Jerry H.;Kleck, Christopher J.;Mathes, David W.;Chong, Tae W.
    • Archives of Plastic Surgery
    • /
    • v.49 no.5
    • /
    • pp.604-607
    • /
    • 2022
  • Nontuberculous mycobacterial hardware infections are extremely challenging to treat. Multidisciplinary care involving removal of infected hardware, thorough debridement, and durable soft tissue coverage in conjunction with antibiotic therapy is essential for successful management. This case report presents a patient with chronic mycobacterial spinal hardware infection that underwent successful treatment with aggressive serial debridements and reconstruction with a large pedicled superior gluteal artery perforator flap coverage.

Implant sample recommendation system that matches patient's tooth color (치아 색에 맞는 임플란트 표본 추천 시스템)

  • Kim, Changjin;Sim, Kyudong;Park, Jong-Il
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2020.11a
    • /
    • pp.305-308
    • /
    • 2020
  • 임플란트 시술 수요가 늘고 시장이 성장하면서 관련 기술도 발전하고 있다. 특히 기능성과 심미성 향상을 위해 많은 기술이 연구되고 있다. 이 중 심미성에 있어 주변 치아와의 색 유사도가 높은 임플란트를 제작하는 것이 주요 연구 중 하나이다. 본 논문에서는 심미성 높은 임플란트 제작을 위해, 다음과 같은 임플란트 표본 추천 시스템을 제안한다. 휴대 조명 장치와 의료용 치아 패치를 사용한 색 보정으로 촬영 환경 차이를 최소화하여 치아의 정확한 색을 추출한다. Mask R-CNN 모델을 통해 보정된 영상에서 치아를 검출하고, 군집화를 통해 색상 단위로 치아 영역을 구분한다. 치아의 영역별 색상과 임플란트 표본 사이의 색상 거리를 계산하여 유사한 표본들을 추천한다. 위 시스템을 통해 사용자는 주변 환경에 영향을 받지 않고, 치아의 색을 정확히 분석하여 이를 임플란트 표본과 비교할 수 있게 된다.

  • PDF

Eustachian tube calcification as an unusual finding on a panoramic radiograph

  • Galal Omami
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.105-107
    • /
    • 2024
  • The author herein presents an unusual case of eustachian tube calcification masquerading as loose radiopacities in the temporomandibular joints on a panoramic image, creating a diagnostic challenge. The patient, a 72-year-old woman, presented to the dental service for implant treatment to improve her masticatory function. A cone-beam computed tomography scan was performed and reviewed by a board-certified oral and maxillofacial radiologist. The scan showed no evidence of calcifications in the temporomandibular joints; however, it revealed nodular calcifications within the cartilaginous portion of the eustachian tube bilaterally. Additionally, this report briefly reviews the differential diagnosis of calcified loose bodies in the temporomandibular joint and provides information that needs to be reinforced periodically.

Immediate Partial Breast and Nipple-Areola Complex Reconstruction Using a Superficial Circumflex Iliac Artery Perforator Flap

  • Gemma Pons;Lucia Sisternas;Jaume Masia
    • Archives of Plastic Surgery
    • /
    • v.51 no.2
    • /
    • pp.150-155
    • /
    • 2024
  • The superficial circumflex iliac artery perforator (SCIP) flap is a versatile flap that has been described for various applications, mostly for lower extremity coverage and head and neck reconstructions. However, there are few publications reporting its use for breast reconstruction, mainly because of its low volume availability. In this article, we present the case of a patient who successfully underwent a partial breast and immediate nipple-areola complex (NAC) reconstruction with an SCIP flap. She had been previously reconstructed with an implant after a nipple-sparing mastectomy, but the NAC turned out to be involved with cancer needing further resection. Our goal with this article, is to introduce a novel concept for addressing partial breast and NAC reconstruction and mostly, to illustrate the importance of an adaptable surgical plan based on every individual case emphasizing the versality of microsurgery for breast cancer reconstruction.

APPLICATION OF CAD/CAM FOR ORAL REHABILITATION IN A PATIENT WITH DOWN SYNDROME (CAD/CAM을 이용한 다운 증후군 환자의 구강 재건)

  • Chung, Hyunjin;Shim, Joon-Sung;Choi, Byung-Jai;Lee, Jae-Ho
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.13 no.2
    • /
    • pp.95-98
    • /
    • 2017
  • Due to hypodontia, poor oral hygiene, and significantly more prevalent periodontal disease, patients with Down syndrome show higher incidence of edentulism. Oral rehabilitation of such patients is imperative but challenging as high rates of prosthesis failure are reported due to malocclusion, high masticatory force, and parafunctional habits. As CAD/CAM(Computer-Aided Design and Computer Aided Manufacturing) is the recent trend in prosthodontics, this report discusses the application of CAD/CAM in a Down syndrome patient. A 25-year-old patient with Down syndrome was presented to the Department of Pediatric Dentistry, Yonsei University Dental Hospital for oral examination. 5 maxillary teeth were missing, 3 were fully impacted, and 4 had grade III mobility. The patient underwent general anesthesia for extraction of impacted and mobile teeth, implant surgery, and final impression for prosthesis. Afterwards, CAD/CAM was used to design and manufacture a 10-unit zirconia bridge. However the bridge was fractured after 18 months due to the patient's bruxism and high masticatory force. Final impression taking, bite registration, cast fabrication, cast scanning, and prosthesis designing were not needed as CAD/CAM data remained. Previous CAD/CAM design was used to remanufacture the zirconia bridge. Down syndrome patients have malocclusion, high masticatory force, and parafunctional habits which increase the possibility of prosthesis fracture. CAD/CAM is beneficial for Down syndrome patients as previous digital records can be utilized for prosthesis repair or remake. In detail, application of CAD/CAM in remanufacturing decreases patient's discomfort of impression taking, shortens and simplifies dental laboratory procedures, and reduces clinician's effort of taking detailed final impressions or accurate bite registration. In conclusion, oral rehabilitation using CAD/CAM provides not only satisfactory levels of comfort, stability, and esthetics, but also easier repair or remake compared to conventional prostheses.

Full-mouth rehabilitation of severely attrited dentition with missing posterior teeth: a case report using digital workflow with jaw motion tracking (심한 교모와 구치부 상실을 보이는 환자의 전악 수복: Jaw motion tracking과 digital workflow를 활용한 증례 보고)

  • Chan Young Park;Younghoo Lee;Seoung-Jin Hong;Janghyun Paek;Kwantae Noh;Ahran Pae;Hyeong-Seob Kim;Kung-Rock Kwon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.293-307
    • /
    • 2023
  • Jaw motion tracking, which is introduced in recent case reports, is a method which records the patient's individualized pathway of the mandibular movements along with facebow transfer, and reproduces the information in the virtual space of computer-aided-design/computer-aided-manufacturing (CAD-CAM) software. In this present case, a collapse of the occlusal plane was observed, due the loss of posterior teeth for a long period. Full-mouth rehabilitation with an increase in the occlusal vertical dimension was planned. First, the patient's mandibular movements were recorded on the newly established jaw relation by jaw tracking, and this information was assembled with the patient's intraoral data to create a virtual patient. Implant planning and diagnostic wax-up was done on the virtual patient, leading the fabrication of the provisional prosthesis. On the newly established jaw relation with an increase in the occlusal vertical dimension, canine guidance of the provisional prosthesis was checked. Finally, the provisional prosthesis was carried out to the definitive prosthesis. Using the advantages of the technologies in the digital dentistry, the patient was satisfied with the function and the esthetics after the treatment.

Design of External Coil System for Reducing Artifact of MR Image due to Implantable Hearing Aid (이식형 보청기에 의한 자기공명 영상의 인공음영 축소를 위한 외부 코일 시스템 설계)

  • Ahn, Hyoung Jun;Lim, Hyung-Gyu;Kim, Myoung Nam;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.375-385
    • /
    • 2016
  • Recently, several implantable hearing aids such as cochlear implant, middle ear implant, etc., which have a module receiving power and signal from outside the body, are frequently used to treat the hearing impaired patients. Most of implantable hearing aids are adopted permanent magnet pairs to couple between internal and external devices for the enhancement of power transmission. Generally, the internal device which containing the magnet in the center of receiving coil is implanted under the skin of human temporal bone. In case of MRI scanning of a patient with the implantable hearing aid, however, homogeneous magnetic fields of the MRI might be interfered by the implanted magnet. For the above reasons, the MR image is degraded by large area of artifact, so that diagnostics are almost impossible in deteriorated region. In this paper, we proposed an external coil system that can reduce the artifact of MR image due to the internal coupling magnet. By finite element analysis estimating area of MR artifact according to varying current and shape of the external coil, optimal coil parameters were extracted. Finally, the effectiveness of the proposed external coil system was verified by confirming the artifact at real MRI scan.