• 제목/요약/키워드: Impedance tube

검색결과 139건 처리시간 0.036초

Development of a Practical Two-Microphone Impedance Tube Method for Sound Transmission Loss Measurement of Sound Isolation Materials

  • Ro, Sing-Nam;Hwang, Yoon;Lee, Dong-Hoon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권3호
    • /
    • pp.105-113
    • /
    • 2003
  • This study developed a practical two-microphone impedance tube method to measure the sound transmission loss of sound isolation materials without the use of an expensive reverberation room or an acoustic intensity probe. In order to evaluate the validation and applicability of the two-microphone impedance tube method, sound transmission losses for several sound isolation materials with different surface density and bending stiffness were measured, and the measured values were compared with the results from the reverberation room method and the theory. From the experimental results, it was found that the accuracy of sound transmission loss obtained by the impedance tube method depends upon the diameter size of the impedance tube (i.e., tested sample size). For sound isolation materials having relatively large bending stiffness such as acryl, wood, and aluminum plates, it was found that the impedance tube method proposed by this study was not valid to measure the sound transmission loss. On the other hand, for sound isolation materials having relatively small bending stiffness such as rubber, polyvinyl, and asphalt sheets, the comparisons of transmission loss between the results from the impedance tube method and the theory showed a good agreement within the range of the frequencies satisfying the normal incidence mass law. Therefore, the two-microphone impedance tube method proposed by this study can be an effective measurement method to evaluate the sound transmission loss for soft sound isolation sheets having relatively small bending stiffness.

차음시트의 음향투과손실 측정에 관한 연구 (A Study on the Sound Transmission Loss Measurement of Sound Isolation Sheets)

  • 이동훈;강문;이주원;정갑철;권영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.409-414
    • /
    • 2000
  • A new impedance tube method is presented for the measurement of transmission loss of sound isolation sheets. The two-microphone method based on the sound decomposition theory proposed by Seybert and Ross is reviewed in this impedance tube method, which has been used for the determination of absorption coefficient of absorptive materials as well as transmission loss of automotive mufflers. Sound transmission losses for rubber, polyvinyl and asphalt sheets are measured in an impedance tube and reverberation room facility, respectively. By comparing two measurement methods, the reliability of impedance tube method used in this study is validated. From the experimental results, it is shown that the accuracy of sound isolation capability obtained by the impedance tube method depends upon the microphone spacing and the distance of the first microphone from the test sample surface.

  • PDF

차음재의 음향투과손실 측정에 Two-Microphone Impedance Tube Method의 적용과 한계 (The Limit and Application of Two-microphone Impedance Tube Method to the Sound Transmission Loss Measurement of Sound Isolation Materials)

  • 이승;안민홍;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.883-888
    • /
    • 2002
  • This study describes the limit and application of the two-microphone impedance tube method to the sound transmission loss measurement of several sound isolation materials with different physical properties. For the sound isolation materials having small flexural rigidity, it is shown that the two-microphone impedance tube method is validated to practically measure the sound transmission loss. For the sound isolation materials having large flexural rigidity, on the other hand, it is found that the two-microphone impedance tube method is no longer valid to measure the sound transmission loss because the regions of resonance and mass law are moved into the higher frequencies. In addition, in order to accurately measure the sound transmission loss of sound isolation materials, their size should be decided based on the consideration of the effect of acoustic excitation on their vibration response.

  • PDF

Impedance audiometry의 임상적 연구 - III. impedance audiometry에 의한 구씨관 기능검사 - (Clinical Study with Impedance Audiometry -Euatachian tube function and impedance audiometry-)

  • 민양기;노관택
    • 대한기관식도과학회:학술대회논문집
    • /
    • 대한기관식도과학회 1976년도 제10차 학술대회연제 순서 및 초록
    • /
    • pp.85.2-85
    • /
    • 1976
  • Harford는 구씨관기능의 측정에 impedance audiometry의 진단학적 가치를 설명한 바 있다. 고막에 천공이 없는 경우 중이강내의 과도한 음압은 tympanogram에 의해 간접적으로 구씨관기능부전을 나타내는 것은 주지의 사실이다. 구씨관기능이 정상인 경우 valsalva maneuver에 의해 고막은 외측으로 밀려나갈 것이며 이것은 balance meter needle의 운동을 야기시킬 것이다. 이에 저자들은 고막, 중이, 구씨관기능이 모두 정상소견을 보이는 사람을 대상으로 valsalva maneuver에 의해 야기될 수 있는 balance meter needle의 운동거리를 측정함으로써 정상인에서의 구씨관에 의한 중이강의 공기체적의 변동양을 조사하였다. 즉, electroacoustic bridge (Madsen ZO 70) with silicone rubber probe tip을 사용하여 고막, 중이, 구씨관기능이 모두 정상인 사람에서 valsalva maneuver에 의한 balance meter needle의 운동범위는 1.0~4.0(평균치 $1.6{\pm}0.06$)이었으며, 그 치가 1.0미만인 경우에는 어떤 정도의 구씨관기능의 저하 내지 부전을 진단할 수 있는 것으로 생각되어 impedance audiometry에 의한 구씨관기능검사의 의의를 고찰하며 보고하는 바이다

  • PDF

맥동관 냉동기에서 관성관의 모델링에 관한 연구 (A study on the modeling of the inertance tube in the pulse tube refrigerator)

  • 남관우;정상권
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.153-156
    • /
    • 1999
  • In this paper, the inertance tube is modeled by the distributed impedance model. This model is verified by the analytical solutions for the long tube without the reservoir. In this model the distributed impedace effect of the inertance tube is included and mass flow rate and pressure distributions are calculated along the inertance tube for various inertance tube lengths. Mass flow rate at the inlet of the inertance tube is also calculated by this model and compared to the lumped impedance method. Mass flow rate by the distributed model shows quite different behaviors from the lumped model when the operating frequency is high and the length of the tube becomes large.

  • PDF

Multi-Termination Technique for the Measurement of Characteristic Impedance and Propagation Constant of Sound Absorbing Materials Using an Impedance Tube

  • Lee, Jong-Hwa;Ih, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • 제25권2E호
    • /
    • pp.79-84
    • /
    • 2006
  • Acoustic characteristics of a sound absorbing material can be identified, if the characteristic impedance and propagation constants are known, which have generally been determined experimentally. One easy method determining these two essential parameters is to measure the one dimensional wave characteristics in the impedance tube. In th udy, the effects of backing conditions on the impedance tube measurement have been examined using several pairs of generally used end conditions. The results showed that the measured values are similar for most pairs of end conditions: however, it was observed that the measured characteristic impedance for different thickness did not agree well for some pairs. In this work, the multi termination method, using three or more known backing con ns, was suggested to reduce such random errors, which are mostly caused by the test procedure. Employing three terminations as a set, comprised of a rigid end, an end with porous material, and an end with a backing cavity, it was demonstrated that improved measured results could be obtained for an open cell PU foam varying widely with three different thicknesses.

금속와이어 흡음재의 흡음성능에 관한 실험적 연구 (An Experimental Study on the Absorption Performance of Steel-Wire Sound Absorbing Materials)

  • 서성원;용호택;이동훈
    • 설비공학논문집
    • /
    • 제15권5호
    • /
    • pp.413-421
    • /
    • 2003
  • The acoustic performances of steel-wire sound absorbing materials with different thicknesses and bulk densities were investigated experimentally. The well-known two-cavity method was used to measure the characteristic impedance, propagation constant and absorption coefficient. The normal absorption coefficients measured by two-cavity method agreed well with those by the two-microphone impedance tube method. The experimental results showed that the magnitude of the absorption coefficient and the frequency range of the maximum absorption coefficient were controllable by changing the thickness and bulk density of the steel-wire. Therefore, the steel-wires obtained from the crushed tire chips could be used as a good absorbing material.

Acoustical Properties and Absorption Performance of Steel-Wire Fabrics

  • Seo, Seong-Won;Kim, Dong-Woo;Lee, Dong-Hoon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권2호
    • /
    • pp.87-96
    • /
    • 2004
  • Acoustic performances of the steel-wire fabrics manufactured from the crushed tires were experimentally investigated for various thicknesses and bulk densities. The well- known two-cavity method was used to measure the characteristic impedances, the propagation constants, and the absorption coefficients. The normal absorption coefficients measured by the two-cavity method agreed well with those measured by the two-microphone impedance tube method. The experimental results showed that the magnitude and frequency range of the absorption coefficient were controllable by changing the thickness and the bulk density of the steel-wire fabrics. Therefore, the steel-wire fabrics from the crushed tires can be successfully used as a good sound absorbing material.

임피던스 관을 이용한 흡음재의 특성 임피던스 측정: 배후조건에 따른 민감도 분석 (Impedance Tube Measurements of Sound Absorbing Materials: Sensitivity Analysis on Backing Conditions)

  • 이종화;이정권;박봉현;김병훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.888-891
    • /
    • 2001
  • Effects of backing conditions on the impedance tube measurement are investigated experimentally, by using several pairs of generally employed end conditions. The results show that the measured values are similar for most of pairs, except the case of using an open pipe condition. In addition, the random error is investigated in the viewpoint of the variation of test conditions. The multi-termination method is suggested for minimizing such a random error.

  • PDF

다공형 배기 소음기의 성능에 관한 연구 (A study on the performance of the perforated tube exhaust muffler)

  • 권영필;이동훈;방정환
    • 오토저널
    • /
    • 제14권6호
    • /
    • pp.48-59
    • /
    • 1992
  • This study is on the performance of the perforated tube muffler when it operates as an exhaust silencer with through-flow, steady or pulsating. Theoretical estimation of the insertion loss was made by means of transfer matrix and by using the impedance equation for the perforated tube obtained for the case of low-speed steady through-flow. Experiment was performed for the measurement of the insertion loss at two flow conditions. The one is a steady flow from the exhaust pipe of an idling diesel engine. The effect of the through-flow velocity and steadiness on the muffler performance was obtained. By comparing the theoretical prediction with the experimental result, the validity of the impedance equation in the theoretical model was discussed. It has been found that steadiness as well as magnitude of the through-flow has a significant effect on the performance of the perforated tube muffler. Especially, the self-noise due to the pulsating flow in the engine exhaust system must be taken into account for the prediction of the muffler performance.

  • PDF