• Title/Summary/Keyword: Impedance transducer

Search Result 152, Processing Time 0.031 seconds

In-plane Vibration Characteristics of Piezoelectric Ring Transducers (링형 압전 변환기의 면내 진동 특성)

  • Piao, Chunguang;Kim, Jin Oh
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.10
    • /
    • pp.780-787
    • /
    • 2014
  • This paper experimentally deals with the vibration characteristics of flat ring transducers used for ultrasonic sensors and actuators. Radial vibration mode, which is the fundamental mode of a thin piezoelectric transducer, was measured by a laser in-plane vibrometer. An impedance analyzer was used to measure natural frequencies. The results measured by experiments verified theoretical predictions. The vibration characteristics of ring transducers were identified according to the outer diameter size. The shape of the fundamental mode is almost uniform but slightly decreases from the inner to the outer circumferential surfaces. The natural frequency of the fundamental mode decreases as the outer diameter increases. It appears that the ring type transducer is suitable to excite uniformly distributed vibration on a flat surface.

Broad-Band Underwater Acoustic Transducer for Doppler Velocity Log (도플러 속도계(DVL)를 위한 광대역 수중 음향 트랜스듀서)

  • Yun, Cheol-Ho;Lee, Yeoung-Pil;Ko, Nak Yong;Moon, Yong-Seon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.9
    • /
    • pp.755-759
    • /
    • 2013
  • A broad-band underwater acoustic transducer that uses thickness vibration mode, derived from a disk type piezoelectric ceramic, has been proposed and designed for DVL (Doppler Velocity Log). Three different types of acoustic transducer were evaluated with respect to the transmitting voltage response, receiving voltage sensitivity and bandwidth of the transducer. The effect of the acoustic impedance matching layer and backing layer is discussed. The results demonstrated that three matching layer with lossy backing layer is the best configuration for underwater transducer. The trial underwater acoustic transducer with three matching layer has a frequency bandwidth of 55%, maximum transmitting voltage response of 200 dB and a maximum receiving voltage sensitivity of -187.3 dB.

Bandwidth Enhancement of Underwater Acoustic Transducer Using a Bandpass Matching Network (대역통과 정합회로를 이용한 수중음향변환기의 대역폭 확장)

  • Lee, Dae-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.52 no.6
    • /
    • pp.702-708
    • /
    • 2019
  • The range resolution of echo sounders can be improved by enhancing the transducer bandwidth. We designed a bandpass matching network for expanding the bandwidth of a transducer by scaling in both impedance and frequency after transforming a lowpass network into a bandpass configuration for a third-order Bessel filter. We measured the effect of the Bessel matching network for a 50 kHz sandwich type transducer on the transmitting voltage response (TVR), receiving sensitivity (SRT) and figure of merit (FOM), using a chirp echo sounder system. Both the simulation and experimental results indicated that the transducer with a bandpass matching network was capable of producing a symmetrical acoustic output over a wider bandwidth (8.25 kHz) than was the transducer without a matching network (3.75 kHz). By implementing the Bessel matching network, we achieved a 120% bandwidth enhancement.

Optimal Structural Design of a Tonpilz Transducer Considering the Characteristic of the Impulsive Shock Pressure (충격 특성을 고려한 Tonpilz 변환기의 최적구조 설계)

  • Kang, Kook-Jin;Roh, Yong-Rae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.11
    • /
    • pp.987-994
    • /
    • 2008
  • The optimal structure of the Tonpilz transducer was designed. First, the FE model of the transducer was constructed, that included all the details of the transducer which used practical environment. The validity of the FE model was verified through the impedance analysis of the transducer. Second, the resonance frequency, the sound pressure, the bandwidth, and the impulsive shock pressure of the transducer in relation to its structural variables were analyzed. Third, the design method of $2^n$ experiments was employed to reduce the number of analysis cases, and through statistical multiple regression analysis of the results, the functional forms of the transducer performances that could consider the cross-coupled effects of the structural variables were derived. Based on the all results, the optimal geometry of the Tonpilz transducer that had the highest sound pressure level at the desired working environment was determined through the optimization with the SQP-PD method of a target function composed of the transducer performance. Furthermore, for the convenience of a user, the automatic process program making the optimal structure of the acoustic transducer automatically at a given target and a desired working environment was made. The developed method can reflect all the cross-coupled effects of multiple structural variables, and can be extended to the design of general acoustic transducers.

Forward-Looking Ultrasound Imaging Transducer : II. Fabrication and Experimental Results

  • Lee, Chankil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.2E
    • /
    • pp.76-84
    • /
    • 1996
  • The experimental testing results of the large-scale version of a forward-looking ultrasound imaging catheter(FLUIC) are presented, along with the fabrication techniques used, experimental methods, and comparisons of the measured and simulated results. The transducer model is verified by measuring the electrical impedance of the transducer. The pulse width, beamwidth, and the dynamic range for both transmit and pulse-echo response of the fabricated FLUIC are also analyzed. The experimental results conformed its forward-looking imaging capability and the sources of discrepancies between the simulated and experimental beam profiles are addressed.

  • PDF

Research for Ultrasonic Transducer Manufacturing and Evaluation Technique (초음파탐촉자(超音波探觸子) 제작(製作) 및 평가기술(評價技術)에 관한 연구(硏究))

  • Yoon, K.S.;Huh, H.;Park, D.Y.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.7 no.1
    • /
    • pp.18-31
    • /
    • 1987
  • For the purpose of domestic production of ultrasonic transducer, experiments on material selection for backing and matching layer, and electrical impedance matching between transducer and equipment were performed. The characteristics of manufactured transducers with experimental results were analyzed and compared with foreign products. Through the evaluation of the transducers manufactured and the comparision with foreign products, it is confirmed that the transducers manufactured show the good performance characteristics and efficiency.

  • PDF

Development of a High-power Ultrasonic System for Sonochemistry Reaction (음향화학 반응용 강력초음파 개발)

  • Lee, Yang-Lae;Kim, Hyun-Se;Baek, Min-Hyuck
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.142-148
    • /
    • 2013
  • High-power ultrasonic promotes a chemical reaction by its own energy, thus it has been used for sonochemistry applications. For example, it has been mostly used for mixing, reaction catalyst, dispersion and disintegration. High-power ultrasonic transducer is made with structure based on a Bolt-clamped Langevin type Transducer (BLT), But it has difficulty in the development because degradation of piezoelectric ceramic by the heat generation of BLT. In this study, for a development of the transducer of 25 kHz and 1000 W used in sonochemistry and industrial cleaning, BLT with a hole in its center and tubular type waveguide of the transducer were designed based on finite element method (FEM). The transducer was fabricated based on the design parameter, and the impedance characteristics are measured experimentally and compared with the numerical results.

Variation in the Vibration Characteristics of a Piezoelectric Transducer due to Pre-pressure (예압에 따른 압전 변환기의 공진특성 변화)

  • Kim, Dae-Seung;Kim, Jin-Oh
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.1 s.106
    • /
    • pp.89-100
    • /
    • 2006
  • This paper presents an analytical approach to describe the variation in the vibration characteristics such as the natural frequency of a piezoelectric transducer under static pre-pressure. The transducer considered in this paper is a bolt-clamped Langevin-type transducer, which consists of a couple of piezoelectric discs, a couple of metal blocks for added mass effect, and a bolt to tighten them. A new analysis model for the transducer has been developed by taking into account the contact area between the piezoelectric ceramic disc and the metal block. The variation of the resonance frequency due to the pre-pressure has been calculated and compared with measured results reported earlier.

Design of Vibrating Transducer for Implantable Middle Ear Hearing Aid (이식형 중이 청각보조기를 위한 진동 트랜스듀서의 설계)

  • 박형욱
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.535-544
    • /
    • 1996
  • In this paper, we analyzed the coil-magnet type vibrating transducer for the implantable middle ear hearing aid which is appropriate for patient's hearing level, and an experimental transducer system is designed For the objective and quantitative analysis of the transducer, a theoretical equivalent model containing coil, magneto and inner ear is developed To perform effective evaluation of the transducer, a transforming ratio Tr is introduced and its range that is suitable for practical implantable middle ear hearing device is foun4 The result of applying physical parameters of ear system to the proposed analytical model shows that frequency response of the coil magrlet type vibrator is predominantly governed by resistive impedance of the coil rather than inertia effect of the magnet and the inner parameters. In addition, we realized an experimental middle ear hearing aid system to show the theoretical validity of designed system and this will provide the basis of the development for actually implantable system.

  • PDF