• 제목/요약/키워드: Impedance to ground

검색결과 450건 처리시간 0.028초

매설지선의 접지임피던스의 주파수의존성에 대한 모사기법 (A Method of Simulating the Frequency-dependent Ground Impedance of Counterpoises)

  • 이복희;신희경;성창훈
    • 조명전기설비학회논문지
    • /
    • 제26권3호
    • /
    • pp.73-79
    • /
    • 2012
  • A counterpoise is commonly employed in grounding systems installing near the ground surface of low resistivity soils and radial-type counterpoises are used in the limited space. Recently some studies on the evaluation of ground impedance of paralleling ground electrodes have carried out, but the data for providing the frequency-dependent ground impedances considering potential interferences are not yet sufficient. In order to provide the information about the design of grounding systems for surge protection, the simulations of the frequency-dependent ground impedance of various shaped counterpoises are carried out by using the distributed parameter circuit model including the effect of potential interferences. This paper presents the theoretical simulations and actual experiments of the frequency-dependent ground impedance of paralleling and 3 or 4-arms star counterpoises. The accuracy of the simulation methodology is examined by the comparison with the measured results, and the results show a good agreement between the simulation and the experiment.

수직 접지면을 갖는 평판형 모노폴 안테나의 임피던스 특성 개선에 관한 연구 (A Study on Improving Impedance Characteristics of Planar Monopole Antenna with Vertical Ground Plane)

  • 정진우;이현진;임영석
    • 대한전자공학회논문지TC
    • /
    • 제48권5호
    • /
    • pp.54-63
    • /
    • 2011
  • 본 논문은 수직 접지면을 갖는 평판형 모노폴 안테나의 임피던스 특성 개선에 관한 논문이다. 평판형 모노폴 안테나의 임피던스 특성 개선을 위해 기존 연구된 방사체 구조 변형 외에 수직 접지면의 영향을 이용하였다. 수직 접지면의 영향을 분석하기 위해 기존 연구인 보조 공진기 모드 이외에 다이폴 안테나 모드를 제안하였다. 수직 접지면의 각 동작 모드를 기반으로, 모노폴 안테나와 수직 접지면 사이의 임피던스 특성 상관관계를 이용하여 평판형 모노폴 안테나의 임피던스 특성을 개선하였다. 개선 방법은 안테나의 급전 위치 변경 및 수직 접지면의 면적 변화이다. 본 분석 결과는 수직 접지면을 갖는 다양한 평판형 모노폴 안테나의 임피던스 특성을 개선 및 분석할 수 있을 것으로 기대 된다.

서지임피던스 측정기의 설계 및 제작 (Design and Fabrication of a Surge Impedance Meter)

  • 길경석;류길수;김일권;문병두;김황국;박찬용
    • 한국철도학회논문집
    • /
    • 제10권6호
    • /
    • pp.645-649
    • /
    • 2007
  • 접지시스템은 고장전류를 대지로 방출시켜 대지전위상승을 억제하는 역할을 한다. 본 논문에서는 넓은 주파수 범위에서 접지임피던스를 분석하기 위하여 서지임피던스측정기를 설계 제작하였다. 본 측정기는 서지발생회로, 고속 샘플/홀드회로 및 주변 전자회로로 구성되어 있으며, 서지발생치고는 상승시간 $50ns\sim500ns$ 범위에서 최대 5kV까지 발생시킬 수 있다. 제작한 서지임피던스 측정기는 심타접지극으로 구성된 접지계에서 실질적 평가가 수행되었다. 실험 결과로부터 접지계의 서지임피던스는 인가전압의 상승시간에 따라 증가하는 경향을 나타내므로, 접지임피던스는 여러가지 고속의 서지파형으로 평가되어야함을 확인하였다.

웨이브렛 변환을 이용한 철도 고압배전선로의 고장검출기법 (Fault Detection Technique in Railway High Voltage Distribution Lines using Wavelet Transform)

  • 정호성;한문섭;이장무;김주락;이한민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1274-1279
    • /
    • 2004
  • This paper proposes technique to detect ground fault in railway high voltage distribution lines. Overcurrent relay technique is widely used for detecting one line ground fault that occurs most frequently in railway high voltage distribution lines. However, ground fault in distribution line is usually high impedance fault with arc. Because the fault current magnitude measured in substation is very small, the conventional overcurrent relay can't detect the high impedance ground fault. Therefore this paper proposes the advanced technique using wavelet transform. It extracts D1 component from fault signals and detects fault comparing magnitude of D1 component in each phase. To evaluate this proposed technique, we model distribution system using PSCAD/EMTDC and extract various fault data. In conclusion this technique can detect ground fault including high impedance fault regardless of fault distance, fault impedance etc.

  • PDF

광대역 접지임피던스 측정기의 설계

  • 박대원;장운용;차현규;길경석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.26-26
    • /
    • 2010
  • Line to ground faults or lightning strikes in electrical power systems produce high frequency overvoltages. With this reason, a wide band analysis of the ground impedance is necessary. In the paper, design of a wideband ground impedance meter which can measure the ground impedance in ranges from 65 Hz to 1.5 MHz is described. Also, a noise elimination method by a digital band-pass filter during measurement is proposed. The maximum measurement error of the meter is estimated 3 % in full ranges.

  • PDF

현장시험에 의한 중성선 고조파 해석용 접지 임피던스 모델링 (The Ground Impedance Modeling for Neutral Harmonic Analysis by Field Tests)

  • 김경철;백승현;최종기;이일무;김종욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.369-371
    • /
    • 2004
  • With the proliferation of nonlinear loads, high neutral harmonic currents in three-phase four-wire distribution system have been observed. It has been. known that the ground impedance has an effect on the neutral currents of a system which operates with harmonics present. On-site measurements of harmonic currents and voltages according to the fell-of-potential method under case study system were made and the ground impedance modeling using the pattern search method for the harmonic analysis was developed. The ground impedance model obtained by the proposed method was compared with the frequency characteristics by field tests and has shown appropriate results, and would be applicable to evaluate the harmonic and transient response characteristics of the ground system.

  • PDF

토양의 이온화영역에서 소규모 접지전극의 과도접지임피던스 특성 분석 (Characteristics Analysis of Transient Impedances of Small-sized Ground Electrodes in a Ionization Region of Soil)

  • 유앙우;엄주홍;조성철;이태형;이복희
    • 조명전기설비학회논문지
    • /
    • 제23권6호
    • /
    • pp.78-84
    • /
    • 2009
  • 본 논문은 토양의 방전 영역에서 소규모 접지전극의 과도접지임피던스의 측정결과를 제시한다. 접지전극 주변에서 이온화 특성을 사실적으르 분석하기 위해서 세 가지 형상의 접지전극을 실외에 설치하고, 고전압 임펄스 발생기를 사용하여 시험전류를 인가하였다. 정지전극에서 대지로 흐르는 전류와 응답 전압을 분석한 결과, 접지전극 주변의 이온화는 높은 대지저항률률의 토양에서 접지임피던스 감소에 기여하며 대지전위상승을 효과적으로 제한하는 것이 확인된다. 하지만 낮은 대지저항률의 토양에서는 이온화 임계전계강도가 작아서 전극 형상이 과도접지임피던스에 거의 영향을 주지 못한다. 그리고 전극형상에 따른 실험결과, 판전극보다 침부봉전극이 이온화 영역 전압범위 내에서 과도접지임피던스 저감에 보다 효과적이다.

Pattern Search 법을 이용한 중성선 고조파 해석용 접지 임피던스 모델링 (The Ground Impedance Modeling using pattern Search Method for Neutral Hormonic Analysis)

  • 백승현;김경철;최종기;이일무;백남웅
    • 조명전기설비학회논문지
    • /
    • 제18권4호
    • /
    • pp.181-187
    • /
    • 2004
  • 3상 4선식 배전계통을 채용하는 우리나라는 비선형 부하의 증가로 중성선에는 많은 중성선 고조파 전류가 관측되고 있다. 또한 접지 임피던스는 고조파가 있는 중성선 전류에 영향 끼친다고 알려져 있다. 전위 강하법에 따라 현장에서 실측한 고조파 전류와 전압을 측정하고, Pattern Search 기법으로 고조파 해석용 접지 임피던스를 모델링 하였다. 여기서 구한 임피던스 모델은 현장 시험에 의한 임피던스 모델과 비교하여 유사한 결과를 얻었고, 접지 시스템의 고조파 및 과도 응답 특성을 평가하는데 활용될 것으로 사료된다.

접지전류의 주파수에 따른 대지표면전위 상승 및 위험전압의 분석 (An Analysis of the Ground Potential Rises and Dangerous Voltages Associated with the Frequency of Ground Currents)

  • 최종혁;조용승;이복희
    • 조명전기설비학회논문지
    • /
    • 제25권4호
    • /
    • pp.97-103
    • /
    • 2011
  • The most important object of grounding systems is to protect human being from electric shock. Touch and step voltages are measured to evaluate the performances of grounding systems. Dangerous voltages have been largely studied by the power frequency fault currents, on the other hand, the ground current containing the high frequency components and surge currents haven't been considered. Many attempts about the grounding impedances reported in these days show that the performance of the grounding systems in high frequency range is very different with the ground resistance. It is necessary to analyze the dangerous voltages formed by the ground currents containing high frequency components. In this paper, the ground surface potential rises near the vertical and horizontal grounding electrodes are measured at the frequency of 100[Hz], 30[kHz], and 100[kHz]. Dangerous voltages are investigated with the frequency-dependent grounding impedance. As a result, the ground surface potential rise is increased as the grounding impedance increases. Touch and step voltages near the grounding electrode whose impedance increases with the frequency are sharply raised.

뇌보호 설비를 위한 접지임피던스 측정기 개발 (Development of Ground Impedance Measuring Instrument for Lightning Protection System)

  • 이태형;조성철;엄주홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.194-195
    • /
    • 2006
  • This study evaluated the impedance characteristics of earth termination system and developed a variable frequency-typed inverter (measuring tool) for the utilization in ground design for lightning protection. The variable-frequency-typed inverter were composed of rectification part, voltage adjuster, IGBT controller and measuring part. Meanwhile, the square wave signal of variable frequency converted its frequency up to lightning surge band by using an IGBT after rectifying an alternating current (AC). It conducted performance evaluation of ground impedance of actual earth termination system by using the developed measuring tool for ground impedance and confirmed that such impedance-oriented performance evaluation was effective in the design of lightning protection.

  • PDF