• Title/Summary/Keyword: Impedance measurement

Search Result 872, Processing Time 0.027 seconds

Reflective Signal Based Signal Contioning of Capacitive Sensor and High Precision Gap Measurement (반사 신호를 이용한 용량 성 센서의 신호처리 및 이를 이용한 초정밀 간극 측정)

  • Kim, Jae-Geun;Lee, Taek-Joo;Lim, Soo-Cheol;Park, Kyoung-Soo;Park, No-Cheol;Park, Young-Pil;Ohm, Won-Suk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.537-537
    • /
    • 2010
  • High precision sensing is very important in various technologies. Especially, it is more important when it were applied to nano/micro meter level's sensing like AFM, storage, etc. And capacitive sensing is widely used method. To improve the measurement efficiency, many signal conditioners were studied and one of them was surface acoustic wave (SAW) device. SAW device is very widely used as a high frequency bandwidth filter. Due to the reflective characteristic of high frequency, the response of SAW device contains both propagative and reflective signal at the external impedance. In this paper, we used SAW device as signal conditioner of capacitive sensor. And high precision gap measurement was executed using capacitive load. Reference signal was reflective SAW response and the magnitude at the center frequency of SAW device by the change of impedance was checked. Finally, the attainable gap resolution was determined.

  • PDF

A.c. Impedance Measurement of CP-Ti in 0.1 M NaOH Solution

  • Moon, Sungmo;Kwon, Mikyung;Kim, Jusuk
    • Journal of Electrochemical Science and Technology
    • /
    • v.3 no.4
    • /
    • pp.185-189
    • /
    • 2012
  • A.c. impedances of mechanically polished CP-Ti specimens were measured at open-circuit potential (OCP) with immersion time and under applied anodic potentials between -0.2 and 1 $V_{Ag/AgCl}$ in 0.1 M NaOH solution. Capacitances of native oxide films ($C_{ox,na}$) grown naturally and capacitances of anodic oxide films ($C_{ox,an}$) formed under applied anodic potentials were obtained to examine the growth of native and anodic oxide films in 0.1 M NaOH solution and how to use $C_{ox,na}$ for the surface area measurement of Ti specimen. $1/C_{ox,na}$ and $1/C_{ox,an}$ appeared to be linearly proportional to OCP and applied potential ($E_{app}$), with proportional constants of 0.086 and 0.051 $uF^{-1}\;V^{-1}$, respectively. The $C_{ox,na}$ also appeared to be linearly proportional to geometric surface area of the mechanically polished CP-Ti fixture specimen, with proportional constants of 11.3 and $8.5{\mu}F\;cm^{-2}$ at -0.45 $V_{Ag/AgCl}$ and -0.25 $V_{Ag/AgCl}$ of OCPs, respectively, in 0.1 M NaOH solution. This linear relationship between $C_{ox,na}$ and surface area is suggested to be applicable for the measurement of real surface area of Ti specimen.

AN IMPROVED ELECTRICAL-CONDUCTANCE SENSOR FOR VOID-FRACTION MEASUREMENT IN A HORIZONTAL PIPE

  • KO, MIN SEOK;LEE, BO AN;WON, WOO YOUN;LEE, YEON GUN;JERNG, DONG WOOK;KIM, SIN
    • Nuclear Engineering and Technology
    • /
    • v.47 no.7
    • /
    • pp.804-813
    • /
    • 2015
  • The electrical-impedance method has been widely used for void-fraction measurement in two-phase flow due to its many favorable features. In the impedance method, the response characteristics of the electrical signal heavily depend upon flow pattern, as well as phasic volume. Thus, information on the flow pattern should be given for reliable void-fraction measurement. This study proposes an improved electrical-conductance sensor composed of a three-electrode set of adjacent and opposite electrodes. In the proposed sensor, conductance readings are directly converted into the flow pattern through a specified criterion and are consecutively used to estimate the corresponding void fraction. Since the flow pattern and the void fraction are evaluated by reading conductance measurements, complexity of data processing can be significantly reduced and real-time information provided. Before actual applications, several numerical calculations are performed to optimize electrode and insulator sizes, and optimal design is verified by static experiments. Finally, the proposed sensor is applied for air-water two-phase flow in a horizontal loop with a 40-mm inner diameter and a 5-m length, and its measurement results are compared with those of a wire-mesh sensor.

Optimization of Measuring Cardiac Output by Both Hands Electrode Impedance Method (양손 전극의 임피던스법을 이용한 심박출량 측정의 최적화)

  • Jung, Sang-O;Sim, Myeong-Heon;Jung, Woon-Mo;Kim, Min-Yong;Yoon, Chan-Sol;Yoon, Hyung-Ro
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1770-1776
    • /
    • 2011
  • In this study, a new method that can estimate ICG data from a subject's both hands to measure Cardiac Output under convenient sensor environment. With this aim, a grip-type electrode was implemented to measure ICG. To improve the accuracy of measurement, the regression equation was extracted using multiple bio-parameters and our result was compared with the thoracic ICG equipment(Physio Flow$^{(R)}$, PF104D, Manatec Biomedical, France), which is being used in clinics. The subjects consist of 26 men and 4 women(age in $22.0{\pm}3.32$). They are no cardiac disease. Parameters available for regression model were used gender, BMI, MBP, LVET, dZ/dt(max), distance between the measured electrodes, body impedance, and PTT. As a result of analyzing the ICG measurement value on thorax and both hands, the correlation with stroke volume, heart rate, and cardiac output was $R^2$=0.853, $R^2$=0.958 and $R^2$=0.899, respectively.

Measurement of the Biological Active Point using the Bio-electrical impedance analysis based on the Adaptive Frequency Tracking Filter (적응주파수추적필터기반의 생체임피던스분석을 통한 생물학적활성점측정에 관한 연구)

  • Park, Hodong;Lee, Kyoungjoung;Yeom, Hojun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.6
    • /
    • pp.109-114
    • /
    • 2013
  • The biological active points (BAP) are known as low resistance spots or good electro-permeable points. In this paper, a new method for BAP detection using the bio-impedance measurement system based on the adaptive frequency tracking filter (AFTF) and the transition event detector is presented. Also, the microcontroller process continuous time demodulation of the modulated signal by multi frequency components using the AFTF. The transition event detector based on the phase space method is applied about each frequency using the BAP equivalent model which is proposed.

Electrical characteristics of $Al_2O_3$ added ZnO ($Al_2O_3$가 첨가된 ZnO의 전기적 특성)

  • 최우성;소병문;홍진웅
    • Electrical & Electronic Materials
    • /
    • v.9 no.6
    • /
    • pp.572-577
    • /
    • 1996
  • Alternating current and direct current of pure, ball milled, and $Al_{2}$O$_{3}$ added ZnO were investigated by means of complex impedance measurement and voltage-current source measurement unit. The electrical conductivity of A1$_{2}$O$_{3}$ added ZnO samples increases when the content of A1$_{2}$O$_{3}$ is used within 1 at% and decreases when it's used more than that. The increase and decrease of electrical conductivity seem to be the donor effect of $Al_{2}$O$_{3}$ and the increase of the number of ZnO grains, respectively. Impedance spectrum seems to be one semircicle. The size of semicircle increase with increasing the A1$_{2}$O$_{3}$ contents. The calculated dielectric constant(at 50.deg. C) were about 70-140 at the peak of the semicircle. The semicircles seem not to be the resistance of ZnO grain as compared to that of 10 for pure ZnO.

  • PDF

Prediction of the Radiated Noise from the Vehicle Intake System (자동차 흡기계의 방사소음 예측에 대한 연구)

  • Kim, Hoi-Jeon;Ih, Jeong-Guon;Lee, Seong-Hyun;Shinoda, K.;Kitahara, S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.105-108
    • /
    • 2005
  • The radiated noise from the automotive intake system should be predicted at the design stage. To this end, the precise measurement of in-duct acoustic source parameters of the intake system, i.e., the source strength and source impedance, is essential. Most of previous works on the measurement of acoustic source parameters were performed under a fixed engine speed condition. However, the requirement of vehicle manufacturer is the noise radiation pattern as a function of engine speed. In this study, the direct method was employed to measure the source parameters of engine intake system under a fixed engine speed and engine run-up condition. It was noted that the frequency spectra of source impedance hardly changes with varying the engine speed. Thus, it is reasonable to calculate the source strength under the engine run-up condition by assuming that source impedance is invariant with engine speed. Measured and conventional source models, i.e., constant pressure source, constant velocity source, and non-reflective source, were utilized to predict insertion loss and radiated sound pressure level. A reasonable prediction accuracy of radiated sound pressure level spectra from the intake system was given in the test vehicle when using the measured source characteristics which were acquired under the operating condition.

  • PDF

Effect of Hydrofluoric Acid on the Electrochemical Properties of Additive Manufactured Ti and Its Alloy (적층가공된 티타늄 합금의 전기화학적 특성에 미치는 불산의 영향)

  • Kim, K.T.;Cho, H.W.;Chang, H.Y.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.166-175
    • /
    • 2018
  • In this study, the electrochemical properties of CP-Ti (commercially pure titanium) and Ti-64 (Ti-6Al-4V) were evaluated and the effect of hydrofluoric acid on corrosion resistance and electrochemical properties was elucidated. Additive manufactured materials were made by DMT (Directed Metal Tooling) method. Samples were heat-treated for 1 hour at $760^{\circ}C$ and then air cooled. Surface morphologies were studied by optical microscope and SEM. Electrochemical properties were evaluated by anodic polarization method and AC-impedance measurement. The oxide film formed on the surface was analyzed using an XPS. The addition of HF led to an increase in the passive current density and critical current density and decreased the polarization resistance regardless of the alloys employed. Based on the composition of the oxide film, the compositional difference observed by the addition of HF was little, regardless of the nature of alloys. The Warburg impedance obtained by AC-impedance measurement indicates the dissolution of the constituents of CP-Ti and Ti-64 through a porous oxide film.

Design and Implementation of a Blood-Glucose Meter to Reduce Hematocrit Interference (적혈구 용적률 간섭 보정을 위한 혈당 측정 기기의 설계 및 구현)

  • Cho, Hyuntae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.15 no.4
    • /
    • pp.167-175
    • /
    • 2020
  • A blood-glucose meter is one of the in vitro diagnostic devices to measure and control the glucose concentration of diabetics. In order to measure the glucose level in the blood, the common method is to measure the amount of electrons, that is, the output current generated by glucose oxidation after a blood sample is inserted into the test strip containing an enzyme. The hematocrit is an obstacle in measuring accurate blood glucose concentration. This paper deals with the design and implementation of a blood-glucose meter to correct the hematocrit interference. We propose a sequential method which measures impedance using the alternating current and then measures glucose in the blood using the direct current. In addition, this paper introduces how to use commercial glucose strips based on the proposed system. Finally, we conducted the performance evaluation of the proposed system by comparing the measured current and impedance with those of the references. As a result, the standard deviation of the current measurement is approximately 0.6nA and the impedance measurement error for measuring the hematocrit is approximately within 1%. The proposed system will improve the accuracy of the conventional blood-glucose meter by reducing the hematocrit interference.

Single Phase Inverter High Frequency Circuit Modeling and Verification for Differential Mode Noise Analysis (차동 노이즈 분석을 위한 단상 인버터 고주파 회로 모델링 및 검증)

  • Shin, Ju-Hyun;Seng, Chhaya;Kim, Woo-Jung;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.3
    • /
    • pp.176-182
    • /
    • 2021
  • This research proposes a high-frequency circuit that can accurately predict the differential mode noise of single-phase inverters at the circuit design stage. Proposed single-phase inverter high frequency circuit in the work is a form in which harmonic impedance components are added to the basic single-phase inverter circuit configuration. For accurate noise prediction, parasitic components present in each part of the differential noise path were extracted. Impedance was extracted using a network analyzer and Q3D in the measurement range of 150 kHz to 30 MHz. A high-frequency circuit model was completed by applying the measured values. Simulations and experiments were conducted to confirm the validity of the high-frequency circuit. As a result, we were able to predict the resonance point of the differential mode voltage extracted as an experimental value with a high-frequency circuit model within an approximately 10% error. Through this outcome, we could verify that differential mode noise can be accurately predicted using the proposed model of the high-frequency circuit without a separate test bench for noise measurement.