• Title/Summary/Keyword: Impedance estimation

Search Result 208, Processing Time 0.041 seconds

Detection of Distinctive Points in Impedance Cardiogram during Exercise by Cross-Correlation Method (상호상관 관계를 이용한 운동중의 임피던스 파형에서의 특성점 검출)

  • 오인식;송철규
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.4
    • /
    • pp.261-266
    • /
    • 1991
  • As the ensemble averaged dz/dt signal during exercise gets smoothed, it is difficult to find the distinctive marks for estimation of stroke volume. The cross correlation function was made use of estimating these marks for automatic calculation by computer from the ensemble averaged dz/dt signal. LVET( Left Ventricular Ejection Time) and stroke volume were estimated based on the calculated parameters from the characteristic points. LVET, stroke volume calculated by hand, by the ensemble average and the cross correlation were compared for accuracy validation.

  • PDF

Estimation of setting times of concrete using piezoelectric sensor (압전센서를 이용한 콘크리트의 응결시간 추정)

  • Lee, Jun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.99-100
    • /
    • 2021
  • In this study, the setting times of concrete was evaluated using the electro-mechanical (EMI) behavior of piezoelectric sensor embedded in the concrete. Penetration resistance test was also performed to compare with EMI sensing technique. As a result, the setting times of concrete can be measured more effectively than penetration resistance test through the EMI sensing technique using the piezoelectric sensor.

  • PDF

Estimation of Distributed and Joint-excited Input Power for Power Flow Analysis (파워흐름해석을 위한 분포가진 및 연결부 가진의 입력파워추정 연구)

  • Kim, Dong-Jin;Hong, Suk-Yoon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.43 no.5 s.149
    • /
    • pp.597-603
    • /
    • 2006
  • The estimations of distributed and joint-excited input power for Power Flow Analysis are accomplished in this paper. Using Fourier transform, the displacements of infinite structures are derived, and the input power of distributed excitation can be estimated. The obtained results compare the real input power with the estimation of input power. When the exciting force acts on the joint of coupled structures, it is estimating the power that is transferred to each structure. Appling this input power, the results of energy density and intensity of Power Flow Analysis can be compared with the classical solutions.

SOC Estimation Algorithm for the Lithium-Ion Battery by Using a Linear State Observer (선형 상태 관측기를 이용한 리튬이온 배터리의 SOC 추정 알고리즘)

  • Tran, Ngoc-Tham;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.60-61
    • /
    • 2014
  • Lithium-Ion batteries have become the best tradeoff between energy, power density and cost of the energy storage system in many portable high electric power applications. In order to manage the battery efficiently State of Charge (SOC) of the battery needs to be estimated accurately. In this paper a model-based approach to estimate the SOC of the Lithium-Ion battery based on the estimation of the battery impedance is proposed. The validity and feasibility of the proposed algorithm is verified by the experimental results.

  • PDF

Estimation of Hand Gestures Using EMG and Bioimpedance (근전도와 임피던스를 이용한 손동작 추정)

  • Kim, Soo-Chan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.194-199
    • /
    • 2016
  • EMG has specific information which is related to movements according to the activities of muscles. Therefore, users can intuitively control a prosthesis. For this reason, biosignals are very useful and convenient in this kind of application. Bioimpednace also provides specific information about movements like EMG. In this study, we used both EMG and bioimpedance to classify the typical hand gestures such as hand open, hand close, no motion (rest), supination, and pronation. Nine able-bodied subjects and one amputee were used as experimental data set. The accuracy was $98{\pm}1.9%$ when 2 bio-impedance and 8 EMG channels were used together for normal subjects. The number of EMG channels affected the accuracy, but it was stable when more than 5 channels were used. For the amputee, the accuracy is higher when we use both of them than when using only EMG. Therefore, accurate and stable hand motion estimation is possible by adding bioimepedance which shows structural information and EMG together.

Thiele Small Parameters Estimation for Pseudo Loudspeaker within 10 mm Grade Circular-type Microspeaker (10 mm급 원형 마이크로스피커의 가상 스피커 TS 매개변수 규명)

  • Park, Seok-Tae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.11
    • /
    • pp.1112-1118
    • /
    • 2007
  • It was discussed to identify Thiele Small Parameters for Pseudo loudspeaker within 10mm grade microspeaker attached to closed-box using known dynamic mass of moving parts. Also, enhanced circuit model for vented-box micro speaker system was used to more accurately simulate electrical impedance curves for real vented-box microspeaker system and compared to test results. Consequently, it showed that micro speaker could be modeled by pseudo loudspeaker TS parameters similar to general loudspeaker. Vented-box microspeaker model with pseudo loudspeaker TS parameters was well suited to describe real microspeaker. Also, it was proposed to estimate volume of rear closed-box of microspeaker without design specifications.

A Numerical Algorithm for Fault Location Estimation Considering Long-Transmission Line (장거리 송전선로를 고려한 사고거리추정 수치해석 알고리즘)

  • Kim, Byeong-Man;Chae, Myeong-Suk;Kang, Yong-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2139-2146
    • /
    • 2008
  • This paper presents a numerical algorithm for fault location estimation which used to data from both end of the transmission line. The proposed algorithm is also based on the synchronized voltage and current phasor measured from the PMUs(Phasor Measurement Units) in the time-domain. This paper has separated from two part of with/without shunt capacitance(short/long distance). Most fault was arc one-ground fault which is 75% over [1]. so most study focused with it. In this paper, the numerical algorithm has calculated to distance for ground fault and line-line fault. In this paper, the algorithm is given with/without shunt capacitance using II parameter line model, simple impedance model and estimated using DFT(Discrete Fourier Transform) and the LES(Least Error Squares Method). To verify the validity of the proposed algorithm, the EMTP(Electro- Magnetic Transient Program) and MATLAB did used.

Multiple Model Adaptive Estimation of the SOC of Li-ion battery for HEV/EV (다중모델추정기법을 이용한 HEV/EV용 리튬이온전지의 잔존충전용량 추정)

  • Jung, Hae-Bong;Kim, Young-Chol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.142-149
    • /
    • 2011
  • This paper presents a new state of charge(SOC) estimation of large capacity of Li-ion battery (LIB) based on the multiple model adaptive estimation(MMAE) method. We first introduce an equivalent circuit model of LIB. The relationship between the terminal voltage and the open circuit voltage(OCV) is nonlinear and may vary depending on the changes of temperature and C-rate. In this paper, such behaviors are described as a set of multiple linear time invariant impedance models. Each model is identified at a temperature and a C-rate. These model set must be obtained a priori for a given LIB. It is shown that most of impedances can be modeled by first-order and second-order transfer functions. For the real time estimation, we transform the continuous time models into difference equations. Subsequently, we construct the model banks in the manner that each bank consists of four adjacent models. When an operating point of cell temperature and current is given, the corresponding model bank is directly determined so that it is included in the interval generated by four operating points of the model bank. The MMAE of SOC at an arbitrary operating point (T $^{\circ}C$, $I_{bat}$[A]) is performed by calculating a linear combination of voltage drops, which are obtained by four models of the selected model bank. The demonstration of the proposed method is shown through simulations using DUALFOIL.

3-D Traveltime and Amplitude Calculation using High-performance Parallel Finite-element Solver (고성능 병렬 유한요소 솔버를 이용한 3차원 주시와 진폭계산)

  • Yang, Dong-Woo;Kim, Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.4
    • /
    • pp.234-244
    • /
    • 2004
  • In order to calculate 3-dimensional wavefield using finite-element method in frequency domain, we must factor so huge sparse impedance matrix. Because of difficulties of handling of this huge impedance matrix, 3-dimensional wave equation modeling is conducted mainly in time domain. In this study, we simulate the 3-D wavefield using finite-element method in Laplace domain by combining high-performance parallel finite-element solver and SWEET (Suppressed Wave Equation Estimation of Traveltime) algorithm which can calculate the traveltime and the amplitude. To verify this combination, we applied it to the SEG/EAGE 3D salt model in serial and parallel computing environments.