• 제목/요약/키워드: Impedance coupling

검색결과 355건 처리시간 0.029초

An Enhanced Power Sharing Strategy for Islanded Microgrids Considering Impedance Matching for Both Real and Reactive Power

  • Lin, Liaoyuan;Guo, Qian;Bai, Zhihong;Ma, Hao
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.282-293
    • /
    • 2017
  • There exists a strong coupling between real and reactive power owing to the complex impedances in droop based islanded microgrids (MGs). The existing virtual impedance methods consider improvements of the impedance matching for sharing of the voltage controlled power (VCP) (reactive power for Q-V droop, and real power for P-V droop), which yields a 1-DOF (degree of freedom) tunable virtual impedance. However, a weak impedance matching for sharing of the frequency controlled power (FCP) (real power for $P-{\omega}$ droop, and reactive power for $Q-{\omega}$ droop) may result in FCP overshoots and even oscillations during load transients. This in turn results in VCP oscillations due to the strong coupling. In this paper, a 2-DOF tunable adaptive virtual impedance method considering impedance matching for both real and reactive power (IM-PQ) is proposed to improve the power sharing performance of MGs. The dynamic response is promoted by suppressing the coupled power oscillations and power overshoots while realizing accurate power sharing. In addition, the proposed power sharing controller has a better parametric adaptability. The stability and dynamic performances are analyzed with a small-signal state-space model. Simulation and experimental results are presented to investigate the validity of the proposed scheme.

진동원으로부터 지지구조물에 전달되는 진동 파워의 추정 - 수평방향으로 전달되는 진동파워의 추정 및 측정 - (Estimation of Vibrational Power Transmitted from Vibration Source to Supporting Structure - Estimation and Measurement of Vibrational Power Transmitted in the Horizontal Direction -)

  • 김재철;주진수
    • 소음진동
    • /
    • 제8권6호
    • /
    • pp.1137-1143
    • /
    • 1998
  • This paper describes the method to measure of the vibrational power transmitted from the vibration source to the supporting structure in the horizontal direction. Generally, it is impossible to measure horizontal forces at the coupling points. However. the vibrational Power transmitted in the horizontal direction can be measured by using indirect method that is based on the mechanical impedance and velocities at the coupling points. We proposed the method to estimate the vibrational power when the vibration source and supporting structure cannot be separated. In this paper. the vibrational power transmitted in the horizontal direction is also estimated by using this method. The estimated and measured results of the mobilities at the coupling point and vibrational power in the horizontal direction are compared. It is shown that the estimated results agree well with the measured results. For the supporting structure with multiple coupling points, the other coupling points should be considered for measuring the vibrational power transmitted through one coupling points. We examine the effects of other coupling points and measure the vibrational power without considering the other coupling points.

  • PDF

Method for Adjusting Single Matching Network for High-Power Transfer Efficiency of Wireless Power Transfer System

  • Seo, Dong-Wook;Lee, Jae-Ho;Lee, Hyungsoo
    • ETRI Journal
    • /
    • 제38권5호
    • /
    • pp.962-971
    • /
    • 2016
  • A wireless power transfer (WPT) system is generally designed with the optimum source and load impedance in order to achieve the maximum power transfer efficiency (PTE) at a specific coupling coefficient. Empirically or intuitively, however, it is well known that a high PTE can be attained by adjusting either the source or load impedance. In this paper, we estimate the maximum achievable PTE of WPT systems with the given load impedance, and propose the condition of source impedance for the maximum PTE. This condition can be reciprocally applied to the load impedance of a WPT system with the given source impedance. First, we review the transducer power gain of a two-port network as the PTE of the WPT system. Next, we derive two candidate conditions, the critical coupling and the optimum conditions, from the transducer power gain. Finally, we compare the two conditions carefully, and the results therefore indicate that the optimum condition is more suitable for a highly efficient WPT system with a given load impedance.

Compact Planar Dual-Wideband Bandstop Filters with Cross Coupling and Open-Ended Stepped Impedance Resonators

  • Velidi, Vamsi Krishna;Sanyal, Subrata
    • ETRI Journal
    • /
    • 제32권1호
    • /
    • pp.148-150
    • /
    • 2010
  • This letter presents the design of a compact bandstop filter (BSF) operating at two frequencies. The proposed BSF consists of open-ended stepped impedance resonators (OSIR) and an end-shorted parallel-coupled microstrip line (E-PCML). The OSIRs are used to achieve the impedance-controlled stopband positions. The wide BSF bandwidths are achieved through enhanced coupling of the E-PCML. Explicit design guidelines are derived using a lossless transmission line model. To validate theoretical predictions, a prototype dual-band BSF operating at 900 MHz and 2,100 MHz with fractional bandwidths of 72% and 36%, respectively, is implemented in microstrip.

진동원으로부터 지지구조물에 전달되는 진동 파워의 추정방법 (Estimation of Vibrational Power Supplied From Vibration Source to Supporting Structure)

  • 김재철;이종원
    • 소음진동
    • /
    • 제8권2호
    • /
    • pp.306-312
    • /
    • 1998
  • This paper proposes a method for estimating the vibrational power supplied by a machine that generates excitation force to its supporting structure via the coupling points. The basis of the method is that the vibrational power can be calculated using the mechanical impedance and the velocity at the coupling points on the supporting structure. First, a method is described to estimate the mobilities at the coupling points when the machine is not separable from the supporting structure, then the vibrational power is calculated using the estimated mobilities and measured velocities at the coupling points. The mobilities are estimated from the result of impulsive testing of the coupled structure. The method is investigated using an experimental model. The estimated and measured values of the mobilities and the vibrational power are compared. It is shown that the estimated values agree well with the measured values.

  • PDF

송전선로에 있어서 Mutual Coupling을 고려한 디지털 거리계전기의 신뢰도 향상 (An Improvement of Digital Distance Relay Reliability considering Mutual Coupling in Transmission Lines)

  • 최석민;이재규;유석구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.1025-1027
    • /
    • 1997
  • In this paper, the digital distance relay of transmission lines under fault conditions is discussed. Distance relay is used to protect transmission lines. The principle of distance relay is well-known ; the impedance measured by a relay is Proportional to the distance from the relay to the fault. Hence, by measuring the impedance, it can be determined whether the line is faulted or not. Unfortunately, the measurement of the fault distance is distorted by Mutual Coupling. To implement more reliable and practical digital distance relay, the mutual coupling effect has to be considered.

  • PDF

측정선의 상호유도작용이 접지임피던스의 측정에 미치는 영향 (Effect of Mutual Coupling Between Test Leads on Ground Impedance Measurement)

  • 이복희;엄주홍;조성철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.71-74
    • /
    • 2003
  • Fall-of-potential method is used usually to measure the ground impedance of large scale grounding system exactly. Because the interlinked magnetic flux between closed loops to inject test current and to measure potential rise is existed in E-P-C straight line arrangement, mutual(or inductive) coupling influences greatly on the measurement correctness. Measurement errors produced from inductive coupling could be reduced by the arrangement methods of auxiliary electrodes. Right angle or P-E-C order arrangement methods were effective to reduce the inductive coupling and the decrease degree of measurement error was analysed as quantitative through an experiment.

  • PDF

IEC 96-1 Line Injection Method를 이용한 다 도체 통신케이블 차폐층의 전달임피던스 측정 (Measurement of Transfer Impedance on Shielded Multiconductor Telecommunication Cables using IEC 96-1 Line Injection Method)

  • 이현영;오호석;박동철
    • 한국전자파학회논문지
    • /
    • 제14권4호
    • /
    • pp.377-383
    • /
    • 2003
  • 동(copper) 케이블을 이용한 xDSL 초고속서비스가 널리 보급됨에 따라 외부 전자파에 의한 통신케이블의 전자파 결합특성을 해hi하기 위해 케이블 쉴드층의 전달임피던스가 중요하게 되었다. 본 논문에서는 xDSL 서비스를 제공하기 위해 사용되는 대표적인 형태의 통신케이블에 대해 IEC 96-1의 line injection method를 이용하여 전달임피던스를 측정하였다. 또한 injection line의 위치, 내부 도체의 위치가 전달임피던스에 어떻게 영향을 주는지를 분석하였으며, 이를 근거로 통신케이블의 전달임피던스 특성 모델을 제시하였다.

Thermal Model for Power Converters Based on Thermal Impedance

  • Xu, Yang;Chen, Hao;Lv, Sen;Huang, Feifei;Hu, Zhentao
    • Journal of Power Electronics
    • /
    • 제13권6호
    • /
    • pp.1080-1089
    • /
    • 2013
  • In this paper, the superposition principle of a heat sink temperature rise is verified based on the mathematical model of a plate-fin heat sink with two mounted heat sources. According to this, the distributed coupling thermal impedance matrix for a heat sink with multiple devices is present, and the equations for calculating the device transient junction temperatures are given. Then methods to extract the heat sink thermal impedance matrix and to measure the Epoxy Molding Compound (EMC) surface temperature of the power Metal Oxide Semiconductor Field Effect Transistor (MOSFET) instead of the junction temperature or device case temperature are proposed. The new thermal impedance model for the power converters in Switched Reluctance Motor (SRM) drivers is implemented in MATLAB/Simulink. The obtained simulation results are validated with experimental results. Compared with the Finite Element Method (FEM) thermal model and the traditional thermal impedance model, the proposed thermal model can provide a high simulation speed with a high accuracy. Finally, the temperature rise distributions of a power converter with two control strategies, the maximum junction temperature rise, the transient temperature rise characteristics, and the thermal coupling effect are discussed.

고속 전력선 통신용 옥내 저전압 전력선 임피던스 측정 및 특성 연구 (Investigation and measurement of indoor low voltage powerline impedance for high data rate powerline communications (PLC))

  • 박영진;김관호
    • 대한전자공학회논문지TC
    • /
    • 제41권8호
    • /
    • pp.93-97
    • /
    • 2004
  • 전력선 통신의 매체인 전력선은 60Hz 전력 공급을 위해 설계되었기 때문에 고속 전력선 통신을 위한 1MHz∼30MHz 대역에서는 전력선은 전기적으로 많은 다른 특징을 갖는다. 따라서 고속 전력선 통신을 위해서는 전력선의 고주파 특성-감쇄 지연, 임피던스-등이 자세하게 분석되고 연구되어야 한다. 본 논문에서는 고속 전력선 통신용 1MHz∼30MHz 주파수 대역 옥내저압 전력선 (220V) 임피던스를 측정하였다. 벡터 회로망 분석기와 저압 전력선 결합 장치(coupling unit)를 이용하여 임피던스를 측정하였다. 결합 장치를 T형 등가회로로 바꾸어, 전체 회로에서 얻은 산란계수를 이용하여 저압 전력선 임피던스를 구했다. 제안된 방법으로 표준 한국형 저층 연립 아파트에 대한 임피던스를 측정하고, 그 특성을 분석하였다. 또한 임피던스 정합을 위하여 평균 임피던스를 구하였고, 측정결과 평균 임피던스는 약 100Ω이었다.