• 제목/요약/키워드: Impedance Measurement

검색결과 872건 처리시간 0.032초

Measurement of the Void Fraction of Slug and Bubbly Flows Using Three-Ring Impedance Meters (3-ring 임피던스미터를 이용한 슬러그류 및 기포류의 기공률 측정)

  • Kim, Jong-Rok;Ahn, Yeh-Chan;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제36권1호
    • /
    • pp.83-88
    • /
    • 2012
  • Real slug and bubbly flows were measured using a three-ring impedance meter that can efficiently measure the void fraction of two-phase flows in a tube. First, the fitting curves between the signal from the impedance meters and the void fraction were found. The impedance meter had different fitting curves for slug and bubbly flows that had the same void fraction. An impedance meter should choose one of the two fitting curves according to the flow pattern, and the flow patterns can be recognized using the measured void fraction. The velocities and sizes of the bubbles were calculated using the void fraction curves measured by two impedance meters.

Surface Modification of Gold Electrode Using Nafion Polymer and Its Application as an Impedance Sensor for Measuring Osmotic Pressure (나피온 폴리머를 이용한 금 전극의 표면 개질 및 이의 삼투압 측정용 임피던스 센서 응용)

  • Min Sik, Kil;Min Jae, Kim;Jo Hee, Yoon;Jinwu, Jang;Kyoung G., Lee;Bong Gill, Choi
    • Applied Chemistry for Engineering
    • /
    • 제34권1호
    • /
    • pp.9-14
    • /
    • 2023
  • In this work, we developed a Nafion polymer-coated impedance sensor with two gold electrode configurations to measure the ion concentration in solution samples. The gold electrodes were fabricated through the sputtering process, followed by surface modification using Nafion polymer. The resulting sensors enable the prevention of the polarization phenomenon on the electrode surface, resulting in stable measurement of electrochemical signals. Spectroscopy and scanning electron microscopy measurements revealed that the thin film of Nafion was coated uniformly onto the surface of the gold electrode. The Nafion-coated sensor exhibited more stable impedance signals than the conventional gold electrode. It showed a highly reliable calibration curve (R2 = 0.983) of the impedance sensor using a standard sodium chloride solution. In addition, a comparison experiment between the impedance sensor and a commercial conductivity sensor was performed to measure the ion concentration of artificial tears, showing similar results for the two sensors.

A Study on The Fat Measurement at Subcutaneous Adipose by Optical and Electrical Method (광전 방식에 의한 피하 지방층의 비만도 측정에 관한 연구)

  • Oh, Se-Yong;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국해양정보통신학회 2008년도 춘계종합학술대회 A
    • /
    • pp.405-407
    • /
    • 2008
  • Body fat measures a large number places body because error is oversized that measure in single specification region to measure body whole body fat degree by non-invasive optical method and bio-electrical impedance method. Use LED source of light that center wavelength is 660nm wavelength and measure at same time by BIA(Bio-electrical Impedance Analysis) method And then photo-electricity method calculate fat correlation formula.

  • PDF

Effects of Electrode and Matrix in the PAFC Performance (전극 및 메트릭스가 인산형 연료전지의 성능에 미치는 영향)

  • Kim, Dong-Jin;Song, Rak-Hyun;Lee, Byung-Rok;Kim, Chang-Soo;Shin, Dong-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1873-1875
    • /
    • 1999
  • The effects of electrode and matrix in the PAFC were investigated using AC-impedance spectroscopy. The performance of PAFC was determined by changing external electronic load. AC impedance measurement was carried out as functions of phosphoric acid impregnation temperature. operating temperature and matrix coating method using various cathodes ; 20%Pt/C, 20%Pt-Ni/C, 20%Pt-Co-Ni/C, 10%Pt-Fe-Co/C, and 20%Pt-Fe-Co/C From the analysis of measured impedance data, the interfacial resistance decreased with increasing operating temperature. and with decreasing impregnation temperature. As compared with the alloy catalysts, Pt catalyst showed a lower interfacial resistance. This consist with the cell performance.

  • PDF

Measurement of Grain Moisture Content using RF Impedance (I) - Electrical Properties of Grain - (고주파 임피던스를 이용한 곡류의 함수율 측정에 관한 연구 (I) - 곡류의 전기적 특성 구명 -)

  • 김기복;노상하
    • Journal of Biosystems Engineering
    • /
    • 제24권2호
    • /
    • pp.123-134
    • /
    • 1999
  • The electrical properties such as dielectric constant, dielectric loss factor and AC conductivity of grain were presented to measure the moisture content of grain using RF impedance. At frequency ranging from 1 to 10MHz and room temperature, $20^{\circ}C$, vector network analyzer(HP4195) and coaxial type sample holder were used to analyze the electrical properties of paddy(11∼24%w.b.), brown rice(11∼18%w.b.), barley(11∼21%w.b.) and wheat(11∼23%w.b.) depending on the moisture content, frequency and bulk density. The dielectric constant and AC conductivity of grain samples increased with moisture content and bulk density. The dielectric constants decreased with frequency and could be expressed as function of the moisture density(decimal moisture $content{\times}bulk$ density).

  • PDF

Boundary estimation in electrical impedance tomography with multi-layer neural networks

  • Kim, Jae-Hyoung;Jeon, Hae-Jin;Choi, Bong-Yeol;Lee, Seung-Ha;Kim, Min-Chan;Kim, Sin;Kim, Kyung-Youn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.40-45
    • /
    • 2004
  • This work presents a boundary estimation approach in electrical impedance imaging for binary-mixture fields based on a parallel structured multi-layer neural network. The interfacial boundaries are expressed with the truncated Fourier series and the unknown Fourier coefficients are estimated with the parallel structure of multi-layer neural network. Results from numerical experiments shows that the proposed approach is insensitive to the measurement noise and has a strong possibility in the visualization of binary mixtures for a real time monitoring.

  • PDF

New negative capacitance front-end for bioimpedance measurements (생체 임피던스 측정을 위한 새로운 네가티브 커패시턴스 프론트 엔드)

  • 권석영;김영필;황인덕
    • Proceedings of the IEEK Conference
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2753-2756
    • /
    • 2003
  • A convenient, tunable loop-gain negative impedance circuit that increases input impedance of a front-end in a bioimpedance measurement has been proposed. Since the proposed circuit comprises wide-band operational amplifiers, selecting operational amplifiers is easy, while an operational amplifier of proper bandwidth should be chosen to use conventional circuit. Also, since loop-gain can be controlled by a feedback resistor connected serially with a feedback capacitor, loop-gain is tunable with a potentiometer. The input impedance of the proposed circuit is two times larger than that of the conventional circuit. Furthermore, closed loop phase response of the proposed circuit is better than that of the conventional circuit or without a negative capacitance circuit. The implemeted, proposed circuit showed stable operation and a zero input capacitance.

  • PDF

Impedance of a Post Mount Structure in the X-band Waveguide (X-밴드 도피관내 지지봉의 임피던스)

  • 박동철;나정웅
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • 제14권1호
    • /
    • pp.29-33
    • /
    • 1977
  • Impedance of a post mount structure supporting a microwave diode in the X-band rectangular waveguide is calculated by using the induced EMF method. Probe measurement of the driving point impedance of the post mounu shows a close agreement with the theoretical calulation when the gap of the post mount is near the bottom wall of the waveguide.

  • PDF

Measurement of Leg Arterial blood volume of Normal Subject Using Impedance Plethysmography (임피던스 혈량측정법을 이용한 일반인의 다리 동맥 혈량 측정)

  • Shim, Young-Woo;Kim, Soo-Chan;Noh, Hyung-Wook;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2008년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.197-198
    • /
    • 2008
  • 본 논문은 Impedance plethysmography를 이용하여 당뇨병 및 동맥경화의 비침습적이고 고통없는 조기 진단을 위한 시스템 구성의 초기 단계로, 하지 동맥의 기계적 특징인 혈량 변화를 비침습적으로 측정하였다. 혈량과 혈압의 변화는 각각 Impedance plethysmograph와 mercury spbygmomanometer를 이용하여 측정되는데 탄성도는 혈량 변화값을 맥압(수축기압)의 변화량으로 나누어 계산한다. 이 논문에서는 하지 동맥의 탄성도를 비침습적으로 측정하기 위한 전초 단계로서 하지 동맥에서의 임피던스 변화만을 측정하였다. 회로는 50kHz Wien bridge 발진 회로, demodulation, 50kHz band past filter, 0.1Hz high pass filter, 20Hz low pass filter와 증폭기로 구성하였고, 생체 신호 획득 및 처리 과정을 거쳐 임피던스 변화량을 관찰하였다.

  • PDF

Forced Resonant Type EMI Dipole Antennas for Frequencies Below 80 MHz

  • Kim, Ki-Chai
    • Journal of electromagnetic engineering and science
    • /
    • 제2권1호
    • /
    • pp.45-49
    • /
    • 2002
  • This paper presents the basic characteristics of a forced resonant type EMI dipole antennas for frequencies below 80 MHz in which two reactance elements are used for the impedance matching at the fined point. The input impedance of the short dipole less than half-wavelength is controlled by the properly determined loading position and the value of loading reactance. The numerical results show that the small-sized EMI dipole antenna with loller antenna factors for frequencies below 80 MHz can be realized by the reactance loading. In case tole proposed center driven forced resonant type EMI dipole antenna with 0.3 λ length is loaded from the center, the input impedance is matched at feed line with 50 $\Omega$, and hence the antenna has lower factors in the frequency range of 30 to 80 MHz.