• Title/Summary/Keyword: Impedance Measurement

Search Result 872, Processing Time 0.023 seconds

Impedance Control for a Vehicle Platoon System (차량 집단 주행 시스템을 위한 임피던스 제어)

  • Yi, Soo-Yeong
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.6
    • /
    • pp.295-301
    • /
    • 2001
  • In this paper, an impedance control using a serial chain of spring-damper system is proposed for a vehicle platoon. For safety of the vehicle platoon, it is required to regulated the distance between each vehicle at a preassigned value even in case of vehicle model error, or moise in the measurement signal. Since the spring-damper system is physically stable and widely used to represent the interaction with the uncertain environments, it is appropriate to the longitudinal control of the vehicle platoon. By considering the nonholonomic characteristics of the vehicle motion, the lateral control and the longitudinal control of the vehicle paltoon are unified in the proposed algorithm. Computer simulation is carried out to verify the robustness against the uncertainties such as the vehicle model error and the measurement noise.

  • PDF

Development of Ultrasonic Transducer for Nondestructive Evaluation of Whole Fruit (과실 비파괴평가용 초음파 변환기 개발)

  • Kim, K.B.;Lee, S.D.;Kim, M.S.
    • Journal of Biosystems Engineering
    • /
    • v.32 no.4
    • /
    • pp.269-275
    • /
    • 2007
  • In this study, ultrasonic transducers for non-destructive contact measurement of whole fruits were developed. The design parameters for ultrasonic transducer such as acoustical impedance of fruits, kinds of piezoelectric materials, ultrasonic wave frequency, and transducer diameter were investigated. In order to match the acoustical impedance between piezoelectric material and fruit, various materials were fabricated and evaluated. Also to control the sensitivity and bandwidth of the ultrasonic transducer, various backing materials were fabricated and evaluated. Especially, the wear plate of the ultrasonic transducer was designed and fabricated considering the curvature of fruit. The central frequencies of two developed ultrasonic transducers were about 100 kHz and 200 kHz, respectively. With the developed ultrasonic transducers, non-destructive evaluation of the fruit will be possible.

Measurements of Cardiac and Respiratory Signals using Impedance Method (임피던스 방법에 의한 심장 및 호흡 신호의 측정)

  • Kim, Hyung-Joong;Shim, Jae-Ok;Jang, Jae-Myeong
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.11
    • /
    • pp.183-186
    • /
    • 1993
  • We have developed a bioimpedance measurement system for impedance cardiography and pneumography. The system injects 50kHz, $200mA_{p-p}$ curreng into the thorax and measures the voltage changes using body surface electrodes. We used the four-electrode method for tile measurement of cardiac singnals and two-electrode method for respiratory signals. We developed a Microsoft Windows program for the acquisition, display, storage, and processing of impedance signals.

  • PDF

The Development of Portable Body Fat Meter (휴대용 체지방계의 개발)

  • Park, Jong-Chan;Lim, Eung-Choon;Park, Su-Hong;Han, Un-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.34-37
    • /
    • 2003
  • The purpose of this paper is the development of portable body fat meter. Bioelectrical impedance method for measuring human body composition is based upon the principle that the electrical conductivity of the fat mass is far greater than that of the fat. Finally measurement of percent body fat was made possible using a developed impedance measuring device which measure impedance between the thumb and ring finger.

  • PDF

A Study on the Compensation of Transducer Effects for the Measurement of Vibration with an Impedance Head (임피턴스헤드로 진동계측시 변환기의 부착영향을 보상하는 방법에 관한 연구)

  • 이현엽;박재영
    • Journal of KSNVE
    • /
    • v.5 no.1
    • /
    • pp.117-122
    • /
    • 1995
  • The transfer matrix method is proposed to compensate the attachment effect of a piezo-electric impedance head. To validate the proposed method, an experiment is carried out for axial vibration of a uniform rod for which an analytical solution is known. The impedance head is attached to the test rod by a stud and is connected to the exciter. The frequency response function is mesured by applying random excitation from the electro-magnetic exciter. The frequency response function compensated by the method proposed in this research shows good agreement with the analytical solution.

  • PDF

Measurement of Setting Times of Steel Fiber Reinforced Mortar using Electric-mechanical Impedance Sensing Technique (전기역학적 임피던스 기법을 이용한 강섬유 보강 모르타르의 응결시간 평가)

  • Lee, Jun Choel;Kim, Wha Jung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.183-184
    • /
    • 2016
  • This study investigated the evolution of electro-mechanical impedance (EMI) of piezoelectricity (PZT) sensor embedded in hydrating steel fiber reinforced mortar to determine the setting times of that. Penetration resistance test was also conducted in order to justify the valid of EMI sensing technique. As a result, the setting times of steel fiber reinforced mortar can be effectively monitored through the EMI sensing technique using PZT sensor.

  • PDF

The Impedance Properties of Poly(p-phenylene)-based Carbon/Li cell (PPP-based Carbon/Li cell의 임피던스 특성)

  • 류현옥;홍성문;김주승;구할본
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.283-285
    • /
    • 1997
  • We have obtained disordered carbon by pyrolyzing PPP in a nitrogen atmosphere for 8 hour at 700$^{\circ}C$. AC impedance property was measured with the PPP-based carbon/EC-DEC/Li cell. The impedance spectra of the cell were measured during the 1st discharge proceed. As the result of measurement the cell resistance decreased in intial discharge, but increase in final discharge.

  • PDF

Development of Pneumography Impedance Based Respiration Measurement System Using Kalman Filter (칼만 필터를 이용한 흉곽 임피던스법 기반의 호흡 신호 계측시스템 개발)

  • Nam, Eun-Hye;Choi, Chang-Hyun;Kim, Yong-Joo;Shin, Dong-Ryeol
    • Journal of Biosystems Engineering
    • /
    • v.33 no.5
    • /
    • pp.326-332
    • /
    • 2008
  • A respiration measurement system for vital signs was developed. Respiration signals were measured, processed, and analyzed. Four electrodes, attached on the surface of the skin, were used to monitor respiration signals by impedance pneumography. The measured signals were amplified, detrended, filtered, and transferred toan embedded module. The Kalman filter was used to remove motion artifact from the respiration signals. Experiments were conducted at stable condition and walking condition to evaluate the performance of the system. Respiration rates of five males and five females were measured and analyzed at each condition. The referenced respiration signal was determined by temperature of nose surroundings. The results showed that the respiration rates at the walking condition had more motion artifacts than the stable condition. The accuracies of the respiration measurement system with Kalman filter were found as 96% at the stable condition and 95% at the walking condition. The results showed that the Kalman filter was an effective tool to remove the motion artifact from the respiration signal.

Construction of the Electrochemical Impedance Measurement System Using Fourier Transform (푸리에 변환을 이용한 전기화학적 임피던스 측정 시스템 제작)

  • Hwang, Eui-Jin;Oh, Sang-Hyub
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.6
    • /
    • pp.713-719
    • /
    • 1991
  • Electrochemical impedance measurement system using Fourier transform was constructed in the range of the frequencies up to 100 kHz. This system consists of pseudo-random noise generator, specially designed potentiostat, fast data acquisition system, system controller, and computer interface. The performance of the constructed system was found to be almost same as the commercially available system using lock-in amplifier. Measuring time was significantly reduced because the minimum time for the measurement depended on one cycle of the lowest frequency used. It would be possible to study time-varying electrochemical impedance systems such as the initial stages of corrosion processes using this system.

  • PDF