• Title/Summary/Keyword: Impedance Boundary Condition

Search Result 51, Processing Time 0.026 seconds

Numerical Analysis of Rail Noise Regarding Surface Impedance of Ground by Using Wavenumber Domain Finite and Boundary Elements (지면 임피던스를 고려한 레일 방사 소음의 파수영역 유한요소/경계요소 해석)

  • Ryue, Jungsoo;Jang, Seungho
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.4
    • /
    • pp.289-300
    • /
    • 2015
  • An important source of noise from railways is rolling noise caused by wheel and rail vibrations induced by acoustic roughness at the wheel-rail contact. In conventional approaches to predicting rail noise, the rail is regarded as placed in a free space so that the reflection from the ground is not included. However, in order to predict rail noise close to the rail, the effect of the ground should be contained in the analysis. In this study the rail noise reflected from the ground is investigated using the wavenumber domain finite element and boundary element methods. First, two rail models, one using rail attached to the rigid ground and one using rail located above rigid ground, are considered and examined to determine the rigid ground effect in terms of the radiation efficiency. From this analysis, it was found that the two models give considerably different results, so that the distance between the rail and the ground is an important factor. Second, an impedance condition was set for the ground and the effect of the ground impedance on the rail noise was evaluated for the two rail models.

Damage detction and characterization using EMI technique under varying axial load

  • Lim, Yee Yan;Soh, Chee Kiong
    • Smart Structures and Systems
    • /
    • v.11 no.4
    • /
    • pp.349-364
    • /
    • 2013
  • Recently, researchers in the field of structural health monitoring (SHM) have been rigorously striving to replace the conventional NDE techniques with the smart material based SHM techniques, employing smart materials such as piezoelectric materials. For instance, the electromechanical impedance (EMI) technique employing piezo-impedance (lead zirconate titanate, PZT) transducer is known for its sensitivity in detecting local damage. For practical applications, various external factors such as fluctuations of temperature and loading, affecting the effectiveness of the EMI technique ought to be understood and compensated. This paper aims at investigating the damage monitoring capability of EMI technique in the presence of axial stress with fixed boundary condition. A compensation technique using effective frequency shift (EFS) by cross-correlation analysis was incorporated to compensate the effect of loading and boundary stiffening. Experimental tests were conducted by inducing damages on lab-sized aluminium beams in the presence of tensile and compressive forces. Two types of damages, crack propagation and bolts loosening were simulated. With EFS for compensation, both cross-correlation coefficient (CC) index and reduction in peak frequency were found to be efficient in characterizing damages in the presence of varying axial loading.

Forced vibration of surface foundation on multi-layered half space

  • Chen, Lin
    • Structural Engineering and Mechanics
    • /
    • v.54 no.4
    • /
    • pp.623-648
    • /
    • 2015
  • A numerical approach is presented for the analysis of the forced vibration of a rigid surface foundation with arbitrary shape. In the analysis, the foundation is discretized into a number of sub squaree-lements. The dynamic response within each sub-element is described by the Green's function, which is obtained by the Fourier-Bessel transform and Precise Integration Method (PIM). Incorporating the displacement boundary condition and force equilibrium of the foundation, it obtains a system of linear algebraic equation in terms of the contact forces within each sub-element. Solving the equation leads to the desired dynamic impedance functions of the foundation. Numerical results are obtained for foundation not only with simple geometrical configurations, such as rectangular and circular foundation, but also the case of irregularly shaped foundation. Several comparisons between the proposed approach and other methods are made. Very good agreement is reached. Also, parametric studies are carried out on the dynamic response of foundation. Addressed in this study are the effects of Poisson's ratio, material damping and contact condition of soil-foundation interface. Several conclusions are drawn the significance of the factors.

Impedance Analysis of Resistance Anomaly of $BaTiO_3$ based PTC thermistor

  • Chun, Myoung-Pyo;Myoung, Seong-Jae;Nam, Joong-Hee;Cho, Jeong-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.182-182
    • /
    • 2009
  • The effect of Re-oxidation on the PTCR properties of Sm-doped barium titanate ceramics was investigated by means of impedance spectroscopy. Electrical properties such as resistance vs. temperature, I-V curve were measured and microstructure was observed with SEM photography. Sample was fabricated with thick film process such as tape casting of green sheet, screen printing of electrode pattern, stacking, firing in reduced atmosphere and re-oxidation, etc. As the temperature of re-oxidation increases, resistance jump as a function of temperature enhances but resistance at room temperature increases. These behavior of resistance as a function of temperature, dependent on the re-oxidation condition, is analyzed with Cole-Cole impedance plot and is shown to be related with the degree of oxidation of grain boundary regardless of grain core during re-oxidation process of sample.

  • PDF

An Analysis of Acoustic Field for Turbo Chiller Discharge Duct by Using Boundary Element Method (경계요소법을 이용한 터보냉동기 덕트의 내부 음향장 해석)

  • 전완호;이준근;정필중
    • Journal of KSNVE
    • /
    • v.10 no.6
    • /
    • pp.963-970
    • /
    • 2000
  • The turbo chiller uses centrifugal compressor, which operates at about 14,500 rpm. Due to the high rpm of the impeller, the noise of chiller males one of the serious problems. The possibility of the sound reduction by using absorbing material is studied in this paper. The generated sound propagates through the duct and then radiates to the outer field. So, the use of sound absorption material inside the duct is one of the effective methods. To study the effect of location of the material, we use Boundary Element Method to analyze the sound field inside the duct system. Numerical study shows the highest sound pressure region is near the elbow of curved duct. From the numerical study, it is also shown that appropriate use of sound absorbing material at this region makes 8dB reduction of the highest noise level.

  • PDF

Modified SDIE MLFMM Method for Inhomogeneous Impedance Material Containing PEC or PMC Region (PEC 또는 PMC 영역을 포함하는 불균일 임피던스 매질의 산란 해석을 위한 수정된 SDIE MLFMM 방법)

  • Lee, Hyunsoo;Koh, Il-Suek;Yoo, Ji Hee
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.10
    • /
    • pp.805-810
    • /
    • 2018
  • A coated perfect electric conductor(PEC) interface to reduce scattered fields can be efficiently modeled by using the impedance boundary condition. The self-dual integral equation(SDIE) proposed by Yan et al. may be an efficient multi-level fast multipole method (MLFMM) formulation for the impedance object. This equation can be applied to an inhomogeneous impedance material, but its accuracy can be degenerated when the material contains a PEC or perfect magnetic conductor(PMC) region. In this paper, we modify the original SDIE formulation for an inhomogeneous object containing a PEC or PMC region and numerically verify its accuracy.

Experimental Investigations for Thermal Mutual Evaluation in Multi-Chip Modules

  • Ayadi, Moez;Bouguezzi, Sihem;Ghariani, Moez;Neji, Rafik
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1345-1356
    • /
    • 2014
  • The thermal behavior of power modules is an important criterion for the design of cooling systems and optimum thermal structure of these modules. An important consideration for high power and high frequency design is the spacing between semiconductor devices, substrate structure and influence of the boundary condition in the case. This study focuses on the thermal behavior of hybrid power modules to establish a simplified method that allows temperature estimation in different module components without decapsulation. This study resulted in a correction of the junction temperature values estimated from the transient thermal impedance of each component operating alone. The corrections depend on mutual thermal coupling between different chips of the hybrid structure. A new experimental technique for thermal mutual evaluation is presented. Notably, the classic analysis of thermal phenomena in these structures, which was independent of dissipated power magnitude and boundary conditions in the case, is incorrect.

Analysis of the Coplanar Waveguide Shielded by Rectangular Waveguide (구형 도파관으로 차폐된 코플래너 도파관 해석)

  • 황정섭;이상설
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.7
    • /
    • pp.19-25
    • /
    • 1993
  • By using the point matching method, the coplanar waveguide shielded by the rectangular waveguide has been analyzed. The particular potential solution of C.P.W has been obtained from the boundary condition by using the point matching method. The line capacitance has been obtained from the total charge of the center conductor per length. The effective dielectric constant and the line impedance have been obtained from the line capacitance of C.P.W.

  • PDF

Scan Element Characteristics of Open-Ended Waveguide Array Antenna (개방형 도파관 배열안테나의 조향소자 특성)

  • Kim, Dong-Seok;Kim, Tae-Hyun;Park, Dong-Chul;Kim, Chan-Hong
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.347-352
    • /
    • 2005
  • Scan Element Pattern(SEP) and Scan Impedance(SI) concepts are used to analyze the characteristics of open-ended waveguide array, which is the representative phased array antenna element in C-band and X-band. Transmit SEP's are calculated for 15$\sim$15 subarray and SI's are obtained by applying periodic boundary conditions for a unit cell of the given array condition. CST's MWS and Ansoft's HFSS are utilized for each analysis. Some relations are reviewed between the two results, which are based on mutual coupling effects. For validation purpose, an 8$\sim$8 subarray is constructed and tested. Transmit SEP measured in MTG's far-field range shows good agreement with the calculated transmit SEP.

  • PDF

Influence of Retrogression and Re-aging on the Exfoliation Corrosion Behavior of AA 7085 Sheets

  • Krishnan, Ajay;Raja, V.S.;Mukhopadhyay, A.K.
    • Corrosion Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.159-165
    • /
    • 2016
  • An attempt has been made to understand the influence of retrogression and re-aging (RRA) on the exfoliation corrosion behaviour of AA 7085 alloy in comparison with the peak aged condition (PA). Immersion tests using ASTM G34 and studies involving electrochemical impedance spectroscopy showed that the RRA treated alloy provided higher resistance to exfoliation corrosion than the PA treated alloy. The improved resistance was attributed to the enhanced Cu content and the discontinuous nature of the grain boundary precipitate, which was revealed through transmission electron microscopy.