• Title/Summary/Keyword: Impedance

Search Result 6,415, Processing Time 0.037 seconds

Analysis on the Effects of the Induced Noise Voltage with the Impedance Changes of Telecommunication Line in the Power Inducting Situation (전력 유도 장애 발생 시 통신 선로의 접지체 임피던스 크기가 유도 잡음 전압에 미치는 영향 분석)

  • Choi, Mun-Hwan;Lee, Sang-Mu;Cho, Pyoung-Dong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.227-230
    • /
    • 2007
  • In this paper, we have analyzed the change characteristics of induced noise due to the impedance change of the ground in both ends of telecommunication line. As what affects the induced noise, there are power influence or longitudinal transverse voltages and its weighted filtered voltage. In the result of measurement, we can see the noise level change due to the change of the ground impedance, that is, as the ground impedance at either end of the telecommunication line become grower, the noise level is increased, and as the ground impedance at either end of the telecommunication line become smaller, the noise level is decreased. However, we can't define the relation between ground impedance size and PIF in these measurement results, so we will have to carry out the measurement more deeply and more practically with various conditions in environmental viewpoint and/or experimental viewpoint to establish the definition between ground impedance size and PIF.

  • PDF

Optimum Electrode Selection for Measuring Abdominal Pressure using Bio-Impedance Method (생체 임피던스 방법을 이용하여 복압을 측정하기 위한 최적 전극위치 선정)

  • Kim, Keo-Sik;Lee, Sang-Ok;Seo, Jeong-Hwan;Kim, Kyeong-Seop;Song, Chul-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1339-1342
    • /
    • 2007
  • In this study, we determined the optimum electrode pair for measuring the abdominal pressure using bio-impedance method and compared with conventional methods. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified using values of impedance change, correlation coefficient and SNR. Our results showed the optimum electrode pair (1, 9) which could detect impedance changes due to an increase of the intensity of the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2+0.0620x+0.6958$, respectively. It demonstrated that the abdominal pressure could be measured noninvasively and simply using bio-impedance method. We propose that this optimum electrode configuration would be useful for future studies involving the convenient measurement of abdominal pressure by ambulatory urodynamics monitoring study.

Electrical Impedance Response Model of Concrete in Setting Process (응결 과정 콘크리트의 전기 임피던스 응답 해석 모델)

  • Shin, Sung Woo;Hwang, Garam;Lee, Chang Joon
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.116-122
    • /
    • 2014
  • Assessment of setting process of concrete is important as it provides useful information to schedule concreting work in construction site. Electrical impedance measurement method, which utilizes the change of electrical resistance of concrete, has been applied to assess setting process of cement-based materials. However, the applicability of the method has been demonstrated only for cement paste and mortar. The main purpose of this research is to develop the electrical impedance based setting process assessment for concrete. To this end, electrical impedance response model for concrete should be developed in advance since it is essential to estimate the electrical resistance of concrete from measured impedance response. The electrical resistance of concrete is a key parameter for the setting process assessment. In this study electrical impedance responses of the concrete in setting process are measured and analyzed. Thereby, an electrical impedance response model of the liquid state concrete is developed and schematically validated.

Autonomous hardware development for impedance-based structural health monitoring

  • Grisso, Benjamin L.;Inman, Daniel J.
    • Smart Structures and Systems
    • /
    • v.4 no.3
    • /
    • pp.305-318
    • /
    • 2008
  • The development of a digital signal processor based prototype is described in relation to continuing efforts for realizing a fully self-contained active sensor system utilizing impedance-based structural health monitoring. The impedance method utilizes a piezoelectric material bonded to the structure under observation to act as both an actuator and sensor. By monitoring the electrical impedance of the piezoelectric material, insights into the health of the structured can be inferred. The active sensing system detailed in this paper interrogates a structure utilizing a self-sensing actuator and a low cost impedance method. Here, all the data processing, storage, and analysis is performed at the sensor location. A wireless transmitter is used to communicate the current status of the structure. With this new low cost, field deployable impedance analyzer, reliance on traditional expensive, bulky, and power consuming impedance analyzers is no longer necessary. A complete power analysis of the prototype is performed to determine the validity of power harvesting being utilized for self-containment of the hardware. Experimental validation of the prototype on a representative structure is also performed and compared to traditional methods of damage detection.

An Enhanced Power Sharing Strategy for Islanded Microgrids Considering Impedance Matching for Both Real and Reactive Power

  • Lin, Liaoyuan;Guo, Qian;Bai, Zhihong;Ma, Hao
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.282-293
    • /
    • 2017
  • There exists a strong coupling between real and reactive power owing to the complex impedances in droop based islanded microgrids (MGs). The existing virtual impedance methods consider improvements of the impedance matching for sharing of the voltage controlled power (VCP) (reactive power for Q-V droop, and real power for P-V droop), which yields a 1-DOF (degree of freedom) tunable virtual impedance. However, a weak impedance matching for sharing of the frequency controlled power (FCP) (real power for $P-{\omega}$ droop, and reactive power for $Q-{\omega}$ droop) may result in FCP overshoots and even oscillations during load transients. This in turn results in VCP oscillations due to the strong coupling. In this paper, a 2-DOF tunable adaptive virtual impedance method considering impedance matching for both real and reactive power (IM-PQ) is proposed to improve the power sharing performance of MGs. The dynamic response is promoted by suppressing the coupled power oscillations and power overshoots while realizing accurate power sharing. In addition, the proposed power sharing controller has a better parametric adaptability. The stability and dynamic performances are analyzed with a small-signal state-space model. Simulation and experimental results are presented to investigate the validity of the proposed scheme.

A Study on a Catenary Impedance Estimation Technique using Boosting Current Compensation Based on Current Division Characteristics of an AT Feeding System

  • Jung, Hosung;Kim, Hyungchul;Chang, Sang-Hoon;Kim, Joorak;Min, Myung-Hwan;An, Tae-Pung;Kwon, Sung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1370-1376
    • /
    • 2015
  • Generally, an autotransformer(AT) feeding system consists of double tracks, up and down, with the trolley wire and feeder wire of the up and down tracks connected in the sectioning post(SP). Consequently, load current or fault current flows on two tracks based on catenary impedance characteristics, making it difficult to estimate catenary impedance accurately. This paper presents a technique for the estimation of catenary impedance using boosting current compensation based on the current division characteristics of an AT feeding system to improve the operation performance of impedance relay. To verify the technique, we model an AT feeding system through a power analysis program (PSCAD/EMTDC) and simulate various operation and fault conditions. Through the simulation, we confirmed that the proposed technique has estimated catenary impedance with a similar degree of accuracy to the actual catenary impedance

Experimental investigation of magnetic-mount PZT-interface for impedance-based damage detection in steel girder connection

  • Ryu, Joo-Young;Huynh, Thanh-Canh;Kim, Jeong-Tae
    • Structural Monitoring and Maintenance
    • /
    • v.4 no.3
    • /
    • pp.237-253
    • /
    • 2017
  • Among various structural health monitoring technologies, impedance-based damage detection has been recognized as a promising tool for diagnosing critical members of civil structures. Since the piezoelectric transducers used in the impedance-based technique should be bonded to the surface of the structure using bonding layers (e.g., epoxy layer), it is hard to maintain the as-built condition of the bonding layers and to reconfigure the devices if needed. This study presents an experimental investigation by using magnetically attached PZT-interface for the impedance-based damage detection in bolted girder connections. Firstly, the principle of the impedance-based damage detection via the PZT-interface device is outlined. Secondly, a PZT-interface attachment method in which permanent magnets are used to replace the conventional bonding layers is proposed. Finally, the use of the magnetic attraction for the PZT-interface is experimentally evaluated via detecting the bolt-loosening events in a bolted girder connection. Also, the sensitivity of impedance signatures obtained from the PZT-interface is analyzed with regard to the interface's material.

Bioelectrical Impedance Analysis on the Paretic and Non-paretic Regions of Severe and Mild Hemiplegic Stroke Patients

  • Yoo, Chanuk;Yang, Yeongae;Baik, Sungwan;Kim, Jaehyung;Jeon, Gyerok
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.2
    • /
    • pp.115-125
    • /
    • 2017
  • For many stroke patients undergoing rehabilitation therapy, there is a need for indicator for evaluating the body function in paretic and non-paretic regions of stroke patients quantitatively. In this paper, the function of muscles and cells in paretic and non-paretic regions of severe and mild hemiplegic stroke patients was evaluated using multi-channel bioelectrical impedance spectroscopy. The paretic and non-paretic regions of severe and mild stroke patients were quantitatively assessed by using bioelectrical impedance parameters such as prediction marker (PM), phase angle (${\theta}$), characteristic frequency ($f_c$), and bioelectrical impedance vector analysis (BIVA). The mean values of impedance vector were significantly discriminated in all comparisons (severe-paretic, severe-non-paretic, mild-paretic, and mild-non-paretic). The bioelectrical impedance parameters were proved to be a very valuable tool for quantitatively evaluating the paretic and non-paretic regions of hemiplegic stroke patients.

Calculation of Radiation Impedance for Piston Sources on a Spherical Baffle (구형 배플상의 피스톤 음원에 대한 방사임피던스 계산)

  • 박순종;김무준;김천덕
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.54-60
    • /
    • 2003
  • The characteristics of radiation impedance for piston source on a spherical baffle are analyzed by algorithms which consists of Finite Element Method (FEM) and Hybrid type Infinite Element Method (HIEM). The results of self-radiation impedance for radiation angle and mutual radiation impedance between piston sources coincided with other reports on the spherical rigid baffle. For the spherical non-rigid baffles, the variations of self-radiation impedance and mutual-radiation impedance are identified. Therefore, these results can be applied to design and radiation characteristics analysis of acoustic transducers.

A Study of the Chinese Research Trend on Using Impedance Cardiography for Chinese Medicine (중국의 중의학적 심조항도(心阻抗圖)연구 동향)

  • Ko, Young-Il;Lee, Hyon-Soo;Park, Yong-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.1
    • /
    • pp.1-12
    • /
    • 2008
  • Object: The purpose of this study is to the review recent 20 years chinese achievements on the use of impedance cardiography for chinese medicine. Methods: From the China Journal Full Text Database we searched papers on the use of impedance cardiography for chinese medicine by the keyword "심조항도(心阻抗圖)". Results: The researches are summarized into 3 parts. (1) the researches on the relationship between the parameters of impedance cardiography and the chinese medical diagnoses; pulse diagnosis and tongue inspection. (2) the researches on the objective assessment using impedance cardiography for the effects of chinese medical therapy. (3) the researches on the objective evaluation index of Heart Deficiency Syndrome using impedance cardiography. Conclusion: The parameters of impedance cardiography has been established for its usefulness in various chinese medical researches.

  • PDF