• Title/Summary/Keyword: Impact load

Search Result 1,609, Processing Time 0.023 seconds

Nonlinear finite element analysis of ultra-high performance fiber reinforced concrete beams subjected to impact loads

  • Demirtas, Gamze;Caglar, Naci;Sumer, Yusuf
    • Structural Engineering and Mechanics
    • /
    • v.82 no.1
    • /
    • pp.81-92
    • /
    • 2022
  • Ultra-high performance fiber reinforced concrete (UHPFRC) is a composite building material with high ductility, fatigue resistance, fracture toughness, durability, and energy absorption capacity. The aim of this study is to develop a nonlinear finite element model that can simulate the response of the UHPFRC beam exposed to impact loads. A nonlinear finite element model was developed in ABAQUS to simulate the real response of UHPFRC beams. The numerical results showed that the model was highly successful to capture the experimental results of selected beams from the literature. A parametric study was carried out to investigate the effects of reinforcement ratio and impact velocity on the response of the UHPFRC beam in terms of midpoint displacement, impact load value, and residual load-carrying capacity. In the parametric study, the nonlinear analysis was performed in two steps for 12 different finite element models. In the first step, dynamic analysis was performed to monitor the response of the UHPFRC beam under impact loads. In the second step, static analysis was conducted to determine the residual load-carrying capacity of the beams. The parametric study has shown that the reinforcement ratio and the impact velocity affect maximum and residual displacement value substantially.

The Research of the Heavy-Weight Impact Sound Characteristic by Live load Installation on the Source Room (공동주택 음원실 바닥의 하중 설치에 따른 중량충격음 특성에 관한 연구)

  • Kim, Kyoung-Woo;Yang, Kwan-Seop;Sohn, Jang-Yeul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.6
    • /
    • pp.235-242
    • /
    • 2007
  • The test and evaluation of floor impact sound is mainly conducted before move in the residence. Floor impact sound generating is actually the conditions in which a heavy load like a curtain and furniture is installed, the situation before and after move in the residence is different. In this study, we investigate the floor impact sound variations according to the live load installation like furniture in the source room. The vibration acceleration level and floor impact sound level variation were measured before and after live load ($200kg/m^2$) installation in the floor impact sound test building and the field. The difference was not large although the vibration acceleration level and the floor impact sound level were reduced through measurement result of load installation. Resonance frequency was not changed by load installation.

Analysis for Evaluating the Impact of PEVs on New-Town Distribution System in Korea

  • Choi, Sang-Bong
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.859-864
    • /
    • 2015
  • This paper analyzes the impact of Plug-in Electric vehicles(PEVs) on power demand and voltage change when PEVs are connected to the domestic distribution system. Specifically, it assesses PEVs charging load by charging method in accordance with PEVs penetration scenarios, its percentage of total load, and voltage range under load conditions. Concretely, we develop EMTDC modelling to perform a voltage distribution analysis when the PEVs charging system by their charging scenario was connected to the distribution system under the load condition. Furthermore we present evaluation algorithm to determine whether it is possible to adjust it such that it is in the allowed range by applying ULTC when the voltage change rate by PEVs charging scenario exceed its allowed range. Also, detailed analysis of the impact of PEVs on power distribution system was carried out by calculating existing electric power load and additional PEVs charge load by each scenario on new-town in Korea to estimate total load increases, and also by interpreting the subsequent voltage range for system circuits and demonstrating conditions for countermeasures. It was concluded that total loads including PEVs charging load on new-town distribution system in Korea by PEVs penetration scenario increase significantly, and the voltage range when considering ULTC, is allowable in terms of voltage tolerance range up to a PEVs penetration of 20% by scenario. Finally, we propose the charging capacity of PEVs that can delay the reinforcement of power distribution system while satisfying the permitted voltage change rate conditions when PEVs charging load is connected to the power distribution system by their charging penetration scenario.

Experimental Study on Impact Loads Acting on Free-falling Modified Wigley

  • Hong, Sa-Young;Kim, Young-Shik;Kyoung, Jo-Hyun;Hong, Seok-Won;Kim, Yong-Hwan
    • International Journal of Ocean System Engineering
    • /
    • v.2 no.3
    • /
    • pp.151-159
    • /
    • 2012
  • The characteristics of an impact load and pressure were experimentally investigated. Drop tests were carried out using a modified Wigley with CB = 0.56. The vertical force, pressures, and vertical accelerations were measured. A 6-component load cell was used to measure the forces, piezo-electric sensors were used to capture the impact pressure, and strain-gauge type accelerometers were used to measure the vertical accelerations. A 50-kHz sampling rate was applied to capture the peak values. The repeatability of the measured data was confirmed and the basic characteristics of the impact load and pressure such as the linearity to the falling height were observed for all of the measurements. A simple formula was derived to extract the physical impact load from the measured force based on a simple mass-sensor-mass diagram, which was validated by comparing impact forces with existing data using the mathematical model of Faltinsen and Chezhian (2005). The effects of the elasticity of the model and change in acceleration during the water entry were investigated. It is interesting to observe that the impact loads occurred and reached peak values at the same time duration after water entry for all drop heights.

Community Characteristics and Assessment of Water Quality Impact by Plants at Flooded Area (저수지역 식물의 군집특성 및 수질영향 평가)

  • Lee, Yosang;Kim, Hojoon;Jeong, Seon A
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.6
    • /
    • pp.407-415
    • /
    • 2006
  • This study carried out submerged area due to Dam construction in the near future. It includes species classification of plant, survey of community structure, examination of pollutant load and assessment of water quality impact. The vascular plants of this area are listed 224 taxa; 64 families, 168 genera, 193 species, 30 varieties and 1 form. This study area is classified into total 21 communities, most community was consist of grass vegetation. Among the communities, Erigeron annuus ($869,286m^2$, 22%) community was dominant and Erigeron annuus-Avena fatua comminity (16%) was subdominant until May, and then Erigeron canadensis community occupied most area to $1,774,985m^2$ (32%) from May to July. For the evaluation of water quality impact due to submerged macrophyte, nutrient release test was conducted both dead body macrophyte and living body macrophyte. The results of release test show that T-N is not released at dead body macrophyte, but it is released at living body macrophyte, especially living body Artemisia priceps var. orientalis shows 1.436mgN/g. At release test of dead body macrophyte, T-P release rate of Erigeron annuus shows 0.500mgP/g at the top of them and it also shows 0.436mgP/g at Erigeron annuus of living body macrophyte. T-N load of submerged macrophyte shows 0.76% by comparison of total load on watershed and T-P load of that shows 3.61%. In case of removal macrophyte for reduction of pollutant load in submerged area, T-N load of submerged macrophyte changes from 0.76% to 0.15% by comparison of total load on watershed and T-P load of that changes from 3.61% to 0.72%.

Development of Structural Analysis System of Bow Flare Structure(2) - Prediction of Wave Impact Load Area - (선수 구조부 구조해석 시스템 개발(2) - 파랑충격하중 면적의 추정 -)

  • S.G. Lee;J.W. Park
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.36 no.4
    • /
    • pp.87-94
    • /
    • 1999
  • Empirical design is still used to avoid a structural damage because impact phenomenon and structural behaviour due to wave impact load can not examined accurately. The damage due to wave impact load is largely affected by impact pressure impulse and impact load area. The objective of this study is, as the second step, to develop an efficient scantling program of bow flare structure, and to predict its impact load area by comparing maximum dented deformations at center of idealized panel structure model of bow flare structure of 300k DWT VLCC using LS/DYNA3D code, which will be used for its verification of dynamic structural analysis, as the next step. Through this study, the impact load area was estimated as $1.5s{\times}1.5s$ stiffener space(s) in the case of panel with stiffeners and as $2.5s{\times}2.5s$, with stringers, under impact pressure curve with peak height 6.5MPa, tail height 1.0MPa, and duration time 5.0msec.

  • PDF

The effects of stacking sequence on the penetration-resistant behaviors of T800 carbon fiber composite plates under low-velocity impact loading

  • Ahmad, Furqan;Hong, Jung-Wuk;Choi, Heung Soap;Park, Soo-Jin;Park, Myung Kyun
    • Carbon letters
    • /
    • v.16 no.2
    • /
    • pp.107-115
    • /
    • 2015
  • Impact damages induced by a low-velocity impact load on carbon fiber reinforced polymer (CFRP) composite plates fabricated with various stacking sequences were studied experimentally. The impact responses of the CFRP composite plates were significantly affected by the laminate stacking sequences. Three types of specimens, specifically quasi-isotropic, unidirectional, and cross-ply, were tested by a constant impact carrying the same impact energy level. An impact load of 3.44 kg, corresponding to 23.62 J, was applied to the center of each plate supported at the boundaries. The unidirectional composite plate showed the worst impact resistance and broke completely into two parts; this was followed by the quasi-isotropic lay-up plate that was perforated by the impact. The cross-ply composite plate exhibited the best resistance to the low-velocity impact load; in this case, the impactor bounced back. Impact parameters such as the peak impact force and absorbed energy were evaluated and compared for the impact resistant characterization of the composites made by different stacking sequences.

Impact of Electric Vehicle Penetration-Based Charging Demand on Load Profile

  • Park, Woo-Jae;Song, Kyung-Bin;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.244-251
    • /
    • 2013
  • This paper presents a study the change of the load profile on the power system by the charging impact of electric vehicles (EVs) in 2020. The impact of charging EVs on the load demand is determined not only by the number of EVs in usage pattern, but also by the number of EVs being charged at once. The charging load is determined on an hourly basis using the number of the EVs based on different scenarios considering battery size, model, the use of vehicles, charging at home or work, and the method of charging, which is either fast or slow. Focusing on the impact of future load profile in Korea with EVs reaching up 10 and 20 percentage, increased power demand by EVs charging is analyzed. Also, this paper analyzes the impact of a time-of-use (TOU) tariff system on the charging of EVs in Korea. The results demonstrate how the penetration of EVs increases the load profile and decreases charging demand by TOU tariff system on the future power system.

On the Dynamic Response of a Beam with Variable Section subject to Impact Load (충격하중(衝擊荷重)을 받는 변단면(變斷面)보의 동적(動的) 응답해석(應答解析))

  • K.S.,Choi;C.D.,Jang
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.21 no.1
    • /
    • pp.13-20
    • /
    • 1984
  • As the first step to the dynamic stress analysis of structures, transient responses of a Timoshenko beam with variable section subject to impact load are analyzed. According to the various characteristics of impact load, time histories of the transient response of Timoshenko beam with general boundary conditions are obtained and compared with those of one degree of freedom system. Numerical solutions of the governing equations of motion are calculated by adopting the equivalent lumped-mass system and the finite difference method. It is found that the dynamic responses of Timshenko beam depend on the effect of concentration and location of impact load. As a result, increasing tendency of fluctuation in dynamic response, especially in bending moment, is found according to the increase of load concentration factor in time and space.

  • PDF

Dynamic Instability Analysis of Euler Column under Impact Loading (충격하중을 받는 Euler기둥의 동적좌굴 해석)

  • 김형열
    • Computational Structural Engineering
    • /
    • v.9 no.3
    • /
    • pp.187-197
    • /
    • 1996
  • An explicit direct time integration method based solution algorithm is presented to predict dynamic buckling response of Euler column. On the basis of large deflection beam theory, a plane frame finite element is formulated and implemented into the solution algorithm. The element formulation takes into account geometrical nonlinearity and overall buckling of steel structural frames. The solution algorithm employs the central difference method. Using the computer program developed by the author, dynamic instability behavior of Euler column under impact loading is investigated by considering the time variation of load, load magnitude, and load duration. The free vibration of Euler column caused by a short duration impact load is also studied. The validity and efficiency of the present formulation and solution algorithm are verified through illustrative numerical examples.

  • PDF