• 제목/요약/키워드: Immediate implants

검색결과 182건 처리시간 0.025초

가토에 이식된 Titanium plasma Sprayed IMZ 임프란트와 골의 계면 접촉 양상에 따른 결합력에 관한 연구 (A STUDY ON SHEAR BOND STRENGTH OF INTERFACE BETWEEN BONE AND TITANIUM PLASMA SPRAYED IMZ IMPLANT IN RABBITS)

  • 한종현;한동후
    • 대한치과보철학회지
    • /
    • 제29권2호
    • /
    • pp.225-243
    • /
    • 1991
  • In recent years immediate implantation has been tried by a few clinicians. This study placed IMZ implants in the rabbit femur with and without bony defects around the implant for simulating fresh extraction site. And one group with bony defects used porous hydroxyapatite ganules(HA) to fill if and the other group left the bony defects around the implant. The purpose of this study was to compare the shear bond strength and the bony contact and formation around the implant. Fifteen rabbits were divided into three groups and placed 10 IMZ implants to each group. Implant sites were surgically prepared with IMZ drills kit and implants were placed(Control), artificial bony defect was created with Apaceram drills kit around the implant sites and implants were placed(Experimental I), bony defect was filled with porous hydroxyapatite granules(Experimental II). Thereafter, rabbits were sacrificed at 8th week and specimens were prepared and pushout tested for shear bond strength of bone-implant interface immediately. Undecalcified and decalcified specimens were prepared with Vilanueva and hematoxylin-eosin stain for light microscopic finding. The results of this study were as follows. 1. In the control group, mean shear strength of bone-implant interface was $2.614{\pm}0.680$ MPa, experimental I was $0.664{\pm}0.322$ MPa, and experimental II was $2.281{\pm}0.606$ MPa. There was significant difference between control and experimental I, between experimental I and experimental II, but did not show significant difference between control and experimental II statistically. 2. In the bony formation surrounding IMZ implant of the three groups, that of cortical bone is more advanced than cancellous bone area. 3. In the histological findings of undecalcified specimens, control and experimental II showed more than 50% of bony or osteoid formation at the bony-implant interface. 4. In the histological findings of undecalcified specimens, experimental I showed less than 50% of bony or osteoid formation at the interface, and observed partial bony defect in the coronal zone. 5. In the experimental II group, were observed direct bony contact to hydroxyapatite granules, and infiltration of a few giant cells. 6. No inflammatory responses were seen around the titanium implants and the hydroxyapatite granules.

  • PDF

Micro-Implant Anchorage(MIA)를 이용한 Sliding mechancis (A new protocol of the sliding mechanics with Micro-Implant Anchorage(M.I.A.))

  • 박효상
    • 대한치과교정학회지
    • /
    • 제30권6호
    • /
    • pp.677-685
    • /
    • 2000
  • 고정원의 조절은 교정치료에 있어서 매우 중요한 요소로 이를 보강하기 위한 많은 노력이 있어 왔다. 골융합성 임프란트의 경우 확실한 고정원으로서 가능성이 인정되고 있고, 또 임상에서 시도되고 있다. 그러나 임프란트를 매식하기 위해서는 무치악이 존재해야 하거나 하악구치 후방부위에 식립해야 하는 등 장소의 제약이 있고, 값이 비싸며, 골융합을 위하여 기다리는 시간이 필요하다는 등의 단점으로 인하여 보편화되고 있지는 않다. 최근 몇몇 임상가에 의하여 수술용 titanium microscrew 나 miniscrew를 교정치료시의 고정원으로 사용하려는 시도가 있었는데, 이것은 골융합성 임프란트보다 수술이 간단하며, 가격이 저렴하고, 치조골 어느 부위든지 식립할 수 있다는 장점이 있다. 저자는 M.I.A.(Micro-Implant Anchorage)를 고정원으로 사용한 sliding mechanics를 통하여 골격성 II급 부정교합자를 치료하였다. 상악의 M.I.A.는 상악전치의 후방견인의 고정원으로 사용되었고 하악의 M.I.A.는 하악 제1대구치의 직립과 제2대구치의 압하이동의 고정원으로 사용되었다. 하악 구치가 직립됨에 따라 하악골의 전상방 회전이 일어나 SNB각의 증가로 이어지고 ANB각의 감소를 가져 왔다. M.I.A.는 치료 전기간동안 안정되게 유지되어 교정치료의 고정원으로서의 가능성을 확인시켜 주었다. M.I.A.를 고정원으로 사용한 sliding mechanics를 통하여 골격성 II급 부정교합자를 치료하는 새로운 접근법은 환자의 협조도에 의존하지 않고 치료할 수 있고, 비교적 빠른 시기에 많은 안모의 변화를 가져와 환자의 협조도를 끌어 낼 수 있다. 그리고 상악 6전치를 동시에 후방견인하므로 치료기간을 줄일 수 있으며 호선의 교환이 적어 chair time이 짧다. 이런 결과로 미루어 볼 때 MIA는 치아이동의 고정원으로 역할을 할 수 있을 것으로 생각되고, MIA를 고정원으로 이용한 sliding mechanics를 통한 교정치료는 골격성 II급 부정교합의 치료에 있어서 쉽고 효율적인 치료법으로 생각된다.

  • PDF

성견의 Implant 주위에 $GUIDOR^{(R)}$ BARRIER MEMBRANE 사용후 골신생에 관한 실험적 연구 (AN EXPERIMENTAL STUDY OF $GUIDOR^{(R)}$ BARRIER MEMBRANE ABOUT BONE PROMOTION AROUND DENTAL IMPLANTS PLACED INTO EXTRACTION SOCKET IN DOGS)

  • 양명철;진우정;신효근;김오환
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제18권1호
    • /
    • pp.135-143
    • /
    • 1996
  • 이 연구의 목적은 성견의 발치와에 식립된 implants에 새로운 골 형성을 유도할 목적으로 사용한 흡수성막의 골유도재생술을 평가하고자 하였다. 성견의 제 3소구치를 발거하고 cylindrial HA-coated implants를 식립하였다. 실험군에는 흡수성막인 $GUIDOR^{(R)}$ 를 덮어 보호를 하고, 대조군은 막으로 보호하지 않았다. 성견은 1, 2, 4개월에 차례로 희생하였으며, 치유과정 및 골형성 정도의 평가를 위해 임상적, 방사선학적, 그리고 조직학적 관찰을 통한 다음과 같은 결론을 얻었다. 1. 치유리간 동안에 실험군의 흡수성막의 안정성과 조직의 만족할 만한 치유능력을 볼 수 있었다. 2. 술후 4개월 정도에서 막이 완전한 흡수를 볼 수 있었다. 3. 미숙골이 정상적인 충판의 성숙골로 바뀌는데 약 4개월의 시간이 필요하였다. 4. 대조군에 비하여 실험군에서 더 많은 골형성을 관찰할 수 있었다. 5. 흡수성막이 implant 매식에 유용하게 이용될 수 있으리라 평가한다.

  • PDF

만성 치주염 환자에서 다수치 발거 후 디지털 임시 즉시 의치 제작 및 임플란트 지지 가철성 국소의치 수복 증례 (Digital interim immediate denture fabrication and implant-supported removable partial denture fabrication after multiple teeth extraction in patient with chronic periodontitis: a case report)

  • 박민재;방지원;방주혁;임선영;이용상;이근우;김성용
    • 대한치과보철학회지
    • /
    • 제62권2호
    • /
    • pp.104-112
    • /
    • 2024
  • 다수 치아를 발치하면 환자는 사회적, 심리적, 심미적인 문제를 마주하게 된다. 이때, 치아를 발치하기 전 임시 즉시 의치를 제작하는 것을 통해 이러한 문제를 최소화할 수 있다. 특히, 디지털 기술을 활용해 임시 즉시 의치를 제작한다면 기공과정이 단순해 지고 환자의 적은 내원 횟수로 임시 즉시 의치를 완성할 수 있다. 한편, 소수의 잔존치가 남은 환자에서 고정성 임플란트 보철수복이 어렵고, 가철성 국소의치의 지지 및 유지가 불량할 것으로 예상되는 경우에 임플란트 지지 가철성 국소의치(Implant-supported removable partial denture)가 대체 치료 옵션으로 주목되며, 임플란트 보철물을 이용해 추가적인 지지 및 유지가 가능하다. 본 증례에서는 다수치아 발거 후 소수 잔존치 상황에서 디지털 기술을 활용해 임시 즉시 의치를 제작하였다. 이후 임플란트를 식립하고 서베이드 크라운을 제작해 가철성 국소의치의 지지, 안정, 유지를 제공하여 임상적으로 만족스러운 결과를 얻었기에 이를 보고하고자 한다.

Fiber-reinforced composite resin bridges: an alternative method to treat root-fractured teeth

  • Heo, Gun;Lee, Eun-Hye;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee
    • Restorative Dentistry and Endodontics
    • /
    • 제45권1호
    • /
    • pp.8.1-8.9
    • /
    • 2020
  • The replacement of missing teeth, especially in the anterior region, is an essential part of dental practice. Fiber-reinforced composite resin bridges are a conservative alternative to conventional fixed dental prostheses or implants. It is a minimally invasive, reversible technique that can be completed in a single visit. The two cases presented herein exemplify the treatment of root-fractured anterior teeth with a natural pontic immediately after extraction.

임상가를 위한 특집 2 - Early loading의 난제 stability dip, 어떻게 극복할 것인가? (Stability dip, the obstacle of early loading protocol, how can it be figured out?)

  • 박창주
    • 대한치과의사협회지
    • /
    • 제51권4호
    • /
    • pp.198-203
    • /
    • 2013
  • Nowadays, it seems like that the concept of the early loading protocol has been intruded between the concept of the immediate loading supported by advanced clinicians and the concept of the conventional loading supported by the prudent clinicians. In particular, the stability dip, which is found to occur usually at 4~6 weeks after dental implant placement because the decrease of the primary mechanical stability is not compensated by the increase of the secondary biologic stability, is frequently pointed out as one of the major causes of early loading failure. In this article, based on our recent clinical investigation about the crestal bone preservation effect of the early loaded NanoTite$^{TM}$ Tapered Certain Prevail$^{(R)}$ (Biomet 3i, USA), the concept of the early loading is revisited. In addition, various methods to overcome the stability dip are reviewed as the oral and maxillofacial surgeon's view point.

Single-tooth implant restoration with alveolar bone augmentation in the maxillary anterior tooth region: a case report

  • Lee, Seon-Ki
    • International Journal of Oral Biology
    • /
    • 제46권4호
    • /
    • pp.200-207
    • /
    • 2021
  • In case of gingival recession and alveolar bone defects due to tooth loss for a long period of time in a single tooth in the maxillary anterior region, it is not easy to obtain aesthetic results with a single implant prosthesis. For aesthetic restoration, it is important to preserve hard and soft tissues through alveolar bone augmentation as well as restore harmony with adjacent teeth and soft tissues by placing the implant in an ideal location. In this case, an implant was placed using guided bone regeneration and a connective tissue graft simultaneously with immediate implantation after extraction from the maxillary anterior region where only residual root was left for a long period of time.

성견에서 즉시 임플란트 식립시 국내 임플란트에서의 골 유착반응에 관한 연구 (Study on Osseointegration of the Immediate Placement Using Korean Implant Systems in Beagle Dog)

  • 서정윤;이욱재;이종철;신미란;김윤상;피성희;신형식;유형근
    • Journal of Periodontal and Implant Science
    • /
    • 제37권2호
    • /
    • pp.223-236
    • /
    • 2007
  • This study was attempted to evaluate home-manufactured implants by placing $Stage-1^{(R)}$ Implant (Lifecore, Co., USA) whose surface is treated with REM that has already been varified clinically,$Chaorum^{(R)}$ Implant(Chaorum Co., Korea) whose surface treatment is same as that of Stage-1 Implant and $Atlas^{(R)}$ Implant(Cewellmedi Co., Korea) whose surface is treated with anodic oxidation immediately after the teeth of experimental animals were extracted to compare histological findings among them. Stage-l Implant(diameter: 3.5mm, length: IOmm), Chaorum Implant(diameter: 3.3mm, length: 8.5mm) and Cowell medi Implant(diameter: 4.0mm, length: 8.0mm) were placed into the mandible premolars of 2 adult beagle dogs immediately after their teeth were extracted, and then histological findings were analyzed at 6 weeks. After those implants were inserted directly after their teeth were extracted, the results of periotest were recorded, radiography was done, the subjects went through thorough control for 6 weeks, and then comparison among periotest, radiography and histological finding was made. After comparison of those findings, the values of periotest were satisfactory and bone healing was relatively satisfactory on radiography at 6 weeks. For osseointegration with the bone tissue, Stage-1 was 45.3%, Chaorum 55.3%, and Cowellmedi 52.5%, which was a satisfactory result. Although implant surgery immediately after teeth were extracted involves difficulties among recent implant surgeries, it is being frequently used in that it may reduce surgery hours, the frequency of surgery, and bone loss for patients. This experiment was conducted to evaluate the technological levels of home-manufactured implants that have been remarkably developed in recent years and in conclusion, those implants showed nearly similar result.

SLA surface를 가진 taper straight designed implant의 방사선학적 평가와 생존율: 1년 추적 관찰을 통한 후향적 연구 (Radiologic evaluation and survival rate of taper-straight designed implant with SLA surface: A 1-year follow-up retrospective study)

  • 김지은;김예슬;김옥수
    • 대한치과보철학회지
    • /
    • 제59권4호
    • /
    • pp.405-414
    • /
    • 2021
  • 목적: 이번 연구는 최근 시판되고 있는 국내산 taper straight 타입의 SLA surface를 가진 임플란트의 변연골 흡수도와 생존율을 평가하여 임상적 유용성을 알아보기 위해 시행하였다. 대상 및 방법: 전남대학교 치과병원 치주과에서 2016년 8월부터 2019년 12월까지 KISPLANT®가 식립된 성인남녀 83명의 125개의 임플란트 중 포함 기준을 충족시키는 19명의 40개의 임플란트를 1년 동안의 관찰 대상으로 하였다. 처음과 1년 후의 치근단 방사선 사진에서 변연골 수준을 측정하고, 이를 이용하여 임플란트 생존율과 성공률을 분석하였다. 또한 치주염 심도, SPT, 식립 부위, 치아 발거 이유, 즉시 식립 여부, 전신질환에 따라 변연골 흡수도에 유의한 차이가 있는지를 확인하기 위해 t-test를 수행하였다. 결과: 근심측 변연골 흡수도는 0.74 ± 1.07 mm, 원심측 변연골 흡수도는 0.53 ± 1.04 mm로 나타났다. 1년 동안 40개의 임플란트 중 3개의 임플란트에서 2 mm 이상의 변연골 흡수가 일어나 임플란트 성공률은 92.5%이고 생존율은 100%이었다. t-test를 수행한 결과 근심측 변연골 흡수도와 식립 부위에서 유의한 차이가 있었고 나머지 요인에서는 유의한 차이가 없었다. 결론: 이번 연구에서 변연골 흡수도와 성공률, 생존율을 평가해 본 결과 임플란트 식립 1년 후 높은 생존율과 성공률을 보였고 낮은 변연골 흡수도를 보여 taper straight 타입의 SLA surface를 가진 임플란트는 우수한 임상 결과를 보였다.

구강 내 디지털 인상채득을 통한 상악 전치부 임플란트 즉시 임시 보철 수복 증례 (Digital intraoral impression for immediate provisional restoration of maxillary single implant: A case report)

  • 장윤정;김홍준;송미경;문지은;이한라;박찬익
    • 대한치과보철학회지
    • /
    • 제53권3호
    • /
    • pp.234-243
    • /
    • 2015
  • 디지털 기술의 발달로 무치악 부위의 임플란트 수복 시 그 진단과 치료 과정 전반에 걸쳐 구강 내 3차원 정보를 데이터화하여 보철물을 제작하는 것이 가능해졌다. 전통적인 인상채득 방식을 이용하여 모델을 만들고 이것을 스캔하여 보철물을 제작하던 CAD/CAM 이용 방식에서 벗어나 디지털 인상 코핑(scanbody)을 사용함으로써 모델 없이 디지털 인상을 채득하고 임플란트 임시 보철물 및 해부학적 지대주를 제작하는 술식으로 변화하고 있다. 그러나 아직 이러한 술식은 활발히 이루어지고 있지 않으며 특히 심미성이 요구되어 연조직 외형의 인기가 중요한 상악 전치부 임플란트 즉시 부하에서의 사용은 그 사례가 많지 않다. 이에 따라 본 증례 보고에서는 3명의 상악 전치부 단일 임플란트 수복 환자에서 디지털 인상 코핑(scanbody)을 체결한 후 구강 내 스캐너인 CEREC Omnicam (Sirona, Bensheim, Germany) 또는 Trios (3shape, Copenhagen, Denmark)로 디지털 인상채득을 통해 임플란트 지대주 및 임시 보철물을 제작하였다. 그 결과 디지털 인상채득을 통한 편리성, 정확성 그리고 최종 보철물의 양호한 심미성을 얻어 보고하고자 한다.