A comparative study on the fit and screw joint stability of ready-made abutment and CAD-CAM custom-made abutment (기성 지대주와 맞춤형 CAD-CAM 지대주의 적합 및 나사 안정성 비교)

  • Kim, Jong-Wook;Heo, Yu-Ri;Kim, Hee-Jung;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.276-283
    • /
    • 2013
  • Purpose: The purpose of this study was to investigate the fit and screw joint stability between Ready-made abutment and CAD-CAM custom-made abutment. Materials and methods: Osstem implant system was used. Ready-made abutment (Transfer abutment, Osstem Implant Co. Ltd, Busan, Korea), CAD-CAM custom-made abutment (CustomFit abutment, Osstem Implant Co. Ltd, Busan, Korea) and domestically manufactured CAD-CAM custom-made abutment (Myplant, Raphabio Co., Seoul, Korea) were fabricated five each and screws were provided by each company. Fixture and abutments were tightening with 30Ncm according to the manufacturer's instruction and then preloding reverse torque values were measured 3 times repeatedly. Kruskal-Wallis test was used for statistical analysis of the preloading reverse torque values (${\alpha}=.05$). After specimens were embedded into epoxy resin, wet cutting and polishing was performed and FE-SEM imaging was performed, on the contact interface. Results: The pre-loading reverse torque values were $26.0{\pm}0.30Ncm$ (ready-made abutment; Transfer abutment) and $26.3{\pm}0.32Ncm$ (CAD-CAM custom-made abutment; CustomFit abutment) and $24.7{\pm}0.67Ncm$ (CAD-CAM custom-made abutment; Myplant). The domestically manufactured CAD-CAM custom-made abutment (Myplant abutment) presented lower pre-loading reverse torque value with statistically significant difference than that of the ready-made abutment (Transfer abutment) and CAD-CAM custom-made abutment (CustomFit abutment) manufactured from the same company (P=.027) and showed marginal gap in the fixture-abutment interface. Conclusion: Within the limitation of the present in-vitro study, in domestically manufactured CAD-CAM custom-made abutment (Myplant abutment) showed lower screw joint stability and fitness between fixture and abutment.

Comparison of the Legislation Applicable to Compare the use of Diagnostic Radiation Devices (진단용 방사선발생장치 이용에 적용되는 법제의 비교)

  • Ko, Jong-Kyung;Jeon, Yeo-Ryeong;Han, Eun-Ok;Cho, Pyong-Kon;Kim, Yong-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.277-286
    • /
    • 2015
  • Diagnostic radiation devices that is used in the country has reached to 78,000 units. When used for human subjects diagnostic purposes, it is subject to Medical Service Act, when used in diagnostic purposes in animal subjects, the subject to Veterinarians Act. When used for other purposes are subject to the Nuclear Safety Act. Even the same radiation devices varies the legislation that is applied depending on the intended use and object. Diversified been p rovisions a re necessary compared to t he analysis o f l egal content in o rder t o prevent confusion of the legislation is a matter to be applied. It is a qualitative study that Nuclear Safety Act, Medical Service Act and Veterinarians Act administrative procedures for the introduction of the applied diagnostic radiation devices, safety inspection, human resources management, area management and the content related to administrative punishment. The Nuclear Safety Act sub-provisions, the introduction of diagnostic radiation generating devices, there are many complex and complete requirements administrative procedures on the concept of a permit. Inspection of safety associated with the use, would be subject to periodic inspection auditing characteristics over the entire field of radiation safety management. It must receive court regular education for the safety administrator and workers. Unlike the reference of the radiation dose rate to specify the radiation controlled area there is a measurement obligation of radiation dose rate. Unlike the reference of the radiation dose rate to specify the radiation controlled area there is a measurement obligation of radiation dose rate. Quantitative difference of administrative punishment that is imposed when legislation violation has reached up to 10 times, over the entire field, the largest burden of radiation safety management at the time of application of the Nuclear Safety Act sub provisions. And it is applied differently depending on the purpose and the imaging target using the same diagnostic radiation devices. Depending on the use mainly under the current legal system, radiation can be lacking in fairness of the contents of the legislation for safety management, there is a risk of confusion. Alternatives such as centralized and standardization of legislation by diagnostic radiation devices use is expected to be necessary.

Sea Surface pCO2 and Its Variability in the Ulleung Basin, East Sea Constrained by a Neural Network Model (신경망 모델로 구성한 동해 울릉분지 표층 이산화탄소 분압과 변동성)

  • PARK, SOYEONA;LEE, TONGSUP;JO, YOUNG-HEON
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.21 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • Currently available surface seawater partial pressure carbon dioxide ($pCO_2$) data sets in the East Sea are not enough to quantify statistically the carbon dioxide flux through the air-sea interface. To complement the scarcity of the $pCO_2$ measurements, we construct a neural network (NN) model based on satellite data to map $pCO_2$ for the areas, which were not observed. The NN model is constructed for the Ulleung Basin, where $pCO_2$ data are best available, to map and estimate the variability of $pCO_2$ based on in situ $pCO_2$ for the years from 2003 to 2012, and the sea surface temperature (SST) and chlorophyll data from the MODIS (Moderate-resolution Imaging Spectroradiometer) sensor of the Aqua satellite along with geographic information. The NN model was trained to achieve higher than 95% of a correlation between in situ and predicted $pCO_2$ values. The RMSE (root mean square error) of the NN model output was $19.2{\mu}atm$ and much less than the variability of in situ $pCO_2$. The variability of $pCO_2$ with respect to SST and chlorophyll shows a strong negative correlation with SST than chlorophyll. As SST decreases the variability of $pCO_2$ increases. When SST is lower than $15^{\circ}C$, $pCO_2$ variability is clearly affected by both SST and chlorophyll. In contrast when SST is higher than $15^{\circ}C$, the variability of $pCO_2$ is less sensitive to changes in SST and chlorophyll. The mean rate of the annual $pCO_2$ increase estimated by the NN model output in the Ulleung Basin is $0.8{\mu}atm\;yr^{-1}$ from 2003 to 2014. As NN model can successfully map $pCO_2$ data for the whole study area with a higher resolution and less RMSE compared to the previous studies, the NN model can be a potentially useful tool for the understanding of the carbon cycle in the East Sea, where accessibility is limited by the international affairs.

Evaluation of Effective and Organ Dose Using PCXMC Program in DUKE Phantom and Added Filter for Computed Radiography System (CR 환경에서의 흉부촬영 시 Duke Phantom과 부가여과를 이용한 유효선량 및 장기선량 평가)

  • Kang, Byung-Sam;Park, Min-Joo;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.7-14
    • /
    • 2014
  • By using a Chest Phantom(DUKE Phantom) focusing on dose reduction of diagnostic radiation field with the most use of artificial radiation, and attempt to reduce radiation dose studies technical radiation. Publisher of the main user of the X-ray Radiological technologists, Examine the effect of reducing the radiation dose to apply additional filtering of the X-ray generator. In order to understand the organ dose and effective dose by using the PC-Based Monte Carlo Program(PCXMC) Program, the patient receives, was carried out this research. In this experiment, by applying a complex filter using a copper and Al(aluminum,13) and filtered single of using only aluminum with the condition set, and measures the number of the disk of copper indicated by DUKE Phantom. The combination of the composite filtration and filtration of a single number of the disk of the copper is the same, with the PCXMC 2.0. Program looking combination of additional filtration fewest absorbed dose was calculated effective dose and organ dose. Although depends on the use mAs, The 80 kVp AP projection conditions, it is possible to reduce the effective amount of about 84 % from about 30 % to a maximum at least. The 120 kVp PA projection conditions, it is possible to reduce the effective amount of about 71 % from about 41 % to a maximum of at least. The organ dose, dose reduction rate was different in each organ, but it showed a decrease of dose rate of 30 % to up 100 % at least. Additional filtration was used on the imaging conditions throughout the study. There was no change in terms of video quality at low doses. It was found that using the DUKE Phantom and PCXMC 2.0 Program were suitable to calculate the effect of reducing the effective dose and organ dose.

Monitoring soybean growth using L, C, and X-bands automatic radar scatterometer measurement system (L, C, X-밴드 레이더 산란계 자동측정시스템을 이용한 콩 생육 모니터링)

  • Kim, Yi-Hyun;Hong, Suk-Young;Lee, Hoon-Yol;Lee, Jae-Eun
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.2
    • /
    • pp.191-201
    • /
    • 2011
  • Soybean has widely grown for its edible bean which has numerous uses. Microwave remote sensing has a great potential over the conventional remote sensing with the visible and infrared spectra due to its all-weather day-and-night imaging capabilities. In this investigation, a ground-based polarimetric scatterometer operating at multiple frequencies was used to continuously monitor the crop conditions of a soybean field. Polarimetric backscatter data at L, C, and X-bands were acquired every 10 minutes on the microwave observations at various soybean stages. The polarimetric scatterometer consists of a vector network analyzer, a microwave switch, radio frequency cables, power unit and a personal computer. The polarimetric scatterometer components were installed inside an air-conditioned shelter to maintain constant temperature and humidity during the data acquisition period. The backscattering coefficients were calculated from the measured data at incidence angle $40^{\circ}$ and full polarization (HH, VV, HV, VH) by applying the radar equation. The soybean growth data such as leaf area index (LAI), plant height, fresh and dry weight, vegetation water content and pod weight were measured periodically throughout the growth season. We measured the temporal variations of backscattering coefficients of the soybean crop at L, C, and X-bands during a soybean growth period. In the three bands, VV-polarized backscattering coefficients were higher than HH-polarized backscattering coefficients until mid-June, and thereafter HH-polarized backscattering coefficients were higher than VV-, HV-polarized back scattering coefficients. However, the cross-over stage (HH > VV) was different for each frequency: DOY 200 for L-band and DOY 210 for both C and X-bands. The temporal trend of the backscattering coefficients for all bands agreed with the soybean growth data such as LAI, dry weight and plant height; i.e., increased until about DOY 271 and decreased afterward. We plotted the relationship between the backscattering coefficients with three bands and soybean growth parameters. The growth parameters were highly correlated with HH-polarization at L-band (over r=0.92).

Correlation of Clinical Outcome and Cuff Integrity after Open Repair in Large and Massive Rotator Cuff Tears (대형 및 광범위 회전근 개 파열의 개방적 봉합술 후 임상적 결과와 회전근 개 연속성(integrity)의 상관 관계)

  • Noh, Haeng-Kee;Wang, Joon-Ho;Kim, Dong-Hwee;Park, Jong-Woong;Kim, Jae-Gyoon;Park, Jung-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2007
  • Purpose: To evaluate the relationship between the clinical outcome and the cuff integrity following open repair in large and massive rotator cuff tears using ultrasonography as an imaging modality. Material and Methods: From November 2001 to April 2005, 17 cases(16 patients) who had open repair of tear measuring more than 3cm were assessed with minimal follow-up of 12 months in this study. 6 cases had a large tear and 11 cases a massive tear. There were 6 men and 11 women with a mean age of 52 years at surgery (range, 33 to 72 years). The evaluation consisted of the preoperative and postoperative shoulder scores according to UCLA shoulder scoring system and Visual analogue scale (VAS). Ultrasonography was performed by a experienced musculoskeletal physician at a minimum of 12 months postoperatively to evaluate the postoperative cuff integrity. Results: Retear were detected in four of seventeen cases. Regardless of the presence of recurrent tear, 14 cases had UCLA score of more than 29 points (good grade). All 17 had an improvement in the functional score, which increased from an average of 15.1 to 31.2 points. All cases showed pain relief and five cases had no pain. Sixteen cases except one had the range of motion of forward elevation above $90^{\circ}$. Conclusion: Open rotator cuff repair in large and massive tears showed low retear rate. At a minimum of twelve months follow-up, all cases had improvement on UCLA score, pain relief, increased range of motion of the shoulder regardless of retear. And the correlation between recurrent tear and function score was not statistically significant.

Decreased White Matter Structural Connectivity in Psychotropic Drug-Naïve Adolescent Patients with First Onset Major Depressive Disorder (정신과적 투약력이 없는 초발 주요 우울장애 청소년 환아들에서의 백질 구조적 연결성 감소)

  • Suh, Eunsoo;Kim, Jihyun;Suh, Sangil;Park, Soyoung;Lee, Jeonho;Lee, Jongha;Kim, In-Seong;Lee, Moon-Soo
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.25 no.2
    • /
    • pp.153-165
    • /
    • 2017
  • Objectives : Recent neuroimaging studies focus on dysfunctions in connectivity between cognitive circuits and emotional circuits: anterior cingulate cortex that connects dorsolateral orbitofrontal cortex and prefrontal cortex to limbic system. Previous studies on pediatric depression using DTI have reported decreased neural connectivity in several brain regions, including the amygdala, anterior cingulate cortex, superior longitudinal fasciculus. We compared the neural connectivity of psychotropic drug naïve adolescent patients with a first onset of major depressive episode with healthy controls using DTI. Methods : Adolescent psychotropic drug naïve patients(n=26, 10 men, 16 women; age range, 13-18 years) who visited the Korea University Guro Hospital and were diagnosed with first onset major depressive disorder were registered. Healthy controls(n=27, 5 males, 22 females; age range, 12-17 years) were recruited. Psychiatric interviews, complete psychometrics including IQ and HAM-D, MRI including diffusion weighted image acquisition were conducted prior to antidepressant administration to the patients. Fractional anisotropy(FA), radial, mean, and axial diffusivity were estimated using DTI. FMRIB Software Library-Tract Based Spatial Statistics was used for statistical analysis. Results : We did not observe any significant difference in whole brain analysis. However, ROI analysis on right superior longitudinal fasciculus resulted in 3 clusters with significant decrease of FA in patients group. Conclusions : The patients with adolescent major depressive disorder showed statistically significant FA decrease in the DTI-based structure compared with healthy control. Therefore we suppose DTI can be used as a bio-marker in psychotropic drug-naïve adolescent patients with first onset major depressive disorder.

Evaluate the implementation of Volumetric Modulated Arc Therapy QA in the radiation therapy treatment according to Various factors by using the Portal Dosimetry (용적변조회전 방사선치료에서 Portal Dosimetry를 이용한 선량평가의 재현성 분석)

  • Kim, Se Hyeon;Bae, Sun Myung;Seo, Dong Rin;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.167-174
    • /
    • 2015
  • Purpose : The pre-treatment QA using Portal dosimetry for Volumetric Arc Therapy To analyze whether maintaining the reproducibility depending on various factors. Materials and Methods : Test was used for TrueBeam STx$^{TM}$ (Ver.1.5, Varian, USA). Varian Eclipse Treatment planning system(TPS) was used for planning with total of seven patients include head and neck cancer, lung cancer, prostate cancer, and cervical cancer was established for a Portal dosimetry QA plan. In order to measure these plans, Portal Dosimetry application (Ver.10) (Varian) and Portal Vision aS1000 Imager was used. Each Points of QA was determined by dividing, before and after morning treatment, and the after afternoon treatment ended (after 4 hours). Calibration of EPID(Dark field correction, Flood field correction, Dose normalization) was implemented before Every QA measure points. MLC initialize was implemented after each QA points and QA was retried. Also before QA measurements, Beam Ouput at the each of QA points was measured using the Water Phantom and Ionization chamber(IBA dosimetry, Germany). Results : The mean values of the Gamma pass rate(GPR, 3%, 3mm) for every patients between morning, afternoon and evening was 97.3%, 96.1%, 95.4% and the patient's showing maximum difference was 95.7%, 94.2% 93.7%. The mean value of GPR before and after EPID calibration were 95.94%, 96.01%. The mean value of Beam Output were 100.45%, 100.46%, 100.59% at each QA points. The mean value of GPR before and after MLC initialization were 95.83%, 96.40%. Conclusion : Maintain the reproducibility of the Portal Dosimetry as a VMAT QA tool required management of the various factors that can affect the dosimetry.

  • PDF

Use of Numerical Simulation for Water Area Observation by Microwave Radar (마이크로웨이브 레이더를 이용한 수역관측에 있어서의 수치 시뮬레이션 이용)

  • Yoshida, Takero;Rheem, Chang-Kyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.3
    • /
    • pp.208-218
    • /
    • 2012
  • Numerical simulation technique has been developed to calculate microwave backscattering from water surface. The simulation plays a role of a substitute for experiments. Validation of the simulation was shown by comparing with experimental results. Water area observations by microwave radar have been simulated to evaluate algorithms and systems. Furthermore, the simulation can be used to understand microwave scattering mechanism on the water surface. The simulation has applied to the various methods for water area observations, and the utilizations of the simulation are introduced in this paper. In the case of fixed radar, we show following examples, 1. Radar image with a pulse Doppler radar, 2. Effect of microwave irradiation width and 3. River observation (Water level observation). In addition, another application (4.Synthetic aperture radar image) is also described. The details of the applications are as follows. 1. Radar image with a pulse Doppler radar: A new system for the sea surface observation is suggested by the simulation. A pulse Doppler radar is assumed to obtain radar images that display amplitude and frequency modulation of backscattered microwaves. The simulation results show that the radar images of the frequency modulation is useful to measure sea surface waves. 2. Effect of microwave irradiation width: It is reported (Rheem[2008]) that microwave irradiation width on the sea surface affects Doppler spectra measured by a CW (Continuous wave) Doppler radar. Therefore the relation between the microwave irradiation width and the Doppler spectra is evaluated numerically. We have shown the suitable condition for wave height estimation by a Doppler radar. 3. River observation (Water level observation): We have also evaluated algorithms to estimate water current and water level of river. The same algorithms to estimate sea surface current and sea surface level are applied to the river observation. The simulation is conducted to confirm the accuracy of the river observation by using a pulse Doppler radar. 4. Synthetic aperture radar (SAR) image: SAR images are helpful to observe the global sea surface. However, imaging mechanisms are complicated and validation of analytical algorithms by SAR images is quite difficult. In order to deal with the problems, SAR images in oceanic scenes are simulated.

Retrospective Evaluation of Discrepancies between Radiological and Pathological Size of Hepatocellular Carcinoma Masses

  • Tian, Fei;Wu, Jian-Xiong;Rong, Wei-Qi;Wang, Li-Ming;Wu, Fan;Yu, Wei-Bo;An, Song-Lin;Liu, Fa-Qiang;Feng, Li;Liu, Yun-He
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.21
    • /
    • pp.9487-9494
    • /
    • 2014
  • Background: The size of a hepatic neoplasm is critical for staging, prognosis and selection of appropriate treatment. Our study aimed to compare the radiological size of solid hepatocellular carcinoma (HCC) masses on magnetic resonance imaging (MRI) with the pathological size in a Chinese population, and to elucidate discrepancies. Materials and Methods: A total of 178 consecutive patients diagnosed with HCC who underwent curative hepatic resection after enhanced MRI between July 2010 and October 2013 were retrospectively identified and analyzed. Pathological data of the whole removed tumors wereassessed and differences between radiological and pathological tumor size were identified. All patients were restaged using a modified Tumor-Node-Metastasis (TNM) staging system postoperatively according to the maximum diameter alteration. The lesions were classified as hypo-staged, iso-staged or hyper-staged for qualitative assessment. In the quantitative analysis, the relative pre and postoperative tumor size contrast ratio ($%{\Delta}size$) was also computed according to size intervals. In addition, the relationship between radiological and pathological tumor diameter variation and histologic grade was analyzed. Results: Pathological examination showed 85 (47.8%) patients were overestimated, 82 (46.1%) patients underestimated, while accurate measurement by MRI was found in 11 (6.2%) patients. Among the total subjects, 14 (7.9%) patients were hypo-staged and 15 (8.4%) were hyper-staged post-operatively. Accuracy of MRI for calculation and characterized staging was related to the lesion size, ranging from 83.1% to 87.4% (<2cm to ${\geq}5cm$, p=0.328) and from 62.5% to 89.1% (cT1 to cT4, p=0.006), respectively. Overall, MRI misjudged pathological size by 6.0 mm (p=0.588 ), and the greatest difference was observed in tumors <2cm (3.6 mm, $%{\Delta}size=16.9%$, p=0.028). No statistically significant difference was observed for moderately differentiated HCC (5.5mm, p=0.781). However, for well differentiated and poorly differentiated cases, radiographic tumor maximum diameter was significantly larger than the pathological maximum diameter by 3.15 mm and underestimated by 4.51 mm, respectively (p=0.034 and 0.020). Conclusions: A preoperative HCC tumor size measurement using MRI can provide relatively acceptable accuracy but may give rise to discrepancy in tumors in a certain size range or histologic grade. In pathological well differentiated subjects, the pathological tumor size was significantly overestimated, but underestimated in poorly differentiated HCC. The difference between radiological and pathological tumor size was greatest for tumors <2 cm. For some HCC patients, the size difference may have implications for the decision of resection, transplantation, ablation, or arterially directed therapy, and should be considered in staging or selecting the appropriate treatment tactics.