Purpose: The aim of the study was to evaluate the hemodynamic changes after successful bypass surgery in patients with atherosclerotic stenosis in ICA using $^{99m}Tc-ECD$ SPECT. Materials and Methods: Fourteen patients (M:F=8:6, mean age; $60{\pm}9$ years) who underwent STA-MCA anastomosis for unilateral atherosclerotic cerebrovascular disease were enrolled. $^{99m}Tc-ECD$ basal/acetazolamide perfusion SPECT studies were performed before, 10 days and 6 months after bypass surgery. Perfusion reserve was defined as the % changes after acetazolamide over rest image. Regional cerebral blood flow and perfusion reserve were compared preoperative, early-postoperative and late-postoperative scans. Results: The mean resting perfusion and decrease in perfusion reserve in affected ICA territory on preoperative scan was $52.4{\pm}3.5\;and\;-7.9{\pm}4.7%$, respectively. The resting perfusion was significantly improved after surgery on early-postoperative scan (mean $53.7{\pm}2.7$) and late-postoperative scan (mean $53.3{\pm}2.5$) compared with preoperative images (p<0.05, respectively). Resting perfusion did not showed further improvement on late-postoperative scan compared with early-postoperative scan. The perfusion reserve was $-3.7{\pm}2.6%$ on early-postoperative scan, and $-1.6{\pm}2.3%$ on late-postoperative scan, which was significantly improved after surgery. Additionally, further improvement of perfusion reserved as observed on late-postoperative scan (p<0.05). While, in the unaffected ICA territory, no significant changes in the resting perfusion and perfusion reserve was observed. Conclusion: The improvement of resting perfusion and perfusion reserve in early-postoperative scan reflects the immediate restoration of the cerebral blood flow by bypass surgery. In contrasts, further improvement of perfusion reserve showing on late-postoperative scan may indicate a good collateral development after surgery, which may indicate good surgical outcome after surgery.
Kim Jeong-Seok;Kim Bum-Soo;Jeun Sin-Soo;Jung So-Lyung;Choe Bo-Young
Investigative Magnetic Resonance Imaging
/
v.9
no.1
/
pp.43-49
/
2005
A few studies have shown that the function of fusiform face area is selectively involved in the perception of faces including a race difference. We investigated the neural substrates of the face-selective region called fusiform face area in the ventral occipital-temporal cortex and same-race memory superiority in the fusiform face area by the event-related fMRI. In our fMRI study, subjects (Oriental-Korean) performed the implicit distinction of the race while they consciously made familiar-judgments, regardless of whether they considered a face as Oriental-Korean or European-American. For race distinction as an implicit task, the fusiform face areas (FFA) and the right parahippocampal gyrus had a greater response to the presentation of Oriental-Korean faces than for the European-American faces, but in the conscious race distinction between Oriental-Korean and European-American faces, there was no significant difference observed in the FFA. These results suggest that different activation in the fusiform regions and right parahippocampal gyrus resulting from superiority of same-race memory could have implicitly taken place by the physiological processes of face recognition.
Purpose: To evaluate the availability of magnetic resonance (MRI voiding cystography for the diagnosis of vesicoureteral reflux (VUR) and to compare the sensitivity of MR voiding cystography (MRVC) with that of radiographic voiding cystourethrography (VCUG) in the detection of VUR. Material and Methods : MRVC was performed upon 20 children referred for investigation of VUR. Either coronal T1-weighted spin-echo or spoiled gradient-echo images were obtained before and after transurethral administration of a mixture of normal saline and gadopentetate dimeglumine, and immediately after voiding. The findings of MRVC were compared with those of VCUG performed within 6 months of MRVC. Results 1 VUR was detected in 23 ureterorenal units f16 VUR's by both methods, five VUR's by VCUG, and two VUR's by MRVC). The sensitivity of VCUG and MRVC in detecting VUR was 91.3% (21/23) and 78.3% (18/23), respectively. MRVC detected renal scarring in 15 out of 17 kidneys with scintigraphically detected renal scarring. Conclusion : Although MRVC is slightly less sensitive than VCUG in the detection of VUR, it can be used for the diagnosis of VUR and renal scarring simultaneouslyl and thus will reduce the radiation hazard.
Purpose : This study was done to analyze the changes in the clinical conditions and the diagnosis of hypertrophic pyloric stenosis. Methods : We report a retrospective clinical analysis of 39 patients with hypertrophic pyloric stenosis from Jan. 1992 to Aug. 2001. The age and sex distribution, family and birth history, clinical symptoms, the ultrasonographic and the operative sizes of pyloric canals were compared. Results : The body weight was below the 3 percentile at admission in eight cases(20.5%). "Olive like mass" in right upper quadrant was palpated during physical examination in 23 cases(59%) and gastric peristaltic wave observed in six cases(15%). The ultrasonographic measurements showed that the pyloric muscle thickness to be $4.95{\pm}0.99mm$($mean{\pm}SD$), pyloric diameter $14.42{\pm}2.64mm$, and pyloric length $20.17{\pm}3.92mm$. Fredet-Ramstedt pyloromyotomy was employed in all cases. The operative measurements of the pyloric muscle thickness was $5.11{\pm}1.01mm$, pyloric diameter $15.01{\pm}2.47mm$, and pyloric length $22.32{\pm}3.43mm$. Conclusion : There was no significant difference between the ultrasonographic and operative measurements. Currently, the hypertrophic pyloric stenosis patients showed lesser clinical hallmarks of the disease. The earlier diagnosis using imaging studies before development of significant metabolic abnormalities is becoming an important factor that change the future outcomes of hypertrophic pyloric stenosis.
Lee Ji-Suk;Rho Kwang-Sik;Kim Ji-Hong;Lee Jae-Seung;Kim Pyung-Kil
Childhood Kidney Diseases
/
v.1
no.2
/
pp.144-150
/
1997
Purpose : The kidney is one of the most common sites of cyst formation. Cystic diseases of the kidney are a diverse group of clinicopathologic entities and variable prognosis. They span a wide range of both age of presentation and severity of the renal disease. And many of them are systemic disorders, sharing similar process of cyst formation in other organs. Recently, development of imaging studies has been contributing widely to the diagnosis of the diseases. Treatment, however, is not established satisfactorily. We performed this study to evaluate the occurrence and treatment of cystic diseases of the kidney. Methods : We reviewed retrospectively the medical records of 44 patients with cystic diseases of the kidney in the Department of Pediatrics, during last 11 years. Results : In the 44 patients with cystic diseases of the kidney, 31 patients(71%) had multicystic dysplastic kidney and 11(35%) of them received nephrectomy due to differentiation from neoplasms or severe abdominal distension. Seven patients(16%) had polycystic kidney disease, and all of them were infantile type. Five patients(11%) were diagnosed as having a simple renal cysts. Progression to renal failure was noted in none of the cases. In 14(32%) out of total 44 patients, the diagnosis was made in neonatal or infantile pelted. Conclusion : The incidence of cystic diseases of the kidney appeared very low, but further investigation on their pathogenesis, classification, and indication of treatment is needed.
Purpose: N-13 ammonia uptake and retention in the myocardium is related to perfusion and metabolism. There are several potential advantages of N-13 ammonia positron emission tomography (PET) to detect myocardial ischemia, such as higher spatial resolution, greater counting efficiencies, and robust attenuation correction. But there are few reports comparing Tc-99m myocardial perfusion single photon emission tomography (MPS) and N-13 ammonia PET. We thus compared adenosine stress N-13 ammonia PET/CT and Tc-99m sestamibi MPS in patients with suspected coronary artery stenosis. Materials and Methods: Seventeen patients (male 13 : $63{\pm}11$ years old) underwent adenosine stress N-13 ammonia PET/CT (Discovery ST, GE), Tc-99m sestamibi MPS (dual head gamma camera, Hawkeye, GE) and coronary angiography within 1 week. N-13 ammonia PET/CT and Tc-99m sestamibi MPS images were assessed with a 20-segment model by visual interpretation and quantitative analysis using automatic quantitative software (Myovation, GE). Results: Both sensitivities and specificities of detecting an individual coronary artery stenosis were higher for N-13 ammonia PET/CT than Tc-99m sestamibi MPS (PET/CT: 91%/89% vs MPS: 65%/82%). N-13 ammonia PET/CT showed reversibility in 52% of segments that were considered non-reversibile by Tc-99m sestamibi MPS. In the 110 myocardial segments supplied by the stenotic coronary artery, N-13 ammonia PET/CT showed higher count densities than Tc-99m MPS on rest study (p < 0.01), and the difference of count density between the stress and the rest studies was also larger on N-13 ammonia PET/CT. Conclusion: Adenosine stress N-13 ammonia PET/CT had higher diagnostic sensitivity and specificity, more reversibility of perfusion defects and greater stress/rest uptake differences than Tc-99m sestamibi MPS. Accordingly, N-13 ammonia PET/CT might offer better assessment of myocardial ischemia and viability.
Purpose: Normal pancreas has low uptake rate in $^{18}F$-FDG PET scan. However, it is possible to diagnose malignancy of pancreatic cancer which has high uptake rate. Many studies approve a high prevalence of diabetes in pancreatic cancer and if the blood glucose level (BGL) is over the normal range, FDG uptake will be decreased and there will be inconvenience for patients from the delay time to reduce the high BGL or could cause difficulty to arrange the schedule. Therefore, we studied the relation of BGL and image quality in pancreatic cancer on PET. Materials and Methods: A hundred patients had PET scan. The prevalence of pancreatic cancer and diabetes were evaluated using SPSS ver. 17. The fasting BGL of patients were examined and sorted as diabetes mellitus (DM) group and Non-DM group. For the evaluation, patients were divided into 3 groups (Non-DM, DM; BGL${\geq}7.0mmol/L$, and DM; BGL<7.0 mmol/L). The ROI was drown on Liver and Lung for the PET imaging analysis. Results: Fifty three male and forty seven female were in the patients. The average age was $60.1{\pm}13.5$. There were 36 patients (male: 22, female: 14, 36%) who had pancreatic cancer with DM. There were 15 patients who showed over 7.0 mmol/L in their fasting BGL and 85 patients who showed under 7.0 mmol/L in their fasting BGL. Among the Non-DM, DM; BGL${\geq}7.0mmol/L$, and DM; BGL<7.0 mmol/L, there was not a statistical significance (p>0.05). Conclusion: The prevalence of pancreatic cancer was comparatively high in this study. If the fasting BGL was slightly over the normal BGL, we believe it will not give a severe disturbance when the patients have PET scan. Furthermore, the examination schedule doesn't need to change and the inconvenience from the delay of patients preparation will be reduced.
Yi, Dae-Yong;Kim, Na-Yeon;Cho, Hee-Yeon;Kim, Ji-Eun;Sim, So-Yeon;Son, Dong-Woo;Jeon, In-Sang;Cha, Han
Childhood Kidney Diseases
/
v.12
no.2
/
pp.178-185
/
2008
Purpose : Our aim was to investigate the predictive factors for detecting grade III-V vesicoureteral reflux(VUR) in young infants less than 3 months with urinary tract infections (UTI). Methods : Data of infants who underwent ultrasonography and VCUG between January 2004 and September 2007 were reviewed. Age, gender, incidence of bacteremia, C-reactive protein(CRP) and imaging studies were compared between group I(grade III-V VUR) and group II (normal or grade I and II VUR) retrospectively. Sensitivity, specificity, positive and negative predictive values, odds ratio, and likelihood ratio of ultrasonography for high grade VUR were evaluated. Results : Among 54 enrolled infants(41 males, 13 females), 14 infants were group I and 40 infants were group II. In the group I, CRP level was significantly higher(6.11$\pm$5.18 vs. 3.27$\pm$3.45, P=0.025), and there were more ultrasonographic abnormal findings(71.4%, vs. 22.5%, P=0.002) compared with group II. However, ultrasonography was the only significant factor after adjusting with logistic regression(P=0.002). Incidence of bacteremia and abnormal DMSA findings were not significantly different in two groups. Sensitivity, specificity, and odds ratio of ultrasonography was 71.4%, 77.5%, 6.9 respectively. Negative predictive value was 88.6% and negative likelihood ratio was 0.37. Ultrasonography had significant negative likelihood ratio for grade III-V VUR, but missed 4 infants with grade III VUR. Conclusion : We could not find any alternative predictive factors to reduce VCUG in detecting high grade VUR. Therefore, VCUG must be considered in young infants less than 3 months with UTI.
Purpose: Although radionuclide cisternography (RNC) is an useful study to detect cerebrospinal fluid (CSF) leakage in the patient with spontaneous intracranial hypotension (SIH), it sometimes fails to demonstrate the site of CSF leakage. The aim of the study is to improve the detection of leakage site of CSF and to reduce time for the study in RNC using modified protocol (m-RNC). Materials & methods : The study consists of 8 studies of 7 patients ($38{\pm}8$ years, M:F=2:5) with SIH, who underwent m-RNC following administration of 185-222 MBq of $^{99m}Tc$-DTPA into the lumbar subarachnoid space. Sequential images were obtained the whole spine with the head including urinary bladder at 10 minute, 30 minute, 1 hour, 2 hour, 4 hour and 6 hour. Radioactivity of extradural space and urinary bladder was evaluated. Results: Leakage site of CSF was identified in all 8 cases by m-RNC. Leakage site was cervicothoracic junction (CTJ, n=3), CTJ with C1-2 (n=2), CTJ with thoracic spine, thoracolumbar spine and lumbar spine (each n=1). All cases presented leakage sites within 1 hour and multiple sites, where CTJ was included in 6 cases. Only one case presented additional site in 6 hour image. Early radioactivity within the urinary bladder was noted in 6 cases, but that was fellowing after identification of the leakage site. Conclusion: Radionuclide cisternography is sensitive to detect the leakage site of CSF and is expected to improve the detection of CSF leakage site and reduce time for the study using modified protocol.
Many clinical and laboratory tests have been employed to evaluate disease activity in rheumatioid arthritis. $^{99m}Tc$-labelled polyclonal IgG(HIG) has been demonstrated to accumulate in focal sites of infection or inflammation in both animals and human subjects. The purpose of this study was to distinguish arthritis with active inflammation from those without active inflammation and to correlate relative intensities of $^{99m}Tc$-labelled HIG uptake of the rheumatoid arthritis with clinical and MR indices of the joint inflammation. This study included twelve patients with active rheumatoid arthritis, two with ankylosing spondylitis and one with degenerative osteoarthritis without active inflammation. A Whole-body and spot images were obtained 4 hours after intravenous injection of 20mCi of $^{99m}Tc$-labelled HIG. Scintigrams were assessed visually by 3 experienced radiologists, and graded as normal or mildly and markedly increased uptake within the joints, and the degree of uptake was compared with clinical and radiologic severity of synovial inflammation. MRI studies were done on the involved joints consisted of wrist(n = 11), knee(n = 2) and hip joint(n= 2). Active synovitis was defined when marked elevation of ESR and gadolinium enhancement of synovium on MRI were demonstrated. Markedly increased radiotracer uptake was seen in 10 of 11 rheumatoid arthritic patients with active synovitis whereas normal or mildly increased uptakes were noted in others, including rheumatoid arthritic patient(n=1) and non-rheumatoid patients(n = 3) without active synovitis. This study showed that the localization of involved joints in rheumatoid arthritis could be detected with $^{99m}Tc$-labelled HIG and that the degree of uptake correlated well with the degree and activity of inflammation. In conclusion, $^{99m}Tc$-labelled HIG scan is a useful method in the evaluation of active inflammation in rheumatoid arthritis.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.