• Title/Summary/Keyword: Imaging studies

Search Result 1,638, Processing Time 0.032 seconds

Clinical characteristics of adverse reaction to radiocontrast media in children - A single center experience (소아에서 방사선 조영제 유해반응의 임상적 특징)

  • Kim, Min Jung;Lee, Bo Ra;Choi, Young Hun;Kang, Dong Yoon;Kang, Hye-Ryun;Suh, Dong In
    • Allergy, Asthma & Respiratory Disease
    • /
    • v.6 no.6
    • /
    • pp.315-321
    • /
    • 2018
  • Purpose: Radiocontrast media are widely used in medical imaging to improve diagnostic accuracy. However, studies on the adverse reactions of radiocontrast media in children are limited. We aimed to describe the characteristics of adverse reactions to radiocontrast media among children who had a computed tomography scan or magnetic resonance imaging in a tertiary university hospital. Methods: We retrospectively collected data on adverse reactions to radiocontrast media by the reporting system of a tertiary university hospital. We selected data from children under the age of 19 from July 2011 to December 2017 and analyzed their characteristics. We focused mainly on the characteristics of the index case which is defined by the first adverse event of each subject. Results: During the period, a total of 88,050 radiocontrast media-enhanced imaging studies were performed and 184 cases of adverse reactions were reported. A total of 71 were identified as index cases. Forty-nine (69.0%) were male and the mean age was $12.7{\pm}3.2$ years. The incidence of radiocontrast media-related adverse reactions was 0.09% and severe reactions were 0.002%. The most common clinical feature was skin manifestations (54.9%), followed by gastrointestinal symptoms (40.8%) and neuropsychiatric symptoms (7.4%). Conclusion: Adverse reactions to radiocontrast media rarely occur in children and the incidence of severe reactions is low. Most reactions are mild and are related to the skin and gastrointestinal system. This report would provide good evidence for establishing a management strategy in children scheduled for imaging studies using radiocontrast media.

Use of magnetic resonance imaging for evaluation of therapeutic response in breast cancer-related lymphedema: A systematic review

  • Forte, Antonio Jorge;Boczar, Daniel;Kassis, Salam;Huayllani, Maria T.;McLaughlin, Sarah A.
    • Archives of Plastic Surgery
    • /
    • v.47 no.4
    • /
    • pp.305-309
    • /
    • 2020
  • Breast cancer treatment-related lymphedema (BCRL) is a common comorbidity in breast cancer survivors. Although magnetic resonance imaging (MRI) is widely used to evaluate therapeutic response of patients with various medical conditions, it is not routinely used to evaluate lymphedema patients. We conducted a systematic review of the literature to identify studies on the use of MRI to evaluate therapy for BCRL. We hypothesized that MRI could provide information otherwise not possible through other examinations. On October 21, 2019, we conducted a systematic review on the PubMed/MEDLINE and Scopus databases, without time frame or language limitations, to identify studies on the use of MRI to evaluate therapy for BCRL. We excluded studies that investigated other applications of MRI, such as lymphedema diagnosis and surgical planning. Of 63 potential articles identified with the search, three case series fulfilled the eligibility criteria. In total, 53 patients with BCRL were included and quantitatively evaluated with MRI before and after manual lymphatic drainage. Authors used MRI or MR lymphagiography to investigate factors such as lymphatic vessel cross-sectional area, tissue water relaxation time (T2), and chemical exchange saturation transfer. The only study that compared MRI measurement with standard examinations reported that MRI added information to the therapy evaluation. MRI seems to be a promising tool for quantitative measurement of therapeutic response in patients with BCRL. However, the identified studies focused on only manual lymphatic drainage and were limited by the small numbers of patients. More studies are necessary to shed light on the topic.

Studies on the millimeter-wave Passive Imaging System III (밀리미터파 수동 이미정 시스템 연구 III)

  • Jung, Min-Kyoo;Chae, Yeon-Sik;Kim, Soon-Koo;Yoo, Jin-Seob;Koji, Mizuno;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.3 s.357
    • /
    • pp.111-116
    • /
    • 2007
  • We have developed a passive millimeter wave (PMMW) imaging system with two-dimensional imaging arrays. For the imaging system we achieved single-substrate imaging-array element which include all necessary component such as Fermi tapered slot antenna (TSA), a balun, LNA's and a detector circuit on it. Two-dimensional arrays for real-time imaging at the 35 GHz band are currently under development. We will be able to make an advanced PMMW image system based on our system with the $2\times2$ imaging array in the near future.

The Comparison of Appropriateness of Abdominal Computed Tomography (CT) and Abdominal Radiography Imaging Modality for Patients with Acute Nontraumatic Abdominal Pain (비외상성 급성 복부 통증 환자에게 시행한 복부 전산화단층촬 영과 복부 단순 촬영의 적정성 비교)

  • Song, Jung-Hup;Ryeom, Hun-Kyu
    • Quality Improvement in Health Care
    • /
    • v.24 no.2
    • /
    • pp.15-25
    • /
    • 2018
  • Purpose: To compare the Appropriateness of abdominal CT to abdominal radiography as an imaging modality in terms of the diagnostic value, medical costs and decision making times for patients presented to the emergency department with nontraumatic abdominal pain. Methods: This study used the records of 530 cases presented to the emergency department(ED) with nontraumatic abdominal pain from February to March 2012. Imaging modalities were categorized into abdominal radiography and CT (radiography first or CT first) or radiography alone or CT alone. The diagnostic value, total medical costs and effect on decision making time of the each imaging modalities were compared. Especially, in retrospective review, to evaluate the predictability of the abdominal radiography, alit was assumed that all the 530 cases performed that exam as initial imaging. Results: Among 530 cases, 255 cases underwent abdominal radiography only, 28 cases underwent abdominal CT only and the remnant 247 cases underwent abdominal CT with plain abdominal radiography. The diagnostic value was higher in the cases with abdominal CT (268/275, 97.5%) than in the cases with plain abdominal radiography (19/255, 7.5%).The number of cases predicted by abdominal radiography only as initial imaging were 39/530 (7.4%). In cases where the patients performed the abdominal CT as the first imaging modality thereby omitting the abdominal radiography, the total diagnostic imaging fee was lower than in cases with plain abdominal radiography first followed by the abdominal CT (277,140 vs. 284,226(mean, Korean Won)). Although diagnostic value of the plain abdominal radiography as first imaging modality was lower than the abdominal CT, Decision making time, average duration of hospital stay was longer and the total medical costs was higher than abdominal CT. Conclusion: As an imaging modality in the ED for patients with acute nontraumatic abdominal pain, plain abdominal radiography is an avoidable procedure when viewed in terms of the diagnostic value and total medical costs and decision making times comparing with abdominal CT.

Comparision of Imaging Features with Surgical Findings in the Patients with Craniosynostosis (두개골조기유합증 환자에서 영상소견과 수술소견의 비교)

  • Kim, Hyung Soo;Park, Se-Hyuck;Cho, Byung Moon;Oh, Sae-Moon
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.12
    • /
    • pp.1417-1421
    • /
    • 2001
  • Objective : The purposes of this study are to compare imaging features with operative findings and to determine significance of imaging studies for early detection of craniosynostosis(CS). Methods : Plain radiograph of skull and three-dimensional(3D) CT reconstruction were analyzed in 10 consecutive patients with CS to assess the presence and the extent of synostosis. The radiological findings were investigated and compared with operative findings. Results : The locations of lesion were coronal suture in 6, sagittal suture in 3 and multiple sutures in one patient, and the age ranged 1 to 53 months(mean age : 17.4 months). Reconstructive procedures with or without advancement of supraorbital rim were performed in coronal CS patients and ${\pi}$-procedures or synostectomy were done in sagittal CS patients. Radi-ological abnormalities such as sutural indistinctness or sclerosis, bony ridge, bossing and other bony deformities were nearly consistent with surgical findings. Conclusion : The interpretation of imaging study are very important for early detection of craniosynostosis, especially, the plain radiographs of skull. Also 3D CT imaging is helpful in diagnosis and surgical planing of craniosynostosis. There are no significant differences between imaging features and operative findings in CS patients.

  • PDF

The Role of Functional Imaging Techniques in the Dementia (치매 환자에서 기능 영상법의 역할)

  • Ryu, Young-Hoon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.209-217
    • /
    • 2004
  • Evaluation of dementia in patients with early symptoms of cognitive decline is clinically challenging, but the need for early, accurate diagnosis has become more crucial, since several medication for the treatment of mild to moderate Alzheimer' disease are available. Many neurodegenerative diseases produce significant brain function alteration even when structural imaging (CT or MRI) reveal no specific abnormalities. The role of PET and SPECT brain imaging in the initial assessment and differential diagnosis of dementia is beginning to evolve vapidly and growing evidence indicates that appropriate incorporation of PET into the clinical work up can improve diagnostic and prognostic accuracy with respect to Alzheimer's disease, the most common cause of dementia in the geriatric population. in the fast few years, studios comparing neuropathologic examination with PET have established reliable and consistent accuracy for diagnostic evaluations using PET - accuracies substantially exceeding those of comparable studies of diagnostic value of SPECT or of both modalities assessed side by side, or of clinical evaluations done without nuclear imaging. This review deals the role of functional brain imaging techniques in the evaluation of dementias and the role of nuclear neuroimaging in the early detection and diagnosis of Alzheimer's disease.

Development of Drugs and Technology for Radiation Theragnosis

  • Jeong, Hwan-Jeong;Lee, Byung Chul;Ahn, Byeong-Cheol;Kang, Keon Wook
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.597-607
    • /
    • 2016
  • Personalized medicine is tailored medical treatment that targets the individual characteristics of each patient. Theragnosis, combining diagnosis and therapy, plays an important role in selecting appropriate patients. Noninvasive in vivo imaging can trace small molecules, antibodies, peptides, nanoparticles, and cells in the body. Recently, imaging methods have been able to reveal molecular events in cells and tissues. Molecular imaging is useful not only for clinical studies but also for developing new drugs and new treatment modalities. Preclinical and early clinical molecular imaging shows biodistribution, pharmacokinetics, mechanisms of action, and efficacy. When therapeutic materials are labeled using radioisotopes, nuclear imaging with positron emission tomography or gamma camera can be used to treat diseases and monitor therapy simultaneously. Such nuclear medicine technology is defined as radiation theragnosis. We review the current development of drugs and technology for radiation theragnosis using peptides, albumin, nanoparticles, and cells.

Parallel Processing for Integral Imaging Pickup Using Multiple Threads

  • Jang, Young-Hee;Park, Chan;Park, Jae-Hyeung;Kim, Nam;Yoo, Kwan-Hee
    • International Journal of Contents
    • /
    • v.5 no.4
    • /
    • pp.30-34
    • /
    • 2009
  • Many studies have been done on the integral imaging pickup whose objective is to get efficiently elemental images from a lens array with respect to three-dimensional (3D) objects. In the integral imaging pickup process, it is necessary to render an elemental image from each elemental lens in a lens array for 3D objects, and then to combine them into one total image. The multiple viewpoint rendering (MVR) is one of various methods for integral imaging pickup. This method, however, has the computing and rendering time problem for obtaining element images from a lot of elemental lens. In order to solve the problems, in this paper, we propose a parallel MVR (PMVR) method to generate elemental images in a parallel through distribution of elemental lenses into multiple threads simultaneously. As a result, the computation time of integral imaging using PMVR is reduced significantly rather than a sequential approach and then we showed that the PMVR is very useful.

Upgrade of gamma electron vertex imaging system for high-performance range verification in pencil beam scanning proton therapy

  • Kim, Sung Hun;Jeong, Jong Hwi;Ku, Youngmo;Jung, Jaerin;Cho, Sungkoo;Jo, Kwanghyun;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • v.54 no.3
    • /
    • pp.1016-1023
    • /
    • 2022
  • In proton therapy, a highly conformal proton dose can be delivered to the tumor by means of the steep distal dose penumbra at the end of the beam range. The proton beam range, however, is highly sensitive to range uncertainty, which makes accurately locating the proton range in the patient difficult. In-vivo range verification is a method to manage range uncertainty, one of the promising techniques being prompt gamma imaging (PGI). In earlier studies, we proposed gamma electron vertex imaging (GEVI), and constructed a proof-of-principle system. The system successfully demonstrated the GEVI imaging principle for therapeutic proton pencil beams without scanning, but showed some limitations under clinical conditions, particularly for pencil beam scanning proton therapy. In the present study, we upgraded the GEVI system in several aspects and tested the performance improvements such as for range-shift verification in the context of line scanning proton treatment. Specifically, the system showed better performance in obtaining accurate prompt gamma (PG) distributions in the clinical environment. Furthermore, high shift-detection sensitivity and accuracy were shown under various range-shift conditions using line scanning proton beams.

Anxiety and Norepinephrine System (불안과 노어에피네프린)

  • Sim, Hyun-Bo;Yu, Bum-Hee
    • Anxiety and mood
    • /
    • v.2 no.1
    • /
    • pp.3-8
    • /
    • 2006
  • Anxiety has been suggested to be related to many neurotransmitters in brain, such as norepinephrine, serotonin, dopamine, cholecystokinin, and gamma-amino butyric acid. There are many studies to examine the relationship between anxiety and norepinephrine, and norepinephrine seems to be clearly related to the development of anxiety. We suggest that future studies to explore the pathophysiology of anxiety should be necessary, which include studies on antianxiety drugs, genetic studies, animal model studies, and brain imaging studies.

  • PDF