• Title/Summary/Keyword: Imaging Sensor

Search Result 499, Processing Time 0.033 seconds

Comparison of Gold Biosensor Combined with Light Microscope Imaging System with ELISA for Detecting Salmonella in Chicken after Exposure to Simulated Chilling Condition

  • Mi-Kyung Park
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.2
    • /
    • pp.228-234
    • /
    • 2023
  • In this study, the performance of a gold biosensor combined with light microscope imaging system (GB-LMIS) was comparatively evaluated against enzyme-linked immunosorbent assay (ELISA) for detecting Salmonella under simulated chilling condition. The optimum concentration of antiSalmonella polyclonal antibodies (pAbs) was determined to be 12.5 and 100 ㎍/ml for ELISA and GBLMIS, respectively. GB-LMIS exhibited a sufficient and competitive specificity toward three tested Salmonella among only. To mimic a real-world situation, chicken was inoculated with Salmonella cocktail and stored under chilling condition for 48 h. The overall growth of Salmonella under chilling condition was significantly lower than that under non-exposure to the chilling condition (p < 0.05). No significant differences in bacterial growth were observed between brain heart infusion and brilliant green broth during the enrichment period (p > 0.05). Finally, both GB-LMIS and ELISA were employed to detect Salmonella at every 2-h interval. GB-LMIS detected Salmonella with a competitive specificity by the direct observation of bacteria on the sensor using a charge-coupled device camera within a detection time of ~2.5 h. GB-LMIS is a feasible, novel, and rapid method for detecting Salmonella in poultry facilities.

Error analysis of 3-D surface parameters from space encoding range imaging (공간 부호화 레인지 센서를 이용한 3차원 표면 파라미터의 에러분석에 관한 연구)

  • 정흥상;권인소;조태훈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.375-378
    • /
    • 1997
  • This research deals with a problem of reconstructing 3D surface structures from their 2D projections, which is an important research topic in computer vision. In order to provide robust reconstruction algorithm, that is reliable even in the presence of uncertainty in the range images, we first present a detailed model and analysis of several error sources and their effects on measuring three-dimensional surface properties using the space encoded range imaging technique. Our approach has two key elements. The first is the error modeling for the space encoding range sensor and its propagation to the 3D surface reconstruction problem. The second key element in our approach is the algorithm for removing outliers in the range image. Such analyses, to our knowledge, have never attempted before. Experimental results show that our approach is significantly reliable.

  • PDF

Comparative Study of Sonar Image Processing for Underwater Navigation (항법 적용을 위한 수중 소나 영상 처리 요소 기법 비교 분석)

  • Shin, Young-Sik;Cho, Younggun;Lee, Yeongjun;Choi, Hyun-Taek;Kim, Ayoung
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.3
    • /
    • pp.214-220
    • /
    • 2016
  • Imaging sonars such as side-scanning sonar or forward-looking sonar are becoming fundamental sensors in the underwater robotics field. However, using sonar images for underwater perception presents many challenges. Sonar images are usually low resolution with inherent speckled noise. To overcome the limited sensor information for underwater perception, we investigated preprocessing methods for sonar images and feature detection methods for a nonlinear scale space. In this paper, we focus on a comparative analysis of (1) preprocessing for sonar images and (2) the feature detection performance in relation to the scale space composition.

Development of Laser Speckle Flowgraphy System for Monitoring Blood Flow in Skin Tissue (레이저 산란 현상을 이용한 피부혈류 화상화 시스템의 개발)

  • Lee, M.C.;Fujii, H.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.392-396
    • /
    • 2007
  • In this paper, we develop a new system to visualize the blood flow map in skin tissue, using the technique of Laser Speckle Flowgraphy (LSFG). The measuring unit consists of the laser diode, imaging system, line sensor, scanning mirror, and one-board microcomputer. The speckle signal is analyzed and sent to a PC, where the blood flow in a tissue area of $14mm{\times}26 mm$ is evaluated and displayed in a 2-D color map. It is demonstrated that the new LSFG instrument is useful to evaluate the degree of allergic reaction in patch test.

INITIAL GEOMETRIC ACCURACY OF KOMPSAT-2 HIGH RESOLUTION IMAGE

  • Seo, Doo-Chun;Lim, Hyo-Suk;Shin, Ji-Hyeon;Kim, Moon-Gyu
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.780-783
    • /
    • 2006
  • The KOrea Multi-Purpose Satellite-2 (KOMPSAT-2) was launched in July 2006 and the main mission of the KOMPSAT-2 is a high resolution imaging for the cartography of Korea peninsula by utilizing Multi Spectral Camera (MSC) images. The camera resolutions are 1 m in panchromatic scene and 4 m in multi-spectral imaging. This paper provides an initial geometric accuracy assessment of the KOMPSAT-2 high resolution image without ground control points and briefly introduces the sensor model of KOMPSAT-2. Also investigated and evaluated the obtained 3-dimensional terrain information using the MSC pass image and scene images acquired from the KOMPSAT-2 satellite.

  • PDF

Color accuracy of imaging using color filters

  • Boher, P.;Leroux, T.;Patton, V. Collomb;Bignon, T.
    • Journal of Information Display
    • /
    • v.13 no.1
    • /
    • pp.7-16
    • /
    • 2012
  • In this paper, the problem concerning the color accuracy of imaging systems using color filters is examined. It is shown that the only solution to the problem is to build systems with the spectral response matching the CIE curves as closely as possible. If the spectral response does not closely match the CIE curves, it was demonstrated that calibration cannot solve the problem and will result in very unstable colorimeters. A practical solution that uses telecentric lenses on the sensor side in addition to dedicated color filters for each CCD detector is presented. For systems that closely match the CIE curves, an innovative method of improving the color accuracy based on the precise measurement of the spectral response is presented. The small discrepancies in the spectral response with regard to the CIE curves are corrected in different ways during the measurements. Finally, it is shown that the tristimulus calibration that is used for display measurement is very unstable for systems without CIE matching and is much more stable with systems that closely match the CIE curves.

RADIATION SAFETY STUDIES AT TOHOKU UNIVERSITY CYRIC

  • Yamadera M. Baba A.;Miura T.;Aoki T.;Hagiwara M.;Kawata N.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.231-236
    • /
    • 2001
  • A brief introduction is presented on the radiation safety studies at Tohoku University Cyclotron & Radioisotope Center. Studies on two subject are described; (1) measurement of the thick target neutron yield and radioisotope production / activation cross section for ten's of MeV neutrons and ions using K=110 Tohoku University cyclotron to provide basicdata for accelerator shielding, and (2) development of techniques for high sensitive radiation detection and profile measurement using an Imaging Plate which is a high sensitive two-dimensional radiation sensor. Application of the Imaging Plate techniques to localization of very weak radioactivity and to neutron profile measurement is described.

  • PDF

A Study on the Development of the System for Inspecting Cracks in the Inner Wall for Structures (구조물 내벽의 균열 검사를 위한 시스템 개발에 관한 연구)

  • 이상호;신동익;손영갑;이강문;마상준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.480-483
    • /
    • 1997
  • In this paper, we have proposed an automatic inspection system for cracks on the surface of a structure. The proposed system consists of the imaging system and the veh~cle system. The imaging system. a set of optical sensor, lens, illuminator, storage and their configuration, images the scene and store it on the hard disk. We adopted a linescan camera of 5000 pixel density to achieve high resolution without loss of simplicity. The vehicle system that moves the optical system IS ~mplemented by an AGV. The AGV moves forward at constant velocity and avoid obstacles to acquire a stable image. We have cmplemented an experimental system and have acquired images of the wall of hallway. The image is of 0.1-mmipixel resolution and the scanning time IS about 1 mlsec. The allow able scan.

  • PDF

Optical Setup for Full-Field Imaging Test of MATS Limb Telescope

  • Lee, Sunwoo;Hammar, Arvid;Park, Woojin;Chang, Seunghyuk;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.68.3-68.3
    • /
    • 2018
  • The MATS (Mesosphere Airglow / Aerosol Tomography Spectroscopy) satellite is a Swedish scientific microsatellite which Kyung Hee University participates in developing. The limb telescope of the MATS satellite is designed with linear astigmatism-free off axis optical configuration which allows wide field of view ($5.67^{\circ}{\times}0.91^{\circ}$). Here we present the full-field optical performance test setup that consists of a point source, a collimator, the limb telescope and a CCD (Charged Coupled Device). The incidence angle of the collimator was carefully controlled by the rotary stage under the limb telescope. The imaging tests represent expected results without dominant aberrations.

  • PDF

A Study of Image Target Detection and Tracking for Robust Tracking in an Occluded Environment (표적의 부분가림이 존재하는 환경에서 견실한 추적을 위한 영상 표적 탐지, 추적 알고리듬 연구)

  • Kim, Yong;Song, Taek-Lyul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.10
    • /
    • pp.982-990
    • /
    • 2010
  • In a target tracking system using image information from a CCD (Charged Couple Device) or an IIR (Imaging Infra-red) sensor, occluded targets can result in track losses. If the target is occlued by background objects such as buildings or trees, probability of track existence will be reduced sharply and track will be terminated due to track maintenance algorithms. This paper proposes data association algorithm based on target existence for the robust tracking performance. we suggest the HPDA (Highest Probability Data Association) algorithm based on target existence and the tracking performance is compared with the established method based on target perceivability. Image tracking simulation that utilizes virtual 3D images and real IR images is employed to evaluate the robustness of the proposed tracking algorithm.