• Title/Summary/Keyword: Imaging Module

Search Result 129, Processing Time 0.031 seconds

Development of Automatic Visual Inspection for the Defect of Compact Camera Module

  • Ko, Kuk-Won;Lee, Yu-Jin;Choi, Byung-Wook;Kim, Johng-Hyung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2414-2417
    • /
    • 2005
  • Compact Camera Module(CCM) is widely used in PDA, Celluar phone and PC web camera. With the greatly increasing use for mobile applications, there has been a considerable demands for high speed production of CCM. The major burden of production of CCM is assembly of lens module onto CCD or CMOS packaged circuit board. After module is assembled, the CCM is inspected. In this paper, we developed the image capture board for CCM and the imaging processing algorithm to inspect the defects in captured image of assembled CCMs. The performances of the developed inspection system and its algorithm are tested on samples of 10000 CCMs. Experimental results reveal that the proposed system can focus the lens of CCM within 5s and we can recognize various types of defect of CCM modules with good accuracy and high speed.

  • PDF

The development of a fully automated homemade system for [11C] acetate synthesis using an open source PLC

  • Kang, Se Hun;Hong, Sung Tack;Park, Kwangseo;Kim, Seok-ki
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.2 no.2
    • /
    • pp.103-107
    • /
    • 2016
  • Solid phase extraction (SPE) purification method is the efficient and well-known tool for automated [$^{11}C$]acetate synthesis. A fully automated homemade module adopting the SPE method and 'pinch' valves was developed very economically with a universal interface board, a relay card and an open source programmable logic controller. The radiochemical yield of the optimized [$^{11}C$]acetate synthesis by this system was $58.8{\pm}2.1%$ (n=10, decay-corrected) from $15.5{\pm}0.19GBq$ of $[^{11}C]CO_2$ as starting activity, and total synthetic time was 15 minutes. HPLC analysis showed its high radiochemical purity as $97.4{\pm}1.1%$ without possible by-products.

HYPERSPECTRAL IMAGING SPECTROMETER WITH A NOVEL ZOOMING FUNCTION

  • Choi Jin;Kim Tae Hyung;Kong Hong Jin;Lee Jong-Ung
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.213-216
    • /
    • 2005
  • A novel hyperspectral imaging spectrometer controlling spatial and spectral resolution individually has been proposed. This imaging spectrometer uses a zoom lens as a telescope and a focusing element. It can change the spatial resolution fixing the spectral resolution or the spectral resolution fixing the spatial resolution. Here, we report the concept of the hyperspectral imaging spectrometer with the novel zooming function and the optical design of a zoom lens as the focusing element. By using lens module and third-order aberration theory, we have presented the initial design of four-group zoom lens with external entrance pupil. And the optimized zoom lens with a focal length of 50 to 150 mm is obtained from the initial design by the optical design software. As a result, the designed zoom lens shows satisfactory performances in wavelength range of 450 to 900 nm as a focusing element in an imaging spectrometer. Furthermore, the collimator lens of the imaging spectrometer is designed through the third-order aberration correction by using an iterative process.

  • PDF

Development and Packaging of Multi-channel Imaging Module for Near-infrared Fluorescence Imaging System (근적외선 형광 영상 시스템용 다채널 영상 모듈 개발 및 패키징)

  • Kim, Taehoon;Seo, Kyung Hwan;Lee, Hak Keun;Jeong, Myung Yung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.2
    • /
    • pp.59-64
    • /
    • 2019
  • In this paper, we introduced a near-infrared multi-channel fluorescence imaging system and analyzed the effects of measurements variables such as exposure time, working distance and intensity of excitation light. Fluorescence signal is increased as exposure time becomes longer, excitation light intensity increases or working distance becomes smaller. Furthermore, the proper composition of optical filters and precise packaging of the imaging modules prevent the increase of background signal. Thus, we confirmed an increase in SBR. Based on the result of this research, we proposed a method to use a multi-channel fluorescence imaging system.

A Study on the 300MHz NMR Transceiver (300MHz급 NMR Transceiver 설계 및 제작)

  • Park, Yang-Ha;Jin, Seung-Oh;Won, Jin-Im;Huh, Young
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3210-3212
    • /
    • 2000
  • We designed and manufactured 300MHz NMR RF Transceiver. NMR system is composed of NMR Spectrometer, Superconductive Magnet and Pulse Programmer, GUI. NMR RF Transceiver is composed of transmitter, receiver, frequency synthesizer. T/R switch, main power amp., RF coil. To phase modulation, transmitter is composed of mixer, splitter and combiner et al. To weak signal detection, receiver is composed of pre-amp., filter, mixer et al. Each module is manufactured PCB. And installed NMR system to detect chemical component of specimen. In result, we can get the information of specimen.

  • PDF

A Study on the Design and Implementation of a Thermal Imaging Temperature Screening System for Monitoring the Risk of Infectious Diseases in Enclosed Indoor Spaces (밀폐공간 내 감염병 위험도 모니터링을 위한 열화상 온도 스크리닝 시스템 설계 및 구현에 대한 연구)

  • Jae-Young, Jung;You-Jin, Kim
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.12 no.2
    • /
    • pp.85-92
    • /
    • 2023
  • Respiratory infections such as COVID-19 mainly occur within enclosed spaces. The presence or absence of abnormal symptoms of respiratory infectious diseases is judged through initial symptoms such as fever, cough, sneezing and difficulty breathing, and constant monitoring of these early symptoms is required. In this paper, image matching correction was performed for the RGB camera module and the thermal imaging camera module, and the temperature of the thermal imaging camera module for the measurement environment was calibrated using a blackbody. To detection the target recommended by the standard, a deep learning-based object recognition algorithm and the inner canthus recognition model were developed, and the model accuracy was derived by applying a dataset of 100 experimenters. Also, the error according to the measured distance was corrected through the object distance measurement using the Lidar module and the linear regression correction module. To measure the performance of the proposed model, an experimental environment consisting of a motor stage, an infrared thermography temperature screening system and a blackbody was established, and the error accuracy within 0.28℃ was shown as a result of temperature measurement according to a variable distance between 1m and 3.5 m.

duoPIXTM X-ray Imaging Sensor Composing of Multiple Thin Film Transistors in a Pixel for Digital X-ray Detector (픽셀내 다수의 박막트랜지스터로 구성된 듀오픽스TM 엑스선 영상센서 제작)

  • Seung Ik, Jun;Bong Goo, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.969-974
    • /
    • 2022
  • In order to maximize dynamic range and to minimize image lag in digital X-ray imaging, diminishing residual parasitic capacitance in photodiode in pixels is critically necessary. These requirements are more specifically requested in dynamic X-ray imaging with high frame rate and low image lag for industrial 2D/3D automated X-ray inspection and medical CT imaging. This study proposes duoPIXTM X-ray imaging sensor for the first time that is composed of reset thin film transistor, readout thin film transistor and photodiode in a pixel. To verify duoPIXTM X-ray imaging sensor, designing duoPIXTM pixel and imaging sensor was executed first then X-ray imaging sensor with 105 ㎛ pixel pitch, 347 mm × 430 mm imaging area and 3300 × 4096 pixels (13.5M pixels) was fabricated and evaluated by using module tester and image viewer specifically for duoPIXTM imaging sensor.

CMM(Compact Camera Module) Defect Inspection (CMM(Compact Camera Module) 불량 검사)

  • 고국원;이유진;최병욱;고경철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.585-589
    • /
    • 2004
  • This paper deals with the algorithm development that inspects defects such as Lens Focus, Black Defect, Dim Defect, Color Defect, White Balance, and Line Defect caused by the process of Compact Camera Module (CCM). These days the demand of CCM goes on increasing in various types like PDA, a cellular phone and PC camera every year. However, owing to the defect inspection of CCM by the semiskilled work the average inspection time of CCM takes about 40 to 50 seconds. As time goes by the efficiency takes a sudden turn for the worse because workers must inspect with seeing a monitor directly. In this paper, to solve these problems, we developed the imaging processing algorithm to inspect the defects in captured image of assembled CCM. The performances of the developed inspection system and its algorithm are tested on many samples. Experimental results reveal that the proposed system can focus the lens of CCM within 5s and we can recognize various types of defect of CCM modules with good accuracy and high speed.

  • PDF

Live Electrooptic Imaging Camera for Real-Time Visual Accesses to Electric Waves in GHz Range

  • Tsuchiya, Masahiro;Shiozawa, Takahiro
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.4
    • /
    • pp.290-297
    • /
    • 2011
  • Recent progresses in the live electrooptic imaging (LEI) technique are reviewed with emphasis on its functionality of real-time visual accesses to traveling electric waves in the GHz range. Together with the principles, configurations, and procedures for the visual observation experiments by an LEI camera system, the following results are described as examples indicating the wide application ranges of the technique; Ku-band waves on arrayed planar antennas, waves on a Gb/s-class digital circuit, W-band waves traveling both in slab-waveguide modes and aerially, backward-traveling wave along composite right/left-handed transmission line, and, waves in monolithic microwave integrated circuit module case.

Image Quality Evaluation and Tolerance Analysis for Camera Lenses with Diffractive Element

  • Lee, Sang-Hyuck;Jeong, Ho-Seop;Jin, Young-Su;Song, Seok-Ho;Park, Woo-Je
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.105-111
    • /
    • 2006
  • A novel image quality evaluation method, which is based on combination of the rigorous grating diffraction theory and the ray-optic method, is proposed. It is applied for design optimization and, tolerance analysis of optical imaging systems implementing diffractive optical elements (DOE). The evaluation method can predict the quality and resolution of the image on the image sensor plane through the optical imaging system. Especially, we can simulate the effect of diffraction efficiencies of DOE in the camera lenses module, which is very effective for predicting different color sense and MTF performance. Using this method, we can effectively determine the fabrication tolerances of diffractive and refractive optical elements such as the variations' in profile thickness, and the shoulder of the DOE, as well as conventional parameters such as decenter and tilt in optical-surface alignments. A DOE-based 2M-resolution camera lens module designed by the optimization process based on the proposed image quality evaluation method shows ${\sim}15%$ MTF improvement compared with a design without such an optimization.