• Title/Summary/Keyword: Imaging, Three Dimensional

Search Result 710, Processing Time 0.027 seconds

Comparison of the Effects of Straight and Twisted Heat Trace Installations Based on Three-dimensional Unsteady Heat Transfer (열선의 직선시공과 감기시공의 동파방지 효과 비교를 위한 3차원 비정상 수치해석)

  • Choi, Myoung-Young;Jeon, Byoung-Jin;Choi, Hyoung-Gwon
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.49-56
    • /
    • 2016
  • This paper numerically examines, straight and twisted electrical heat trace installations for their anti-freezing effects on water inside a pipe. The unsteady incompressible Navier-Stokes equations coupled with an energy equation were solved to compare the two installation methods. The heat conduction of the pipe with a heat source interacts with the natural convection of the water, and the conjugate heat transfer was considered using a commercial code (ANSYS-FLUENT) based on a SIMPLE-type algorithm. Numerical experiments, were done to investigate the isotherms and the vector fields in the water region to extract the evolutions of the minimum and maximum temperatures of the water inside the pipe. There was no substantial difference in the anti-freezing effects between the straight and twisted. Therefore, the straight installation is recommended after considering the damage and short circuit behavior of the electrical heat trace.

Study of bony trabecular characteristics using bone morphometry and micro-CT (골형태분석법과 micro-CT를 이용한 골소주 특성에 대한 연구)

  • Song, Young-Han;Lee, Wan;Lee, Chang-Jin;Ji, Jung-Hyun;Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.37 no.1
    • /
    • pp.27-33
    • /
    • 2007
  • Purpose : The research was done to investigate the effectiveness of 2D bony morphometry and microstructure of micro-computed tomography (micro-CT) on the osteoporotic bony change. We performed the bone morphometric analysis of proximal femur in ovariectomized rabbits with BMD and micro-CT examination. Materials and Methods : Twenty-one female (Newzealand, about 16 weeks old, 2.9-3.4kg) rabbits were used. Three rabbits were sacrificed on the day when experiment began (Baseline). The remaining 18 rabbits were divided into two groups. One group was ovariectomized bilaterally (OVX) and the other animals were subjected to sham operation (Sham). Bone specimens were obtained from the right and left femur of sacrificed rabbits. At intervals of 1, 2, 3, 5, 6 months respectively, BMD tests were performed on the proximal femur by using PIXlmus 2 (GE Lunar Co. USA), 2-dimensional bone morphometric analysis by custome computer program and 2D/3D bone structure analysis by micro-CT (Skyscan 1072, Antwerpen, Belgium). Statistical analysis was carried out for the correlation between bone morphometry, micro-CT and BMD Result : BV/TV, Tb.Th, Tb.N of micro-CT parameters showed higher values in sham group than OVX group. N.Nd/Ar.RI, N.NdNd, N.NdTm, N. TmTm, PmB/Ar.RI, 3-D BoxSlope of 2D morphometric parameters showed higher values in Sham group than OVX group. The micro-CT parameters of Tb.Sp, Tb.N were statistically significant correlated with BMD respectively. Several 2D morphometric parameters were statistically significant correlated with BMD respectively. Conclusion : Several parameters of 2D bony morphometry and micro-CT showed effective aspects on the osteoporotic bony change.

  • PDF

Analysis on correlation between bone strength by FEA, micro-CT parameters and bone mineral density (유한요소법에 의한 골강도와 micro-CT 지표 및 골밀도간의 상관관계)

  • Yoon, Young-Nam;Lee, Wan;Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.37 no.1
    • /
    • pp.53-59
    • /
    • 2007
  • Purpose : Bone mineral density (BMD) and bone microarchitecture are important determinants for bone strength. Recently micro-CT have provided possibilities for measuring a variety of structural indices to characterize bone microarchitecture. The objective of this study was to compare the BMD and micro-CT parameters with Young's modulus calculated by finite element analysis (FEA) for the evaluation of bone strength. Materials and Methods Bone specimens were obtained from the 18 female rabbits aged 16 weeks. Of those, 36 samples (right and left femur) were selected for 3D micro-CT analysis $(ANT^{TM},\;SKYSCAN,\;Belgium)$ and BMD by PIXlmus 2 (GE Lunar Co. USA). Five microstructural parameters of micro-CT, such as trabecular thickness (Tb.Th), bone specific surface (BS/BV), percent bone volume (BV/TV), structure model index (SMI) and degree of anisotropy (DOA) were studied. Young's modulus was obtained by software program (ANSYS 9.0, ANSYS Inc, Canonsburg, PA) based on micro-CT three dimensional images. Results : Young's modulus assessed by FEA correlated significantly with Tb.Th, BV/TV, BS/BV and SMI respectively. Young's modulus showed higher correlation with these rnicrostructural parameters of micro-CT than BMD. Microstructural parameters except DOA showed significant correlations within the examined group. Conclusion The microarchitectural parameters o( micro-CT and BMD represented some informations in the evaluation of bone strength assessed by FEA.

  • PDF

Three-dimensional evaluation of the mandibular symphyseal region in block graft harvesting for dental implants using cone-beam computed tomography

  • Gandhi, Vaibhav;Lowney, Arianna;Cardarelli, Lauren;Yadav, Sumit;Tadinada, Aditya
    • Imaging Science in Dentistry
    • /
    • v.50 no.3
    • /
    • pp.217-226
    • /
    • 2020
  • Purpose: The purpose of this study was to analyze the quantity and quality of the mandibular anterior alveolar bone in terms of alveolar width, density, and total alveolar height (TAH) based on dental status, gender, and age. Additionally, this study aimed to quantitatively evaluate the available alveolar height for graft harvesting (AHGH) and examine its variability based on the aforementioned factors. Materials and Methods: This retrospective cone-beam computed tomographic study included a total of 100 subjects. On the basis of gender, dental status, and age, the scans were divided into 3 primary groups and 8 subgroups. The mandibular alveolar width and density were measured 5 mm mesial to the mental foramen bilaterally and at the midline. The TAH was measured at the midline, and the AHGH was measured as the midline distance between 5 mm apical to the root of the canines and 5 mm superior to the lower border. Results: The mandibular alveolar width was statistically similar between dentulous and edentulous patients (P>0.05). A significantly greater density was observed at the midline in edentulous patients (P<0.05). The TAH was significantly greater in edentulous male patients than in edentulous female patients (P<0.05). Dentulous and male patients had significantly greater AHGH than edentulous and female patients, respectively (P<0.05). Conclusion: Based on the data evaluated in this study, it can be concluded that the mandibular symphyseal area has adequate bone quality and quantity for bone graft harvesting for dental implant therapy.

3-D Multiple-Input Multiple-Output Interferometric ISAR Imaging (3차원 Multiple-Input Multiple-Output 간섭계 ISAR 영상형성기법)

  • Kang, Byung-Soo;Bae, Ji-Hoon;Yang, Eun-Jung;Kim, Kyung-Tae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.6
    • /
    • pp.564-571
    • /
    • 2015
  • In this paper, we propose a multiple-input, multiple-output(MIMO) interferometric radar network system to generate three-dimensional (3-D) MIMO interferometric inverse synthetic aperture radar(InISAR) image. In the MIMO interferometric radar network system, the MIMO InISAR image can be formed by an incoherent summation of multiple bistatic InISAR images that show 3-D scatterers of a target observed at different bistatic interfermetric configurations, respectively. Because bistatic-sccattering physics of a target at different viewpoints are visible in the 3-D MIMO InISAR image, it can provide various scatterering physics properties of a target, and can be used for target classification as a useful feature vector. Simulations validate that our proposed method successfully finds locations of scatterers of a target in MIMO radar interferometric network system.

Quantification of Microstructures in Mice Alveolar Bone using Micro-computed tomography (${\mu}CT$)

  • Park, Hae-Ryoung;Kim, Hyun-Jin;Park, Byung-Ju
    • International Journal of Oral Biology
    • /
    • v.38 no.3
    • /
    • pp.87-92
    • /
    • 2013
  • Periodontal inflammation increases the risk of tooth loss, particularly in cases where there is an associated loss of alveolar bone and periodontal ligament (PDL). Histological and morphometric evaluation of periodontal inflammation is difficult. Especially, the lengths of the periodontal ligament and interdental alveolar bone space have not been quantified. A quantitative imaging procedure applicable to an animal model would be an important clinical study. The purpose of this study was to quantify the loss of alveolar bone and periodontal ligament by evaluation with micro-computed tomography (micro-CT). Another purpose was to investigate differences in infections with systemic E. coli LPS and TNF-${\alpha}$ on E. coli lipopolysaccharide (LPS) in loss of alveolar bone and periodontal ligament model on mice. This study showed that linear measurements of alveolar bone loss were represented with an increasing trend of the periodontal ligament length and interdental alveolar process space. The effects of systemic E. coli LPS and TNF-${\alpha}$ on an E. coli LPS-induced periodontitis mice model were investigated in this research. Loss of periodontal ligament and alveolar bone were evaluated by micro-computed tomography (micro-CT) and calculated by the two- and three dimensional microstructure morphometric parameters. Also, there was a significantly increasing trend of the interdental alveolar process space in E. coli LPS and TNF-${\alpha}$ on E. coli LPS compared to PBS. And E. coli LPS and TNF-${\alpha}$ on E. coli LPS had a slightly increasing trend of the periodontal ligament length. The increasing trend of TNF-${\alpha}$ on the LPS-induced mice model in this experiment supports the previous studies on the contribution of periodontal diseases in the pathogenesis of systemic diseases. Also, our findings offer a unique model for the study of the role of LPS-induced TNF-${\alpha}$ in systemic and chronic local inflammatory processes and inflammatory diseases. In this study, we performed rapidly quantification of the periodontal inflammatory processes and periodontal bone loss using micro-computed tomography (micro-CT) in mice.

Maxillary sinus pneumatization after maxillary molar extraction assessed with cone beam computed tomography (Cone Beam형 전산화단층영상을 이용한 상악대구치 발치 후 상악동 함기화 평가)

  • Jung, Yun-Hoa;Nah, Kyung-Soo;Cho, Bong-Hae
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.109-113
    • /
    • 2009
  • Purpose : The purpose of this study was to examine the inferior expansion of the maxillary sinus floor following maxillary molar extraction. Materials and Methods : Cone beam computed tomographic images of 59 subjects were used to evaluate the height difference of the maxillary sinus floor between extraction sites and contralateral dentate sites. The height of the maxillary sinus floor was defined as the vertical distance to the Frankfort plane from the level of the anterior nasal spine to the most inferior point of the sinus floor. We examined the difference in sinus pneumatization according to the number of missing teeth and the vertical relationship of the molar roots to the sinus floor. Results : The inferior expansion of the maxillary sinus floor was $1.20{\pm}1.86\;mm$ on the maxillary first molar and $1.90{\pm}2.42\;mm$ on the maxillary second molar. Increased expansion was observed in cases where two proximate molars were extracted. There was no significant difference in sinus pneumatization following extraction according to the vertical relationship of the molar roots to the sinus floor. Conclusion : The results of this study confirm that sinus pneumatization occurs following maxillary molar extraction. In situations where pneumatization can affect treatment after molar extraction, three-dimensional radiography should be considered.

  • PDF

Efficient image-stitching using preprocessing for a super resolution image (전처리를 활용한 고해상도 영상을 위한 효율적인 영상 스티칭)

  • Bae, JoungEun;Yoo, Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.9
    • /
    • pp.1738-1743
    • /
    • 2017
  • This paper presents an efficient image stitching method using preprocessing in order to generate a super resolution image. Two-dimensional (2D) scanners are consistently used in various areas but they have limitations such as paper sizes and materials. To overcome these problem with low-cost, an efficient imaging stitching method is proposed for producing a super resolution panorama image. To scan a very large sized paper using mobile phones, a simple portable cradle which fixes height is employed producing an input image set. To improve matching performance, a preprocessing method is introduced before searching correspondences. Then alpha blending is applied to an input image set to produce a super resolution panorama image. The proposed method is faster and easier than the existing method which is employed by Open CV. Experiment results show that the proposed method is three times faster and performs better than the existing method.

Biomimetic approach object detection sensors using multiple imaging (다중 영상을 이용한 생체모방형 물체 접근 감지 센서)

  • Choi, Myoung Hoon;Kim, Min;Jeong, Jae-Hoon;Park, Won-Hyeon;Lee, Dong Heon;Byun, Gi-Sik;Kim, Gwan-Hyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.91-93
    • /
    • 2016
  • From the 2-D image extracting three-dimensional information as the latter is in the bilateral sibeop using two camera method and when using a monocular camera as a very important step generally as "stereo vision". There in today's CCTV and automatic object tracking system used in many medium much to know the site conditions or work developed more clearly by using a stereo camera that mimics the eyes of humans to maximize the efficiency of avoidance / control start and multiple jobs can do. Object tracking system of the existing 2D image will have but can not recognize the distance to the transition could not be recognized by the observer display using a parallax of a stereo image, and the object can be more effectively controlled.

  • PDF

Phase Unwrapping using Modified Goldstein Algorithm in Digital Holography (디지털 홀로그래피에서의 수정된 골드스타인 알고리즘을 이용한 위상펼침)

  • Yoon, Seon-Kyu;Cho, Hyung-Jun;Kim, Doo-Cheol;Yu, Young-Hun;Kim, Sung-Kyu
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.2
    • /
    • pp.122-129
    • /
    • 2007
  • Generally, many kinds of phase unwrapping algorithm are used to obtain three-dimensional features in digital holography. The Goldstein algorithm is ra epresentative method. which requires small memory capacity and short execution time fer an unwrapping process. However, the Goldstein algorithm has some problems when the dipole residue is located at the boundary. When the opposite residues are located at the boundary and the distance between the opposite residues is longer than the boundary, an incorrect branch cut occurs and results in incorrect calculation. We have modified the Goldstein algorithm to solve the incorrect calculation problem using boundary information. We found that the modified Goldstein algorithm could resolve the Goldstein algorithm's problem.